Pratt & Whitney JT8D-15
Service difficulty reports · 2,710
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 97UAL900314Circuit Card · failedON GEAR RETRACTION SFO BOTH RED AND GREEN LIGHTS REMAINED ON. NO LIGHTS ON S/O PANEL. RECYCLED WITH ALL GREEN AND NO RED. RETRACTED GEAR A SECOND TIME, SAME RESULTS. THEN 5 TO 8 MINUTES LATER BOTH LIGHTS WENT OUT. MADE UNSCHEDULED LANDING DEN. *S/D* RESSDR 9707699987Epr Transmitter · malfunctionedAS TAKEOFF POWER WAS APPLIED, THE RIGHT ENGINE EPR INDICATION WOULD NOT REACH TARGET EPR. CREW ABORTED TAKEOFF AND RETURNED TO GATE. MAINTENANCE REPLACED THE RIGHT ENGINE EPR TRANSMITTER AND INDICATOR. OPERATIONAL CHECK OK. AIRCRAFT RETURNED TO SERVICE.SDR 97UAL900300Overheat Det · out of positionLOWER AFT BODY OVERHEAT LIGHT CAME ON IN FLIGHT FL370. DESCENDED DOWN TO FL 250 AND LIGHT WENT OUT APPROX 310 DURING THE DESCENT. *S/D* REPOSITIONED KEEL BEAM DETECTOR, REMOVED AND INSPECTED DUCT THAT RUNS THROUGH KEEL BEAM AND LEAK CHECKED. NO DEFECT NOTESDR 97UAL900301Transmitter · failedON TAKEOFF DURING FLAP RETRACTION, SPLIT FLAPS OCCURRED. O/B FLAPS FROZE AT 15 I/B, FLAPS CONTINUED RETRACTING. ALT FLAP EXTENSION PROCEDURE PERFORMED BUT L/E DEVICES WOULD NOT RETRACT. ALT FLAPS USED TO EXTEND FLAPS FOR NORMAL LAND PDX. *S/D* REPLACED LESDR 97UAL900302Seal · wornSMOKE IN CABIN AT DISPATCH TIME APU LOAD CONTROL VALVE WOULD NOT OPEN AFTERWARDS. SUPPLEMENTAL DATA UPDATE, SEALS ON THE OIL BREATHER FITTING HAD WORN AND OIL WAS LEAKING EXTERNALLY INTO THE EXHAUST. ALSO, THE AIR/OIL COMPRESSOR SEAL AND THE TURBINE SEAL WERSDR 97UAL900287Pack · smokingAIRCRAFT RETURNED TO GATE IN DEN WITH SMOKE IN CABIN FROM A OVERHEATED PACK. NR 3 BUS TIE TRIPPED (UNDEREXCITATION), ATTEMPTED RESET SUCCESSFUL. LT PACK OVERHEAT WITH GOOD INDICATION OF POWER DRAW WHEN PACK TURNED ON. *S/D* RESET LEFT PACK SWITCH, RAN ENGISDR 97UAL900294Connector · brokenEMERGENCY EXIT SIGN ABOVE RT FWD OVERWING EXIT HATCH IS LOOSE, DIRTY, OR STAYS ON WITH OVERHEAD PANEL SWITCH IN THE ARMED POSITION. EXIT LIGHT CAME LOOSE AND BROKE A WIRE. REPLACED THE FEMALE PLUG AND PINS FOR THE EMERGENCY SIGN. OVERWING EMERGENCY LIGHT RSDR 97UAL900275Oven Controller · inoperativeFWD GALLEY OVEN OVERHEATED AND PRODUCED SOME SMOKE. *S/D* REPLACED OVERHEATED OVEN AND CONTROLLER.SDR 97UAL900291Shutoff Valve · failedDIVERTED TO DEN, DUE TO A PRESSURIZATION PROBLEM AFTER TAKEOFF FROM COS. REPLACED LEFT PACK SHUTOFF VALVE. SYSTEM