SDR DL72S982664Compressor · stalledNR 2 ENGINE COMPRESSOR STALLS AND VIBRATIONS ON CLIMBOUT. ACFT RETURNED TO DFW. NR 2 ENGINE CHANGED.SDR 98UAL900620Battery Pack · dischargedEMERGENCY LIGHT AT AFT CARGO DOOR INOPERATIVE. *S/D* REPLACED BATTERY PACK AND LIGHT CHECKED OK.SDR 98UAL900621Battery Pack · dischargedFLOOR LIGHTING INOPERATIVE FROM SEAT ROW 26 TO 28. *S/D* REPLACED BATTERY PACK, EEL STRIP AND LAMPS.SDR 98UAL900614Indicator · malfunctionedNR 1 AND 2 MAIN FUEL QUANTITY ERRATIC. CREW NOTED ABOUT 3 UNITS OF RUDDER TRIM APPLIED. FLIGHT DIVERTED TO RNO DUE TO POSSIBLE FUEL IMBALANCE. *S/D* CHECKED THE SYSTEM AND FOUND NO PROBLEMS. REPLACED THE INDICATOR DUE TO READING UNSTABLE.SDR 98UAL900610Buffet · defectiveCOFFEEMAKER IN AFT GALLEY SMOKING. *S/D* THE COFFEEMAKER WAS CHECKED FOR PROPER OPERATION. NO SMOKE WAS PRESENT WITH POWER TO THE GALLEY OFF. THE BUFFET WAS REPLACED AT THE TERMINATION OF THE FLIGHT.SDR 98UAL900611Throttle · out of adjustABORTED TAKEOFF AT 100 KNOTS DUE TO NR 3 ENGINE LOW EPR (1.8) WITH THROTTLE 2-3 INCHES BEYOND NR 1 AND 2 ENGINES. RPM WAS GOOD AT 99 PERCENT AND FUEL FLOW MATCHED NR 1 AND 2 ENGINES. *S/D* ADJUSTED RIG ON NR 3 THROTTLE. CHECKED INLET AND EXHAUST. CHECKED OPSDR CA990111029Frame · cracked(CAN) FRAME DAMAGED AT STA 1166 LT SIDE OF A/C 4 INCHES ABOVE FLOOR LEVEL BY CARGO PALLET. BENT BACK AND FLANGE TORN AND 1.5 INCH CRACK IN FRAME. REPAIRED. PART TC: 37,619.SDR TWAA9819801Fuel Control · malfunctionedTHE LEFT ENGINE WOULD NOT RESPOND TO THROTTLE MOVEMENT. THE LT ENGINE WAS SHUT DOWN AND FLIGHT RETURNED TO STL. REPLACED THE JFC, (P/N 743602-4), AND ENGINE FUEL PUMP, (P/N 378200). CHECK-C 3-22-98 STL.SDR SWAA983111Compressor · bird strikeINJESTED BIRD INTO NR 1 ENGINE ON TAKEOFF. ENGINE OPERATED OK, CABIN FILLED WITH BIRD SMELL AND SMOKE. AIRCRAFT RETURNED TO OAK. NR 1 ENG FAN SECTION REQUIRES REPLACEMENT AND BORESCOPE REQUIRED. FAN SECTION REPLACEMENT AND BORESCOPE COMPLIED WITH PER BOEINSDR 98UAL900602Controller · failedUNABLE TO STABILIZE CABIN PRESSURE. RETURNED TO FIELD. *S/D* THE PRESSURE SELECTOR PANEL AND THE CABIN PRESSURE CONTROLLER WERE REPLACED.SDR 98UAL900590Switch · intermittentNR 2 REVERSER NOT STOWED LIGHT CAME ON AT 100 KNOTS ON TAKEOFF. ABORTED TAKEOFF. *S/D* SUBSEQUENT TROUBLESHOOTING OR THE REVERSER OPERATION REVEALED WHAT APPEARED TO BE A BAD SWITCH ASSEMBLY. THE SWITCH WAS REPLACED AND THE FAILED UNIT BROUGHT INTO THE SHOP SDR 98UAL900593Slat · damagedLEADING EDGE SLAT NR 6 DID NOT RETRACT. VERIFIED FULL DOWN BY VISUAL CHECK. POSSIBLE BIRD STRIKE ON DEPARTURE FROM SMF. DIVERTED TO SFO. *S/D* SLAT DAMAGED BY BIRD STRIKE. REPLACED NR 6 SLAT, SYSTEM OPERATIONALLY CHECKED OK.SDR 98UAL9005916 Oil Pres Tube · crackedNR 1 ENGINE OIL QUANTITY