JASC 5310
Service difficulty reports · 38,511
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2026080601503Door Frame · crackedCRACK ON DOOR POST WAS FOUND. DOOR POST WAS REPAIRED PER CRJ900 SRM 51-71-59-001-001-A01SDR SWAA2026050483760Web · crackedCRACK INDICATION FOUND ON HORIZONTAL PRESSURE DECK WEB AT LBL 31 BETWEEN STA 663 TO STA 675 AT MAIN WHEEL WELL COMPARTMENT. CRACK LENGTH: 0.312 IN. PERFORMED PERMANENT REPAIR ON HORIZONTAL PRESSURE DECK WEB BETWEEN STA 663 TO STA 675 AND BTW LBL 25 TO LBL 60 SDR SWAA2026043083478Pressure Deck · crackedCRACK INDICATION FOUND ON HORIZONTAL PRESSURE DECK WEB AT RBL 42 BTWN BS 663 - 675. PERFORMED PERMANENT REPAIR ON HORIZONTAL PRESSURE DECK WEB IAW SRM 53-40-51-2R-2, REPAIR 2.SDR SWAA2026043083756Crossbeam · crackedCRACKED FLOOR STRUCTURE BRAKE PANEL BS 540 AND LBL 1 IN PASSENGER CABIN. REPLACED BREAK PANEL LOCATED BS 540 AND LBL 1 IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 143A5240, SHEET:14, REV-.SDR SWAA2026043083753Crossbeam · crackedCRACK FLOOR STRUCTURE BRAKE PANEL BS 540 AND RBL 1 AT PASSENGER CABIN. REPLACED BREAK PANEL LOCATED BS 540, RBL 1 IAW SRM 51-40-02; SRM 51-10-02, ITEM 9, AND DWG 143A5240, SHEET:14; REV-.SDR SWIA2026032675699Crossbeam · corrodedFRAME 87 CORRODED WHERE RT CROSSBEAM CONNECTS. PERFORMED CROSSBEAM REPAIR ON FRAME 87 IAW ETD2026-170-005605.SDR CALA2026033014899Housing · corrodedCORROSION SPOTS AROUND LAV WASTE TANK INTERNAL DRAIN FLANGE AND HOUSING B.S. 847- B.S. 867. REMOVED AND REPLACED LAV WASTE HOUSING REF SRM 51-40-02-0G-0 AND DWG 146A7400.SDR EE4Y2026032624177Panel · corrodedCORROSION WAS DETECTED AT THE NLG WHEEL WELL RH PANEL, SPECIFICALLY IN THE REAR BELLCRANK REGION. THE SRM WAS CONSULTED FOR CORROSION REMOVAL AND EVALUATION, BUT NO APPLICABLE INSTRUCTIONS WERE FOUND. CONSEQUENTLY, THE CORROSION WAS REMOVED BY PERFORMING A SPOSDR SWIA2026032575698Beam · corrodedAFT WET AREA AT FR 88/89 RT BEAM CORRODED. REMOVED AND REPLACED AFT WET AREA FR 88/89 RH BEAM IAW SRM 51-40-08.SDR AALA202604104770Door Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN R1 GALLEY DOOR SURROUND STRUCTURE LOWER SILL INNER CHORD (CREASE ANGLE) AT STA 295 AND RBL 60. REPLACED INNER CHORD PER AARD 51-00-05-1.SDR YENA2026033100364Waste Box · corrodedDURING HEAVY MAINTENANCE: (WASTE BOX AREA CORROSION) CORROSION FOUND REAR BARREL BOTTOM SKIN PN C01342101-115 BET FR 75-FR79 AND STRG 31L- STRG 36L.; REF AVIANOR WO# JB-3023-AOG-01, NR# 3005. REAR BARREL BOTTOM SKIN PN; C01342101-115 BET FR75-FR79 AND STRG 31SDR UIEA2026031100081Lever · crackedMAIN DECK CARGO DOOR L5 FUSELAGE DOOR FRAME CUTOUT JUST OUTBOARD OF HOLD/OPEN RELEASED LEVER FOUND CRACK. CRACK ON MAIN DECK CARGO DOOR L5 FUSELAGE DOOR FRAME CUTOUT OUTBOARD OF HOLD/OPEN RELEASED LEVER, REPAIR CARRIED OUT AS PER B747-400F SRM 53-60-15-2R-7 RSDR UIEA2026031100085Splice · corrodedMAIN EE CTR SPLICE STRAP AT STATION 400 RBL 63 FOUND WITH SURFACE CORROSION.