SDR CALA2013121693724Control Valve · stuckRT PACK EICAS MSG & STATUS MSG ILLUMINATED, PACK OFF LIGHT ALSO. RT PACK UPPER FCV IS STUCK CLOSED. LOWER FCV IS CYCLING. REPLACED UPPER FCV & CLEANED LOWER FCV AIR FILTER. ACCOMPLISHED PACK OPERATIONAL CHECK.SDR CALA2013121693699Control Valve · malfunctionedTHE UPPER RT PACK FLOW CONTROL VLVS IS NOT IN THE COMMANDED POSITION. RESET PACK FLOW CONTROL VLV ONCE, BUT MSG RETURNED. DEFER FLOW CONTROL VLV UPPER RT IAW MEL 2151C. REMAINING FLOW CONTROL VLVS ON RT OPERATES NORMAL. REPLACED UPPER RT PACK FLOW CONTROL SDR DALA13068950910A/C Pack · failedCREW NOTED THAT DURING LEVEL OFF AT FL240, THE FLOW LIGHT ILLUMINATE AND THE CABIN LOST PRESSURIZATION. INITIATED A RAPID DESCENT, PAX OXYGEN MASKS DEPLOYED AUTOMATICALLY, AND LANDED SAFELY. LT PACK FAILED. MAINTENANCE FOUND LT PACK ICE SCREEN AND WATER SSDR ASAA2013121196836Warning Light · false activationAFTER ENGINE START, LEFT PACK ANNUNCIATOR ILLUMINATED. ANNUNCIATOR EXTINGUISHED WHEN MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED PACK-ZONE TEMPERATURE CONTROLLER BITE PROCEDURE FOR NR 1 CONTROLLER, IAW FIM 21-62, TASK 801. TEST PASSED. NO FAULTS NOTED.SDR UIEA2013121100594Controller · malfunctionedAFTER ENG START EICAS MESSAGE L PACK TEMP RECEIVED, RAN CHECKLIST AS REQUIRED. PERFORMED BITE ON LT PACK CONTROLLER, FAULTED RAM EXHAUST ACTUATOR, RESET LT PACK CONTROLLER & PERFORMED TEST ON LT PACK EXHAUST ACTUATOR IAW AMM 21-53-02, OPERATION IS NORMAL. AFSDR CA131216022Acm · failed(CAN) DURING ACFT PUSHBACK, PILOTS REPORTED SMOKE IN THE CABIN ACCOMPANIED BY RT PACK TEMP CAUTION MESSAGE POSTED ON THE EICAS, RT PACK COMPRESSOR DISCHARGE OVERHEAT. ACFT RETURNED TO GATE. NO TIME FOR T/S, HIL/DDG ITEMS WERE OPENED FOR THE RT PACK AND THE ASDR ASAA2013121096716Actuator · malfunctionedBLUE RAM AIR FULL OPEN LIGHT ILLUMINATED CONTINOUSLY DURING CRUISE. ACFT GROUNDED. REPLACED RT RAM AIR INLET ACTUATOR IAW AMM 21-51-21, OPS CHECKED GOOD.SDR ASAA2013121096713Control Valve · failed15,000 FEET, DURING PACK HIGH FLOW INHIBIT TEST ON LT PACK WITH LT PACK OFF, FLAPS 1 SELECTED CABIN RATE F/O CLIMB DID NOT RATE UP. ACFT GROUNDED. R & R LT FLOW CONTROL VALVE IAW MM 21-51-01, PERFORMED OPS CHECK/LEAK TEST, CHECKED GOOD.SDR F3LA2013121100940Duct Clamp · separatedAIRCRAFT WAS OPERATING FLIGHT 245 IAH-DEN, DEC 7, 2013. PACK 2 WAS ALREADY INOPERATIVE ON MEL, MDDR 1101834. PACK 1 FAILED IN FLIGHT, CABIN ALTITUDE CLIMBED TO THE POINT 02 MASKS DEPLOYED, AIRCRAFT DIVERTED TO DFW. AIRCRAFT WAS FERRIED TO GYR WITH BOTH PACKSDR ASAA2013120896687A/C Pack · failedFWD CABIN ZONE TEMP LIGHT ON MASTER