CHECKED NORMAL.SDR 97UAL900293Oil Seal · leakingDISPATCH MECHANIC NOTED SMOKE COMING FROM APU IN THE RT WHEEL WELL AREA AROUND EXHAUST DUCT. SUPPLEMENTAL DATA UPDATE, THE CAUSE OF THE SMOKE WAS BELIEVED TO BE RESIDUAL GLYCOL. HOWEVER, THE SEALS ON THE OIL BREATHER FITTING HAD WORN AND OIL WAS LEAKING EXTESDR 97UAL900274Acm · smokingRIGHT PACK OVERHEATED AND FILLED CABIN WITH SMOKE. REPLACED RIGHT AIR CYCLE MACHINE.SDR USVA49701Tube · crackedENGINE NR 3 SHUT DOWN DUE TO FIRE WARNING. FOUND NR 3 ENGINE BLEED AIR MANIFOLD TUBE SEPARATED AT FLANGE WHERE ATTACHED TO FUEL HEAT VALVE. REPAIRED FLANGE TO PIPE IAW PWA ENGINE MANUAL 72-09-71. OPS CHECKED FUEL HEAT VALVE. NO LEAK NOTED. (M)SDR 97UAL900273Hose · leakingLANDED OMA UNDER AMBER ALERT, DUE TO LOSS OF THE 'A' SYSTEM HYDRAULICS. FOUND RT ELEV PCU LINE LEAKING. REPLACED RIGHT ELEVATOR POWER CONTROL UNIT LINE AND SERVICED HYDRAULIC SYSTEM.SDR CA970422028Brake Assembly · worns(CAN) ON DEPARTURE AND LANDING CREW NOTED A VIBRATION FROM THE MAIN LANDING GEAR. ALSO ON APPROACH CREW HAD TO CYCLE GEAR TO GET GREEN NOSE LANDING GEAR LIGHT. MAIN WHEELS CHECKED FOR ROTATION AND SECURITY. ALSO NOSE LANDING GEAR RETRACTION SWITCH AND DOWN LOCSDR 97UAL900269Light · intermittentON FINAL APPROACH, AFTER GEAR DOWN, NO GREEN NOSE LIGHT INDICATION. RECYCLED GEAR, STILL NO GREEN LIGHT. ON ROLL OUT, GOT A RED DOORS LIGHT, THEN THE GREEN NOSE GEAR LIGHT CAME ON AND DOORS LIGHT WENT OUT. REPLACED NOSE GEAR GREEN INDICATOR LIGHT LENS CAP. SDR 97UAL900267Exhaust Shroud · smokingMECHANIC SAW SMOKE AROUND APU EXHAUST SHROUD AREA. AIRCRAFT INSPECTED IN AREA OF APU EXHAUST SHROUD. SMOKE DETERMINED TO BE BURN OFF OF RESIDUAL GLYCOL.SDR AU970464Seal · leaking(AUS) NO1 ENGINE NO9 COMBUSTION CAN FUEL INJECTOR NOZZLE SEAL LEAKING. INVESTIGATION FOUND THAT THE PROBLEM WAS CAUSED BY IMPROPER MAINTENANCE ACTIVITIES DURING NOZZLE OVERHAUL.PERSONNEL/MAINTENANCE ERROR.SDR AU970490Combustor · holed(AUS) NO1 ENGINE NO9 COMBUSTION CAN BURNT THROUGH AT FUEL NOZZLE NUTFACE. FOUND DURING BOROSCOPE INSPECTION. INVESTIGATION FOUND THAT THE PROBLEM WAS CAUSED BY DISCREPANCIES IN THE OVERHAUL OF THE FUEL NOZZLE ASSEMBLIES. PERSONNEL/MAINTENANCE ERROR.SDR 97UAL900268Power Cable · damagedEEL STRIP INOP ROW 13 THROUGH ROW 26. *S/D* REPLACED EEL SYSTEM POWER CABLES AT ROWS 16 AND 23. EEL LIGHTING SYSTEM OPERATES NORMALLY. CABLES DAMAGED PROBABLY DURING CARPET REPLACEMENTS.SDR 97UAL900254Tire · blownABORTED