SDR 08FDEA02455Floorbeam · corrodedBULK CARGO BAY UNDER FLOOR AREA STA FR 66, AND BETWEEN LBL 26 TO LBL43, FLOOR SUPPORT AND "T" CHANNEL HAS CORROSION. REMOVED AND REPLACED "T" CHANNEL/FLOOR SUPPORT ASSEMBLY IAW SRM 51-40-44 AND 51-40-21.SDR 2010FA0000354Floorbeam · cracked(KADY) CRACK AT FLOORBEAM WEB AT UPPER DECK BS 340, 400, AND 500. MAJOR REPAIR ACCOMPLISHED BY TRIM OUT THE CRACKED FLOORBEAM AND INSTALL REPAIR FILLER AND REPAIR DOUBLER.SDR SWIA200820221Floorbeam · crackedFS 280 FLOORBEAM CRACKED RBL 9.0. C-CHECK, REPAIRED PER SRM.SDR SWIA200820219Floorbeam · crackedCOCKPIT FLOORBEAM IS CORRODED AND CRACKED. C-CHECK, REPAIRED PER SRM.SDR SWIA200820218Floorbeam · corrodedLT FS 280 FLOORBEAM CORRODED. C-CHECK, REPAIRED PER SRM.SDR SWIA200820217Floorbeam · crackedFS 280 FLOORBEAM CRACKED. C-CHECK, REPAIRED PER SRM.SDR TRAX200800830Floorbeam · crackedFS 280 RBL 9.0 O/B CLIP CRACKED. REMOVED OLD CRACKED CLIP AT FS 280.00 RBL 9 O/B. INSTALLED NEW SERVICEABLE CLIP IAW CRJ 200 SRM 51-42-21.SDR 08FDEA02432Floorbeam · corrodedMAIN CABIN FLOORBEAM STA 1640 RBL 47-51 HAS CORROSION BLENDED AREA IAW SRM 51-10-02, ORIG MAT. .125 AFTER 0.90 FOUND OUT LIMITS, IAW SRM 53-00-51 PAGE 103, CUT OUT DAMAGED AREA STA 1640 BET RBL36.5 TO RBL 68.5, IAW SRM 53-00-51 PAGE 201. RECEIVED REPAIR PARTSSDR 08FDEA02431Floorbeam · corrodedSTA 377.7, BL0 TO LBL 45 HAS CORROSION AROUND NUT PLATE HOLES. REMOVED DAMAGED AREA, LBL 13 TO LBL 70, BS 377.7 IAW SRM 53-00-51, FIG 201, REPAIR NR 3. FABRICATED T-CHORD AND SHIM IAW SRM 53-00-51, REPAIR NR 3. FABRICATED STRAP NR 4 AND NR 5 ON TRAVELER NR SDR 08FDEA02430Floorbeam · damagedPASS CABIN AT STA 760 CARGO FLOOR SUPPORT NUT PLATE IS MIS-DRILLED AT RBL 4, WL 208. REMOVED FLOOR SUPPORT CHANNEL, LOCATED, DRILLED, AND INSTALLED NEW FLOOR SUPPORT P/N 65-25589-6, A18848, PO NR 1038952 REF SRM 51-30-5 PG 6, 51-30-2 PG 4.SDR A6WA200840527Floorbeam · crackedCRACK FOUND ON CROSS BEAM AT FS 280.00 RBL 9.0. CROSS BEAM AT FS 280.00 RBL 9 REPAIRED IAW CRJ 200 REO 601R-53-11-171 REV D SCHEME A. (A)SDR A6WA200840526Floorbeam · crackedCRACK FOUND ON CROSS BEAM AT FS 280.00 LBL 9.0. CROSS BEAM AT FS 280.00 LBL 9 REPAIRED IAW CRJ 200 REO 601R-53-11-171 REV D SCHEME A. (A)SDR 2008UALA03562Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM UPPER FLANGE REPAIR DOUBLER AT BS 365 RBL 7. REMOVED DAMAGE, FABRICATED AND INSTALLED NEW DOUBLER AND FILLER IAW SRM 53-00-98SDR 2008UALA03561Floorbeam · corrodedMAIN CABIN FLOOR BEAM AT