N847AS, cancelled Jul 30, 2018
Service difficulty reports · 150
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N847AS' AND deregistration_id = 'N847AS-2018-07-30' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N847AS' AND deregistration_id = 'N847AS-2018-07-30' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA201101616Lamp · burned outWHITE EMERGENCY LIGHT ON LOWER PORTION OF FWD WARDROBE HAS INOP BULBS. RELAMPED THE EMERGENCY FLOOD LIGHT ASSY ON THE FWD WARDROBE AS REQUIRED. OPS CHECKED GOOD IAW AMM 33-51-00.SDR ASOA201100278Lamp · burned outNR5 EMERGENCY EXTERIOR LIGHT WILL NOT ILLUMINATE WHEN COMMANDED. REMOVED AND RELAMPED NR 5 EXTERNAL EMERGENCY LIGHT ASSY IAW 33-51-21. OPS CHECK GOOD.SDR ASOA201100163Floor Panel · corrodedLT SIDE PRESSURE FLOOR CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 AND FS 559. REPAIRED IAW REO 601R-53-41-666.SDR ASOA201100162Floor Panel · corrodedRT SIDE PRESSURE FLOOR CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 TO 559. BLENDED CORROSION IAW REO 601R-53-41-666.SDR ASOA201100169Floor Panel · corrodedRT PRESSURE FLOOR CORRODED AT SEVERAL LOCATION BETWEEN FS 409 TO 559. REPAIRED IAW REO 601R-53-41-666.SDR ASOA201100168Floor Panel · corrodedRT PRESSURE FLOOR CORRODED AT SEVERAL LOCATION BETWEEN FS 409 AND 559. PERFORMED UT THICKNESS INSPECTION OF BLEND AREAS IAW MAC NDT INSPECTION PROCEDURE UT-3. BLENDS AREAS ARE WITHIN ALLOWABLE LIMITS OF REO 601R-53-41-666 TABLE 2.SDR ASOA201100102Angle · corrodedSERVICE DOOR SILL ANGLE HAS CORROSION DAMAGE. FOUND TO BE OUT OF LIMITS IAW SRM 53-21-23, DRILLED/SEALED PLATE & INSTALLED IAW SRM 51-42-21, SRM 51-42-06 AND SRM 51-42-21. MINOR REPAIR.SDR ASOA201100094Bulkhead · crackedAFT PRESSURE BULKHEAD FWD FACE IS CRACKED ABOVE LINTEL ATTACH POINT. PERFORMED CUT OF ANGLE IAW REO 601R-53-61-1230. COMPLIED WITH STEP 7 OF REO 601R-53-61-1230. NO INDICATIONS NOTED AT THIS TIME. COMPLY WITH STEPS 8-14 OF REO 601R-53-61-1230. FABRICATED PN SDR ASOA201100074Bulkhead · corrodedSMALL AREA OF CORROSION ON THE FWD SIDE OF FS 202.00 BULKHEAD AROUND THE PARKING BRAKE CABLE. REMOVED SURFACE CORROSION IAW SRM 51-26-00,SDR ASOA201100119Floor Support · corrodedFLOOR SUPPORT HAS MINOR CORROSION AROUND SCREW HOLES AT LBL 27 FROM FS 589.00 TO 621.00. REMOVED CORROSION FROM FLOORBEAM IAW SRM 51-21-06 BEAM IS OUT OF LIMITS IAW 53-00-00. REMOVED FLOOR SUPPORT CAP FROM LBL 27, FS 574.00-FS 620.00. ALL WORK DONE IAW SRMSDR ASOA201100100Attach Fitting · crackedLT O/W FUSELAGE PANEL, 161DL, ATTACH STRUCTURE JUST FWD OF CTR WING-TO-FUSELAGE ATTACH FITTING AT FS 473.15 CRACKED APPROX .5"L. R & R FUSELAGE PANEL 161DL ATTACH ANGLE PN 601R31037-61 IAW SRM 51-42-20 AND 51-23-16. MINOR