Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA140724003Landing Gear · inoperative(CAN) CREW REPORTED THAT THE LT MLG FAILED TO RETRACT AFTER TAKEOFF. ACFT RETURNED TO DEPARTURE AIRPORT AND LANDED SAFELY WITHOUT INCIDENT. NO EMERGENCY WAS DECLARED.SDR CA140724006Selector · malfunctioned(CAN) AFTER GEAR DOWN SELECTION, LT MLG AND NLG NOT DOWN AND LOCKED. GO AROUND AND DURING RADAR VECTORING CHECKLIST WITH ALTERNATE LANDING GEAR EXTANSION PERFORMED. AS ALL 6 LDG GEAR INDICATION LIGHTS SHOWED THAT GEAR WAS DOWN AN LOCKED, A NORMAL UNEVENTFUL LSDR QXEA2014072400609Skin · misrepairedINBD AFT NACELLE SKIN TRIMMED INCORRECTLY. LOCATED AND DRILLED NEW REPLACEMENT PANEL IAW RD8/4-54-1340, ISSUE 1, DATED 7/13/2014. FABRICATED NEW REPLACEMENT PANEL USING MATERIAL, PN:20024-T3.063", PO:T-20092 IAW RD8/4-54-1340, ISSUE 1 DATED 2014-07-13. PERFSDR CA140718004Fmu · leaking(CAN) AFTER SHUTDOWN AT THE GATE, THE CREW RECEIVED A POWERPLANT MESSAGE ALONG WITH THE NR 1 FADEC CAUTION LIGHT. THE CREW ALSO OBSERVED FUEL LEAKING FROM THE LT ENGINE. THE NR 1 FMU WAS REPLACED AND GROUND RUNS CARRIED OUT AND THE ACFT WAS RETURNED TO SERVISDR CA140716007Bearing · damaged(CAN) CREW REPORTS APPARENT WHEEL BEARING FAILURE. TECHNICIANS HAVE ARRIVED ON SCENE AND CONFIRMED WHEEL BEARING FAILURE. WHEEL INSTALLED ON NR 1 POSITION INSTALLATION OCCURRED IN ADD ON LINE. LESS THAN 30HOURS TIME IN SERVICE SINCE REPAIR/INSTALLATION. REVSDR QXEA2014072200596Mount · corrodedNR 2 ENGINE FWD UPPER MOUNTING PAD HAS MINOR CORROSION. CLEANED AND REPAIRED NR 2 ENGINE FWD UPPER MOUNTING PAD IAW AMM TASK 72-00-00-350-806 AND AMM TASK 72-10-00-210-801.SDR QXEA2014072200597Mount · corrodedNR 2 ENGINE FWD LEFT INBD MOUNTING PAD HAS MINOR CORROSION. CLEANED AND REPAIRED NR 2 ENGINE FWD LT MOUNT PAD IAW AMM TASK 72-00-00-350-806 AND TASK 72-10-00-210-801.SDR QXEA2014072200598Mount · corrodedNR 2 ENGINE RIGHT FWD OTBD MOUNTING PAD HAS MINOR CORROSION. CLEANED AND REPAIRED IAW AMM 72-00-00-350-806 AND AMM 72-10-00-210-801.SDR CA140717013Reservoir · leaking(CAN) DURING SERVICE, HYDRAULIC LEAK WAS DISCOVERED. IT WAS DISCOVERED THAT THE HYDRAULIC LEAK WAS COMING FROM THE DIPSTICK TUBE OF THE ALTERNATE GEAR EXTENSION RESERVOIR. THE RESERVOIR WAS ALMOST EMPTY. THIS AREA IS ALREADY SUBJECT TO SB 84-29-34 & SUBSEQUSDR CA140714001Wheel · damaged(CAN) AFTER LANDING IN GDN OUR CPT REPORTED DAMAGED BRAKE AND WHEEL. OUR ENGINEERS NOW PERFORM T/S FULL DAMAGE REPORT ON AXLE CONDITION WILL FOLLOW AFTER A/C WILL BE TOWED TO HANGAR AND AFTER INNER BEARING REMAINS WILL BE REMOVED. THERE IS NO GOOD PHOTO OF INNSDR CA140710005Lock · stuck(CAN) DURING CRUISE, A PASSENGER BECAME LOCKED INSIDE THE LAVATORY COMPARTMENT. CREW HAD TO USE THE FIRE AXE TO OPEN THE LAVATORY