SDR 2002F00946Floorbeam · corrodedDURING SCHEDULED INSPECTION CABIN FLOOR SUPPORT WAS DISCOVERED CORRODED ON FLOORBEAM FUSELAGE STATION 345, BUTTLINE 9 LEFT TO BUTTLINE 20 LEFT. CORROSION WAS LEVEL 2. MAINTENANCE REPAIRED CORROSION ON FLOOR BEAM IN ACCORDANCE WITH 757 S.R.M. 53-00-51-2.SDR MWEA020596Floorbeam · corrodedRIGHT LAV FLOOR BEAM AT FRAME STATION 817 HAS CORROSION AROUND 3 NUTPLATES APPROXIMATELY 24" RIGHT OF CENTER LINE. -- REMOVED DAMAGED AREA, FABRICATED, LOCATED AND DRILLED REPAIR ANGLE, INSTALLED REPAIR ANGLE,FILLER AND NUTPLATES.SDR GTIA021105Floorbeam · corrodedFTW - FOUND AFT CABIN STATION 1338 FLOORBEAM CORRODED RBL 20 INCHES. REMOVED DAMAGED AREA. FABRICATED ANGLE AND FILLER. INSTALLED ANGLE AND FILLER. (M)SDR SWIA200211394Floorbeam · crackedFS 280.0 RBL 9.0 FLOORBEAM ANGLES INBOARD AND OUTBOARD FOUND CRACKED. FOUND DURING C CHECK INSPECTION. NEW ANGLES FIT AND INSTALLED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-13 & 51-42-21. P/N: 601R31113-58SDR GTIA021126Floorbeam · corrodedAFT CABIN STA 1322 CORROSION ON FLOORBEAM. FABRICATED REPAIR ANGLE AND FILLER INSTALLED REPAIR PARTS.SDR MWEA020582Floorbeam · corrodedWEB ON STATION 200 FLOOR BEAM UNDER OUTBOARD LEFT VERTICAL SUPPORT IS CORRODED. -- REMOVED DAMAGED AREA, FABRICATED DOUBLER AND FILLER AND INSTALLED REPAIRED DOUBLER.SDR MWEA020583Floorbeam · corrodedFLOOR BEAM WEB STATION 1338 LEFT OUTBOARD ENDS HAS CORROSION. -- REMOVED DAMAGED SECTION, FABRICATED AND DRILLED UP FILLER AND DOUBLER, INSTALLED FILLER AND DOUBLER AND STAIR FITTING.SDR SWAA022209Floorbeam · crackedDURING SCHEDULED D CHECK, FOUND LONGITUDINAL FLOORBEAMS CRACKED (2 EA) BETWEEN BS 706 AND BS 711, WL 202 AT RBL 25 AND LBL 25. REPAIRED FLOORBEAMS PER BFG ER.SDR 2002UALA01483Floorbeam · corrodedSTATION 365 RBL10-RBL62 WL208 TOP OF FLOORBEAM HAS PAINT WORN OFF AND LT CORROSION IN SEVERAL SPOTS. MAJOR REPAIR ACCOMPLISHED. REPLACED UPPER T-CAP.SDR 2002UALA01558Floorbeam · corrodedAFT CABIN STATION 1016 FLOORBEAM UPPER CHORD LBL 7 TO 11 HAS EXCESSIVE MATERIAL LOSS DUE TO BLEND REMOVAL OF CORROSION. MAJOR REPAIR ACCOMPLISHED. REPAIR STRAP AND ANGLES INSTALLED.SDR UPS02839659Floorbeam · corrodedINSPECTION TYPE: C1, FLOORBEAM ATTACH ANGLE STA 1766, LBL 20 HAS CORROSION UNDER NUTPLATE ON VERTICAL LEG. REMOVED AND REPLACED ANGLE IAW DC8 SRM 51-1-21SDR UPS02439618Floorbeam · crackedINSPECTION TYPE:C BS 540 UPPER DECK FLOORBEAM UPPER HORIZONTAL FLANGE, 1 EA FASTENER HOLE CRACK FOUND AT RBL 42, 1/8 INCHES LONG RUNNING AFT. FLOORBEAM AT BS 540 RBL 42 REPAIRED AS PER SRM 53-10-07 FIG 21.SDR SIMA200228206Floorbeam · corrodedLEFT HAND