Pratt & Whitney Canada PW150A

Service difficulty reports · 3,094

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE engine_model_key = 'PW150A'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR QXEA2012071000671Receptacle · wornLEFT HOT JUG IN GALLEY HAS A ELECTRICAL BURNING SMELL COMING FROM IT. FOUND LT AFT GALLEY MAPCO CONNECTOR TO HAVE SIGNS OF WEAR WHERE PLUG CONNECTS MAPCO, AS WELL AS BURN MARKS ON BACKSIDE OF CONNECTOR. R & R LT MAPCO CONNECTOR AND LT MAPCO. NO BURNING ELECJul 10, 2012 · N438QX · Bombdr DHC8402 · Equipment/Furnishings WiringSDR QXEA2012071000672O-Ring · leakingFOUND A FUEL LEAK ON THE NR 2 ENGINE AT THE FMU TRANSFER TUBES. REPLACED THE O-RING ON THE TRANSFER TUBE IAW AMM TASK 73-21-06-000-801 AND 73-21-06-400-801. RETURNED TO SERVICE.Jul 10, 2012 · N400QX · Bombdr DHC8401 · Fuel Controlling SystemSDR QXEA2012071000657Cover · damagedEMERGENCY LIGHT AT RT FWD EMERGENCY DOOR AFT STRIP HAS LENS COVER MISSING AND STRIP HAS SPIDER WEB CRACKING FOR APPROX 15" FROM INBD SECTION TO MID AN 5" SECTION AT OTBD EDGE. REMOVED UNSERVICEABLE AISLE EMERGENCY LIGHTS IAW AMM 33-51-16-000-801 AND INSTALLEDJul 10, 2012 · N406QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012071000680Stringer · corrodedSTRINGER 24P HAS CORROSION AND CORRODED RIVETS BETWEEN STA X216.000 AND X281.000. CLEANED STRINGER AND REMOVED RIVETS IAW SRM 51-26-00-02-01, 51-42-05-02-01, AND 51-21-00-00-02. BLENDED CORROSION IAW SRM 51-21-00-00-02. VERIFIED CRACK FREE IAW NTM 51-00-06-Jul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Longeron/StringerSDR QXEA2012071000687Frame · corrodedFRAME X258.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 31S AND 33. REMOVED 10 RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .038" REF NTM 51-00-04-910-801 PT 1. CONFIRMED AFFECTED AREA CRACK FJul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012070900647Governor · malfunctionedNR 2 PROPELLER SLOW TO COME OUT OF FEATHER, TAKES APPROX 10 SECONDS LONGER THAN NR 1, OVERALL TIME UNKNOWN. PERFORMED TROUBLESHOOTING IAW FIM TASK NR 61-20-00-810-803, STEPS 1-5A (7). INTERROGATED CDS AND PEC FOR FAULT CODES. NO FAULT CODES PRESENT. R & R Jul 9, 2012 · N418QX · Bombdr DHC8402 · Propeller Controlling SystemSDR QXEA2012070900636Floor Support · corrodedAFT BAGGAGE COMPARTMENT UNDER FLOOR SUPPORT ABOVE STRINGER 31P BETWEEN STA X783.100 AND X810.000 HAS CORROSION ON LOWER FLANGE TOP AND BOTTOM SURFACES. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .066 REF NTM 51-00-04-910-801. CONFIRMEJul 9, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012070900682Floor Support · corrodedFLOORBOARD SUPPORT CHANNEL 14" INBD OF FWD PAX DOOR ENTRY HAS AREAS OF CORROSION BETWEEN STA X1.00 AND X32.400 TOP AND BOTTOM SURFACES. REMOVED SUPPORT CHANNEL FOM IAW SRM 51-42-05-02-01. BLENDED OUT CORROSION IAW SRM 51-21-00-00-01. FOUND TO BE OUT OF LIMIJul 9, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR CA120823008Actuator · failed(CAN) NR 2 ENGINE OIL TEMP HIGH. MAINTENANCE FOUND ACOC DOOR ACTUATOR INOPERATIVE. ACTUATOR REPLACED.Jul 9, 2012 · Bombdr DHC8400 · Engine Oil CoolerSDR QXEA2012070800629Angle · corrodedUNDER FLOOR STUB FRAME RE-ENFORCEMENT ANGLE AT APPROX STA X24.000 BELOW FWD PAX DOOR OPENING HAS CORROSION BETWEEN STRINGERS 23P AND 25P. REMOVED CORRODED ANGLE IAW SRM 51-42-05-02-01. MATCH DRILLED NEW ANGLE IAW SRM 51-40-07-02-01. TREATED, PRIMED AND INSTJul 8, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR CA120709004Bevel Gear · failed(CAN) DURING BRAKING AFTER TOUCH DOWN THE FOOT PEDALS OF CM2 MOVED TO FULL FORWARD INADVERTENTLY. REMOVED RUDDER PEDAL. ADJUST MECHANISM ACC AMM 27-21-02-000-801 REV 38 FOR INVESTIGATION. FOUND BEVEL GEAR ON CM2 UNSERVICEABLE. BEVEL GEAR CM2 REPLACED PN R3000Jul 8, 2012 · Bombdr DHC8400 · Stabilizer Control SystemSDR QXEA2012070700593Propeller · malfunctionedNR 1 PROPELLER WILL NOT MX GROUND UNFEATHER WITHOUT BLADE BALANCE ASSISTANCE. GROUND RAN ENGINE, MOVED CLA FOR NR 1 PROP SEVERAL TIMES IN AND OUT OF FEATHER POSITION. AFTER SHUTDOWN UNFEATHERED NR 1 PROP IN GROUND MX MODE. PROP UNFEATHERED WITHOUT ASSISTANJul 7, 2012 · N448QX · Bombdr DHC8402 · Propeller Controlling SystemSDR QXEA2012070600600Frame · corrodedFRAME X32.400 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 30S AND 32S. REMOVED RIVET FOM AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .039" REF NTM 51-00-04-910-801 PT 1. CONFIRMED AFFECTED AREA CRACK FREJul 6, 2012 · N408QX · Bombdr DHC8402 · Fuselage Main, FrameSDR CA120801004Governor · failed(CAN) DURING THE APPROACH PHASE/1500AGL, 160 KT, FLAPS 15, AFTER DESELECTED THE REDUCE NP BUTTON WITH CL ON MAX 1020. THE CREW NOTICED THAT THE TQ OF ENG NR 1 WAS 38 PERCENT AND NP APPROXIMATELY 500 RPM. THE CREW WAS CONTINUING LANDING PROCEDURE. ON GROUND EJul 5, 2012 · Bombdr DHC8400 · Propeller GovernorSDR CA120823006Attach Bracket · unsecure(CAN) AN ACFT EXPERIENCED AN AILERON SYS LIMITED TRAVEL EVENT. UPON INSPECTION, THE AILERON QUADRANT AFT SECONDARY STOP BRACKET ATTACHING HARDWARE WAS FOUND UNSECURED AND IN CONTACT WITH THE AILERON QUADRANT CABLE GUIDE BRACKET, IPC 27-12-01 ITEM 190. THE STOJul 5, 2012 · Bombdr DHC8400 · Wing, Attach FittingsSDR QXEA2012070300594Warning Light · false activationFAULT LIGHT ILLUMINATED ON CABIN ALTITUDE CONTROL PANEL. AFTER CONDUCTING CHECK LIST, LIGHT EXTINGUISHED. DIVERTED AND ACCOMPLISHED UNEVENTFUL LANDING. COMPLIED WITH FIM TASK 21-30-00-810-802. CDS SHOWS FAULTS; AFT OUTFLOW VALVE FAIL AND CPC/OF VALVE DATA FAJul 3, 2012 · N444QX · Bombdr DHC8402 · Cabin Pressure Control SystemSDR QXEA2012070300596Stop Fitting · wornUPPER EMERGENCY EXIT HAS WEAR ON BOTH LOWER MAIN STOPS. REMOVED STOPS TO REPLACE IAW SRM 51-41-00-00-01. INSTALLED NEW STOPS IAW SRM 51-41-00-00-01 AND AMM 20-10-01-430-801.Jul 3, 2012 · N404QX · Bombdr DHC8402 · Emergency ExitsSDR QXEA2012070200645Floor Support · corrodedFLOORBOARD SUPPORT CHANNEL 14" INBD OF FWD PAX DOOR ENTRY HAS AREAS OF CORROSION BETWEEN STA X1.00 AND X32.400 TOP BOTTOM SURFACES. REMOVED SUPPORT CHANNEL FOR FOM IAW SRM 51-42-05-02-01. BLENDED OUT CORROSION IAW SRM 51-21-00-00-01. FOUND TO BE OUT OF LIMIJul 2, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012063000592Coffeemaker · contaminatedAFT F/A REPORTS AN ODOR IN AFT CABIN. INSPECTED AFT CABIN. CONFIRMED ODOR, BOTH MAPCO`S ON. FOUND RUBBER BAND ON TOP OF MAPCO HANDLE. REMOVED RT MAPCO. COULD NOT DETECT ODOR. R & R RIGHT MAPCO. OPS CHECKED GOOD. COMPLIED WITH AIR CONTAMINATION CHECKLIST.Jun 30, 2012 · N447QX · Bombdr DHC8402 · Buffet/GalleysSDR QXEA2012063000644Arm · chafedAFT RT SERVICE DOOR MAIN HINGE ARM IS CHAFED ALONG LOWER EDGE. SMOOTHED DAMAGE IAW SRM 51-14-00-02-04. MAPPED DAMAGED AREA, MAXIMUM MATERIAL LOSS OF .022" CONFIRMED BLENDED AREA CRACK FREE REF NTM 51-00-06-910-801, PT 1. MATERIAL LOSS FOUND TO BE WITHIN Jun 30, 2012 · N408QX · Bombdr DHC8401 · Service DoorsSDR CA120702013Engine · making metal(CAN) DURING REVENUE FLIGHT, ON DESCENT TO DESTINATION, THE ENGINE SHUTDOWN WITHOUT ANY PILOT INPUT. AN UNEVENTFUL SINGLE-ENGINE LANDING WAS ACCOMPLISHED. POST-FLIGHT INSPECTION REVEALED METAL ON THE TURBOMACHINE CHIP DETECTOR.Jun 29, 2012 · Bombdr DHC8400 · Engine (Turbine/Turboprop)SDR QXEA2012062800579Frame · corrodedFUSELAGE FRAME X71.2 LOWER FLANGE HAS CORROSION BETWEEN STRINGER 28S AND 29S. REMOVED CORROSION IAW SRM 51-21-00-00-02. FLANGE FOUND OUT OF LIMITS IAW RD 8/4-53-2344. CUT FRAME FLANGE IAW RD 8/4-53-017. CONFIRMED FRAME CRACK FREE AFTER FLANGE REMOVED USINGJun 28, 2012 · N404QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012062800558Frame · corrodedFRAME AT X176.000, LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 31P AND 32P. REMOVED RIVETS AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .039, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 AND 51-00-0Jun 28, 2012 · N408QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012062800559Frame · corrodedFRAME X196.000, LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 31P AND 32P. REMOVED AND BLENDED CORROSION. REMOVED RIVETS IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .039", CONFIRMED CRACK FREE IN AFFECTED AREA REF NTM 51-00-04-Jun 28, 2012 · N408QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012062800560Stringer · corrodedSTRINGER 31P HAS CORROSION BETWEEN STA X281.000 AND X301.000. REMOVED 7 RIVETS AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .080", CONFIRMED CRACK FREE IN AFFECTED AREA REF NTM 51-00-04-910-801 AND 51-00-06-9Jun 28, 2012 · N408QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012062700577Frame · corrodedFUSELAGE FRAME X19.400 LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 28S AND 33. REMOVED