TAKEOFF AT 90 TO 100 KNOTS DUE TO NOSE TIRE CAP SEPARATION. *S/D* REPLACED BOTH NOSE WHEELS, NOSE TAXI LIGHT WIRE HARNESS, DENTED WHEEL WELL PANEL, HYDRAULIC LINE AND 5 BROKEN CLAMPS. REPAIRED FIBERGLASS FAIRING ON INSIDE OF RIGHT AFT NOSE GEAR DOORSDR 97UAL900255Light · inoperativeOVERHEAD CABIN EMERGENCY LIGHT FOR OVERWING EXIT INOP. *S/D* LIGHT ASSY REPLACED. EMERGENCY LIGHTING SYSTEM OPERATED NORMALLY.SDR 97UAL900249Battery Pack · failedLEFT OVERWING EXIT LIGHTS INOP, BOTH LIGHTS OVER EXIT DOORS. *S/D* BATTERY PACK FAILED. REPLACED BATTERY PACK.SDR 97UAL900245Light · inoperativeEMERGENCY EXIT LIGHTING INOPERABLE FROM ROW 20 AFT. REPLACED INOP EMERGENCY EXIT LIGHTING. OPERATION CHECKS NORMAL.SDR CALA9700353Lpt Shaft · fracturedA LOUD BOOM WAS HEARD AND THE AIRCRAFT SHUDDERED AFTER DEPARTURE WHILE PASSING BETWEEN 2000 AND 2500 FEET. THE NR 2 ENGINE N1 AND N2 DROPPED RAPIDLY WITH NO FUEL FLOW OR OIL PRESSURE INDICATED. THE AIRCRAFT WAS RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENSDR CALA9700351Combustion Case · crackedTHE NR2 ENGINE FAILED GIVING OFF A LOUD BANG AFTER TAKEOFF. FIRE WAS REPORTED IN THE ENGINE. BOTH FIRE BOTTLES WERE DISCHARGED AND THE AIRCRAFT WAS RETURNED TO IAH WHERE IT WAS MET BY THE FIRE DEPARTMENT. THE FIRE DEPARTMENT EXTINGUISHED THE FIRE. NO EMERGSDR AU970244Compressor · stalled(AUS) NO2 ENGINE COMPRESSOR STALL.SDR 97UAL900176Switch · out of adjustDURING IN-FLIGHT FLAP RETRACTION, AMBER LEADING EDGE FLAP LIGHT CAME ON FORWARD INSTRUMENT PANEL . SECOND OFFICER'S PANEL INDICATES NR 5 LEADING EDGE FLAP NOT RETRACTED. REPLACED AND ADJUSTED NR 5 LEADING EDGE FLAP POSITION INDICATING SWITCH. CHECKS O.K.SDR AU970453Fuselage · corroded(AUS) FUSELAGE CONTAINED LEVEL 2 CORROSION. FOUND DURING INSPECTIONSDR 97UAL900175O-Ring · cutNR THREE ENGINE LOST ENGINE OIL, LOW OIL PRESSURE LIGHT AND QUANTITY DOWN TO ZERO. SHUT DOWN ENGINE ON APPROACH. OIL PRESSURE READING 15 POUNDS PER SQUARE INCH PRIOR TO ENGINE SHUT DOWN. MAIN OIL SCREEN 'O' RING CUT AND LEAKING. REPLACED 'O' RING AND ENGSDR CA970428009Main Gear Box · failed(CAN) ENGINE WOULD NOT START. DISASSEMBLY OF MAIN GEARBOX FOUND THE PROBLEM TO BE THE DISPLACEMENT OF THE BEVEL DRIVE AND THE SPUR GEAR SHAFT REAR BEARING LINER. THE THREE PINS SECURING THIS LINER SHEARED ALLOWING THE LINER AND THE GEAR SHAFT TO MOVE FORWARD. SDR 97FDEA00123Turbine · failedON CLIMBOUT, THE NR 2 GENERATOR FELL OFF LINE. DURING THE DEPARTURE THE