FLOOR BEAM GUSSET IS CORRODED BETWEEN FRAME 65-68. INSTALLED SERVICEABLE GUSSET IAW SRM.SDR SIMA200227914Floorbeam · corrodedABI - DURNG AN IMBV INSPECTION, THE GALLEY AREA FORWARD DIGITAL WAS FOUND TO BE CORRODED. FABRICATED A SHIM AND TWO DOUBLERS. REPAIRED IAW EMB-145 SRM 145/1142, 53-21-10, AND STANDARD SRM PRACTICES. (M)SDR A6WA200230032Floorbeam · corrodedLAVATORY AREA FRAME 35 CORRODED BEYOND LIMITS. MAINTENANCE REMOVED FLOOR FRAME 35 AT LAVATORY AREA. FABRICATED REPLACEMENT FRAME AND INSTALLED REF HHC-02-348 REPAIR PROCEDURE AND DO328 SRM 51-10-01. (M)SDR A6WA200230035Floorbeam · crackedFLOOR BOARD SCREW HOLE ON FRAME 14 CRACKED AT CENTER AISLE 4H SIDE. MAINTENANCE REMOVED DAMAGED AREA. FABRICATED REPAIR PARTS AND INSTALLED RED DO328 SRM 53-00-50 AT FRAME 14. (M)SDR UPS02839664Floorbeam · corrodedINSPECTION TYPE: C1, FLOORBEAM AT FS 1723 BL16L HAS CORROSION UNDERNEATH LOWER FLANGE. REMOVED CORROSION IAW DC8 SRM 51-1-8 FOUND TO BE OUT OF LIMITS IAW D C8 SRM 53-2-0 REMOVED FLOORBEAM IAW DC8 SRM 51-1-20D FABBED FLOORBEAM IAW DC8 DAC DWG 5755032 ALODISDR 02FDEA00689Floorbeam · damagedCORROSION IN FASTENER HOLES ON FLOORBEAM LOWER FLANGE AT BS 1070, LBL 45 TO RBL 45. R&R FLOORBEAM PER DWG SR27-53-034, SRM 53-10-8.SDR AWXA200200970Web · crackedLCQ - MAJOR REPAIR - DURING C-06 CHECK A 1/2" CRACK WAS FOUND EMANATING FROM LIGHTNING HOLE ON CABIN FLOOR WEB AT LBL 24, BS 660 - 680. MAINTENANCE CUTOUT DAMAGED PORTION OF WEB, FABRICATED A REPAIR DOUBLER, AND INSTALLED REPAIR PART IAW B757-200 SRM 51-70-13,SDR GTIA021198Floorbeam · corrodedFTW - FOUND AFT CABIN STATION 1338 AT RBL 48 CORROSION ON STRUCTURE. REMOVED DAMAGED AREA AT FLOORBEAM. FABRICATED TWO ANGLES. INSTALLED TWO REPAIR ANGLES. (M)SDR GTIA021172Floorbeam · crackedFTW - AFT CABIN STATION 1322 FLOORBEAM CRACKED AT LBL 30 INCHES. REMOVED DAMAGED AREA. LOCATED AND DRILLED REPAIR ANGLE AND FILLERS. INSTALLED REPAIR ANGLE AND FILLERS. (M)SDR SIMA200228215Floorbeam · corrodedPREVIOUS REPAIR AT FRAME 20 ON LEFT FLOORBEAM IS CORRODED. REPAIRED IAW SRM.SDR SIMA200228213Floorbeam · corrodedRIGHT FLOORBEAM CORRODED AT FRAME 23. REPAIRED IAW SRM.SDR SIMA200227915Floorbeam · corrodedABI - DURING IMBV INSPECTION, MAINTENANCE FOUND CORROSION ON GALLEY CENTER FLOOR BEAM. CUT OUT SECTION GALLEY CENTER BEAM. FABRICATED A U-BEAM DOUBLER, FILLER. REPAIR DONE IAE EMB-145 SRM 145/1142, CHAPTER 51, REV 19, 51-40-02, ENB GST-1736/02-C ETN EM-53-0SDR GAIA02114STFloorbeam · corrodedDURING A LTC INSPECTION, IT WAS DISCOVERED THAT A FLOORBEAM AT BS 783, LBL 45.5 HAS CORROSION AT UPPER T-CAP. ACCOMPLISHED REPAIR IAW BOEING 727 SRM 53-10-8, FIGURE 3. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA0211STFloorbeam · damagedDURING A LTC INSPECTION, IT WAS DISCOVERED THAT THE FLOORBEAM AT BS 560, LBL 3 HAVE NUMEROUS HOLES THROUGH THE UPPER FLANGE AND RADIUS. ACCOMPLISHED A REPAIR IAW BOEING 727 SRM 51-40-4, FIGURE 1. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 02FDEA00678Floorbeam · corrodedCORROSION LWR CHORD BS 720 FLOORBEAM, WL 208, LBL 55 - RBL 55. R&R CHORD PER SR 27-53-034.SDR 200200283Floorbeam · crackedBS 320 MAIN DECK FLOORBEAM - CRACK IN WEB AT LBL 39 AND CRACK IN LOWER CHORD AT LBL 37.5. THE CRACKED WEB IS BEING REPAIRED BY LOCALLY TRIMMING AWAY THE CRACK, HFEC INSPECTING THE EXISTING FASTENER HOLES TO ENSURE A CRACK FREE CONDITION, AND INSTALLING A REPASDR UPS02239746Floorbeam · corrodedAREAS OF LIGHT SURFACE CORROSION ON UPPER CHORD OF FLOORBEAM BS 344 BETWEEN LBL 15 TO RBL 35. FLOORBEAM SECTION REPLACED IAW SRM 53-10-8 FIG 7 WITH REF TO BOEING DRG 65-16316.SDR UPS02239612Floorbeam · corrodedAREA OF LIGHT SURFACE CORROSION ON UPPER CHORD OF FLOORBEAM BS 312 AT LBL 4. CORROSION REMOVED IAW SRM 51-10-06 AND FOUND TO BE OUSIDE LIMITS. REPAIR THEN CARRIED OUT IAW SRM 53-10-8 FIG 9.SDR 2002UALA01467Floorbeam · corrodedCABIN FLOOR BEAM INBOARD CHORD EXFOLIATED AT STATION 681 LBL 62. MAJOR REPAIR ACCOMPLISHED. REPLACED CHORD ANGLE WITH NEW.SDR ZW0A0209704Floorbeam · corrodedDURING CHECK-C MAINT FOUND CORROSION IN FASTENER HOLES IN LONGITUDINAL FLOOR BEAM 11 INCHES INBD OF DOOR THRESHOLD FROM STA 1155 TO 1211. REPLACED FLOOR BEAM PER SRM 6-70-01.SDR 0203396638Seat Track · crackedDuring "L" check found corrosion on seat track at BS 492 LBL 35. Repaired per EA 66-192645.SDR 02FDEA00658Floorbeam · corrodedCORROSION LWR CHORD BS 1130, WL 200, LBL 55 - RBL 55. R&R CHORD PER EA 7-5310-62008.SDR 2002UALA01465Floorbeam · damagedCABIN FLOORBEAM, BODY STATION 947, RBL 48, UPPER SURFACE HAS EXCESSIVE MATERIAL REMOVED DURING REWORK. MAJOR REPAIR ACCOMPLISHED. FLOORBEAM FLANGE DOUBLER INSTALLED.SDR SWAA022182Floorbeam · corrodedDURING SCHEDULED D CHECK, FOUND FLOORBEAM CORRODED AT BS 986, WL 208 AND RBL 2. REPAIRED FLOORBEAM PER BFG ER.SDR SWAA022164Floorbeam · crackedDURING SCHEDULED D CHECK, FOUND LONGITUDINAL FLOORBEAM CRACKED AT BS 727A + 17, WL 208 AND LBL 25. REPAIRED FLOORBEAM PER BFG ER.SDR GTIA020986Floorbeam · corrodedFTW - FOUND CORROSION ON FLOORBEAM SUPPORT FS 1309 LBL 22 - RBL 22. REMOVED FLOOR SUPPORT. FABRICATED SUPPORT. INSTALLED SUPPORT. (M)SDR AWXA200200971Seat Track · corrodedLCQ - MAJOR REPAIR - DURING C-06 CHECK INTERGRANULAR CORROSION WAS FOUND ON R/H OUTBOARD SEAT