JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201305201041Floorbeam · corrodedBS 1661, BL 0-LBL 24, FLOORBEAM UPPER TEE UPPER SURFACE FOUND CORRODED. FLOORBEAM FABRICATED IAW DWG 146N5110, SH 2 REV B AND INSTALLED IAW DWG 146N5090, SHT 5 REV- . REPAIR IS MAJOR.SDR FDEA201305201039Floorbeam · corrodedBS 1661, RBL 40-50 FLOORBEAM TEE UPPER SURFACE FOUND CORRODED. FLOORBEAM FABRICATED IAW DWG 146N5110, SHT 2 REV B AND INSTALLED IAW DWG 146N5090, SHT 5, REV. REPAIR IS MAJOR.SDR FDEA201305201037Floorbeam · corrodedBS 1661, RBL 56 FLOORBEAM UPPER TEE FOUND CORRODED. R & R FLOORBEAM FABRICATED IAW DWG 146N5110, SHT 2, REV B AND INSTALLED IAW DWG 146N5090, SHT 5, REV. REPAIR IS MAJOR.SDR FDEA201305201036Floorbeam · corrodedBS 345, BL 0-LBL 20 FLOORBEAM UPPER TEE AND LOWER SURFACES FOUND CORRODED. R & R WITH NEW FLOORBEAM FABRICATED IAW DWG 141N5121, SHT 4, REV AND INSTALLED IAW DWG 141N5111, SHT 1, REV C. MAJOR REPAIR.SDR FDEA201305201033Floorbeam · corrodedBS 345 BL 0-RBL 15, FLOORBEAM UPPER TEE SURFACE CORRODED. R & R WITH NEW FLOORBEAM FABRICATED IAW DWG 141N5121, SHT 4 REV AND INSTALLED IAW DWG 141N5111, SHT 1, REV C. MAJOR REPAIR.SDR FDEA201305201031Floorbeam · damagedFLOORBEAM AT BS 345, LBL 48 DAMAGED. R & R WITH NEW FLOORBEAM FABRICATED IAW DWG 141N5121, SHT 4 REV AND INSTALLED IAW DWG 141N5111, SHT 1, REV C. MAJOR REPAIR.SDR FDEA201305201029Floorbeam · corrodedBS 377.7, BL 0- RBL 54 FLOORBEAM UPPER TEE SURFACE FOUND CORRODED. R & R WITH NEW FLOORBEAM FABRICATED IAW DWG 141N5123, SHT.1 REV A AND INSTALLED IAW DWG141N5113, SHT 1, REV F. REPAIR IS MAJOR.SDR FDEA201305201028Floorbeam · corrodedBS 377.7, BL 0-RBL 24 FLOORBEAM UPPER TEE UPPER SURFACE FOUND CORRODED. R & R FLOORBEAM, FABRICATED IAW DWG 141N5123, SHT 1, REV A AND INSTALLED IAW DWG 141N5113, SHT 1, REV F. REPAIR IS MAJOR.SDR DALA1315980683Floorbeam · corrodedFWD CABIN FLOORBEAM HAS CORROSION BS 365.2, RBL26. REPAIRED IAW SRM 53-00-51, REPAIR 3 AND ERA 488913-14MA.SDR DALA1315960683Floorbeam · corrodedMAIN CABIN FLOORBEAM, BS 720, RBL 12-20 CORRODED. REPAIRED IAW SRM 53-00-51, REPAIR 3.SDR DALA1315930683Floorbeam · corrodedCORROSION ON UPPER SURFACE OF FLOORBEAM AT BS 1640, RBL 7. ACCOMPLISHED PERMANENT REPAIR IAW ERA 515037-14, REV ORIG.SDR DALA1315770683Floorbeam · corrodedFWD CABIN FLOORBEAM HAS CORROSION AT BS 440, LBL 10. ACCOMPLISHED PERMANENT REPAIR IAW ERA 481634-14 MA REV A.SDR ASAA2013051994984Floorbeam · corrodedON REMOVAL OF NR 2 FLOORBOARD, FOUND AFT CARGO FLOOR SPLICE AT BS 727F 7.6 CORRODED BLENDED CORROSION, FOUND TO BE OUT OF LIMITS, FABRICATED, ALODINED , PRIMED AND TOPCOATED NEW FLOORBOARD SPLICE IAW SRM 53-60-53-1A-1, FIG 101, 51-10-02-0G-0, 51-40-05-0G-0 ANDSDR USAA2013060400026Floorbeam · corrodedC4 CHECK-LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT BS365, RBL6. REPAIRED FLOORBEAM AT BS365, RBL6 IAW SRM 51-10-02, 53-00-51-1A & 53-00-51-2R.SDR ASAA2013051994969Floorbeam · corrodedON DISPLACING AFT CARGO FLOOR PANEL TO REPLACE NUTPLATE ON INCOMING DISCREPANCIES, FOUND FLOOR PANEL SPLICE TEE AT BS 772 TO BE CORRODED. REMOVED CORROSION ON FLOOR PANEL SPLICE TEE AT BS 772, FOUND TO BE OUT OF LIMITS AND FABRICATED NEW TEE IAW SRM 53-60-53SDR