DOOR. MAINTENANCE VISUAL INSPECTION OF THE LOCK ASSEMBLY REVEALED THAT IT WAS STUCK IN THE EXTENDED POSITION AND THE TEFLON LOCK BSDR CA140708001Selector Valve · failed(CAN) 3 RED GEAR UNSAFE ADVISORY LIGHTS ILLUMINATED WITH LANDING GEAR SELECTED UP AFTER TAKEOFF. THE "ALL LANDING GEAR FAIL TO RETRACT" CHECKLIST WAS CONDUCTED FROM THE QRH WITH NORMAL GEAR DOWN INDICATIONS ON COMPLETION. A RETURN TO LAND. A NORMAL LANDING WSDR CA140807014Wire · damaged(CAN) FLIGHT CONDUCTED A FLIGHT DIVERSION ON SATURDAY JULY 5TH FOR CONVENIENCE REASONS DUE TO A FWD CARGO DOOR WARNING IN FLIGHT. AFTER INTERROGATING THE PSEU AND PRESSURIZING THE AIRCRAFT, MAINTENANCE COULD NOT DUPLICATE THE FAULT ON THE GROUND AND THE AIRCRASDR CA140730015Coupling · damaged(CAN) DUE TRO THE FINDINGS ON AIRCRAFT 4127 THE OPERATOR CHOSE TO INSPECT AIRCRAFT MSN 4350, THE OPERATOR FOUND SEVERAL FUEL PIPES & FUEL COMPONENTS IN ENGINE FUEL FEED SYSTEM WITH SIGNS OF CHAFING ON THE FERRULE ENDS OF THESE COMPONENTS. THE OPERATOR HAS ALSOSDR QXEA2014070500555Connector · damagedDURING TAKEOFF AT 70 KIAS, NR 2 ENGINE FUEL TEMP INDICATOR ROSE RAPIDLY TO 86 DEGREE C WITH POWER APPLICATION. ABORTED TAKEOFF AND RETURNED TO GATE. FOUND FUEL TEMPERATURE ERRATIC WHEN NR 2 FUEL TEMP SENSOR CONNECTOR AND WIRING IS MANIPULATED. R & R NR 2 ENGSDR CA140717003Clamp · disconnected(CAN) AIRCRAFT HAD DEPRESSURIZATION DURING CRUISE. RECIRCULATION DUCT FOUND DISCONNECTED IN THE AFT EQUIPMENT BAY. CLAMP SHELL WAS FOUND SEPARATED FROM THE DUCT. RECIRCULATION DUCT WAS RE ASSEMBLED AND THE CLAMP ATTACHED AND SECURED. PRESSURISATION RUNS COMPLSDR CA140707007Autopilot Sys · failed(CAN) DURING DESCENT, THE ACFT AGGRESSIVELY ROLLED UNCOMMANDED TO THE RT. THE AUTOPILOT WAS AUTOMATICALLY DISENGAGED, NOT BY THE PF AND THE PF WAS ABLE TO REGAIN CONTROL OF THE ACFT. "YD NOT CENTERED" AND "AP DISENGAGED" MESSAGES APPEARED ON THE PFD. ONCE TSDR CA140701018Strut · damaged(CAN) AIRCRAFT IS HAVING AOG AFTER SIGNIFICANT EVENT ON LANDING AT AN AIRPORT. MLG DID NOT COMPRESS. DURING POST FLIGHT INSPECTION CREW FOUND OVEREXTENSION RT MLG SHOCK STRUT. DRESSED SHOCK STRUT, PN 46100-55. CURRENT STATUS 13167 FLIGHT CYCLES, NO OVERHSDR QXEA2014062800547Actuator Valve · failedDURING CLIMBOUT 14000 FT TO FL 220, NR 1 AND 2 FUEL TEMP ON ED TURNED RED, RAN EAC. TURNED AUX PUMPS ON BRINGS TEMP DOWN BUT WENT RIGHT BACK UP WHEN AUX PUMPS TURNED OFF BOTH FUEL TEMPS RED ON GROUND WITH AUX PUMPS RUNNING BOTH TEMPS DID NOT EXCEED 74 DEGRSDR CA140804015Bypass Valve · failed(CAN) DURING CLIMB, BOTH ENGINE FUEL TEMPS IN THE RED. MAINTENANCE REPLACED BOTH THERMAL BYPASS VALVES.SDR QXEA2014070100541Support · damagedFORWARD SUPPORT HAS SEPARATING METAL SEAL ON ENGINE FRAME SIDE. TRIMMED DAMAGED FRAME