SDR USAA2011041291460Floorbeam · corrodedSAL - S4 - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR67 + 18 INCHES TO FR69 + 4 INCHES, -Y1162. REPLACED FLOORBEAM BETWEEN FR67 + 18 INCHES TO FR69 + 4 INCHES, -Y1162 IAW A319 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR USAA2011040891388Floorbeam · corrodedPIT - S4 - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR66,-Y465. REPLACED FLOORBEAM AT FR66,-Y465 IAW A319 SRM 53-41-14.SDR ASOA201100651Floorbeam · corrodedFLOORBEAM & CAP ARE CORRODED AT FS 349 BETWEEN RBL 27 & 45. REPAIRED IAW REO 601R-53-21-1262.SDR ASOA201100646Crossbeam · corrodedCORROSION ON FS 280 CROSSBEAM. REMOVED SURFACE CORROSION IAW SRM 51-21-03-001-001-A01. TREATED AREA, PRIMED, AND PAINTED IAW SRM 51-21-06-001-001-A01. MINOR REPAIR.SDR ASOA201100640Crossbeam · corrodedCORROSION ON FS 280 CROSSBEAM.SDR UALA2011032901498Floorbeam · corrodedSTATION 324 RBL 41 FLOORBEAM HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED FLOORBEAM STA 324, RBL 41 IAW PEMCO EA PD57-536-096.SDR SWAA112307Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND FLOORBEAM CRACKED AT BS 322, RBL 40. REPAIRED BEAM PER SRM.SDR SWAA112306Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND FLOORBEAM CRACKED AT BS 314, RBL 26. REPAIRED BEAM PER SRM.SDR CALA2011032900231Floorbeam · wornBS 246 FLOORBEAM LOWER WEB FOUND (1EA) HOLE ELONGATE AT RBL 1.5 INCH. BS 246 FLOORBEAM LOWER WEB ONE HOLE ELONGATE REPAIRED AS PER ECRA 5310-05364 REV AND FORM 44.0008 ATTACHED ITEM 1-9 ACCOMPLISHED (AT BL 0).SDR SWAA112248Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND FLOORBEAM CORRODED AT BS 328, LBL 28. REPAIRED BEAM PER SRM.SDR EIAA2011030Floorbeam · corrodedMAIN DECK FLOORBEAM UPPER CHORD EXFOLIATION CORROSION BS 520 RBL 53. REMOVED DAMAGE AREA AND INSTALLED NEW SECTION OF FLOORBEAM PER B747 SRM 51-40-04 FIG 1 AND 51-30-02 PG 8-9.SDR CALA2011032800213Floorbeam · corrodedAFT ENTRY FLOORBEAM STA 1640 CORRODED FROM BL 7L TO BL 10R. CUT OUT DAMAGE AND INSTALLED FLOORBEAM UPPER CHORD REPAIR 3 IAW SRM 53-00-51 FIG 201.SDR CALA2011032800212Floorbeam · corrodedMAIN CABIN FLOORBEAM 1641 BL 0 HAS CORROSION. REMOVED CORROSION FROM FLOORBEAM STA 1641. FOUND TO BE OUT OF LIMITS. REMOVED DAMAGE SECTION AND SPLICED IN NEW SECTION. REF S SRM 53-00-51 REPAIR 3.SDR CALA2011032800211Floorbeam · corrodedMID CABIN WET AREA FLOORBEAM STA 720 HAS CORROSION ON TOP SURFACE FROM BL 0 TO RBL 63. INSTALLED FLOORBEAM REPAIR AT STA 720 FROM BL 0 TO RBL 63 REF SRM 53-00-51 REPAIR 3.SDR U2RA478DHN016Floorbeam · corrodedFUSELAGE STA 1660, RBL 12, CORROSION ON FLOORBEAM