RIVETS IAW RD 8/4-53-2344 AND BLENDED CORROSION IAW SRM 51-21-00-00-02. REMOVED FLOORBOARD SUPPORT RAIL FRAME IAW SRM 51-42-05-02-01. MATCH DRILLED NEW FRAME IAW SRM 51-Jun 27, 2012 · N404QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012062700586Actuator · failedON CLIMB OUT NR 2 ENGINE OIL TEMP CLIMBED TO THE RED ARC TO 109 C FOR 4 MINUTES. RAN THE EMERGENCY CHECKLIST, INCREASED AIRSPEED, DECREASED POWER ON NR 2 ENGINE GOT TEMPERATURE BELOW 90 C FOR REST OF FLIGHT UNTIL TAXI IN. TEMPERATURE WENT BACK UP TO 104 C DUJun 27, 2012 · N409QX · Bombdr DHC8402 · Engine Oil CoolerSDR CA120628002Wire Harness · damaged(CAN) LDG GEAR INOPERATIVE CAUTION LIGHT ON DURING TAXI TO RWY. RETURNED TO PARKING POSITION AND ACFT HANDED OVER TO MAINTENANCE. MAINTENANCE FOUND, PSEU READOUT SHOWED FAULT OPEN SENSOR. PROXY SENSOR CHECKED VIA PSEU INTERFACE AND FOUND INTERMITTENT CONTACJun 27, 2012 · Bombdr DHC8400 · Landing Gear System WiringSDR QXEA2012062400548Stringer · corrodedSTRINGER 31P HAS CORROSION BETWEEN STA X39.00 AND X -18.250. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .075' CONFIRMED AREA CRACK FREE REF NTM 51-00-04-910-801 AND 51-00-06-910-801 PT 1. FOUND TO BE IN LIMITS IAW RD 8/4-53-4576.Jun 24, 2012 · N404QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012062300531Computer · malfunctionedAUTOFEATHER TEST WILL NOT FINISH BOTH SIDES SHOW "A/F TEST ABORT". FOUND FAULT CODE IN CDS NR 2 PROP 30B. COMPLIED WITH FIM TASK 61-20-01-810-816. DETERMINED THE PEC HARD FAILED. R & R NR 2 PEC IAW AMM TASK 61-20-36-000-801, 61-20-36-400-801. OP'S CHECKED GJun 23, 2012 · N407QX · Bombdr DHC8402 · Propeller Controlling SystemSDR CA120626005Proximity Sensor · erratic(CAN) ON GEAR RETRACTION LANDING GEAR INOPERATIVE CAUTION LIGHT ILLUMINATED AS WELL AS NOSE DOOR DOWN DOOR LIGHT ILLUMINATED. QRH COMPLIED WITH ALTERNATE GEAR EXTENSION NORMAL LANDING. IAW FIM 32-10-00-810-801 AND 32-73-33-810-808. DATA RETREIVED FROM PSEU Jun 23, 2012 · Bombdr DHC8400 · Landing Gear Position and WarningSDR CA120626002Power Unit · malfunctioned(CAN) ACFT WAS COMPLETING A GO AROUND DUE FLAP ISSUE. CAPT ADVISED OF A FLAP POWER CAUTION, PAN DECLARED, ACFT DID A 2ND GO AROUND AND PAX ADVISED LANDING MAY BE FIRMER AND FASTER THAN USUAL. NO ADVERSE PAX REACTION. ACFT LANDED WITHOUT INCIDENT" MAINTENANJun 22, 2012 · Bombdr DHC8400 · Trailing Edge Flap Control SystemSDR QXEA2012062100526Mount Strut · gougedRIGHT ENGINE AFT MOUNT STRUT A8 HAS GOUGES ON FWD OTBD END OF TUBE. SMOOTHED GOUGES IAW SRM 51-14-00-02-04. CONFIRMED BLEND CRACK FREE REF NTM 8.2.1.1. BLENDED AREA FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00-02-04. COMPLIED WITH PERMANENT ALLOWANCE FOR CONJun 21, 2012 · N404QX · Bombdr DHC8402 · Engine Mount SectionSDR CA120706001Generator · failed(CAN) DURING FLIGHT, THE CREW HAS NOTICED DC GEN NR 1 CAUTION LIGHT ON. AFTER LANDING THE NR 1 DC GENERATOR AND ENGINE