PLATE ON LT NACELLE FWD UPPER FRAME ASSY OTBD SIDE IAW SRM 54-10-01, STEP 7A (1). FABRICATED REPLACEMENT FRAME PLATE IAW SRM 54-10-01, STEP 7 A(3). FABRICATED REPAIR SPLICSDR CA140627008Warning Message · false activation(CAN) ABORTED TAKEOFF WAS INITIATED FOLLOWING THE VISUAL AND AUDIO FROM THE MASTER WARNING. BY THE TIME THE AIRPLANE CAME TO A FULL STOP THERE WERE NO CAUTION OR ADVISORY LIGHTS LEFT ON THE PANEL TO IDENTIFY THE CAUSE OF THE MASTER WARNING. TOWER WAS ADVISED SDR CA140626004Fuel Heater · leaking(CAN) THE PILOT REPORTED THAT THE LT FUEL INLET TEMPERATURE WAS IN THE RED. TURNING ON THE AUX FUEL PUMP IAW THE QRH LOWERED THE TEMPERATURE. THE HIGHEST TEMPERATURE OBSERVED WAS 74 DEGREES. MAINTENANCE PROCEEDED TO REPLACE THE LT FUEL HEATER TEMPERATURE CONTSDR CA140703004Clamp · broken(CAN) APU DC STARTER GENERATOR V-BAND CLAMP, T-BOLT FOUND BROKEN OFF AT THE TEE. QUAD ADAPTER INSPECTED AND FOUND DAMAGED FROM THE STARTER GENERATOR UNSECURED MOVEMENTS DURING OPERATION. PARTS REPLACED AND RETURNED TO SERVICE. AFH 7924.21, AFC 5760, SG TSN 1SDR CA140623004Wheel · damaged(CAN) MAINTENANCE OPERATIONS NUMBER 3 MLG WHEEL BEARING FAILURE 1. AIRCRAFT AOG DUE TO A NUMBER 3 MLG WHEEL BEARING FAILURE. 2. PILOT REPORTS THAT DURING WALK AROUND HE NOTICED A LARGE AMOUNT OF HEAT EMANATING FROM THE NUMBER 3 BRAKE. 3. PILOT NOTIFIED TECSDR CA140620009Pump · failed(CAN) PILOT REPORTED AFTER LANDING THAT DURING FLIGHT HE HAD STRONG VIBRATIONS, HYD PUMP NR 2 CAUTION LIGHT, RESERVOIR NR 2 EMPTY ROOT CAUSE, INSPECTION FOUND NR 2 EDP FAILED.SDR QXEA2014061600517Pump · failedNR 2 ENGINE FAILED OPS CHECK OF PROPELLER ALTERNATE FEATHER IAW T/C 612000202. THE MAINTENANCE UNFEATHER FUNCTION FAILED IAW STEPS 2D, 2E, 2F, ALL OTHER FUNCTIONS NORMAL. REPLACED ALTERNATE FEATHER PUMP. OPS CHECKS GOOD. RETURNED TO SERVICE.SDR CA140806011Hose · leaking(CAN) AFTER SELECTING FLAP 5 AND GEAR DOWN THE NR 2 HYD ISO VALVE AND ROLL SPOILER OTBD HYD CAUTION LIGHTS WERE ILLUMINATED. THE CREW PERFORM A NORMAL APPROACH AND LANDING, ALSO CONDUCTED A SLOW AND CONTROLLED TAXI BACK TO BAY DUE TO THE LOSS OF THE NOSE WHEESDR CA140619001Lever · malfunctioned(CAN) OPERATOR REPORTED THAT THE AIRCRAFT ABORTED TAKE OFF - DUE TO THE SPOILERS DID NOT RETRACT: TAKE OFF WARNING HORN CAME ON - CREW ABORTED TAKE OFF AND RETURNED TO RAMP. MAINTENANCE CREW FIGURED OUT DURING TROUBLE SHOOTING, THAT THE MICRO SWITCH IN THE PLASDR CA140616005Bolt · loose(CAN) THE OIL PUMP TRANSFER TUBE BRACKET BOLTS BECOME LOOSE DURING OPERATION OF THE ENGINE AND THE BRACKET DROPS ON THE TUBE CAUSING FRETTING ON THE MAIN FUEL PRESSURE TUBE. DURING ROUTINE MAINTENANCE, THE FUEL PRESSURE TUBE EXHIBITED HEAVY FRETTING WEAR. PSDR QXEA2014060800464Gearbox · leakingNR 2 