INDICATOR BEGAN TO SHOW GRADUAL LOSS OF OIL EN ROUTE. ELECTED TO LAND AT SYR. *S/D* THE LOSS OF OIL WAS DUE TO A CRACK IN THE NR 6 BEARING OUTER INTERNAL OIL PRESSURE LINE AT THE BRAZE JOINT NEAR THE FIXED FERRULE. THE LINE WAS REPLASDR 98UAL900579Bushing · missingON TOUCHDOWN, RIGHT MAIN LANDING GEAR WARNING LIGHT CAME ON. FELT VIBRATION ON RIGHT SIDE. INITIATED A GO-AROUND. *S/D* FOUND RT MAIN LANDING GEAR DOWNLOCK SENSOR ACTUATOR MISSING BUSHING. REPLACED BUSHING AND PERFORMED DOWNLOCK SENSOR AND LANDING GEAR POSDR 98UAL900578Actuator · failedSTABILIZER WOULD NOT TRIM (ON PEDESTAL) AFT OF 4.5 UNITS ELECTRICALLY. RETURNED TO DEN. *S/D* REPLACED MAIN ELECTRIC STAB TRIM ACTUATOR, SYSTEM OPERATIONALLY CHECKED OK.SDR 98UAL900567Mechanism · wornFORWARD SERVICE DOOR LIGHT CAME ON. INSIDE D00R HANDLE POPS TOWARDS OPEN 3 TO 4 INCHES FROM LOCKED POSITION. TRIED TO PUSH HANDLE DOWN BUT IT POPPED BACK UP. DOOR 1R WAS ADJUSTED PER MM/OV 70-52-11-00. UPPER LATCH CAM WAS BACKED UP TWO SERRATIONS TO COMPENSDR 98UAL900556Coffeemaker · defectiveMINOR SMOKE IN AFT GALLEY. SUBMITTER STATES, SUSPECTED CAUSE WAS EITHER A LIGHT BULB OR A COFFEE MAKER. SUBSEQUENT INSPECTION SHOWED THAT THE COFFEE MAKER WAS DEFECTIVE. THE COFFEE MAKER WAS REPLACED AND CHECKED FOR PROPER OPERATION.SDR UPS98228229Fuel Pump · failedINSPECTION TYPE-N/A, CLIMBING OUT OF 700 FT AGL NR 1 ENGINE FAILED. CHECKLIST RUN ENGINE WAS IN RESTART ENVELOPE, RESTART ATTEMPT UNSUCCESSFUL OIL PRESS AND INDICATIONS NORMAL. REMOVED AND REPLACED NR 1 FUEL CONTROL AND FUEL PUMP PER MM 73-21-1 AND 73-11-1, SDR 98UAL900550Switch · failedIN CLIMB, LEADING EDGE AMBER LIGHT ILLUMINATED WITH FLAPS IN RETRACTED POSITION. TEST INDICATED NR 2 LEADING EDGE KRUGER FLAP IN TRANSIT LIGHT ON. RETURNED TO ORD. CHECKED OPERATION SEVERAL TIMES. NO DEFECT OF LIGHTS PROBLEMS FOUND. SUSPECT POSSIBLE ICE ASDR BJNA981102Hub · damagedHIT DEER ON LEFT ENGINE NACELLE DURING TAKEOFF ROLL (AT V1). REMOVED AND REPLACED NOSE COWL ASSY, NOSE BULLET ASSY PER PWMM 72-000-23. REMOVED AND REPLACED C1 FAN ASSY PER PWMM 72-30-0, PEFORMED TEST I AND G. REFERENCE GE ON WING SUPPORT SERVICE WORK ORDER SDR 98UAL900525Light · inopEEL LIGHTING INOPERATIVE FROM SEAT 10A TO FIRST CLASS.SDR 98UAL900522Light · malfunctionedAFTER TAKEOFF, NR 4 LEADING EDGE SLAT GREEN LIGHT REMAINS ON WITH SLATS RETRACTED. RETURNED TO DEN.SDR 98UAL900521Combustor · crackedNINE INCH CIRCUMFERENTIAL CRACK IN NR 5 COMBUSTION CHAMBER CAN OF NR 2 ENGINE. *S/D* SHOP INSPECTION OF THE NR 5 BURNER CAN REVEALED THE CRACK TO BE IN THE 2-3 LINER UNDER THE AIR SCOOP. CRACKING IN THIS AREA IS NOT UNCOMMON, ALTHOUGH AT 10,964 HOURS THE CRACSDR 98UAL900513Light · inopFORWARD CABIN CEILING EMERGENCY LIGHT INOPERATIVE.SDR 