NR 2 ENGINE EGT WAS HIGH (NOT OVERTEMPED). WHEN PULLING THE THROTTLE BACK TO 80 PERCENT, N1 TO KEEP EGT AT 600 THE FUEL FLOW BECAME ERRATIC. NR 2 ENGINE THEN SHUTDOWN AS A PRECAUTION. SDR TWAA9728002Engine · oil lossTLH - FLT 507 - DURING CLIMB NR 1 ENGINE, S/N 1601, WAS SHUT DOWN DUE TO OIL QUANTITY LOSS. CHANGED ENGINE. (M)SDR 97UAL900145Circuit Card · failedON SHORT FINAL INTO ORD, THE LEFT GEAR RED LIGHT CAME ON WITH LEFT GEAR GREEN STILL ON. CYCLED GEAR AFTER A GO-AROUND AND OPERATED NORMALLY. REPLACED PRINTED CIRCUIT CARD A-9 IN LANDING GEAR ACCESSORY MODULE. CHECKS O.K.SDR AU970697Adc · faulty(AUS) NO1 AIR DATA COMPUTER FAILED. WORKSHOP INSPECTION FOUND THAT THE PITOT AND STATIC TRANSDUCERS FAILED THE CALIBRATION TEST BUT WERE NOT CONSIDERED TO BE THE CAUSE OF THE FAILURE. FURTHER INVESTIGATION FOUND A DRY SOLDER JOINT ON ONE OF THE DC POWER SUPPLYSDR MZZA97031Fuel Contl Unit · failedGUM - FLT 915 - DURING CLIMB-OUT, NR 2 ENGINE WAS SHOWING ERRATIC INDICATION WHILE PASSING THROUGH 1000 FEET, EPR PLUS/MINUS .05, N1 PLUS 10 PERCENT, EGT PLUS/MINUS 50 DEGREES CELSIUS, N2 PLUS/MINUS 10 PERCENT, FUEL FLOW PLUS/MINUS 500 LBS. CREW AIR RETURN TOSDR 97ZZZX1123Fuel Filter · dirtyDURING CLIMB-OUT FROM MIAMI, NR 1 ENGINE INDICATIONS FLUCTUATED, CREW REDUCED POWER TO IDLE AND RETURNED TO MIAMI FOR AN UNSCHEDULED LANDING. MAINTENANCE DRAINED FCU MOISTURE TRAP, CLEANED FCU FUEL FILTER AND P AND D VALVE FILTER. ACCOMPLISHED TEST FLIGHT WISDR TWAA9724001Scavenge Tube · failedSTL - DURING TAKEOFF, NR 2 ENGINE INDICATED LOW OIL PRESSURE. REMOVED AND REPLACED NR 6 BEARING OIL SCAVENGE TUBE, MFG P/N RD-2189-1. OPERATIONAL CHECK AND ENGINE RUN NORMAL. (M)SDR 97UAL900129Light · failedON MAIN GEAR EXTENSION THERE WAS NO GREEN INDICATION ON THE LEFT MAIN. THE LIGHT WOULD NOT TEST. NORMAL GEAR EXTENSION ON SECOND ATTEMPT. REPLACED LEFT GEAR LIGHT ASSEMBLY DUE TO FAILED. CHECKED O.K. ON GEAR SWING.SDR 97UAL900130Turbine Blade · fracturedNR TWO ENGINE FAILED APPROXIMATELY SEVEN MINUTES AFTER TAKEOFF. RETURNED TO FIELD. T-2 BLADE FAILED DUE TO CYCLE FATIGUE. AIRFOIL FRACTURED JUST ABOVE PLATFORM AND BLADE ENTERED THE AIRSTREAM RESULTING IN DOWNSTREAM DAMAGE IN THE TURBINE AND EXHAUST CASE.SDR DL72W970276Hydraulic Pump · inoperativeNR 1 ENGINE HYDRAULIC PUMP CHANGED FOR A SYSTEM PRESSURE LOSS.SDR 97UAL900123Regulator · failedAFTER TAKEOFF, CABIN FILLED WITH SMOKE. RIGHT PACK COMPRESSOR TEMPERATURE WENT INTO YELLOW