ENGINE WOULD NOT UNFEATHER AFTER START. INTERROGATED CDS NO CODES FOUND IAW AMM 61-20-00-710-804. R & R OSG IAW AMM 61-20-26-000/400-801 NO HELP. LEAKAGE NOTED AT OSG. REMOVED OSG IAW AMM 61-20-26-00-801. REINSPECTED AND CLEANED SURFACE NO OBSTRUCTION SDR CA140609004Sequence Valve · failed(CAN) FLIGHT RETURN DUE TO NLG DOORS REMAIN OPEN. THE SOLENOID SEQUENCE VALVE HAS BEEN REPLACED FOR C/A WITH 1:35 HRS DELAY. NLG SOLENOID SEQUENCE VALVE REPLACED.SDR CA140609003Bearing · failed(CAN) NR 4 MAIN WHEEL BEARING FAILED ON LANDING. PILOT REPORTED COMPLETE LOSS OF FLUID IN THE NR 2 HYD SYSTEM, UNCERTAIN AT THIS TIME EXACTLY WHEN FLUID WAS LOST. TECH DISCOVERED AN APPARENT FAILURE OF THE NR 4 MLG WHEEL ASSY. LOSS OF HYD FLUID DUE TO NR 4 SDR CA140617005Wheel · damaged(CAN) ACFT LANDED AND WAS TOWED TO PARKING STATION, WALK AROUND REVEALED THE NR 4 TIRE WAS FLAT AND THE NR 4 BRAKE LINE SEVERED. FURTHER INVESTIGATION REVEALED LARGE AMOUNT OF DAMAGE TO NR 4 WHEEL ASSY, BRAKE, AXLE, BRAKE HOSE AND SEVERAL OTHER PARTS. NOTE: SDR CA140624002Starter Gen · misinstalled(CAN) DURING A SCHEDULED DC STARTER GENERATOR REPLACEMENT 1 OF THE TERMINAL LEADS WAS NOT SECURED COMPLETELY DURING THE INSTALLATION OF THE REPLACEMENT STARTER GEN. BECAUSE THE LOOSE LEAD WAS NOT DETECTED BEFORE THE FUNCTIONAL TEST IT CAUSED THE TERMINAL TO ASDR R61A201406040721Bypass Valve · failedFLYING AT 10,000 FT CREW REPORTED NR 2 OIL TEMP WAS 107. CREW RAN QRH, REDUCED TORQUE AND OIL TEMP ROSE TO 119 WHERE IT REMAINED FOR 10 MINUTES. BECAUSE TEMP WAS HIGH FOR 10 MINUTES, CREW SHUTDOWN ENGINE, RETURNED TO DEPARTURE AND DECLARED AN EMERGENCY. CRESDR CA140604008Actuator · failed(CAN) ON APPROACH NLG DID NOT EXTEND. ALTERNATE GEAR DOWN SELECTION USED. GEAR EXTENDED NORMALLY AND UNEVENTFUL LANDING PERFORMED. MAINTENANCE REPLACED THE NOSE GEAR DOOR ACTUATOR AND RETURNED THE ACFT TO SERVICE.SDR CA140604011Sequence Valve · failed(CAN) NLG WOULD NOT EXTEND DURING APPROACH, ALTERNATE EXTENSION REQUIRED. NORMAL LANDING NO EMERGENCY DECLARATION. REPLACED NLG SOLENOID SEQUENCE VALVE & NLG DOOR ACTUATOR ASSY.SDR QXEA2014060300461Controller · no testAUTOFEATHER TEST FAILED FOR NR 2 ENGINE. COMPLIED WITH FIM TASK TASK 61-20-00-810-805. FOUND FAULTS 398, 404, 280, 282, 398 AND 70 ON NR 2 PEC. R & R NR 2 PEC IAW AMM 61-20-36-000-801/-400-801. C/W MAINTENANCE 671008. ALL OPS CHECKS GOOD. C/W OPS TEST OFSDR CA140605006Proximity Sensor · failed(CAN) AFTER TAKEOFF, A MASTER WARNING LIGHT WENT ON INDICATING THE FUSELAGE DOOR, 2R SERVICE DOOR, AJAR. THE ACFT CLIMBED TO SID ALTITUDE OF 5,000 FT AND NOTIFIED ATC. THE CHECKLIST FOR THIS WARNING WAS COMPLETED AND THEN THE DECISION WAS MADE BY THE FLIGHT CSDR QXEA2014060200448Autofeather Sys · no testAUTOFEATHER TEST