DALA13025280126Floorbeam · damagedFWD CARGO COMPT BS 434, LBL 20-30, FLOORBEAM ANCHOR NUTS DAMAGED. FLOORBEAM REPAIRED IAW SRM 53-00-07, REPAIR 4.SDR CALA2013052100321Floorbeam · corrodedPASSENGER COMPARTMENT AFT WET AREA, HEAVY CORROSION AT FLOORBEAM BS 947 LBL 53. FABRICATED REPAIR PARTS AND INSTALLED FLOORBEAM BS 947, IAW SRM 53-40-51, REPAIR 5.SDR DALA13023441402Floorbeam · corrodedCABIN FLOORBEAM AT BS 325 BETWEEN RBL 20 - 54.75 FOUND CORRODED. REPAIRED FROM LBL 45 TO RBL 60.SDR DALA13023431402Floorbeam · corrodedCABIN FLOORBEAM AT STA 325 BETWEEN RBL 20 -54.75 FOUND CORRODED. MX REPAIRED FROM LBL 45 TO RBL 60.SDR DALA13023421402Floorbeam · corrodedCABIN AT BS 347 RBL 55 +20 FLOORBEAM UPPER SURFACE FOUND CORRODED. REPAIRED FROM LBL 15 TO RBL 60.SDR DALA13023411402Floorbeam · corrodedCABIN AT STA 347 RBL 55 +20 FLOORBEAM UPPER SURFACE FOUND CORRODED. REPAIRED FROM LBL 15 TO RBL 60.SDR DALA13023401402Floorbeam · corrodedCABIN AT STA 347, RBL 55+20 FLOORBEAM UPPER SURFACE FOUND CORRODED. REPAIRED FROM LBL 15 TO RBL 60.SDR DALA13023391402Floorbeam · corrodedCABIN AT BS 347 RBL 55+20 FLOORBEAM UPPER SURFACE CORRODED. REPAIRED FROM LBL 15 TO RBL 60 IAW SRM 53-00-51, FIG 201, REPAIR 1, REV.SDR UALA2013052003458Floorbeam · damagedFLOORBEAM, BS 1600, RBL 8-11 DAMAGED. INSTALLED REPAIR STRAPS AND ANGLES. MAJOR REPAIR.SDR USAA2013061300004Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR47.2 TO FR47.4, S23L, Y1600. REPLACED FLOORBEAM BETWEEN FR47.2 TO FR47.4, S23L, Y1600 IAW SRM 51-72-11 & DWG D53259000.SDR USAA2013061300003Coupling · damaged2S CHECK - ELONGATED HOLE ON FLOORBEAM "Z" COUPLING AT FR47.4", S23L, Y1600. REPLACED FLOORBEAM "Z" COUPLING AT FR47.4", S23L, Y1600 IAW SRM 51-72-11 & DWG D53456807.SDR DALA13023500126Floorbeam · corrodedFLOORBEAM BS 325, RBL 28 -55, FOUND CORRODED, FLOORBEAM REPAIRED.SDR ASOA2013061903848Floorbeam · corrodedFLOORBEAM AT FS 1036, LBL 28L OUT OF LIMITS. CUT OUT CORRODED AREA OF FLOORBEAM AT FS 1036, LBL 28 AND COMPLIED WITH EC/TC EO 700-53-0253 AND SRM 51-21-11, 51-25-16, 51-25-06, 51-24-36, 51-40-11.SDR ASOA2013061903847Floorbeam · corrodedBS 280 FLOORBEAM CORRODED. R & R FLOORBEAM IAW SRM 51-42-06, 51-40-11, 51-42-13, AND 51-42-21, 51-25-16, 51-24-36, 51-21-11 AND 51-25-06.SDR ASOA2013061703824Floorbeam · corrodedCORROSION ON FLOORBEAM AT FS 1036, LBL 28. REPAIRED IAW CRJ 700 53-61-43.SDR ASOA2013060703779Floorbeam · corrodedBS 280 FLOORBEAM CORRODED. REMOVED BS 280 FLOORBEAM IAW SRM 51-42-06-001-001. LOCATED AND DRILLED NEW SERVICABLE FLOORBEAM IAW SRM 51-42-06-001-001. INSTALLED NEW FLOORBEAM IAW SRM 51-42-06-001-001-A01. REF DWG CC670-340-94.SDR ASOA2013060703778Floorbeam · corrodedFLOORBEAM CORRODED. REMOVED BS 280 FLOORBEAM IAW SRM 51-42-06-001-001. LOCATED AND DRILLED NEW SERVICABLE FLOORBEAM IAW SRM 51-42-06-001-001. INSTALLED NEW FLOORBEAM IAW SRM 51-42-06-001-001-A01, REF DWG CC670-340-94.SDR ASOA2013060703777Floorbeam · crackedCOCKPIT FLOORBEAM AT LBL 12 IS CRACKED AT FS 274. REPAIRED IAW REO 690-53-11-522.SDR ASOA2013060703776Floorbeam · crackedCOCKPIT FLOORBEAM AT RBL 12 IS CRACKED AT FS 274.00. REPAIRED IAW REO 690-53-11-522.SDR SWIA201333570Floorbeam · crackedRIGHT FLOORBEAM CRACKED AT