TRACK BS 440. MAINTENANCE CUTOUT DAMAGED SECTION OF SEAT TRACK BS 440 TO BS 640. FABRICATED A NEW SECTION OF SEAT TRACK, AND INSTALLED REPAIR PART IAW B757-200 SRM 51SDR 2002UALA01450Floorbeam · corrodedCABIN FLOORBEAM UPPER CAP AFT FLANGE STATION 1640 HAS EXCESSIVE MATERIAL LOSS FROM CORROSION REMOVED AT RBL 51 TO RBL 52. MAJOR REPAIR ACCOMPLISHED. BEAM CAP STRAP REPAIR INSTALLED.SDR 200200276Floorbeam · damagedBS 340 UPPER DECK FLOOR BEAM - UPPER CHORD - OVERSIZED FASTENER HOLES AT LT FRAME ATTACHMENT. TWO FASTENER HOLES WERE OVERSIZED BEYOND THE LIMITS ALSO THE EDGE MARGIN IN THE FASTENER HOLE COMMON TO THE SUBJECT FLOORBEAM UPPER CHORD AND THE BS 340 FRAME INNER SDR 200200275Floorbeam · damagedBS 360 UPPER DECK FLOORBEAM EXISTING REPAIR STRAP, UPPER FWD FLANGE, LBL 41.7 - 65.2 DAMAGED. A FWD REPAIR ANGLE AND TWO AFT REPAIR ANGLES ALL INSTALLED ON AN UNDERSIDE OF THE BS 360 UPPER DECK FLOORBEAM CHORD.SDR 02FDEA00691Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER CHORD AT BS 344, LBL 60 - RBL 4, WL 208. R&R FLOORBEAM PER SRM 53-10-8 FIG 9.SDR CALA0200462Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 986.5, LBL 52 TO RBL 52. THE UPPER CAP WAS REMOVED AND A NEW "T" CHORD REPAIR WAS INSTALLED IAW ECRA 5310-03851.SDR 2002F00945Floorbeam · corrodedDURING SCHEDULED INSPECTION CABIN FLOOR SUPPORT, E&E BAY FLOORBEAM AT STATION 358 ABOVE NOSE WHEEL WELL DOGHOUSE FOUND WITH CORROSION AT FUSELAGE STATION 365 TO 365, WATERLINE 208 TO 208, BUTTLINE 48 RIGHT TO 48 RIGHT. MAINTENANCE REPAIRED AREA PER 757 S.R.M. SDR AWXA200200977Angle · crackedDURING C-06 CHECK A 1 INCH CRACK WAS FOUND ON UPPER FLOOR BEAM ANGLE IN THE FORWARD CARGO COMPARTMENT, BS 672. MAINTENANCE REMOVED THE CRACKED ANGLE FROM BS 660 TO BS 680. FABRICATED A NEW ANGLE, AND INSTALLED REPAIR PART IAW B757-200 SRM 51-40-02, FIG. 8, PG.SDR 2002UALA01452Floorbeam · crackedFLOORBEAM MIDCHORD CRACKED AT LBL 38, STA 246. MAJOR REPAIR ACCOMPLISHED. DOUBLER ANGLE INSTALLED.SDR AALA20021729Floorbeam · corrodedTUL - FOUND CORROSION AT FASTENER HOLE STATION 1338. INSTALLED DOUBLER AND FILLER SRM 53-05 FIG 20A. (M)SDR SIMA200226102Floorbeam · corrodedABI - DURING IMBV INSPECTION, THE FORWARD DIGITAL IN THE GALLEY WAS FOUND TO BE CORRODED. CUT OUT DAMAGED PORTION ON THE DIGITAL, 16.5 BY 21, AND FABRICATED TWO DOUBLERS, ONE SHIM. REPAIR DONE IAW EMB 145, SRM 145/1142, REV 18 SRM 53-21-10, AND STANDARD SRM SDR SWIA200211339Floorbeam · crackedFOUND FS 280.0 RBL 9.0 FLOORBEAM INBOARD ANGLE CRACKED. FOUND DURING C CHECK INSPECTION. FIT AND INSTALLED NEW ANGLE IAW CRJ SRM 51-40-11, 51-42-13, 51-42-21.
Back to JASC 5315