REPAIR.SDR ASOA201100064Seat Track · corrodedSHORT CARGO TIE DOWN SEAT RAILS AT WL 73.5 LBL 9.00,FS 559.00+80 TO FS 559.00+96 HAS CORROSION. R & R SHORT CARGO TIE DOWN SEAT RAIL ON LBL 9.00 BETWEEN FS 559 + 80 TO FS 559 + 96 IAW AMM 20-21-00-02. THIS IS A MINOR REPAIR.SDR ASOA201100063Cargo Track · corrodedCORROSION FOUND ON SHORT CARGO TIE DOWN SEAT RAIL AT WL 73.5, RBL 9.00,FS 559.00+112 TO FS 574.00. R & R CARGO TIE DOWN SEAT RAIL ON RBL 9.00 BETWEEN FS 559.00 + FS 574 IAW AMM 20-21-00-02. THIS IS A MINOR REPAIR.SDR ASOA201100062Cargo Track · corrodedCORROSION FOUND ON SHORT CARGO TIE DOWN SEAT RAIL AT WL73.5, LBL9.00, FS 559.00+112 TO FS 574.00. R & R SHORT CARGO TIE DOWN SEAT RAIL SECTION ON LBL 9.00 BETWEEN FS 559 + 112 TO FS 574.00 IAW AMM 20-21-00-02. THIS IS A MINOR REPAIR.SDR ASOA201100061Cargo Track · corrodedCORROSION FOUND ON SHORT CARGO TIE DOWN SEAT RAIL AT WL73.5, RBL9.00, FS 559.00+80 TO FS559.00+96. R & R SHORT CARGO TIE DOWN SEAT RAIL SECTION ON RBL 9.00 BETWEEN FS 559 + 80 TO FS 559 + 96 IAW AMM 20-21-00-02. THIS IS A MINOR REPAIR. (CLOSED)SDR ASOA201100060Pressure Panel · corrodedRT SIDE PRESSURE FLOOR CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 TO 559. REMOVED CORROSION IAW SRM 51-21-06. PERFORMED UT THICKNESS OF BLENDED AREAS IAW MAC NDT INSP PROCEDURE UT-3. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS OF SRM 53-41-45 FIGURE 101. DASDR ASOA201100059Pressure Panel · corrodedLT SIDE PRESSURE FLOOR CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 AND 559. REMOVED CORROSION IAW SRM 51-21-06. PERFORMED UT THICKNESS OF BLENDED AREA IAW MAC NDT INSP PROCEDURE UT-3. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS OF SRM 53-41-45 FIG 101. DASDR ASOA201100058Seat Track · corrodedSEAT TRACK CORRODED FROM 409+126 TO 559+4 AT RBL9. REMOVED AND REPLACED SEAT TRACK IAW AMM 53-01-000-802 AND AMM 53-01-11-400-802.SDR ASOA201100057Seat Track · corrodedSEAT TRACK CORRODED AT LBL9 FROM 409+126 TO 559+4. REMOVED AND INSTALLED SEAT TRACK IAW AMM 53-01-11-400-802, STEP 2B.SDR ASOA201001825Flashlight · inoperativeFIRST OFFICERS FLASHLIGHT INOP. REPLACED FO'S FLASHLIGHT IAW CRJ 200 AMM 25-60-00.SDR ASOA201000960Relay · wornAFTER TAKEOFF SELECTED GEAR UP AND RECEIVED GEAR DISAGREE WARNING (EMERGENCY DECLARED -- ACFT RETURNED TO DEPARTURE AFTER T/O) R & R WOW SENSOR NR 1 RELAY, K1GA, IN JB11 IAW ESPM 20-22-00. REFER TO AFDL NR 533372-2 FOR GEAR OPS CKS.SDR ASOA201000959Selector Valve · failedON TAKEOFF SELECTED GEAR UP, RECEIVED GEAR DISAGREE WARNING. THE PILOT REPORT THAT MANUAL RELEASE HANDLE WILL NOT STOW , LOST NOSE WHEEL STEERING TOWED BACK TO GATE. (EMERGENCY DECLARED -- ACFT RETURNED TO DEPARTURE AFTER