FS 274. C-CHECK, REPAIRED RT FLOORBEAM AT FS 274 IAW REO.SDR SWIA201333569Floorbeam · crackedLEFT FLOORBEAM CRACKED AT FS 274. C-CHECK, REPAIRED FLOORBEAM AT FS 274 IAW REO.SDR UALA2013052003442Floorbeam · corrodedFLOORBEAM CORRODED AT BS 324, FROM RBL48-54. REMOVED DAMAGE, ORIGINAL MATERIAL .120", FOUND .016" REMOVED. HFEC INSPECTION, BLEND AREA REF NDT PT 6, 51-00-19, NO DEFECTS NOTED. IN LIMITS REF SRM 53-10-08, FIG 101. MAJOR REPAIR.SDR WX0A071588Floorbeam · corrodedAFT RIGHT LAV AT STA 1309 ON FRAME, AREAS OF CORROSION FWD OF PULLY ASSY. REPAIRED FLOORBEAM AT STA 1309 RBL 20. FABRICATED AND INSTALLED REPAIR STRAP.SDR CA130529006Floorbeam · corroded(CAN) DURING A HEAVY MAINTENANCE VISIT, THE FLOOR BEAM (LEFT HAND SIDE, BEHIND THE CAPTAIN`S SEAT) AT FS 280 WAS FOUND TO BE CORRODED. THE CORROSION WAS CLASSIFIED AS LEVEL 2 AND MEASURED 10" LENGTH X 1" WIDTH AND .018" DEPTH. THIS BEAM ITSELF IS .040" THE CORSDR UALA2013051703421Floorbeam · damagedMAIN CABIN BS 395, LBL 45, TWO HOLES IN FLOORBEAM TEE OUT OF ROUND. FABRICATED AND INSTALLED ANGLES AND FREEZE PLUGS IAW ECRA 5310-05745 AND EA 130470. MAJOR REPAIR.SDR USAA2013060400027Floorbeam · corrodedC4 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT BS740, RBL45. REPAIRED FLOORBEAM AT BS740, RBL45 IAW SRM 51-10-02, 53-00-51-1A & 53-00-51-2R.SDR UALA2013051703420Floorbeam · corrodedFLOORBEAM BS 365 CORRODED FROM RBL 4 TO 57. CUTOUT DAMAGE SECTION OF UPPER TEE, INSTALLED ATTACH ANGLE AND STRAPS AT BS 365 LBL 12- RBL 6 IAW ECRA 5310-05536, AND SRM 51-40-02. MAJOR REPAIR.SDR UALA2013051603416Floorbeam · corrodedCABIN FLOORBEAM, BS 345 HAS CORROSION FROM RBL 14-60. REMOVED DAMAGED SECTION OF T-CAP AND INSTALLED NEW SECTION T-CAP WITH TWO SLICE ANGLES IAW DWG 1518-338, REV C, AND ECRA 5310-05538. MAJOR REPAIR.SDR FDEA201305161009Floorbeam · corrodedFLOORBEAM TEE BS 1641 AND RBL 48-54 CORRODED. . FLOORBEAM WAS R & R IAW DWG 146N5109, SHT1, REV A AND 146N5089 SHT1 REV B. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.SDR FDEA201305161008Floorbeam · corrodedFLOORBEAM TEE CORRODED BS 378.5, LBL 26-31. FLOORBEAM WAS REMOVED AND REPLACED AS PER DWG 141N5123 SHT 1 REV A AND 141N5113 SHT 1 REV F. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.SDR V0XR20130517J0187Floorbeam · corrodedAFT CARGO COMPARTMENT FLOORBEAM CORRODED AT BS 1031 AND LBL 28. REPAIRED FLOORBEAM IAW REO 670-53-00-029 AND EO 700-53-0251.SDR UALA2013051603417Floorbeam · gougedMAIN CABIN FLOORBEAM BS 377 GOUGED AT LBL 28. REMOVED 3 INCHES OF SECTION OF UPPER TEE, INSTALLED FILLER AND ANGLE DOUBLER REPAIR IAW EC-RA 5310-05538. MAJOR REPAIRSDR SWAA2013061917399Floorbeam · crackedFLOORBEAM LOWER CHORD CRACKED AT BS 664, LBL 45.5. R & R CHORD IAW SRM AND DWG.SDR USAA2013061000037Splice · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON OTBD UPPER FLOORBEAM SPLICE AT FR67+16", Y1162.5. REPLACED OTBD UPPER FLOORBEAM SPLICE AT FR67+16", Y1162.5 IAW SRM 51-72-11 & DWG D53472088.SDR USAA2013061000036Splice · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON INBD UPPER FLOORBEAM SPLICE AT FR67+16", Y1162.5. REPLACED INBD UPPER FLOORBEAM SPLICE AT FR67+16", Y1162.5 IAW SRM 51-72-11 & DWG D53472088.
Back to JASC 5315