SDR QXEA2012083100968Wire · damagedELECTRICAL ODOR IN AFT CARGO COMPARTMENT. INSPECTED AFT CARGO COMPARTMENT FOR ANY OBVIOUS DEFECTS, NONE NOTED. REMOVED BOTH LIGHT ASSY AND INSPECTED FOR SIGNS OF ARCING OR BURNING. FOUND LOOSE GROUND WIRE AND BAD SOCKET ON FWD LIGHT ASSY IN AFT CARGO COMPARAug 31, 2012 · N418QX · Bombdr DHC8402 · Light System WiringSDR QXEA2012083100969Propeller · malfunctionedNR 1 PROP FEATHER TEST FAILED. CHECKED CDS FOR FAULT CODES, NONE FOUND. OPS TEST OF THE PROPELLER AUTOFEATHER & UPTRIM SYS IAW AMM 61-20-00-710-801. CHECKED GOOD, NO DEFECTS NOTED. COULD NOT DUPLICATE. NO PARTS REPLACED.Aug 31, 2012 · N431QX · Bombdr DHC8402 · Propeller Feathering/ReversingSDR QXEA2012083100945Casting · crackedLOWER AFT CORNER CASTING ON FWD PAX DOOR CUTOUT CRACKED. CASTING FOUND TO BE OUT OF LIMITS IAW SRM 53-20-23-00-01. MATCH DRILLED TO EXISTING STRUCTURE IAW SRM 51-40-07-02-01. ALODINED NEW HOLES IAW SRM 51-21-10-02-01, PRIMED NEW HOLES IAW SRM 51-25-10-02-01Aug 31, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, StructureSDR QXEA2012083100951Frame · corrodedFRAME 301 HAS CORROSION BETWEEN STR 33-32S. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-01. MIN REMAINING THICKNESS .037", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801-PT 1. FOUNAug 31, 2012 · N409QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012083100952Frame · corrodedFRAME 94.8 HAS CORROSION BETWEEN STR 32-29S. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .036', CONFIRMED CRACK FREE AREA REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. FOUND WITHIN LIMITS IAug 31, 2012 · N409QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012083100953Frame · corrodedFRAME 49.5 HAS CORROSION BETWEEN STR 32-30P. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM IAW SRM 51-42-05-00-02. BLENDED OUT CORROSION IAW SRM 51-211-00-00-02. MIN REMAINING THICKNESS NOTED .047" CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00Aug 31, 2012 · N409QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012083100954Frame · corrodedFRAME 49.5 HAS CORRROSION BETWEEN STR 32-29S. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVET FOM IAW SRM 51-42-05-02-01. BLENDED OUT CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .046", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00Aug 31, 2012 · N409QX · Bombdr DHC8402 · Fuselage Main, FrameSDR CA120907002Actuator · failed(CAN) NR 2 OIL TEMP CLIMBED TO 117. CHECK LIST COMPLETED WITH AND TEMP REDUCED TO 114. IAW CHECK LIST, NR 2 ENGINE WAS SHUTDOWN. ACFT LANDED. ACOC THERMAL VALVE AND ACOC DOOR ACTUATOR REPLACED. NO HISTORY ON THIS ACFT IN LAST 60 DAYS.Aug 31, 2012 · Bombdr DHC8400 · Engine Oil CoolerSDR QXEA2012083000930Flap Track · wornLEFT NR 4 FLAP TRACK BEAM INBD WEB COATING AT FWD END WORN. BLENDED IAW RD 8/4-57-1238. MIN REMAINING THICKNESS .155" REF NTM 51-00-04-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-57-1238. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 8.2.1.Aug 30, 2012 · N405QX · Bombdr DHC8402 · Trailing Edge FlapsSDR QXEA2012083000966Stop Fitting · wornFORWARD EMERGENCY DOOR WILL NOT GO INTO WATER MODE WITH THE UPPER DOOR INSTALLED. RELEASE LATCH STOP IS WORN. REPLACED DOOR STOP IAW SRM 51-42-05. DOOR NOW GOES INTO WATER MODE WITH THE UPPER DOOR INSTALLED. OPS CHECKED GOOD.Aug 30, 2012 · N408QX · Bombdr DHC8402 · Emergency ExitsSDR QXEA2012083000935Flap Track · damagedLT INBD FLAP, INBD UPPER FLAP TRACK IS DAMAGED. BLENDED OUT DAMAGE REF RD 8/4-57-1352. REMAINING THICKNESS NOTED .174" CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-5Aug 30, 2012 · N405QX · Bombdr DHC8402 · Trailing Edge FlapsSDR QXEA2012083000941Attach Fitting · chafedFORE RUDDER FRONT SPAR UPPER PCU ATTACH FITTING IS CHAFED FROM MIGRATING BEARING. BLENDED DAMAGED AREA IAW SRM 55-41-20-02-02. DAMAGE WITHIN ALLOWABLE LIMITS IAW SRM 55-41-20-02-02. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. ALODINEDAug 30, 2012 · N405QX · Bombdr DHC8402 · Rudder StructureSDR CA120917001Fmu · leaking(CAN) THE CREW REPORTED A HEAVY FUEL LEAK AFTER NR 2 ENGINE SHUTDOWN. THE DRAIN TANK COULD NOT TAKE THE AMOUNT OF LEAKING FUEL AND A LOT OF RESIDUAL FUEL WAS FOUND INSIDE THE LOWER COWLING. POST FLIGHT FUEL CALCULATIONS REVEALED A SPLIT OF 150KG FOR THE FLIGAug 30, 2012 · Bombdr DHC8400 · Engine Fuel DistributionSDR QXEA2012082900931Lens · corrodedFOUND LT ENGINE INSPECTION LIGHT LENS CLOCKED INCORRECTLY AND MULTIPLE AREAS OF CORROSION IN THE LIGHT CUP. REMOVED INSP LIGHT IAW SRM 51-42-05-02-01. LOCATED AND DRILLED NEW LIGHT ASSY IAW SRM 51-40-07-02-01. INSTALLED LT INSPECTION LIGHT ASSY IAW SRM 51Aug 29, 2012 · N405QX · Bombdr DHC8402 · Exterior LightingSDR QXEA2012082900936Frame · corrodedFRAME X-18.25, FLANGES BETWEEN STRS 26S-33 BUBBLING PAINT POSSIBLE CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .036 REF NTM 51-00-04-910-801 PT 1. VERIFIED CRACK FREE AREA REF NDTM 51-00-06-910-801, PT 1. MATERIAL LOSS FOUAug 29, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012082900938Strut · corrodedLT NACELLE AFT UPPER EMS STRUT A5 HAS AREAS OF CORROSION APPROX 8" FROM AFT END. SMOOTHED DAMAGE IAW SRM 51-14-00-02-01. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 8.2.1.1, REV 14. MATERIAL LOSS WITHIN LIMITS IAW RD 8/4-54-1041. PERFORMED DVI IAW RD 8/4-5Aug 29, 2012 · N405QX · Bombdr DHC8402 · Nacelle/Pylon, Main FrameSDR QXEA2012082900939Stringer · corrodedSTRINGER 25P AND HARDWARE CORRODED BETWEEN X1.00 AND X32.4. BLENDED AREAS OF CORROSION IAW SRM 51-21-00-00-02. STRINGER FOUND TO BE BEYOND REPAIR IAW SRM 53-20-17-00-01. REMOVED DAMAGED STRINGER 25P SECTION IAW RD 8/4-53-4728. CONFIRMED STRINGER CUT LIAug 29, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012082900943Frame · corrodedFRAME X71.2, FLANGES BETWEEN STRS 27P-33 BUBBLING PAINT PROBABLE CORROSION. REMOVED FLANGE REF RD 8/4-53-017. CLEANED SEALANT AND PRIMER FROM SKIN IAW Q400 SRM 51-26-10-02-01. BLENDED OUT CORROSION FROM FRAME FLANGES IAW RD 8/4-53-2344 AND Q400 SRM 51-21-00-Aug 29, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012082900963Access Panel · damagedCHAFE DAMAGE ON LT WING SKIN FUEL ACCESS PANEL LANDING, MATING SURFACE FOR PANEL 522BT. REMOVED CHAFE DAMAGE IAW RD 8/4-57-441. MIN REMAINING THICKNESS NOTED .186", CONFIRMED CRACK FREE AREA REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. LANDING FAug 29, 2012 · N409QX · Bombdr DHC8402 · Wing, Plate/SkinSDR QXEA2012082900964Access Panel · damagedPOSSIBLE CORROSION ON CHAFE DAMAGE ON RT WING SKIN FUEL ACCESS PANEL LANDING, MATING SURFACE FOR PANEL 622CT. REMOVED CORROSION IAW RD 8/4-57-441. MIN REMAINING THICKNESS NOTED LANDING .178, T FITTING .238", CONFIRMED CRACK FREE AREAS REF NTM 51-00-04-910-80Aug 29, 2012 · N409QX · Bombdr DHC8402 · Wing, Plate/SkinSDR QXEA2012082900965Access Panel · damagedPOSSIBLE CORROSION ON RT WING SKIN FUEL ACCESS PANEL LANDING, MATING SURFACE FOR PANEL 622AT. REMOVED CORROSION IAW RD 8/4-57-441. MIN REMAINING THICKNESS NOTED .177/.279 (LANDING) T FITTING .210/.244. CONFIRMED CRACK FREE AREAS REF NTM 51-00-04-910-801 PT Aug 29, 2012 · N409QX · Bombdr DHC8402 · Wing, Plate/SkinSDR CA120903007Engine · leaking(CAN) THE CREW REPORTED MOMENTARY OIL SMOKE IN THE CABIN OCCURRED DURING DECENT. THIS RESULTED IN THE ACTIVATION OF THE LAVATORY SMOKE DETECTOR. THE ACFT LANDED SAFELY. POST FLIGHT INSPECTION REVEALED AN OIL LEAK ON THE P2.2 DUCT. A SUBSEQUENT GROUND RUN SHOAug 29, 2012 · Bombdr DHC8400 · Engine (Turbine/Turboprop)SDR QXEA2012082800933Support · corrodedFORWARD PAX DOOR THRESHOLD SUPPORT IS CORRODED. CORROSION FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-1660. REMOVED THRESHOLD SUPPORT IAW SRM 51-42-05-02-01. INSTALLED NEW THRESHOLD SUPPORT CHANNEL IAW SRM 51-42-05-02-01. PRIMED THRESHOLD SUPPORT IAW SRM 51-25Aug 28, 2012 · N405QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012082800934Plate · corrodedFWD PAX DOOR THRESHOLD PLATE IS CORRODED. REMOVED THRESHOLD PLATE IAW SRM 51-42-05-02-01. FOUND OUT OF LIMITS IAW RD 8/4-53-1660. RECEIVED NEW PART AND MATCH DRILLED TO ACFT IAW SRM 51-40-07-02-01. INSTALLED NEW THRESHOLD MEMBER IAW SRM 51-42-05-02-01. PAug 28, 2012 · N405QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012082800940Channel · corrodedAFT RT SERVICE DOOR THRESHOLD EDGE CHANNEL HAS CORROSION ON TOP SURFACE BETWEEN BS 668 AND 698. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-40-19-00-01. REMOVED SERVICE DOOR THRESHOLD EDGE CHANNEL IAW SRM 51-42-05-02-01. MATCH DRILLED AND INSTALLED NUT PAug 28, 2012 · N405QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012082800942Retainer · corrodedFORWARD PAX DOOR LOWER SEAL RETAINER IS CORRODED. REMOVED LOWER SEAL RETAINER. RECEIVED NEW PART AND MATCH DRILLED TO AC IAW SRM 51-40-07-02-01. INSTALLED SEAL RETAINER IAW SRM 51-42-05-02-01. PRIMED AND PAINTED RETAINER IAW SRM 51-25-01-02-01 AND 51-25-15Aug 28, 2012 · N405QX · Bombdr DHC8402 · Passenger/Crew DoorsSDR QXEA2012082800955Spar · damagedRT HORIZONTAL FRONT SPAR UPPER AND LOWER FLANGE HAS WORKING FASTENERS AT YH -13.00. REMOVED FASTENERS IAW SRM 51-42-45-02-01. INSTALLED FASTENERS IAW SRM 51-42-45-02-01. APPLIED SURFACE PROTECTION IAW SRM 51-25-10-02-01.Aug 28, 2012 · N409QX · Bombdr DHC8402 · Horizontal Stabilizer, Spar/RibSDR QXEA2012082800956Spar · damagedLT HORIZONTAL FRONT SPAR UPPER AND LOWER FLANGE HAVE WORKING FASTENERS AT YH 13.00. REMOVED AND REINSTALLED 34 FASTENERS IAW SRM 51-42-45-02-01. APPLIED SURFACE PROTECTION IAW SRM 51-25-10-02-01.Aug 28, 2012 · N409QX · Bombdr DHC8402 · Horizontal Stabilizer, Spar/RibSDR QXEA2012082800957Plate · brokenCOCKPIT ENTRY KICKPLATE FR-39.00 LOWER FLANGE IS BROKEN. MATCH DRILLED NEW KICK PLATE IAW SRM 51-40-07-02-01. DEBURRED, ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED NEW KICK PANEL IAW SRM 51-42-05-02-01.Aug 28, 2012 · N409QX · Bombdr DHC8402 · Fixed Inner DoorsSDR QXEA2012082700958Seat Track · corrodedLT INBD SEAT TRACK HAS CORROSION FROM FR 644-664. BLENDED CORROSION IAW RD 8/4-53-884. BLENDS