STA 1640, BL0 TO RBL 57, CORROSION ON TOP AND BOTTOM SIDES OF T-CAP. REMOVED DAMAGE FABRICATED T-CAP AND INSTALLED IAW SRM 53-00-98.SDR 2008UALA03560Floorbeam · corrodedFOUND CORROSION ON FLOOR BEAM UPPER FLANGE IN SEVERAL SPOTS BETWEEN BL0 TO RBL 64 AT BS 365, MAIN DECK FLOOR. REMOVED DAMAGE FABRICATED T-CAP AND INSTALLED IAW SRM 53-00-98SDR 2008UALA03556Floorbeam · corrodedMAIN CABIN BS 324 FLOORBEAM UPPER T -CAP CORRODED RBL 50. REPLACED T-CAP IAW SRM 51- 40-02.SDR 08FDEA02377Floorbeam · corrodedLT FUSELAGE FWD OF BS900 SUPPORT ANGLE HAS SURFACE CORROSION. CHORD REMOVED AND REPLACED IAW B757-200 SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR SWAA083453Floorbeam · corrodedDURING SCHEDULED SPV CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 986, RBL 32 TO RBL 41. REMOVED AND REPLACED CHORD PER SRM.SDR SWIA200820239Floorbeam · crackedFS 280 FLOORBEAM ATTACH CLIPS AT LBL 9 ARE CRACKED. C-CHECK, REPLACED CLIPS.SDR SWIA200820238Floorbeam · crackedCRACKED WEB ON FLOOR ANGLE AT FS 280 LBL 9 LOWER FLANGE. C-CHECK, REPAIRED PER REO.SDR SWIA200820237Floorbeam · crackedLEFT FS 625 OBLIQUE ANGLE CRACKED. C-CHECK, REPLACED ANGLE.SDR SWIA200820235Floorbeam · crackedAFT CAP ANGLE ATTACHED TO FS 280 IS CRACKED AT OUTBOARD SIDE OF LBL9 AND RBL9. C-CHECK, REPAIRED PER REO.SDR COMA0860297Floorbeam · crackedDURING HMV NR 6 INSPECTION, NDT INSPECTION FOUND A CRACK ON THE FS 559 LBL 18, LOWER CAP ANGLE. CUT OUT DAMAGE SECTION OF CAP ANGLE AND SPLICED IN NEW SECTION WITH DOUBLERS IN ACCORDANCE WITH REO 601R 53-41-260. (S)SDR KCSA081296Floorbeam · corrodedSTA-1265 FLOOR INTERCOSTAL, UPPER CHORD HAS CORROSION ON AFT SIDE UPPER FLANGE RBL-108 AT NUT PLATE HOLES. (B)SDR TRAX200800809Floorbeam · crackedFS 280.00 FLOORBEAM OUTBOARD CLIP AT RBL 9 IS CRACKED. REMOVED AND REPLACED BROKEN CLIP WITH NEW AT RBL 9 FS 280 FLOORBEAM OUTBOARD, ALSO FOUND INBOARD CLIP NEEDED REPLACING AND REPLACED SAME. WORK DONE IAW CRJ200 SRM 51-42-20. (S)SDR TRAX200800808Floorbeam · crackedFL280.00 FLOORBEAM INBOARD AND OUTBOARD CLIP AT LBL 9 ARE CRACKED. REMOVED AND REPLACED BROKEN CLIPS WITH NEW CLIPS AT LBL 9 FS 280 FLOORBEAM, INBOARD AND OUTBOARD. WORK DONE IAW CRJ200 SRM 51-42-20. (S)SDR F3LA200800379Floorbeam · corrodedDURING C-CHECK INSP NOTED RT CABIN FLOOR LOGERON BEAM Y1732 AT FRAME 66 HAS CORROSION AROUND FASTENER HOLE. MAINT FABRICATED ANGLES AND FILLER AND ACCOMPLISHED DETAILED REPAIR IAW EA A0-53F-12234, EA A0-53R-30370 AND SRM 53-41-14. UPON