Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA013060Door Frame · crackedDURING SCHEDULED 1/2D CHECK, FOUND FWD ENTRY DOOR FRAME CRACKED AT # 5 STOP PIN. REPAIRED DOOR FRAME PER SRM.SDR SWAA013012Frame · crackedDURING SCHEDULED 1/4D CHECK, FOUND FWD SVC DOOR AFT FRAME CRACKED AT CUTOUT 3RD STOP FROM BOTTOM. REPAIRED FRAME PER SWA T1-152-003.SDR ZW0A0110601Angle · crackedDURING CHECK-C MAINT THE FWD RT SERVICE DOOR LOWER HINGE ARM SUPPORT BEAM WAS CRACKED IN ANGLE RADIUS. REPLACED ANGLE PER SPM 6-70-01. INSTALLED FASTENERS PER SRM 51-30-05 AND 51-30-02.SDR 2001UALA02179Door Frame · crackedNR 2 RIGHT HAND MED UPPER DOOR FRAME AT GATE HAS CRACK ATTACH HOLE. DOOR SHOP ACCOMPLISHED REPAIR.SDR SWAA012955Frame · crackedDURING SCHEDULED 1/4D CHECK, FOUND FWD SERVICE DOOR AFT LOWER FRAME CRACKED. REPAIRED FRAME PER BAC DRAWING.SDR AWXA200100579Skin · crackedMCN - C13 CK - "C" - CRACK FOUND ON R2 DOOR (.25") AT LOWER HINGE CUTOUT, UPPER EDGE, BS 958. MAINTENANCE TRIMMED OUT THE CRACK, FABRICATED REPAIR DOUBLER AND INSTALLED IAW B737 SRM 52-00-3, FIG 5, PG 8, 8A,B,C & 9.SDR 2001F00644Door · missingAFTER LANDING THE RIGHT AIR START DOOR WAS FOUND MISSING. INSPECTED AIRCRAFT FOR AND REPAIRED COLLATERAL DAMAGE. REPLACED DOOR ASSEMBLY. (M)SDR C2XA01CL217Lock · out of adjSDF FLIGHT 4072 THE CREW REPORTED THE SERVICE DOOR WAS JAMMED, WOULD NOT OPEN OR CLOSE. MAINTENANCE INSPECTED AND ADJUSTED THE SERVICE DOOR LOCKING MECHANISM. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR SWIA200110241Access Panel · openLOUD SQUEAL COMING FROM RIGHT SIDE OF NOSE ON TAKEOFF. DIVERTED TO SLC.INSPECTED FORWARD PORTION OF A/C. FOUND FORWARD RIGHT SIDE NOSE DOOR ACCESS PANEL OPEN. NO DAMAGE. CHECKS GOOD.SDR USAA011311Door Frame · crackedPIT - FOUND FRAME/JAMB SPACER CRACKED 2 INCHES, JOINING SPACER OF FORWARD SERVICE DOOR. MANUFACTURED NEW SPACER OUT OF 2024-T3 .080 PER OM-26 NR J3-46-52500-C-002. (M)SDR MWEA011255Web · corrodedFORWARD SERVICE DOOR, LIGHT CORROSION AND MISDRILLED HOLE ON LOWER WEB OF DOORS. FABRICATED AND INSTALLED REPAIR DOUBLER.SDR CA010912014Handle · broken(CAN) THE RAMP PERSONNEL BROKE THE OUTER HANDLE OF THE SERVICE DOOR DURING NORMAL OPERATION. THE PERSON WORKING REPORTED THAT HE DID NOT USED ANY EXCESSIVE FORCE TO OPEN THE DOOR. THE MAINTENANCE REPLACED THE OUTER HANDLE ON THE SERVICE DOOR.SDR SIMA200124906Door · departedRSW - FLT 5369 - DURING CRUISE, AIR CONDITIONING GROUND INTERCONNECT ACCESS DOOR DEPARTED AIRCRAFT. INSTALLED REPLACEMENT ACCESS DOOR. (M)SDR AUS20010967Cable · frayed(AUS) AFT SERVICE DOOR RELEASE CABLES FRAYED. FOUND DURING INSPECTION IAW AD/B737/042.SDR AUS20010966Cable · frayed(AUS) FORWARD SERVICE DOOR RELEASE CABLES FRAYED. FOUND DURINGINSPECTION IAW AD/B737/042.SDR DLM11011415Door · missingFOUND BY MTC EXTERNAL ELECTRICAL CONNECTION DOOR MISSING - REPLACED SAMESDR ERKR200100145Hinge · gougedAFT GALLEY/SERVICE DOOR HINGE ARM GOUGED 2 PLACES AS MARKED. BLENDED GOUGES ON AFT GALLEY SERVICE DOOR HINGE PER MD-90 SRM 52-00-01 PG 3.SDR 2001UALA01741Door · dentedRIGHT SIDE AFT OF FWD LAV SERVICE DOOR HAS A DENT. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE, INSTALLED DOUBLER.SDR USAA011084Gate · corrodedPIT - FOUND GATE CORRODED .125 INCH BY 4 INCH, BOTTOM GATE OF AFT SERVICE DOOR. (M)SDR SWAA012237Retainer · out of positionAIR TURNBACK, AFTER TAKEOFF A/C CABIN WOULD NOT PRESSURIZE. F/A REPORTED NOISE FROM AFT SVC DOOR. REPOSITIONED AFT SVC DOOR PRESS SEAL RETAINER PER MM.SDR CALA0100746Intercostal · crackedINSPECTION FOUND A 7" CRACK IN R-1 DOOR INNER INTERCOSTA UNDER HINGE ATTACH POINT. THE R-1 DOOR WAS REMOVED IAW MM 52-41-00. THE CRACK WAS STOP DRILLED AND A REPAIR CAP AND FITTING WERE INSTALLED IAW SRM 52-05, FIGURE 5. REINSTALLED R-1 DOOR IAW MM 52-41-00.SDR CALA0100745Pan · gougedINSPECTION FOUND R-1 DOOR LOWER PAN GOUGED AT RIVNUTS. THE PAN SUPPORT WAS REMOVED FOR ACCESS IAW SRM 51-30-02. A REPAIR ANGLE AND DOUBLER WAS INSTALLED IAW ECRA 5240-01386. THE SUPPORT PAN WAS REINSTALLED IAW SRM 51-30-2.SDR USAA010966Skin · crackedCLT - FOUND SKIN INTERIOR WITH CRACK .5 INCH, L4 DOOR, AT LIGHTENING HOLE ABOVE LOWER HINGE. INSTALLED DOUBLER PER EA 85161. (M)SDR USAA010884Skin · crackedTPA - FOUND DOOR EXT SKIN CRACKED .25 INCH, FORWARD SERVICE DOOR, UPPER HINGE CUTOUT. REPAIR DOUBLER INSTALLED PER SRM 52-10-01 PAGE 201 AND SB 737-52-1096. (M)SDR CA010815003Door · missing(CAN) 1. DURING THE TURNAROUND IT WAS OBSERVED THAT THE MID LAV SERVICING PANEL DOOR WAS MISSING. 2. DMI 35881 WAS RAISED UNDER CDL 52-4. AIRCRAFRT RELEASED FOR FLIGHT.3. NO FURTHER INCIDENT DURING SUBSEQUENT FLIGHT.SDR SWIA200110016Door · openON DEPARTURE AT SPEED ABOVE 280 KNOTS, LOUD HIGH PITCH SOUND FROM FRONT OF AIRCRAFT. RETURNED TO SLC. FOUND SMALL DOOR, FOR NOSE DOOR SWITCH, OPEN. NO DAMAGE NOTED ON DOOR. CLOSED AND LATCHED DOOR.SDR 2001UALA01323Door Frame · crackedFWD GALLEY DOOR AFT SIDE CRACKED AT THIRD STOP FITTING CUTOUT. REMOVED DAMAGE. INSTALLED DOUBLER. MAJOR REPAIR ACCOMPLISHED.SDR QXEA0101063Structure · crackedPDX - DURING INSPECTION, FOUND SERVICE DOOR CRACKED. REPAIRED VIA THE INSTALLATION OF DOUBLER AND FILLER IN ACCORDENCE WITH STRUCTURAL REPAIR MANUAL 51-31-01. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR DL72W011024Door · not closedON CLIMBOUT AFT FLT ATTENDANT CALLED UP TO REPORT LOUD HISSING NOISE AT LEFT AFT SERVICE DOOR. RTN TO ATL. FOUND DOOR IMPROPERLY CLOSED. CYCLED DOOR, CLOSES NORMALLY.SDR RRXA11351Skin · corrodedDURING A MAINTENANCE VISIT FOUND SKIN ON RT FWD SERVICE DOOR, CORROSION OUT OF LIMITS. CUT OUT DAMAGE AREA IAW SRM 52-2-0 FIG 4, FABRICATED& INSTALLED REPLACEMENT PART IAW SRM 52-2-0 FIG 4 & 52-3-1 FIG 3 AND 51-1-21,SDR DL733010932Skin · crackedDOOR SKIN CRACKED N/R 123 C-1 CK OPN 8727 IN DFW. ITEM:R-1 DOOR SKIN CRACKED AT LOWER HINGE CUTOUT AT AFT UPPER AND LOWER CORNERS. STOP DRILLED AND REMOVED CRACK AT UPPER AND LWR CORNERS PER SRM 52-00-01. PERFORMED HFEC PER NDT PART 6 CH 51-00-00, FIG 4. MSDR DL733010933Skin · crackedDOOR SKIN CRACKED N/R 122 C-1 CK OPN 8727 IN DFW. ITEM: R-1 DOOR SKIN CRACKED AT UPPER HINGE CUTOUT AT LOWER AFT CORNER.SDR