RECALL DURING FINAL APPROACH. ACFT GROUNDED. PERFORMED BITE CK, FOUND TEMP ZONE CONT FAULT STANDBY PACK LOGGED REF FIM 21-62, TASK 802. REPLACED NR 1 PACK TEMP ZONE CONT. OPS CHECKED NORMAL. BITE CHECKED, NO FAULT IAW MSDR REXA2013120702219Control Valve · malfunctionedDURING PUSHBACK WE RECEIVED A LT PACK AUTO FAIL CAUTION ASSOCIATED WITH AN ODOR. WE SHUT OFF LT PACK & ODOR WENT AWAY & CAUTION WENT AWAY IN ABOUT 5 MINUTES. IAW MEL 21-51-1 B. ENTERED IN MM2 MC ADVICES PLACARD INSTALLED. R & R TEMP CONTROL VLV IAW AMM 21-SDR ASAA2013120796659Control Valve · faultedDURING CLIMBOUT RT PACK LIGHT ILLUMINATED, RESET MASTER CAUTION PACK LIGHT WENT OUT. ACFT GROUNDED. PERFORMED BITE TEST OF PACK/ZONE TEMP CONTROLLERS RT PACK SHOWS FAULT OF TCV. R & R TCV, PERFORMED BITE TEST OF PACK/ZONE TEMP CONTROLLERS, NO FAULTS FOUNDSDR ASAA2013120696646Actuator · faultedLEFT PACK LIGHT ON MASTER CAUTION RECALL LIGHT EXTINGUISHED ON MASTER CAUTION RESET. COMPLIED WITH QRH. ACFT GROUNDED. PERFORMED LT PACK/ZONE TEMP CONTROL BITE TEST, FOUND RAM AIR INLET ACTUATOR FAULT. REPLACED LT RAM AIR INLET ACTUATOR REF AMM 21-51-21. OPSDR ASAA2013120696645Control Valve · faultedRIGHT A/C PACK LIGHT ON DURING MASTER CAUTION RECALL, PACK LIGHT GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED BITE TEST OF RT PACK, LOGGED THIS PACK TCV FAULT. R & R TEMP CONTROL VALVE (V141) REF MM 21-51-10. OPS CHECK GOOD.SDR ASAA2013120596636Control Valve · malfunctionedRT PACK LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. ACFT GROUNDED. GROUND VERIFICATION SUCCESSFUL. ACCOMPPLISHED PACK-ZONE TEMP CANT. BITE, NR 1 CONT NO FAULTS, CONT. NR 2 SHOWS THIS PACK TCV. CLEARED FAULT. RAN CABIN TEMPERATURE CONTINUE & IND. OPSSDR 29GA1217201335021Compressor · seizedLOUD BANG, FOLLOWED BY GRINDING SOUND, ACCOMPANIED BY BURNING RUBBER ODOR. REPLACED AIR CONDITION COMPRESSOR AND DRIVEBELT, PN 232L100. OPS CHECK GOOD.SDR ASAA2013120496601Control Valve · warning lightDURING FINAL APPROACH, LEFT PACK LIGHT ILLUMINATED. RESETS WITH MASTER CAUTION. ACFT GROUNDED. ACCOMPLISHED INTERROGATION OF BOTH LT & RT ZONE TEMP CONTROLLERS. LT ZONE TEMP CONTROLLER FAULTED TEMP CONTROL VALVE REF AMM 21-61-00. REMOVED TEMP CONTROL VALVSDR CA140120004Acm · seized(CAN) CABIN AND COCKPIT FILLED WITH SMOKE AFTER APU STARTED, NR 1 PACK AUTOFAIL DISPLAYED. FOUND LT AUTO PACK FAIL SMOKE IN CABIN DUE TO SEIZED LT ACM.SDR REXA2013120302209Acm · seizedCABIN & COCKPIT FILLED WITH SMOKE AFTER APU STARTED NR 1 PACK AUTO FAIL DISPLAYED. DEFER COCKPIT TEMP CONTROL SYS IAW MEL 21-61-14. CAT C, MC ADVISED 96041. ENTERED INTO MMO2, PLACARD