AREA WAS INSPECTED. THE GENERATOR WAS FOUND TOTALLY DESTROYED. ALSO THE WHOLE NACELLE WAS CONTAMINATED WITH GENERATOR PARTS. REMOVED THE Jun 21, 2012 · Bombdr DHC8400 · AC Generator-AlternatorSDR CA120626004Transducer · failed(CAN) PILOT CALLED IN AFTER RETURNING TO GATE FROM ABORTED TAKEOFF. REPORTED THAT HE GOT THE ANTI-SKID LIGHT ON AT 105 KNOTS DURING TAKEOFF. ALSO REPORTED THAT DURING SLOW DOWN THE LIGHT STAYED ILLUM UNTIL 40 KNOTS AND THEN WENT OUT. FELT NORMAL BRAKING DURJun 18, 2012 · Bombdr DHC8400 · Landing Gear Brake SystemSDR QXEA2012061700469Actuator · malfunctionedDURING CLIMBOUT, NR 2 FUEL TEMP ROSE TO 75 DEG C FOLLOWED E/A CHECKLIST. TEMP DID NOT STAY IN NORMAL RANGE WITHOUT AUX PUMP ON.AND LEVEL FLIGHT. DURING CRUISE TEMP ROSE TO 73 DEG C WITH AUX PUMP ON. THEN SETTLED AT 68 DEG C WITH AUX PU820100-3-007 OFF DURINJun 17, 2012 · N416QX · Bombdr DHC8402 · Engine Fuel DistributionSDR CA120622004Tire · leaking(CAN) AFTER LANDING, IT WAS NOTICED THAT THE NR 3 MAIN WHEEL TIRE WAS FLAT. THE NR 3 & 4 MAIN WHEEL ASSEMBLIES WERE REPLACED & THE ACFT RETURNED TO SERVICE. WHEEL ASSEMBLY PN 3-1573-1, SN 2560. TIRE PN DR0231T & SN 11357195. WHEEL TSR 547, CSR 378. ACFT TJun 15, 2012 · Bombdr DHC8400 · TireSDR CA120704008Control Panel · malfunctioned(CAN) RT MLG SHOWS DOWN AND LOCK AFTER GEAR RETRACTION. MAINTENANCE REPLACED LANDING GEAR CONTROL PANEL. THEY DISCOVERED THAT THE RETAINING CLIP, WIRE FOR A LAMP SOCKET ON THE LANDING GEAR CONTROL PANEL WAS DISLODGED AND WAS CAUSING A SHORT.Jun 15, 2012 · Bombdr DHC8400 · Landing Gear Retraction/Extension SystemSDR CA120626011Cylinder · cracked(CAN) DURING GENERAL INSPECTION, A CRACK WAS FOUND ON THE CENTERING ACTUATOR MOUNTING FLANGE OF THE INNER CYLINDER OF THE NLG SHOCK STRUT. THE CAUSE FOR THIS DEFECT IS UNKNOWN SO FAR. AFFECTED NLG SHOCK STRUT REPLACED. INNER CYLINDER OF NLG SHOCK STRUT WAS Jun 13, 2012 · Bombdr DHC8400 · Nose/Tail Landing Gear Strut/AxleSDR QXEA2012061100450Bulkhead Web · corrodedFWD DRAFT BULKHEAD SUPPORT WEB AT STA X32.400 HAS AREAS OF CORROSION. REMOVED FWD BULKHEAD SUPPORT WEB IAW SRM 51-40-07-02-01. MATCH DRILLED AND PREPPED SUPPORT WEB FOR INSTALL IAW SRM 51-40-07-02-01 AND 51-42-05-02-01. INSTALLED NEW SUPPORT WEB IAW SRM 51-Jun 11, 2012 · N404QX · Bombdr DHC8402 · Fuselage Main, BulkheadSDR CA120704006Transducer · failed(CAN) NR 2 ENGINE OIL PRESSURE INTERMITTENTLY HIGH 72-106, PSI DURING CLIMB. INTERROGATED CDS. FOUND FAULT CODE 944 ON NR 2 ENGINE CHANNEL A AND B IAW FIM TASK 79-20-00-810-886, PARA 4A. CLEARED FAULT CODE AND GROUND RAN ACFT IAW AMM TASK 71-00-00-768-805. Jun 11, 2012 · Bombdr DHC8400 · Engine Oil PressureSDR CA120611004Bypass Valve · defective(CAN) AIR TURN BACK DUE TO ENGINE OIL TEMPERATURE INCREASING TO 107 CENTIGRADE DEGREES DURING CLIMB. CREW MEMBER DID QRH CHECKLIST AND NOTIFIED MOC. THE CREW WAS ADVISED TO REDUCE TORQUE AND DESCEND. THE OIL BY-PASS