BAND. MAIN SUPPLY TEMPERATURE EXCEEDED 160 DEGREES. REPLACED BLEED AIR REGULATOR.SDR IXKA9700004Prbc Fitting · brokenFLT 271 - AFTER TAKEOFF AT EWR, NR 3 EPR, N1 AND N2 DECREASED SIGNIFICANTLY EGT ADVANCED TO YELLOW AND FUEL FLOW INCREASED SIGNIFICANTLY RETURNED TO EWR. FOUND FITTING BROKEN ON PRBC UNIT. REMOVED AND REPLACED FITTING PER MM 75-31-11. RAN ENGINE LEAK CHECK SDR 97UAL900100Valve · stuckJUST AFTER ROTATION, THE RIGHT PACK OVERHEAT LIGHT CAME ON AND NR THREE BLEED TRIPPED. CABIN FILLED WITH SMOKE. RETURNED TO FIELD. OPERATED RIGHT PACK ON TAXI IN AND SMOKE CLEARED. FOUND 13TH STAGE MOD VALVE STUCK OPEN. REPLACED VALVE AND REGULAR. CHECKSSDR CALA9700110Compressor · failedTHE NR 2 ENGINE INDICATIONS WENT TO ZERO DURING CLIMBOUT. THE ENGINE WAS SHUTDOWN AND CLE TOWER REPORTED THAT ENGINE WAS SMOKING. BOTH FIRE BOTTLES WERE DISCHARGED AND THE AIRCRAFT WAS RETURNED TO CLE WHERE IT LANDED SAFELY. MAINTENANCE IS IN PROCESS OF REMSDR TWAA9715002Engine · failedBNA - DURING CRUISE, SHUT DOWN NR 2 ENGINE, S/N 1504, DUE TO VIBRATION. FOUND METAL PARTICLES IN TAILPIPE. REPLACED ENGINE. ENGINE OPERATION THEN CHECKED NORMAL. (M)SDR TWAA9715003Fuel Pump · failedOMS - DURING CLIMB SHUT DOWN NR 2 ENGINE, S/N 4019, DUE TO ENGINE SPOOL DOWN. FOUND ENGINE DRIVEN FUEL PUMP MALFUNCTION, MFG P/N 378201-7. REPLACED ENGINE DRIVEN FUEL PUMP. ENGINE OPERATION THEN CHECKED NORMAL. (M)SDR CALA9700109Engine · failedTHE NR 2 ENGINE EGT APPROACHED HIGH END LIMITS WHILE EN ROUTE TO EWR. THE NR 2 ENGINE WAS SHUT DOWN AS A PRECAUTIONARY MEASURE. THE AIRCRAFT LANDED AT EWR WITHOUT INCIDENT. THE NR 2 ENGINE WAS REMOVED AND REPLACED. THE SDR WILL REMAIN OPEN FOR PART INFORMATSDR 97UAL900064Gasper Fan · failedSTRONG ELECTRICAL BURNING SMELL AND PUNGENT ODOR AROUND ROWS 9 THROUGH 11, NO FIRE OR SMOKE OBSERVED. SMELL SEEMED TO DISSIPATE AFTER LIGHTING TURNED OFF. *S/D* INSPECTED LIGHTING IN CABIN, FOUND NO SIGN OF BAD LIGHTS OR BAD BALLAST. REPLACED GASPER FAN, CSDR 97UAL900063Control Mech · out of adjustRECEIVED FLAP WARNING, EXECUTED GO-AROUND. OUTBOARD FLAP INDICATOR SHOWS ABOUT 28 DEGREES INSTEAD OF 30 DEGREES. *S/D* FOUND FLAPS OUT OF RIG. RERIGGED FLAPS, SYSTEM CHECKS OK.SDR TWAA9709003Engine · failedSTL - FLT 128 - DURING CRUISE, SHUT DOWN NR 2 ENGINE, DUE TO OIL FILTER BYPASS LIGHT ILLUMINATION. FOUND METAL PARTICLES IN OIL FILTER. REPLACED NR 2 ENGINE. ENGINE OPERATION THEN CHECKED NORMAL. (M)
Back to Pratt & Whitney JT8D-15