INSTALLED. INVESTIGATED CTRL 2481268-1 NR 1 LT AUTO PACK FAIL, SMOKE IN CSDR ASAA2013120396593Control Valve · faultedLEFT PACK LIGHT & AIR CONDITION ILLUMINATED ON RECALL. FOLLOWED QRH. LIGHT EXTINGUISHES ON RESET. ACFT GROUNDED. IAW FIM TASK 21-53, TASK 803 PACK LIGHT DID NOT COME ON WHEN RUNNING PACK. INTERMITTENT FAULT. CHECKED LT PACK ZONE TEMP CONTROLLER, FOUND TSDR ASAA2013112996559A/C Pack · malfunctionedFROM ROW 8 TO OVERWING EXIT, TEMP TOO HOT, REGARDLESS OF FORWARD OR AFT KNOB POSITION, PAX & F/A REPORT. ACFT GROUNDED. BITE CHECKED BOTH TEMP CONTROLERS AMM 21-6100 NO FAULTS LOGGED. OPERATED PACKS, HOT THEN COLD. OBSERVED TEMP DECREASE FROM ROW 8 TO OVERSDR ASAA2013112896573Warning Message · false activationON GROUND BOTH MASTER CAUTION AND AIR CONDITION ANNUNCIATOR BLINK ON AND OFF CONTINUOUSLY. ACFT GROUNDED. PERFORMED PACK TEMP CONTROLLER BITE TEST, BOTH NR 1 AND NR 2 TEMP CONTROLLER, NO DEFECTS NOTED. MASTER CAUTION AND A/C LIGHTS EXTINGUISHED. SYS OPS CHSDR ASAA2013112896570Actuator · faultedON MASTER CAUTION RECALL RT PACK LIGHT ILLUMINATED WILL RESET. ACFT GROUNDED. LOGGED RAM AIR ACTUATOR FAULT. R & R RT RAM AIR ACTUATOR REF MM 21-51-21, GROUND FUNCTION, OPS CHECK GOOD.SDR ASAA2013112896569Controller · malfunctionedDURING FINAL APPROACH, PUSHED RECALL AND RECEIVED A RT PACK LIGHT. RAN CHECKLIST, LIGHT STAYED ILLUMINATED. ACFT GROUNDED. PERFORMED BIT TEST OF BOTH PACK ZONE TEMP CONTROLLERS, NR 2 CONTROLLER SHOWED RAM AIR ACTUATOR FAULT ON BIT TEST. PREVIOUS FLT WAS GOSDR ASAA2013112796552A/C Pack · malfunctionedFUNCTIONAL CHECK FOR PACK, HIGH FLOW INHIBIT FAILED WITH LT PACK OFF, CONFIGURATION WAS ALT 15,000 FT, PRESSURIZATION MODE SELECTOR MANUAL OUTFLOW VALVE ADJUSTED FOR ZERO CABIN RATE OF CLIMB RT PACK AUTO, LT PACK OFF, FLAPS UP. WHEN FLAPS SELECTED 1, CABIN DISDR HNAA2013112700593Acm · failedACM FAILED AND NOISES ARE HEARD WHEN APU OR ENGINE BLEED IS SELECTED ON.SDR AALA20131126008Control Valve · malfunctionedDEN INFLIGHT ORD PDX CREW REPORTED RT HAND PACK FAILED. EMERGENCY DECLARED FLIGHT DIVERTED DEN LANDED WITHOUT INCIDENT. PLACARDED RT HAND PACK INOPERATIVE IAW MEL. FLIGHT CONTINUED TO DESTINATION. REPLACED TEMPERATURE CONTROL VLV AT ORD ON 11/26/2013. SYSTSDR CALA2013120593474Control Valve · faultyRT PACK TEMP EICAS AT FL 340. SELECTED STBY IAW QRH, LIGHT IS OFF. RT TEMP CONTROL VLV NOT MOVING IN AUTO. REPLACED RT TEMP CONTROL VLV IAW, OPERATION CHECKED GOOD.SDR ASAA2013112696543Module · failedMASTER CAUTION ILLUMINATES WHEN APU BLEED SWITCH IN ON POSITION. AIRCRAFT GROUNDED. R & R AIR CONDITION MODULE, AMM REF 21-51-65. OPS CHECK NORMAL, GROUND