VALVE AND THERMAL ACTUATOR FUEL HEATER WAJun 10, 2012 · Bombdr DHC8400 · Engine Oil CoolerSDR CA120619006Unknown · haze(CAN) DURING CLIMB, A SMOKE MIST ENTERED THE CABIN, ENG BLEEDS WERE SHUT OFF & THE ACFT WAS RETURNED TO THE DEPARTURE POINT, WHERE AN UNEVENTFUL LANDING WAS MADE. ENGINE REPLACED.Jun 9, 2012 · Bombdr DHC8400 · Engine (Turbine/Turboprop)SDR QXEA2012060600762Seat Track · corrodedLEFT INBD SEAT TRACK NR 6 IS CORRODED AFT OF STA 216. REMOVED CORROSION IAW RD 8/4-53-884, REV 3. BLENDED AREA FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884 ISSUE NR 3. CONFIRMED BLENDED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1. PROTECTED BARE METAL IJun 6, 2012 · N404QX · Bombdr DHC8402 · Fuselage, Seat/Cargo Attach FittingsSDR CA120626003Indicator · malfunctioned(CAN) TAKEOFF WARNING WAS ACTIVATED DURING T/O ROLL, AROUND 30KT. ABORTED TAKEOFF. TROUBLESHOOTING CONFIRMED THE SNAG DUPLICATED WITH OPERATIONAL CHECK, T/O WARNING ACTIVATED WHILE THE ELEVATOR TRIM IN T/O RANGE. ELEVATOR TRIM INDICATOR WAS REPLACED, THE AIRCJun 6, 2012 · Bombdr DHC8400 · Elevator Tab Control SystemSDR CA120613002Tru · overheated(CAN) DURING A DAILY INSPECTION, NOTICED AN ELECTRICAL BURN ODOR IN THE COCKPIT. FOUND THAT BOTH FANS ON BOTH TRANSFORMATOR RECTIFIER UNITS WERE NOT OPERATING RESULTING IN THE NR 1 AND 2 TRUS RUNNING HOT, AND THE NR 2 SMELLING BURNED WITHOUT HAVING ANY CAUTIOJun 4, 2012 · Bombdr DHC8400 · DC Rectifier/ConverterSDR CA120619003Engine · making metal(CAN) WHILE POWERING UP FOR TAKEOFF, THE NR 1 ENG OIL PRESSURE & FADEC WARNINGS CAME ON WITH OIL PRESSURE INDICATING 0. THE TAKEOFF WAS ABORTED. POST EVENT INSPECTION FOUND HEAVY CONTAMINATION OF THE CHIP DETECTOR & OIL FILTER WITH METAL CHIPS. ENG IS BEINGJun 4, 2012 · Bombdr DHC8401 · Engine (Turbine/Turboprop)SDR QXEA2012060300418Seal · leakingAFTER TAKEOFF, NR 2 ENGINE OIL PRESSURE DECREASED TO 50 PSI VARING TO 60 PSI. PROP WAS FEATHERED AND RETURN TO FIELD. ALL OTHER ENGINE INDICATORS REMAINED NORMAL. LANDING UNEVENTFUL. FOUND EVIDENCE OF OIL LEAK IN DRAIN LINE FROM VARIABLE DELIVERS HYD PUMPJun 3, 2012 · N423QX · Bombdr DHC8402 · Turbine Engine Oil SystemSDR CA120626014Engine · malfunctioned(CAN) DURING T/O ROLL AROUND 50 TO 60 KT, THE CREW HEARD A NOISE, REFERRED TO AS A "BANG" FROM THE LT OF THE ACFT WITH CORRESPONDING MOMENTARY INCREASE IN ENGINE NR 1 TQ FROM 90 TO 93 THEN BACK TO 90 PERCENT IN ABOUT 1 SEC. NO ANOMALY IN ENGINE PARAMETERS NORJun 3, 2012 · Bombdr DHC8400 · Engine (Turbine/Turboprop)SDR QXEA2012060200412Propeller · vibrationIN CRUISE FLIGHT, AT FL 250, NR 1 ENGINE HAD A VIBRATION STARTING AT 57 PERCENT TORQUE AND INCREASED AS TORQUE INCREASED. VIBRATION STOPPED BELOW 57 PERCENT TORQUE. ALL OTHER ENG INDICATIONS NORMAL. DIVERTED FLIGHT AND ACCOMPLISHED AN UNEVENTFUL LANDING. RJun 2, 2012 · N405QX · Bombdr DHC8402 · Propeller Assembly
Back to Pratt & Whitney Canada PW150A