AROUND HOLE.SDR FDEA201103271197Floorbeam · corrodedFLOORBEAM UPPER CHORD HAS CORROSION STA 1640 RT RBL 54. FLOORBEAM AT STA 1640 REMOVED AND REPLACED IAW SRM 51-40-02 REV 102. REPAIR IS CLASSIFIED AS MAJOR.SDR DALA1129070137Floorbeam · corrodedCABIN : STA 325, RBL 26.0, FLOORBEAM UPPER HORIZ FLANGE FOUND CORRODED. STA 325 FLOORBEAM UPPER HORIZ CORRODED FLANGE TRIMMED BET RBL 12.0 TO RBL 45.5 AND REPAIRED IAW SRM 53-00-51, REPAIR 1, FIG 201, OTIS.SDR DALA1129060137Floorbeam · corrodedCABIN AT STA 287, RBL 60.75 FLOORBEAM UPPER HORIZ FLANGE FOUND CORRODED. CORROSION FOUND ON EXISTING REPAIRED TEE :EXISTING REPAIRED TEE WITH CORROSION REMOVED AND NEW TEE FABRICATED AND INSTALLED IAW SRM 53-00-51, FIG 201, REPAIR 1 OTIS. AREA REPAIRED IAW SSDR FDEA201103271199Floorbeam · corrodedCABIN - FLOORBEAM STA 760, RBL 50 HAS CORROSION. REMOVED AND REPLACED WITH FABRICATED FLOORBEAM IAW SRM 51-40-02, REV 102. REPAIR IS CLASSIFIED AS MAJOR.SDR SWAA112225Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 667, LBL 24.5. REPAIRED BEAM PER ER AND EA.SDR SWAA112197Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, LBL 45.5. REPAIRED BEAM PER EO AND EA.SDR SWAA112196Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, RBL 45.5. REPAIRED BEAM PER EO AND EA.SDR CNMA20110025Floorbeam · corrodedFLOORBEAM UPPER FLANGE IS CORRODED ON UPPER SURFACE AT BS 287, APPROX BL 48. CUTOUT DAMAGED FLOORBEAM IAW SRM CH 53-00-51, FIG 201. EDDY CURRENT INSP. REQUIRED-EDDY CURRENT CUTOUT AREA IAW NDT MANUAL PART 6 51-00-19. NO DEFECTS NOTED. FLOORBEAMS REQUIRES REPASDR CNMA2011Floorbeam · corrodedFLOORBEAM AT STA 1480, RBL 48-57 IS CORRODED ON UPPER FLANGE. AREA UNDER F4 LAV. REPAIRED CORRODED FLOORBEAM IAW REA 46824, REA 01.SDR CNMA20110021Strap · corrodedFLOORBEAM CORRODED JUST INBD OF R2 CUT OUT. REMOVED AND FABRICATED AND REPLACED FLOOR SUPPORT GUSSET STRAP IAW SRM 51-40-02 PARA 4 & 7.SDR CNMA20110019Floorbeam · corrodedFLOORBEAM AT FS 1518 AND BL -0- IS CORRODED AT LOWER END. REPAIRED LOWER FLANGE OF FLOORBEAM, PN 146T5143-1 IAW SRM 51-70-12, REF RFTS T-46825. REMOVED NUTPLATES ON FLOORBEAM AT STA 1518 AT LOCATION 12L AND 24L. REMOVED CORROSION. REMOVED CORROSION IAW SRSDR DALA1123301802Floorbeam · corrodedSTA 325 RBL 26 TO RBL 54 FLOORBEAM FOUND CORRODED. REPAIRED PER SRM 53-00-51 REPAIR 1 FIG 201.SDR SWAA112329Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND LONGITUDINAL FLOORBEAM CRACKED AT BS 663, RBL 24.5. REPAIRED BEAM PER EA.SDR COEA2011032610903Floorbeam · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: CORROSION ON UPPER FLANGE OF FLOORBEAM 9 