VERIFICATION SUCCESSFUL.SDR REXA2013112602278Ecs · contaminatedTAKE OFF ROLL, THICK WHITE SMOKE OBSERVED IN COCKPIT & CABIN AS REPORTED BY FLIGHT ATTENDANT, NO OTHER. ABNORMAL INDICATIONS, SMOKE SMELLED LIKE BURNING, DE-ICING FLUID. EXAMINATION OF DISC, RESIDUAL SMELL ON CABIN & GVI OF ECS SYS INDICATES THAT SUSPECTED DESDR CALA2013112693287Control Valve · faultyRT PACK STATUS MESSAGE, UPPER FLOW CONTROL VLV DOES NOT OPEN, LOCKED CLOSED. LOCKED VLV CLOSED IAW MEL 2151C. REPLACED UPPER FLOW CONTROL VLV IAW MM.SDR AALA20131126022Control Valve · failedPHL CREW REPORTED UNABLE TO PRESSURIZE AIRCRAFT. EMERGENCY DECLARED FLIGHT RETURNED PHL LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RT HAND PACK FLOW CONTROL VLV. SYSTEM GROUND CHECKED NORMAL OPERATION CLOSED.SDR CALA2013112693268A/C Pack · surgesAFTER ENG START & PACKS TURNED ON THE NR 2 PACK SURGES.SDR CALA2013112693262Control Valve · faultyPACK INOPERATIVE, UPPER FLOW CONTROL VLV DEFER CLOSED & LOWER VLV WILL NOT OPEN, UNABLE TO RESET. REPLACED LOWER FLOW CONTROL VLV IAW AMM.SDR ASMF201312004Control Valve · failedAIRCRAFT RETURNED TO PLATFORM, DURING TAXING THE RT PACK TEMP REACHED MORE THAN 60 CELSIUS DEGREES & BOTH PACKS REACHED LESS THAN 18 CELSIUS DEGREES IN PAX CABIN. THE TEMP CONTROL VLV FAILED SO THE REPORT WAS DEFERRED IAW MEL 21-33 CAT C AT GDL, THE TEMP CONTSDR ASAA2013112296497Warning Light · false activationON RECALL, LEFT PACK LIGHT ILLUMINATES. ACCOMPLISHED QRH PROCEDURE, BOTH PACK LIGHTS EXTINGUISHED. ACFT GROUNDED. PERFORMED NR 1 PACK / ZONE TEMP CONT BITE TEST IAW MM 21-61-00-700. BIT PASSED, PREV FLIGHT LOGGED TCV THIS PACK & VERIFY PASSED. PRESSED RESSDR ASAA2013112296493Warning Light · false activationDURING MASTER CAUTION RECALL, RT PACK LIGHT CAME ON. ACFT GROUNDED. GROUND TEST PASSED WITH NO FAULTS NOTED IAW AMM 21-51-00-700-803 AND NO MAINTENANCE HISTORY FOUND WITHIN THE PAST 30 DAYS.SDR ASAA2013112296491Controller · faultedON RECALL, LEFT PACK LIGHT ILLUMINATED, EXTINGUISHES WHEN RECALL PRESSED AGAIN. ACFT GROUNDED. ACCOMPLISHED PACK-ZONE TEMP CONTROLLER BITE IAW MM 21-61-00-700-806-002. PREVIOUS FAULT LOGGED FOR LT RAM INLET ACTUATOR. RESET FAULT, OPS CHECKED GOOD, FAULT DOESDR ASOA20131121131Acm · odorCREW REPORTED A DISTINCTIVE ELECTRICAL BURNING ODOR IN FLIGHT. CABIN EXPERIENCED SLIGHT HAZE. PASSENGER IN 11A STATED SMOKE SEEN COMING FROM ABOVE SEATS 8 AND 9CD. MAINTENANCE R & R NR 1 ACM WITH OPS CHECK SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR AALA20131120012Valve · leakingSFO LT PACK TRIM AIR CHECK VLV LEAKING. VLV INSTALLED WITH AXIS VERTICAL ALLOWING