COMPLETION OF THE REPAISDR 08FDEA02358Floorbeam · crackedAFT CARGO COMPARTMENT FRAME 54.3 FLOORBEAM AFT SIDE BETWEEN SEAT TRACKS 2 RT AND 3 RT VERTICLE STIFFENER HAS 2 CRACKS .250 IN LONG EACH REMOVED DAMAGED SECTION AND INSTALLED CROSSBEAM CRACK REPAIR AT FR 54.3, BETWEEN SEAT TRACKS 2 RT AND 3 RT IAW FDEDEX EA 6-5SDR CALA0800624Floorbeam · corrodedFLOORBEAM AT BODY STATION 1016 LBL 37 HAS CORROSION ON UPPER FLANGE. FABRICATED NEW FLOOR PAN IAW BAC DWG 65C33582 FABRICATED T-CAP REPAIR STRAP IAW SRM 53-00-51, ALODINED AND PRIMED IAW SRM 51-20-01, INSTALLED FLOOR PAN DIP PAN GALLEY MOUNTS T-ANGLE AND REPASDR CALA0800620Floorbeam · corrodedSIGNS OF CORROSION ON T-CAP STATION 1016 BL29RT. BLENDED CORROSION ON BS 1016 FLOORBEAM AT RBL 29 DAMAGE FOUND TO BE BEYOND LIMITATIONS PER 737-500 SRM 53-60-51 FIG 101, FABRICATED AND INSTALLED REPAIR PER 737-500 SRM 53-00-51 FIG 201.SDR F3LA200800373Floorbeam · damagedDURING C-CHECK INSP, NOTED LT CABIN FLOOR LONGERON BEAM Y1732 AT FRAME 66 HAS CORROSION AROUND FASTENER HOLE. MAINT FABRICATED REPAIR ANGLES AND FILLER AND ACCOMPLISHED REPAIR IAW EA A0-53F-12234, EA A0-53T-12235, SRM 53-41-14 FIGURE 201 AND SRM 53-51-14 FIGUSDR KCSA081293Floorbeam · corrodedMAIN DECK FLOORBEAM INTERCOSTAL UPPER CHORD CORRODED B.S. 1265, LBL-108 (B)SDR 2008UALA03486Floorbeam · crackedMAIN CABIN FLOORBEAM AT BS 246, AFT FACE UPPER ANGLE CRACKED, LBL 11. *S/D* FOUND UPPER CHORD CRACKED. REMOVED DAMAGE, FABRICATED NEW UPPER CHORD AND INSTALLED IAW SRM 53-10-51.SDR SWAA083408Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOOR BEAM UPPER CHORD CORRODED AT BS 328, RBL 12 TO RBL 48. R&R CHORD PER SRM.SDR SWAA083401Floorbeam · corrodedDURING SCHEDULED SPV CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 294, BL 0 TO RBL 4. REPAIRED CHORD PER SRM.SDR SWAA083398Floorbeam · crackedDURING SCHEDULED SPV CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER TEE CHORD CRACKED BETWEEN BS 655 AND BS 675, LBL 25. R&R CHORD PER SRM.SDR SWAA083371Floorbeam · corrodedDURING SCHEDULED SPV CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 968, RBL 28 TO RBL 45. REPAIRED FLOORBEAM PER SRM.SDR CALA0800613Floorbeam · corrodedFLOORBEAM AT STATION 698 HAS CORROSION AROUND FASTENER HOLE. REMOVED CORRODED FLOOR, SUPPORT FITTING, FABRICATED AND INSTALLED NEW FITTING REF GMM 10-900-01, SRM 51-40-02 AND BOEING DRAWING 143N5432-1.SDR 2008UALA03464Floorbeam · corrodedCORROSION FOUND AT BS 805, LBL 11, UNDER MAIN CABIN FLOOR. *S/D* SUSPECT MOISTURE CONTAMINATION. CUT OUT DAMAGED SECTION OF T-CAP SPLICED IN NEW SECTION PER SRM 53-00-51, SRM 51-20-01 AND SRM 51-40-02. AC OK FOR SERVICE.