FAILED. CDS FAULT CODE IS NR 1 ENG 398. COMPLIED WITH FIM 61-20-08-810-818. R & R NR 1 PEC IAW AMM 61-20-36-000-801, 61-20-36-400-801.SDR CA140612004Generator · failed(CAN) NR 1 AC GENERATOR CAUTION LIGHT ILLUMINATED JUST AFTER STARTING TAKEOFF ROLL THEN FLIGHT CREW REJECTED TAKEOFF. THE CAUTION LIGHT DID NOT GO OFF BY RESET THE NR 1 AC GENERATOR SWITCH OFF THEN ON. ENGINEER PERFORMED OPS TEST OF AC GENERATOR SYS AND CONFSDR CA140606009Engine · fod(CAN) DURING STATIONARY GROUND RUNS IN SUPPORT OF MAINTENANCE TROUBLESHOOTING PROCEDURES, THE ENGINE EXPERIENCED INTERNAL DAMAGE WITH THE RESULTANT RELEASE OF HIGH-ENERGY PARTICLES. THE INCIDENT IS CURRENTLY UNDER INVESTIGATION WITH FINDINGS TO BE CONVEYED ONSDR CA140602026Yaw Damper · malfunctioned(CAN) ON DEPARTURE JUST AFTER V1 THE ACFT PULLED ABRUPTLY TO THE LT, CORRECTED WITH RT RUDDER AS WE WERE JUST ABOUT TO ROTATE. FLEW THE DEPARTURE IAW SOP. RULED OUT A WIND GUST BECAUSE THE WIND WAS LIGHT AT THE TIME OF DEPARTURE. CHECKED FOR FAULT CODES. TSDR CA140605004Bearing · failed(CAN) NR 1 WHEEL BEARING FAILED ON LANDING. GRINDING NOISE DURING TAXI-IN AND BRAKE PARTS FOUND NEAR LT MAIN GEAR ON POST-FLIGHT. AXLE, WHEEL, AND BRAKE REPLACED. PERFORMED WHEEL BEARING FAILURE INSPECTION/CHECK, AMM, TASK 05-50-17-210-801, DUE TO DAMAGE, R &SDR CA140528007Landing Gear · warning message(CAN) DEPARTING RUNWAY, THE MASTER CAUTION SOUNDED. PM CANCELLED THE MASTER CAUTION LIGHT, STATED "CONTINUE" AND HAD OBSERVED THE LDG INOPERATIVE CAUTION LIGHT "FLICKER" BRIEFLY BUT REMAINED OFF. ONCE AIRBORNE THE LANDING GEAR LEVER WAS SELECTED UP BUT NO APPSDR CA140605003Indicator · failed(CAN) TAKE OFF WARNING WAS TRIGGERED DURING TAKE OFFROLL, THE CREW REJECTED TAKE OFF AROUND 60 KTS. DUPLICATED DURING TROUBLESHOOTING ON GROUND, PITCH TRIM INDICATOR WAS REPLACED AND THE ACFT RTS.SDR CA140527009Connector · shorted(CAN) THE CREW REPORTED THAT THE LT FUEL INLET TEMPERATURE WAS INTERMITTENT. EXTENSIVE TROUBLESHOOTING FOUND CONNECTOR PLUG 7700-P67 ON THE LT ENGINE SHORTED INTERNALLY AND ALSO THE WIRE PULLED OUT OF THE B-PIN WHILE IT WAS BEING EXTRACTED. IT APPEARED THAT TSDR CA140526008Landing Gear · unknown(CAN) CREW CALLED FOR GEAR DOWN. BOTH MAIN GEAR INDICATED DOWN AND LOCKED, AND DOORS CLOSED. THE NOSE GEAR RED UNSAFE LIGHT AND AMBER SELECTOR HANDLE WERE ILLUMINATED. THE ALTERNATE DOWN LOCK VERIFICATION SYS CONFIRMED THIS. TOWER WAS INFORMED THAT A GO-AROSDR CA140523004Engine · smoke(CAN) SMOKE IN CABIN DURING DESCENT. MAINTENANCE, STARTING THE RT ENGINE, SMOKE OBSERVED FROM THE ENGINE ITSELF. THE ENGINEERS HAVE ISOLATED THE OIL LEAK TO THE DRAIN PIPE INDICATED BELOW. BORESCOPE INDICATED EXTENSIVE OIL WETTING EVIDENT AT THE 3RD STAGE L
Back to Pratt & Whitney Canada PW150A