T/O) R & R NLG SELECTOR VALVE ASSY ISDR ASOA201000407Lamp · inoperativeEXTERIOR EMERGENCY LIGHT NR 8 INOP. R & R LAMP IN EXTERIOR EMERGENCY LIGHT NR 8 IAW AMM 33-51-21. OP'S CHECK GOOD.SDR ASOA201000376Pseu · failedAFTER TAKEOFF SELECTED, GEAR HANDLE UP, FOLLOWED BY GEAR DISAGREE WARNING MSG. ALL 3 GEAR ICAS SHOW WHITE AND UP WARNING MSG WENT OUT AFTER ABOUT 5-10 SECONDS. COMPLIED WITH QRH, DECLARED EMERGENCY AND RETURNED TO DEPARTURE, LANDED UNDER 47,000 LBS. ACFT RESDR ASOA200901325Warning Light · illuminatedRT ENGINE OIL PRESSURE WARNING IN FLIGHT, SECOND WRITE UP OIL PRESSURE FLUCTUATING BETWEEN 20-37 PSI, WARNING PERSIST AT OR ABOVE CRUISE POWER SETTING. (EMERGENCY DECLARED -- ACFT RETURNED TO DEPARTURE AFTER T/O)SDR ASOA200901131Heater · malfunctionedFLT 5287, RT WINDSHIELD (NR 3) HEAT CAUTION MSG IN FLT. RAN QRH AND CAUTION MSG STAYED ON. ALSO HAD AN ELECTRICAL BURNING ODOR DID NOT SEE SMOKE AND DID DECLARE AN EMERGENCY. [EMERGENCY DECLARED -- ENROUTE TO ATL A/C DIVERTED TO MGM DUE TO MTC].SDR ASOA200900749Flap · failedFLAPS FAIL AT 5 DEGREES. EMERGENCY DECLARED.SDR ASOA200900395Warning System · activatedRECEIVED GEAR DISAGREE WARNING AFTER RETRACTING LANDING GEAR ON CLIMBOUT (NOSE GEAR). COMPLIED QRH 47000 LB NORMAL LANDING. EMERGENCY DECLARED. A/C RETURNED TO ATL AFTER T/O.SDR ASOA200900050Post · crackedOPS 193 CONTINUED FROM JOB NR 8733515 OP NR 173. FS 409.0+128 VERTICAL POST BL 0 HAS INDICATION NOTED APPROX 3 INCH IN LENGTH 90 PERCENT FULL SCREEN HEIGHT RT SIDE WL 69.0 FLANGE, FAILED NDT INSP. INSTALLED NEW SERVICEABLE REINFORCING ANGLE ON POST BL 0 AT WL SDR ASOA200900047Structure · crackedSUSPECT CRACK ON NLG AFT DOOR CUTOUT IN RADIUS ON RT SIDE.SDR ASOA200900060Post · unknownJOB 8733515 OPERATION 174 F.S. 409+128 VERTICAL POST HAS INDICATION NOTED APPROX .3" IN LENGTH AT RBL 18.0 WL 69.0 I/B AND O/B FLANGES 90% FULL SCREEN HEIGHT FAILED NDT INSP.SDR ASOA200900059Post · unknownJOB 8733515 OPERATION 173 F.S. 409+128 VERTICAL POST BL 0.0 HAS INDICATION NOTED APPROX .3" IN LENGTH 905 FULL SCREEN HEIGHT RT WL 69.0 FLANGE FAILED NDT INSP.SDR ASOA200900058Post · unknownJOB 8733515 OPERATION 172 F.S. 409+128 VERTICAL POST LBL 18.0 HAS INDICATION NOTED APPROX .3" IN LENGTH 90% FULL SCREEN HEIGHT OTBD SIDE WL 64 FLANGE FAILED NDT INSP.SDR ASOA200900019Repair · crackedLT FS 718 FRAME PREVIOUS REPAIR CRACKED 2" LONG BETWEEN STRS 10L AND 11L.SDR ASOA200900013Bulkhead · crackedFS 559.0 BULKHEAD WEB AND CAP ANGLE HAS INDICATIONS NOTED AT L CAP ANGLE LBL 18 APPROX .4" IN LENGTH 70% FSH AND RT WEB WL 54.10, WL 58.70 WK 54.10 APPROX .3" AND .5" IN LENGTH 100% FSH ALL FAILED NDT INSP. COMPLIED WITH REO 601R-53-41-260, REPAIRE TO PRESSURSDR