SDR 2008UALA03465Stiffener · crackedE&E COMPARTMENT AT STA 246 FLOORBEAM AND LBL 40 HAS CRACKED VERTICAL STIFFENER. REPLACED CRACKED STIFFENER. FABRICATED & INSTALLED NEW REPAIR.SDR 08FDEA02307Floorbeam · corrodedCORROSION FOUND ON FLOOR SUPPORT AT BS 748, RBL 12. CORROSION FOUND EXCEED ALLOWABLE LIMITS IN B757-200 SRM 51-10-02. REMOVED AND REPLACED FLOOR SUPPORT STRINGER IAW B757-200 SRM 51-10-02 AND SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-10SDR 08FDEA02306Floorbeam · corrodedCORROSION FOUND ON FLOOR SUPPORT AT BS 750, LBL4. CORROSION FOUND EXCEED ALLOWABLE LIMITS IN B757-200 SRM 51-10-02. REMOVED AND REPLACED FLOOR SUPPORT STRINGER IAW B757-200 SRM 51-10-02 AND SRM 51-40-02 REV.93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-1SDR 08FDEA02305Floorbeam · corrodedCORROSION FOUND ON FLOOR SUPPORT AT BS750, LBL 8. CORROSION FOUND EXCEED ALLOWABLE DAMAGE LIMITS IN SRM 51-10-02. REMOVED AND REPLACED FLOOR SUPPORT STRINGER IAW B757-200 SRM 51-10-02 AND SRM 51-40-02 REV 93. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRSDR SWAA083364Floorbeam · corrodedDURING SCHEDULED SPV CHECK, FOUND FLOORBEAM CORRODED AT BS 312, LBL 11 TO LBL 19. REPAIRED FLOORBEAM PER SRM.SDR SWAA083365Floorbeam · corrodedDURING SCHEDULED SPV CHECK, FOUND FLOORBEAM CORRODED AT BS 986, LBL 16 TO RBL 37. REPAIRED FLOORBEAM PER SRM.SDR SWAA083325Floorbeam · crackedDURING SCHEDULED SPV CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER TEE CHORD CRACKED BETWEEN BS 655 AND BS 675, RBL 25. REMOVED AND REPLACED TEE CHORD PER SRM.SDR 2008UALA03445Floorbeam · wornMAIN CABIN FLOORBEAM UPPER SURFACE HAS WEAR MARKS AROUND FASTENER HOLE AT BS 764 BETWEEN RBL 20 AND RBL 54. *S/D* SUSPECT TOOLING MARKS. REMOVED DAMAGE AREA, FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-51 FIG 201 TABLE I. AC OK FOR SERVICE.SDR 2008UALA03444Floorbeam · corrodedCABIN FLOORBEAM AT BS 805, RBL 11 IS CORRODED. REMOVED DAMAGE, FABRICATED NEW REPAIR AND INSTALLED IAW SRM 53-00-51 AND SRM 51-40-02. AC OK FOR SERVICE.SDR 2008UALA03443Floorbeam · crackedSTA 303, RBL 88.5, CRACK ON FLOORBEAM. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED T-CHORD, REPAIR SPLICE & STRAP.SDR SWIA200820234Floorbeam · corrodedFS 280 FLOORBEAM CORRODED ON TOP FROM LBL 2.0 TO RBL 2.0. C-CHECK, REPAIRED PER SRM.