FOUND BEYOND LIMITS IAW RD. REMOVED SEAT TRACK IAW 51-42-05-02-01. MATCH DRILLED NEW SEAT TRACK IAW SRM 51-42-07-02-01. INSTALLED SEAT TRACK IAW SRM 51-42-05-02-Aug 28, 2012 · N409QX · Bombdr DHC8402 · Fuselage, Seat/Cargo Attach FittingsSDR QXEA2012082700870Lamp · inoperativeF/A EMERGENCY LIGHT SWITCH INOPERATIVE. RELAMPED NORMAL BACKLIGHTING ON SWITCH, OPS CHECKED GOOD. RETURNED TO SERVICE.Aug 27, 2012 · N432QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012082700872Latch · brokenLATCHES FOR FLASHLIGHT AND LIFEVEST COMPARTMENT BENEATH THE FWD F/A SEAT WILL NOT LATCH. REPLACED INBD LATCH ON FLASHLIGHT/LIFEVEST COMPARTMENT BENEATH THE FWD. F/A SEAT AS REQ OP'S CHECKS GOOD. COMPARTMENT NOW LATCHES NORMAL, NO OTHER DEFECTS NOTED. RETURNAug 27, 2012 · N444QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012082700959Frame · corrodedFRAME 236 HAS CORROSION BETWEEN STR 32-29P. REMOVED FASTENERS AS NEEDED AND REMOVED CORROSION IAW RD 8/4-53-2344. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. INSTALLED 8 RIVETS IAW SRM 51-42-05-02-01. ALODINED, PRIMED, PAINTED AND APPLIED CPC IAW RD Aug 27, 2012 · N409QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012082600869Cover · loosePLASTIC EXIT SIGN COVER LOOSE ON DITCHING DAM. RESECURED PLASTIC EXIT SIGN COVER AS REQUIRED. NO FURTHER DEFECTS. RETURNED TO SERVICE.Aug 26, 2012 · N415QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012082600871Cover · missingTHE COVER FOR THE EMERGENCY LIGHTING SWITCH IS MISSING. BY THE FORWARD PAX DOOR. REPLACED SWITCH LIGHT COVER NO OTHER DEFECTS NOTED.Aug 26, 2012 · N403QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012082600903Support Angle · corroded6 IN AFT OF FRAME X1.0 ABOVE STRINGER 25P, CORRODED SUPPORT ANGLE. FOUND SUPPORT ANGLE TO BE OUT OF LIMITS IAW SRM 53-20-23-00-01. REMOVED SUPPORT ANGLE IAW SRM 51-42-05-02-01. RECEIVED NEW PART, MATCH DRILLED TO ACFT IAW SRM 51-40-07-02-01. INSTALLED NEW Aug 26, 2012 · N405QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012082600924Frame · corrodedFRAME X1.0 FLANGES BETWEEN STRS 31P-33 BUBBLING PAINT PROBABLE CORROSION. REMOVED FRAME IAW SRM 51-42-05-02-01. MATCH DRILLED NEW FRAME SECTION TO AC IAW SRM 51-40-07-02-01. INSTALLED FRAME, FRAME SPLICE IAW SRM 51-42-05-02-01. CONFIRMED REPAIR AREA CRACK Aug 26, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012082700926Frame · corrodedFRAME X698 FLANGES BETWEEN STRS 31P-32P BUBBLING PAINT PROBABLE CORROSION. CLEANED FRAME FLANGES IAW SRM 51-26-00-02-01. CORROSION FOUND ON PREVIOUS REPAIR, NO REPAIR ALLOWED AND OUT OF LIMITS IAW RD 8/4-53-2344. REMOVED PREVIOUS REPAIR IAW SRM 51-42-05-02-Aug 26, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012082600944Frame · corrodedFRAME X32.4, FLANGES BETWEEN STRS 28P-33 BUBBLING PAINT PROBABLE CORROSION. REMOVED FRAME SECTION IAW SRM 51-42-05-02-01. LOCATED AND DRILLED NEW FRAME SECTION IAW SRM 51-40-07-02-01. INSTALLED FRAME IAW SRM 51-42-05-02-01. PAINTED AND APPLIED CPC IAW SRM Aug 26, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012082500868Pcu · malfunctionedON LANDING, WHEN POWER LEVERS WERE BROUGHT TO DISC, THE NR 1 DID NOT GO INTO BETA, UNTIL JUST BEFORE STOPPING AT THE GATE THE POWER LEVERS WERE IN DISC THE ENTIRE TIME THE NR 1 PROP GROUND RANGE LIGHT DID NOT ILLUMINATE. THE ACFT PULLED TO THE RIGHT ON ROLL