98UAL900512Light · failedON SHORT FINAL, FIRST OFFICER'S OVERHEAD MAP LIGHT POPPED AND SHOWERED THE FIRST OFFICER WITH SPARKS.SDR 98UAL900509Tube · leakingA-HYDRAULIC SYSTEM PRESSURE INDICATION ZERO. ENGINE 1 AND 2 PUMP LOW PRESSURE LIGHTS ON. LOST ALL A-SYSTEM HYDRAULICS DURING FLAP RETRACTION AFTER LANDING. *S/D* REPAIRED LEAKING HYD LINE AT NR 6 L/E SLAT ACTUATOR. OPS CK FOUND BOTH ACTUATOR ATTACH BRACKESDR 98UAL900510Light · inopFORWARD CABIN CEILING EMERGENCY LIGHT INOPERATIVE.SDR 98UAL900511Engine · malfunctionedNR 2 ENGINE EGT LIMITED DURING CLIMB. REDUCED THRUST TO 205 EPR TO KEEP EGT WITHIN LIMITS. RETURNED TO DEN.SDR 98UAL900505Throttle · bindingNR 3 ENGINE SHUT DOWN IN FLIGHT DUE TO BINDING THROTTLE.SDR 98UAL900595Structure · damagedRIGHT FUSELAGE DAMAGED BY TOW TRACTOR. DAMAGE BETWEEN BS 390 TO 470 FROM STRINGERS 23R TO 27R, WHICH WERE SEVERED. FRAMES AT STA 400, 420, 440 AND 460 WERE CRUSHED. THREE ADJACENT SKIN PANELS DAMAGED. SPLICE PLATE AT BS 440 AND BEAR STRAP FOR E & E DOOR SDR 98UAL900501Air Dist · odorDURING DESCENT, ELECTRICAL BURNING SMELL NOTICED IN COCKPIT INTERMITTENTLY. *S/D* MAINTENANCE INSPECTED COCKPIT, FORWARD ACCESSORY COMPARTMENT, E & E COMPARTMENT AND FOUND NO EVIDENCE OR ODOR OF BURNED WIRING OR EQUIPMENT. NO FURTHER PROBLEMS REPORTED.SDR 98UAL900502Control Mech · malfunctionedWHEN THE SPEED BRAKE IS DEPLOYED, AIRCRAFT BANKS TO THE LEFT EXCESSIVELY. AILERON TRIM SET AT 0. WHEN THE B-SYSTEM IS OFF, THE AIRCRAFT DOES NOT ROLL.SDR 98UAL900496Battery · dischargedAFT AIRSTAIR AND OVERWING EMERGENCY EXIT LIGHTS AT 17F DID NOT ILLUMINATE WHEN USED. REPLACED BATTERIES IN LIGHT UNIT.SDR 98UAL900484Actuator · failedNUMBER 6 LEADING EDGE FLAP WOULD NOT RETRACT FROM FULL-DOWN POSITION. NO CONTROL PROBLEMS REPORTED. RETURNED TO DEN. *S/D* REPLACED NR 6 LE FLAP ACTUATOR. SYSTEM OPS CHECKS OK.SDR 98UAL900492Wire · brokenFORWARD ENTRY DOOR LOWER EMERGENCY EXIT SIGN INOP. REPLACED EEL CABLE, OPS CHECKS OK.SDR DL73K982051Fuel Control · malfunctionedNR 1 ENGINE COMPRESSOR STALLS AT FL370. AC YAWED LT EACH TIME AND N1 AND F/FLOW GAUGES FLUXED. N1 GAUGE WOULD SPIKE 5PC DROP. 5 SPIKES AT 1 SECOND INTERVALS. FLT DIVERSION TO MCO. INSP ENG COMPRESSOR AND EXH WITH BOROSCOPE. NO TROUBLE FOUND. CKED PS3 FISDR DL72W981996Heat Valve · failedNR 3 ENGINE OIL TEMPERATURE ROSE TO YELLOW BAND RANGE. FOLLOWED POM PROCEDURES FOR HIGH OIL TEMPERATURE. SHUTDOWN NR 3 ENGINE ACCORDING TO CHECKLIST PROCEDURES. REPLACED NR 3 ENGINE FUEL HEAT VALVE. LEAK AND FUNCTION CHECKS OK. INSPECTED ENGINE FOR OIL TESDR 98UAL900476Switch · failed# 6 LEADING EDGE FLAP SHOWS AMBER LIGHT WHEN IN FULL UP POSITION ON SECOND OFFICERS PANEL AND ON FORWARD PANEL. RETURNED TO ORD. SUPPLEMENTAL DATA UPDATE REPLACED #6 LE FLAP