(<P>MAIN EE CTR SPLICE STRAP AT STATION 400 RBL 63 WORK ACCOMPLISHED IAW EN# 3155-26 REV 0. NO FURTHER DEFECTS NOTED. PN 65B07936-358SDR UIEA2026031800102Structure · corrodedDURING HFEC INSPECTION AT LOWER FUSELAGE AREA 2, FOUND CORROSION INDICATION AT STA 1718 - STA 1740 S45L. LOWER FUSELAGE AREA 2 STA 1718 - STA 1740 S45L WORK ACCOMPLISHED IAW EN #3190-26 REV 0. NO FURTHER DEFECTS NOTED.SDR REXA2026050700511Crossbeam · crackedAFTER RH CROSSBEAM REMOVAL, CRACK ON ANGLE RBL26.00 & LBL26.00 FS280.00 WAS FOUND AT FWD FACE OF THE BULKHEAD FS280.00, BELOW FLOOR ANGLE RBL26.00 & LBL26.00 FS280.00 AT FWD FACE OF THE BULKHEAD FS280.00, BELOW FLOOR WERE REPLACED PER CRJ900 SRM 51-42-06-001-SDR REXA2026050700510Crossbeam · crackedAFTER RH CROSSBEAM REMOVAL, CRACK ON ANGLE RBL26.00 & LBL26.00 FS280.00 WAS FOUND AT FWD FACE OF THE BULKHEAD FS280.00, BELOW FLOOR ANGLE RBL26.00 & LBL26.00 FS280.00 AT FWD FACE OF THE BULKHEAD FS280.00, BELOW FLOOR WERE REPLACED PER CRJ900 SRM 51-42-06-001-SDR AALA202605011964Door Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME AT #1 DOORSTOP FITTING AT FR 68 AND S22L. REPAIRED FRAME PER EA 374075.SDR SWAA2026043082775Stub Frame · crackedCRACKED R1 DOOR STUB FRAME, BETWEEN BS 291.5 - 303, S7 - 9R, REPLACED THE STUB FRAME IAW SRM 53-10-01-2R-6, REPAIR 6, PARAGRAPH 4.N, & DWG 141A8370, SHEET 10, REV D.SDR SWAA2026042482768Tie Clip · crackedCRACK ON TIE CLIP LOCATED BS 500I AT LEVEL STR 26R AT FWD CARGO COMPARTMENT. REPLACED TIE CLIP LOCATED BS 500I AT LEVEL STR 26R AT FWD CARGO COMPARTMENT IAW B737-800 SRM 51-40-02-0G-0 AND DWG: 143A1234 SHEET 14 REV A.SDR SWAA2026032782691Crossbeam · crackedFWD CARGO BAY BS 540 AT FLOOR LEVEL AND RIGHT OF BL 0, EXPANSION JOINT BREAK PANEL ASSEMBLY CRACKED. REMOVED AND REPLACED BREAK PANEL ASSEMBLY IAW SRM 51-40-02-0G-0-B00069.SDR DALA2026032702023Shim · installedGAP BETWEEN R/H S-18 WEB AND STA 727 INNER CHORD FOUND TO BE GREATER THAN 0.006" (0.033") PER FORECAST CARD 38-0553-8-0151. WORK CARD 5311-01251-01B STEP 11.SDR DALA2026032702022Shim · installedGAP BETWEEN L/H S-18 WEB AND STA 727 INNER CHORD FOUND TO BE GREATER THAN 0.006" (0.020") PER FORECAST CARD 38-0553-8-0148 WORK CARD 5311-01251-01A STEP 11. INSTALLED SHIM PER FORECAST CARD 38-0553-8-0154 WORK CARD 5311-01251-02A. ASSOCIATED AA 5311-01251.SDR AALA202603261129Tee Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: THE T-CAP AT BS 947.5 AND RBL 23.5 HAS A DEEP SPOT OF OUT OF LIMITS CORROSION. REMOVED AND REPLACE T-CAP. PER N/R SER#455.SDR SWAA2026042782594Support Beam · crackedCRACKED SUPPORT BEAM NR 4, FWD GALLEY DOOR. REPLACED THE NR 4 SUPPORT BEAM IAW SRM 51-40-02, SRM 51-10-02-0G-0, ITEM 9, AND DWG 141A6516, SHEET 142, REV-, DWG 141A6535, SHEET 13, REV-.SDR SWAA2026042882319Tie Clip · crackedCRACKED TIE CLIP, BS 277, STR 10R. REPLACED THE TIE CLIP IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, DWG 