OAug 25, 2012 · N436QX · Bombdr DHC8402 · Propeller Controlling SystemSDR QXEA2012082500907Stop Fitting · out of limitsUPPER EMERGENCY EXIT DOOR BOTH LOWER INTERCONNECTION STOPS ARE WORN. BLENDED STOPS IAW SRM 51-14-00-02-01 AND FOUND TO BE OUT OF LIMITS. REMOVED STOP FITTING ITEM 140A REF IPC 52-22-00 FIG 1, REF AMM 52-22-00-820-801. REPLACED STOP FITTING REF AMM 52-22-00-Aug 25, 2012 · N405QX · Bombdr DHC8402 · Emergency ExitsSDR QXEA2012082500916Access Panel · corrodedPOSSIBLE CORROSION ON RT WING SKIN FUEL ACCESS PANEL LANDING MATING SURFACE FOR PANEL 621BT. REMOVED CORROSION IAW RD 8/4-57-441. MIN REMAINING THICKNESS .173", CONFIRMED AFFECTED AREA CRACK FREE REF 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. PANEL LAAug 25, 2012 · N409QX · Bombdr DHC8402 · Wing, Plate/SkinSDR QXEA2012082600925Stringer · corrodedSTRINGER 30P BETWEEN FRAMES X-39 TO X 49.5 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. CLEANED IAW SRM 51-26-00-02-03. CORROSION FOUND LIMITED TO Z-JOINT AND IS OUT OF LIMITS IAW SRM 53-10-33-01-01. MATCH DRILLED NEAug 25, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012082500927Stringer · corrodedSTRINGER 27S BETWEEN FRAMES X-39 TO 49.5 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. CLEANED STRINGER IAW SRM 51-26-00-02-03 AND FOUND Z-JOINT TO BE OUT OF LIMITS DUE TO CORROSION IAW SRM 53-10-33-00-01. NO DAMAGE AAug 25, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012082500929Web · corrodedVERTICAL WEB AT STATION 6.700 HAS CORROSION AROUND NUTPLATES AROUND TORQUE TUBE CUTOUT. RECEIVED NEW WEB, MATCH DRILLED TO ACFT AND TRANSFERRED BRACKETS AND ANGLES IAW SRM 51-40-07-02-01 AND 51-40-05-02-01.Aug 25, 2012 · N405QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012082500937Structure · corrodedLT NACELLE AFT UPPER EMS STRUT A4 HAS AREAS OF CORROSION APPROX 8" FROM FWD END. SMOOTHED DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 8.2.1.1, REV 14. MATERIAL LOSS WITHIN LIMITS IAW RD 8/4-54-1041. PERFORMED DVI IAW RD 8/4-Aug 25, 2012 · N405QX · Bombdr DHC8402 · Nacelle/Pylon, Main FrameSDR QXEA2012082500962Access Panel · corrodedPOSSIBLE CORROSION ON LT WING SKIN FUEL ACCESS LANDING MATING SURFACE FOR PANEL 522CT. REMOVED CORROSION IAW RD 8/4-57-441. MIN REMAINING THICKNESS .180, CONFIRMED CRACK FREE AREA REF 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. FOUND IN LIMITS IAW SRM Aug 25, 2012 · N409QX · Bombdr DHC8402 · Wing, Plate/SkinSDR QXEA2012082400873Glowstrip · looseFLOOR GLOWSTRIP NEAR FWD CABIN DOOR LOOSE. SECURED GLOW STRIP NEAR FWD CABIN DOOR , NO FURTHER DEFECTS NOTED. RETURNED TO SERVICE.Aug 24, 2012 · N445QX · Bombdr DHC8402 · Emergency EquipmentSDR QXEA2012082400891Floor Support · corrodedUNDERFLOOR CROSSOVER PANEL FRAMES FOR AND AFT STARBOARD SIDE SHOWS SURFACE CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. FOUND TO BE IN LIMITS IAW RD 8/4-53-4719. COMPLIED WITH RD 8/4-53-4719.Aug 24, 2012 · N405QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012082400894Frame · corrodedFRAME X71.2 FLANGES BETWEEN STRS 29S-33 BUBBLING PAINT/ PROBABLE CORROSION. REMOVED RIVETS AS NECESSARY AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .026" REF NTM 51-00-04-910-801 PT 1. VERIFIED FRAME FLANGEAug 24, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Frame
Back to Pratt & Whitney Canada PW150A