AWXA0001825Door · out of rigPHX - air turnback - 5/31/01 - FLT 49 - on climbout at 10000 ft the left aft entry door light illuminated. the door handle was observed not fully closed and had a small air leak (L4 door); the aircraft returned to PHX making an uneventful landing. in PHX theSDR AWXA0001813Web · gougedFRAME 66 AT UPPER FWD CORNER OF L2 DOOR, WEB AND RIVETS DAMAGED. REPAIRED IAW AWA ER 26-5345-01150-DD1; FINISH RESTORED IAW AMM 55-70-00 PG 1.SDR DL72S010877Door Frame · crackedR1 DOOR AFT FRAME IS CRACKED AT LWR STOP FITTING. REPAIRED PER M/M 52-12-000-8.SDR SIMA200114804Door · openORD - FLT 4215 - CREW REPORTED AN AUDIBLE VIBRATION COMING FROM THE LEFT SIDE OF AIRCRAFT NOSE. MAINTENANCE FOUND THE GPU ACCESS DOOR TO BE OPEN. DOOR WAS DAMAGED AND WAS PUT ON CDL AT THIS TIME. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR ABXA010243Seal Bracket · crackedRIGHT (TYPE I) FORWARD DOOR, FORWARD LOWER CORNER SEAL DEPRESSION CRACKED. REPAIRED IAW DC8 SRM 52-2-2.SDR SWAA011534Skin · crackedFWD SVC DOOR SKIN CRACKED AT UPPER LEFT CORNER. REMOVED AND REPLACED FWD SVC DOOR PER MM.SDR AALA20011063Handle · corrodedTUL - FOUND DOOR HANDLE MECH, FORWARD GALLEY SERVICE DOOR, SLEEVES HAS CORROSION BETWEEN SLEEVES. REMOVED AND REPLACED DOOR HANDLE MECHANISM WITH SERVICEABLE PER ESO 80177. (M)SDR CALA0100457Bottle · dischargedDOOR R-4 WAS HARD TO OPERATE. THE R-4 DOOR N2 BOTTLE WAS RESERVICED IAW MM 52-12-16.SDR UPS01235967Door Frame · crackedINSPECTION TYPE:C, CRACK ON AFT UPPER SECTION OF GALLEY DOOR FRAME. REPAIR CARRIED OUT IAW UPS EO B727-5240-4626.SDR GLBA2001097Door · openRIGHT OIL SERVICE DOOR OPENED DURING CLIMBOUT. RESECURED DOOR, OPS CHECKED GOOD.SDR AWXA0001725Fitting · crackedR1 DOOR LWR AFT CORNER FITTING CRACKED. REMOVED FITTING, FABED AND INSTALLED REPLACEMENT IAW SRM 51-40-02 PG 2-4 AND BAC DWG 69-69854-1.SDR AWXA0001724Bracket · crackedUPON REMOVAL OF OUTER BRACKET R1 DOOR LWR AFT CORNER FOR ACCESS TO INNER FITTING, FOUND OUTER BRACKET ALSO CRACKED. REMOVED AND REPLACED OUTER BRACKET IAW SRM 51-40-02 PG 10-12.SDR AT0100168Door · corrodedFOUND LEFT AFT LAV SERVICE DOOR CORRODED BEYOND LIMITS. REPLACED DOOR PANEL IAW DC9 SRM 51-30-01.SDR SWAA011317Door Frame · crackedDURING SCHEDULED 1/2D CHECK, FOUND FWD SVC DOOR FWD FRAME CRACKED AT CUTOUT FOR NR 3 STOP. REPAIRED FRAME PER SWA TR.SDR CALA0100434Skin · crackedR1 DOOR SKIN LOWER HINGE CUTOUT CRACKED (1 INCH). REPAIRED R1 DOOR CUTOUT PER SRM 52-00-01 PG 203, 204. DOOR OPERATES NORMALLY.SDR SWIA972539Door · unlatchedSERVICE DOOR LIGHT CAME ON TAKEOFF ROLL. FOUND OUTBOARD FORWARD THUMB LATCH OPEN. SECURED LATCH. OPS CHECK GOOD.SDR MWEA010633Hinge · wornAFT PRESSURE BULKHEAD DOOR UPPER HINGE LOBES ARE WORN. REMOVED AND REPLACED UPPER HINGE LINK.SDR AWXA0001626Structure · corrodedAFT SERVICE DOOR INNER SILL CHORD CORRODED FROM APPROX BS 960-986.5. CORROSION REMOVED - MAT LOSS IN EXCESS IAW SRM 53-60-15 FIG 101 PG 104 LIMITS; INNER SILL CHORD REPLACED BY NEW CHORD; DRAIN TROUGH REINSTALLED; DRAIN TROUGH FITTINGS INSTALLED IAW EO 53-15-
Back to JASC 5240