141A1110, SHEET 55, REV -, & DWG 141A8380, SHEET 21, REV -.SDR SWAA2026042889618Access Panel · crackedCRACK ON ACCESS PANEL 211B AT FLIGHT COMPARTMENT. REPLACED ACCESS PANEL 211B AT FLIGHT COMPARTMENT IAW AMM 27-41-61-410-801 STEP 3B(1).SDR IPXA2026040110702Fitting · crackedFOUND THE MAIN DECK CARGO RESTRAINT FLOOR ADAPTER FITTING WITH CRACK DAMAGE AT BS 632, BL 0, FLOOR PANEL. JOB COMPLETED AND CONDITION CHECK NORMAL. REPLACED FLOOR ADAPTER FITTING I.A.W AMM 20-11-00-910-802 REV.147 AND TORQUE BOLT TO 85 IN-LB.SDR CALA2026032714858Floor Skin · corrodedNLG LH SIDE TROUGHT ACCESS PANEL 115AL, FLOOR SKIN CORRODED NEAR TO DRAIN HOLE BS 324. ACCOMPLISHED REPAIR ON THE NOSE WHEEL WEEL SIDE PANEL STA 324 CHORD PER EC/RA 5310-08831 AND FINAL VTMAE EA 757-5310-13-A4296 WI TH NO DEVIATIONS. CREATED LOGPAGES PER UALSDR IPXA2026032612437Housing · stuckSTUCK - HOUSING ASSY, FWD CARGO DOOR CUTOUT AFT SIDE (REPLACE). I.A.W AMM 20-11-00-910-802 REV.147 REPLACE FWD CARGO DOOR HOUSING ASSY AT AFT SIDE CUTOUT AREA. IAW AMM 52-33-00-825-013,REV.147, CHECK THE FWD CARGO DOOR FLUSHNESS.SDR JR2R20260326105Doubler · corrodedRIGHT FLOOR DOUBLER CORRODED FR12 - FR14 AND RBL36 - RBL48. REPLACEDSDR AALA202603256715Door Frame · looseAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR VERY DIFFICULT TO OPEN AND CLOSE FROM FLIGHT DECK SIDE IN CRUISE FLIGHT. MAINTENACE FOUND DOOR FRAME LOOSE AND TIGHTENED SCREWS IN DOOR FRAME PER AMM 52-51-00. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED WITH NSDR REXA2026041500286Door Sill · corrodedPASSENGER DOOR SILL MID CAP ANGLE IS CORRODED BETWEEN F.S.310 TO F.S.349 REMOVED THE PAX DOOR MID CAP ANGLE BY REMOVING 4 EA SCREWS IAW CRJ-900 SRM 51-41-04-001-001-A01 LOCATED AND DRILLED NEW SERVICEABLE PAX DOOR MID CAP ANGLE PN SH670-31825-9S IAW CRJ-900 SRSDR AALA202604106637Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON R1 GALLEY DOOR SURROUND STRUCTURE LOWER SILL INNER CHORD (CREASE ANGLE) AT STA 324 AND RBL 60. REPLACED INNER CHORD PER AARD 51-00-05-1.SDR AALA202603266720Crossbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR SUPPORT BREAK ASSEMBLY PANEL AT BS 540 AND LBL 1. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1.SDR AALA202603261403Crossbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR SUPPORT BREAK ASSEMBLY PANEL AT BS 540 AND RBL 1. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1.SDR SWIA2026032077407Web · corrodedLH LOWER WEB AT FS 280 HAS CORROSION 31921541 C-CHECK RO 09302026REPAIRED LH LOWER WEB AT FS 280 REF CRJ700 SRM 53-11-10-201-003-A01 REPAIR BSDR AALA202604147065Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LOWER SILL INNER CHORD (CREASE ANGLE) AT STA 985 AND RBL 54. REPLACED INNER CHORD PER AARD 51-00-05-1.SDR IPXA2026040178532Fitting · crackedFOUND THE MAIN DECK CARGO RESTRAINT FLOOR ADAPTER FITTING WITH CRACK DAMAGE AT BS 1373, RBL 47.5, FLOOR PANEL 