ASOA200900012Sill · corrodedIN CARGO COMPARTMENT FLOOR STRUCTURE FROM FS 559.00+112 TO FS 621.00 RBL 36.00 SILL PLATE HAS MINOR CORROSION AROUND FASTENER HOLES.SDR ASOA200900011Unknown · odorON DESCENT INTO INTO ATL THROUGH FL 270 SMELLED BURNING SMELL LIKE ELECTRICAL OR BURNING HAIR. SMELL WAS ISOLATED TO COCKPIT. NONE SMELLED IN PACKS OR BY FA STRONG SMELL LASTED ABOUT 45 SEC. NO INDICATION FROM CBS OR ELEC PAGE.SDR ASOA200900010Floor Support · crackedREAR PRESSURE BULKHEAD FLOOR SUPPORT ANGLE FS 621 LEFT SIDE IS CRACKED.SDR ASOA200900009Structure · corrodedIN PASSENGER COMPARTMENT FLOOR STRUCTURE PASSENGER DOOR HANDRAIL CUPS FS 315.00 AND FS 343.00 LBL 36.00 HAS MINOR SURFACE CORROSION.SDR ASOA200900008Intercostal · corrodedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 349.00 INTERCOSTAL TOP CAP BETWEEN LBL 27.00 AND LBL 36.00 HAS SEVERAL NUTPLATE FASTENERS AND ATTACHMENT FASTENERS CORRODED.SDR ASOA200900007Intercostal · corrodedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 349.00 INTERCOSTAL TOP CAP BETWEEN RBL 27.00 AND RBL 36.00 HAS SEVERAL NUTPLATE FASTENERS AND ATTACHMENT FASTENERS CORRODED.SDR ASOA200900006Attach Angle · crackedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 280.00 LBL 9.00 OUTBD ATTACHMENT ANGLE CRACKED.SDR ASOA200900005Attach Angle · crackedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 280.00 LBL 9.00 INBD ATTACHMENT ANGLE CRACKED.SDR ASOA200900004Attach Angle · crackedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 484.00 LBL 27.00 OUTBD ATTACHMENT ANGLE CRACKED.SDR ASOA200900003Attach Angle · crackedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 484.00 LBL 9.00 OUTBD ATTACHMENT ANGLE CRACKED.SDR ASOA200900002Attach Fitting · crackedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 460.00 RBL 9.00 OUTBD INTERCOSTAL ATTACHMENT FITTING CRACKED.SDR ASOA200900001Attach Angle · crackedIN PASSENGER COMPARTMENT FLOOR STRUCTURE FS 484.00 RBL 27.00 OUTBD ATTACHMENT ANGLE CRACKED.SDR ASOA200801693Light · inoperativeEMERGENCY LIGHT ON BY PREVIOUS CREW OR CLEANING CREW. FLIGHT ATTENDANTS REPORTS LIGHT INOP. FLT 5034 DEL 92 MINS.SDR ASOA200801317Anchor Fitting · crackedASD FWD ANCHOR FITTING CRACKED. REMOVED & REPLACED TO COMPLY WITH SB 601R-52-116. PERFORMED MX IAW AMM TASKS; 52-11-17-000-803, 52-11-17-400-803, AND S.B. 601R-52-116 WITH REO 601R-52-11-1572. COMPLIED WITH ADJUSTMENT AND OPERATIONAL TEST. CHECKED GOOD.SDR TRAX200800778Line · failedHYDRAULIC SYSTEM 3 LOST ALL FLUID WHEN GEAR EXTENDED. EMERGENCY DECLARED, EMERGENCY TRUCKS FOLLOWED A/C TO THE GATE. REMOVED AND REPLACED 3B HYDRAULIC PUMP PRESSURE LINE IAW CRJ 200 AMM 29-12-18. OPS AND LEAK CK GOOD. LINE P/N AE4096G0060-000.