SWITCH. SYSTEM OPERATES NORMAL.SDR 98UAL900469Battery Pack · dischargedBOTH OVERWING EXIT LIGHTS ON LEFT INTERIOR SIDE ARE INOPERATIVE. *S/D* REPLACED BATTERY PACK.SDR 98UAL900467Drive Motor · leakingAFTER DEPARTURE LOST HYDRAULIC SYSTEM A PRESSURE. CONTINUED TO ORD AND WAS TOWED TO THE GATE. *S/D* REPLACED HYD FLAP DRIVE MOTOR AND NR 1 AND NR 2 ENGINE DRIVEN HYDRAULIC PUMPS PRECAUTIONARY. ALSO, REPLACED CASE DRAIN AND PRESSURE FILTERS PER MAINTENANCE SDR SWAA982164Duct · failedAIR TURNBACK DUE TO NR 1 ENGINE OVERHEAT LIGHT ILLUMINATED AFTER TAKEOFF FROM BWI (NOTE ANY EPR SETTING ABOVE 1.75 CAUSED THE LIGHT TO RE-ILLUMINATE). AIRCRAFT MADE AN UNEVENTFUL LANDING. REMOVED AND REPLACED 13TH STAGE FUEL HEAT DUCTING PER BOEING MM. RAN SDR 98UAL900464Regulator · failedGOT AN OVER EXCITED ANNUNCIATOR LIGHT ON NR 1 SYSTEM. BUS BREAKER DID NOT TRIP. RESET BROUGHT GENERATORS BACK ON LINE FOR 5 MINUTES. AT TAKEOFF ANNUNCIATOR LIGHT CAME ON AGAIN. SYSTEM NR 1 BUS TIE TRIPPED SYSTEM 1 FOLLOWED BY LEFT PACK TRIP. TANK NR 1 AFTSDR DL72S981899P & D Valve · failedNR 3 ENG FAILED INITIALLY FELT SLIGHT SWERVE AND EPR DROPPED WHEN THE THROTTLE WAS ADVANCED. THE ENG CONTINUED TO SPOOL DOWN TO WINDMILLING. REPLACED P/D VALVE.SDR 98UAL900451Breaker · failedRETURNED TO GATE WITH ELECTRICAL PROBLEMS. FOUND BUS PROTECTION PANEL CIRCUIT BREAKER POPPED AND ELECTRICAL SMELL IN E & E COMPARTMENT. *S/D* REPLACED FAILED NR 3 GENERATOR BREAKER. ALSO, REPLACED BUS PROTECTION PANEL AND GENERATOR CONTROL UNITS PRECAUTIONSDR 98UAL900442Valve · failedRETURNED TO OKC DUE TO A HYDRAULIC SYSTEM INOPERATIVE. *S/D* REPLACED UPLOCK SEQUENCE VALVE. ACCOMPLISHED GEAR SWING, SYSTEM OPS CHECKS OK.SDR 98UAL900443Module · failedSTALL WARNING ON ROTATION WITH FIRST OFFICER'S STICK SHAKER. RETURNED TO ORD. *S/D* NR 2 STALL WARNING MODULE. REPLACED NR 2 STALL WARNING MODULE, OPS CHECK OK.SDR 98UAL900447Duct · failedWHEN ENGINE ANTI-ICE WAS SELECTED ON THE NR 2 COWL ANTI-ICE DUCT TEMPERATURE CLIMBED TO 230 DEGREES. BEFORE IT WAS SELECTED AN ACRID SMELL WAS EVIDENT IN THE COCKPIT AND CABIN.SDR 98UAL900446Battery · dischargedLEFT OVERWING FORWARD EMERGENCY LIGHT IS ILLUMINATED WHEN THE POWER IS OFF. *S/D* BATTERY CHARGE WAS FOUND TO BE LOW. BATTERY PACK WAS REPLACED AND CHECKED FOR PROPER OPERATION.SDR 98UAL900444Battery · dischargedAIRSTAIR AFT EMERGENCY EXIT LIGHT INOPERATIVE. *S/D* LIGHT ASSY WAS FOUND TO BE DISCHARGED. THE LIGHT ASSY WAS REPLACED AND CHECKED FOR PROPER OPERATION.SDR 98UAL900445Regulator · failedAT FLAP RETRACTION NR 3 STRUT OVERHEAT LIGHT CAME ON, LIGHT WENT OUT WHEN THROTTLE RETARDED. KEPT THROTTLE AT IDLE UNTIL LANDING. RETURNED TO ORD. *S/D* HIGH DUCT PRESSURE. REPLACED HIGH STAGE REGULATOR.
Back to Pratt & Whitney JT8D-15