VLV SEGMENTS TO WEAR THROUGH VLV BODY. REPLACED LT HAND TRIM AIR CHECK VLV. SYSTEM GROUND CHECKED NORMAL OPERATION CLOSED.SDR R61A201311201243Bracket · crackedDURING HEAVY CHECK WAS REPORTED THAT LT RAM AIR DUCT SUPPORT BRACKET CRACKED. MX R & R SUPPORT BRACKET IAW SRM 51-40-02, 51-41-01.SDR ASAA2013112096477Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. LIGHT GOES OUT WHEN MSTC RESET. BACKUP CONTROLLER OPERATES NORMAL. ACFT GROUNDED. BOTH CONTROLLERS LOGGED FLIGHT DECK TRIM VALVE. FAULT RESET REF TASK 21-61-00-700-808-001. R & R CONTROL CABIN TRIM VALVESDR ASOA2013112509480Acm · smokeAFTER TAKEOFF, SMOKE TOILET CAUTION MESSAGE, COMPLIED WITH QRH. NO VISIBLE FUMES IN FLIGHT DECK. PASSENGERS REPORTED "HAZE" AND COLOR IN CABIN. ACFT RETURNED. R & R RT ACM IAW AMM 21-51-10. OPS CHECKED GOOD IAW AMM 21-51-00. RETURNED TO SERVICE.SDR ASAA2013111796446Actuator · warning lightLEFT PACK ILLUMINATED ON RECALL, EXTINGUISHED WITH MASTER RECALL RESET. ACFT GROUNDED. REPLACED LT RAM AIR ACTUATOR IAW AMM 21-51-21/401.SDR DXTA2013120405589Compressor · faultyELECTRICAL ODOR NOTED ON DESCENT. SUSPECTED COCKPIT PAC BECAUSE IT WAS DIFFICULT TO SET TEMP & HOLD IN AUTO OR MANUAL. SELECTED COCKPIT PAC TO OFF & ODOR DISSIPATED. REMOVED BAD COCKPIT TURBO COMPRESSOR PN 738284-33, SN & INSTALLED CRS SI3R842L. REPAIRED TSDR ASAA2013111696432Door · unknownLEFT RAM AIR DOOR OPENED FOR APPROXIMATELY 5 MINUTES DURING DESCENT 350KTS CLOSED AT 13000. ACFT GROUNDED.SDR ASAA2013111696430Control Valve · malfunctionedAFTER ENGINE START DURING AFTER START CHECKLIST LT PACK LIGHT ILLUMINATED ON RECAL AND WENT OUT WHEN MASTER CAUTION DEPRESSED. ACFT GROUNDED. REPLACED TEMP CONTROL VALVE AND OPS CHECKED GOOD IAW AMM 21-51-10-000-801 AND -860-004.SDR ASAA2013111596423Warning Light · false activationBOTH MASTER CAUTION LIGHT COME ON WITH THE AIR CONDITIONER LIGHT ILLUMINATED ON THE RECALL PANEL WITH NO LIGHT COMING ON THE OVERHEAD PANEL. ACFT GROUNDED. NO FAULTS FOUND PERFORMED BITE AMM REF 21-61-00, NO HISTORY 30 DAYS.SDR 2013FA0000638Gearshaft · damagedDURING ROUTINE INSPECTION, FOUND AIR CONDITIONING DRIVE LEAKING OIL, REMOVED ACFT DRIVE AND FOUND GEAR SHAFT SPLINES, PN 3100450-01 AND DRIVEN GEAR SHAFT SPLINES, PN 2601267-1 COMPLETELY WORN BEYOND LIMITS, SPLINES ON BOTH DRIVE AND DRIVEN GEAR SHAFTS ALMOST GSDR 2013FA0000637Drive Shaft · damagedDURING ROUTINE INSPECTION, FOUND AIR CONDITIONING DRIVE LEAKING OIL, REMOVED ACFT DRIVE AND FOUND GEAR SHAFT SPLINES, AND DRIVEN GEAR SHAFT SPLINES, COMPLETELY WORN BEYOND LIMITS, SPLINES ON BOTH DRIVE AND DRIVEN GEAR SHAFTS ALMOST GONE.
Back to JASC 2150