AT PILOTS/COPILOTS SEAT FITTINGS. REPAIR PER STRUCTURAL REPAIR INSTRUCTIONS AND STRUCTURAL REPAIR APPROVAL SHEET FROM ATR.SDR CALA2011032800207Floorbeam · corrodedCABIN BS 347 RBL 45 FLOORBEAM CORRODED. CABIN BS 347 RBL 45 FLOORBEAM UPPER CHORD CORROSION REMOVED OUT OFF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT AND CHORD UPPER CHORD REPAIRED AS PER SRM 53-00-51 FIG 201 REPAIR 2.SDR A6WA201140312Floorbeam · corrodedLBL 27 AFT FLOORBEAM HAS CORROSION AT NUTPLATE. REMOVED DAMAGED FLOORBEAM AT LBL 27 & REPLACED WITH SERVICEABLE PART MADE FROM N126-1577 EXTENSION IAW SRM 51-42-21 & REO 601R-53-61-3778.SDR DALA1131010623Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED STA 720 LBL 62 / ACCOMPLISHED ERA PER SRM 53-00-51 PG 103 FIG 101 DET III.SDR DALA1130960623Floorbeam · gougedMAIN CABIN FLOORBEAM UPPER REPAIR HAS FLOORBOARD SCREW HOLE DRILLED THRU EDGE OF REPAIR FASTENER ON FWD FLANGE AND GOUGE ON AFT FLANGE STA 377.7 LBL 10 / ACCOMPLISHED ERA PER SRM 53-00-51 PG 201 FIG 201.SDR USAA2011040791366Floorbeam · corrodedPIT - S4 - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR20 TO FR21, Y254. REPLACED FLOOR BEAM AT FR16, Y254 IAW A319 SRM 51-72-11.SDR USAA2011040791365Floorbeam · corrodedPIT - S4 - LEVEL 2 CORROSION ON FLOORBEAM AT FR16, Y254. REPLACED FLOORBEAM AT FR16, Y254 IAW A319 SRM 51-72-11.SDR AALA20110404AFW04Floorbeam · corrodedCORROSION TO THE UPPER CAP OF THE STATION 347 PASSENGER FLOORBEAM AT RIGHT BUTTLINE 49.5. BLENDED CORROSION PER SRM CH 51, PERFORMED DVI, FABRICATED REPAIR PARTS, TREATED AND SEALED. ACCOMPLISHED REPAIR PER EA B767-53-015781.SDR AALA20110404AFW03Floorbeam · corrodedCORROSION WAS FOUND AT STATION 325 FLOORBEAM UPPER CAP HORIZONTAL FLANGE UPPER SURFACE. REMOVED ALL CORROSION PER 767-300 SRM 51-10. ACCOMPLISHED REPAIR PER EA B767-53-015766.SDR UALA2011032501434Floorbeam · corrodedCORROSION ON CABIN FLOOR BEAM AT STA 1640 AT RBL 14 TO RBL 40. MAJOR REPAIR ACCOMPLISHED: REMOVED TEE ANGLE IAW SRM, DUE TO EXCESSIVE MATERIAL REMOVED AND OUT OF LIMITS. FABRICATED REPLACEMENT TEE CHORD & INSTALLED PER SRM. TREATED AND PRIMED IAW SRM. TOP COASDR UALA2011032501433Floorbeam · corrodedSTATION 365.25 RBL 0 TO RBL 40 FLOORBEAM IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND ARE TO BE OUT OF LIMITS. REMOVED TEE CHORD AND ATTACHING ANGLE. FABRICATED TEE CHORD AND SUPPORT ANGLES. TREATED & PRIMED PARTS PER SRM. INSTALLED TEE SDR UALA2011032501432Floorbeam · corrodedFLOORBEAM HAS CORROSION AT STATION 1661 LBL 11 AND RBL 4. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED AREA OF TOP CHORD AND FABRICATED REPLACEMENT BEAM AND 2 SUPPORT ANGLE AND 2 STRAPS IAW SRM. TREATED AND PRSDR FDEA201103251176Floorbeam · crackedFWD CARGO COMPARTMENT MAIN DECK FLOORBEAM AT FRAME 25 HAS A 0.25 IN CRACK ON THE UPPER END OF THE VERTICAL STIFFENER BETWEEN SEAT TRACKS R3 AND R2. REMOVED DAMAGED AREA, AND REPAIRED IAW SRM 53-10-15 PAGE 393 THRU PAGE 399. FIG 212.SDR FDEA201103251175Floorbeam · crackedFWD CARGO COMPARTMENT FLOORBEAM AT FR23 HAS A 0.5 IN CRACK AT UPPER END OF VERTICAL STIFFENER BETWEEN SEAT TRACKS R1 AND R2. REMOVED DAMAGED AREA, NDT CHECKED FOR CRACKS-CHECKED GOOD, FABRICATED REPAIR ANGLE AND REPAIRED DAMAGED AREA.SDR FDEA201103251174Floorbeam · crackedFWD CARGO COMPARTMENT FLOORBEAM AT FR 21 HAS A CRACK AT VERTICAL (UPPER END) BETWEEN SEAT TRACKS R2 AND R3, CRACK MEASURES APPROX .75 IN LONG. REF AMM 53-13-11-06-0. CRACK IS ON VERT STIFFENER. REMOVED DAMAGED AREA, NDT CHECKED FOR CRACKS-CHECKED GOOD, FABRICSDR CALA2011032500185Floorbeam · corrodedFWD CABIN BS 325 LBL 35-40 FLOORBEAM SURFACE CORROSION REVEALED. FWD CABIN BS 325 LBL 35-40 FLOORBEAM UPPER CHORD CORROSION REMOVED OUT OF SRM 53-00-01 ALLOWABLE DAMAGED FIG 101 LIMIT & CORRODED UPPER CHORD REPAIRED AS PER SRM 53-00-51 FIG 201 REPAIR AT BS 32SDR FDEA201103241164Floorbeam · damagedFLOORBEAM AT BS 1260 RBL 30 HAS A DOUBLE DRILLED FASTENER HOLE IN UPPER CHORD. REPAIRED AS PER E.A. F-5310-146434. REPAIR IS CLASSIFIED AS MAJOR.SDR UALA2011032501431Floorbeam · corrodedSTA. 1640 FLOORBEAM CORR. 0 BL TO 59 RBL, TOP FLG. MAJOR REPAIR ACCOMPLISHED: REPAIRED PER SRM, REPAIR. NR 5, ON SM W-US E9906H, E9917H & E9959H.SDR UALA2011032501414Floorbeam · corrodedFLOORBEAM HAS EVIDENCE OF CORROSION AT STA 1640 FROM BL 64 TO BL 0. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION REMOVAL AREA OF FLOORBEAM WAS OUT OF LIMITS PER SRM. REMOVED DAMAGE UPPER CHORD AT STA 1640 LBL 10 - RBL 65. PERFORMED NDT OF CUT OUT AND FOUND SDR ASOA201100595Floorbeam · corrodedUPPER SURFACE OF FLOOR SUPPORT CROSSMEMBER TAB CORRODED AT FS 310.00 & LBL 9. REMOVED CORROSION IAW SRM 51-21-06 TREATED EFFECTED AREA IAW SRM 51-21-11 AND PRIMED IAW SRM 51-25-06.SDR ASOA201100594Floorbeam · corrodedUPPER SURFACE OF FLOOR SUPPORT CROSSMEMBER CORRODED AT FS 318.00 & LBL 9. REMOVED CORROSION IAW SRM 51-21-06 ALODINED EFFECTED AREA IAW SRM 51-21-11 AND PRIMED IAW SRM 51-25-06.SDR COEA2011032454805Floorbeam · damagedHEAVY CK COE / MAJOR REPAIR: FLOORBEAM 23A HAS TOOLING MARKS ON TOP OF FLANGE AT BL5R. MEASUREMENT AT TOOL MARK ON FLOORBEAM 23A TOP FLANGE .035 OUT OF LIMITS. FABRICATED AND INSTALLED FLOORBEAM 23A.
Back to JASC 5315