252QFF. INSTALLED FLOOR PANEL 252QFF IAW AMM 53-01-06-400-801, REV.147. REPLACED FLOOR ADAPTER FITTING I.A.W AMM 20-11-00-910-802 REV.147 AND TORSDR IPXA2026040178536Fitting · crackedFOUND THE MAIN DECK CARGO RESTRAINT FLOOR ADAPTER FITTING WITH CRACK DAMAGE AT BS 676, RBL 47.5, FLOOR PANEL 232LFF. INSTALLED FLOOR PANEL 232LFF IAW AMM 53-01-06-400-801, REV 147. REPLACE FLOOR ADAPTER FITTING I.A.W AMM 20-11-00-910-802 REV.147 AND TORQUESDR IPXA2026040178528Fitting · crackedFOUND THE MAIN DECK CARGO RESTRAINT FLOOR ADAPTER FITTING WITH CRACK DAMAGE AT BS 654+44 BL 0, FLOOR PANEL 231LFF. REPLACE FLOOR ADAPTER FITTING I.A.W AMM 20-11-00-910-802 REV.147 AND TORQUE BOLT TO 85 IN-LB.SDR IPXA2026040178544Fitting · crackedFOUND THE MAIN DECK CARGO RESTRAINT FLOOR ADAPTER FITTING WITH CRACK DAMAGE AT STA 1241 BL 0, FLOOR PANEL NO. 251LFF (REPLACE). REPLACE FLOOR ADAPTER FITTING IAW AMM 20-11-00-910-802 REV.147 AND TORQUE BOLT TO 85 IN-LB.SDR IPXA2026032975575Plate · crackedFOUND THE PLATE ON SIDE GUIDE RAIL WITH CRACK DAMAGE AT BS 1219, LEFT SIDE IN AFT CARGO COMPARTMENT. INSTALLED NEW TIE PLATE IAW SRM 51-40-02-0G, REV 94, & AIPC 25-53-15-21, REV 141.SDR IPXA2026032978429Depressor · chafedCHAFING & DEFORM - FRAME , MAIN DECK CARGO DOOR CUTOUT AREA & AFT SIDE. INSTALL NUTPLATES ON NEW DEPRESSOR IAW SRM 51-40-02-0G REV. 94 AND DWG 143T1008, SHT, 11 REV. - & 143T8414 SH 1 REV. G AND 143T8414 SH 2 REV. A..SDR MASA20260325030Doubler · corrodedDURING HEAVY CHECK INSPECTIONS ON FWD FLOOR STRUCTURE, CORROSION FOUND ON FWD FUSE, FLOOR STRUCTURE, SILL DOUBLER BETWEEN FR 12-16 AND BETWEEN RBL 36-48. SILL DOUBLER REMOVED AND REPLACED SRM 51-41-02 AND 51-43-04, REV.53.SDR SWAA2026050481577Stub Frame · crackedCRACK INDICATION ON STUB FRAME LOCATED BETWEEN BS 294.5 TO BS 296.5 AND BTW S-8R TO S-9R AT FWD GALLEY DOOR AREA CRACK LENGTH 0.250 IN. REPLACED STUB FRAME LOCATED BS 294.5 AND BTW STR-6R TO STR-10R AT FWD GALLEY DOOR AREA IAW SRM 51-10-02-0G-0, ITEM 9, SRM 5SDR DALA2026032502003Pan · crackedREPAIR TO FUSELAGE AFT LAVATORY SERVICE PAN AT STA 1681-1701 AND S27R - 29R CRACKED. REQUIRES ACTIONS PER ERA 632865-14 REV ORIG. REF ERA 632865-14. (1502037)SDR AALA202603258015Receptacle · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: THROUGH 11000 FT WE GOT A CABIN ALTITUDE WARNING HORN, WE DESCENDED IMMEDIATELY BACK TO 10000 FT; RAN THE CHECKLIST AND COULD NOT GET THE AIRCRAFT TO PRESSURIZE. AIRCRAFT AIR INTERRUPTED BACK TO AND LANDSDR DALA2026032401967Frame · crackedCRACK WAS FOUND IN OVERWING FRAME TAB Y= 696 RH SIDE AT PAX CABIN. CORRECTIVE ACTION: OVERWING FRAME TAB Y= 696 RH SIDE AT PAX CABIN WAS REPLACED PER B717-200 SRM 51-41-02-0G, SRM 51-41-05 (1502762)SDR JR2R20260319098Doubler · corrodedAFT WET AREA TEXAS GUSSET AT FR90A RBL10 IS CORRODED. REPLACEDSDR JR2R20260319100Doubler · corrodedAFT WET AREA TEXAS GUSSET AT FR90 RBL24 IS CORRODED. REPLACED
Back to JASC 5310