JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL73S971931Floor Beam · fatigueTHE STATION 520 FLOORBEAM WAS FOUND CRACKED AT THE FOLLOWING LOCATIONS: RBL 45, RBL 25, LBL 25 AND LBL 45. THE CRACKS ARE TYPICAL OF THOSE FOUND IN BACO S/B 737-53-1120 REV 1. THE FLOOR BEAM IS FABRICATED FROM 7075-T6511 EXTRUSION TO BAC 1518-338. NOTE: THISDR CALA9701406Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED STA 312 AND 344. THE CORRODED AREAS OF FLOORBEAM WERE CUT OUT. FLOORBEAM SECTIONS AND REPAIR ANGLES WERE FABRICATED AND INSTALLED IAW SRM 53-10-51.SDR CALA9701405Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 986.5 LEFT TO RIGHT. THE CORRODED SECTION WAS REMOVED AND A NEW SECTION OF FLOORBEAM WAS FABRICATED AND INSTALLED IAW ECRA 5310-03450.SDR CALA9701390Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 294, RBL 10. THE FLOORBEAM WAS REPAIRED IAW SRM 53-10-51.SDR B4MR97028Floorbeam · corrodedDURING ROUTINE CPCP CHECK INSPECTION, FOUND STA 328 FLOORBEAM AT LBL 3 HAS CORROSION. REPAIRED FLOORBEAM IAW B727 SRM 53-10-8 FIG 3. CORROSION TASK CARD NUMBER C53-224-01. NON-ROUTINE TASK CARD NUMBER 110399.SDR B4MR97013Floorbeam · corrodedDURING ROUTINE CPCP CHECK INSPECTION, FOUND STA 1030 TOP SIDE FLOORBEAM CORROSION WALL TO WALL. REPAIRED FLOORBEAM IAW AIA SKETCH NR AIA/E/2594 DATED 7-18-97, APPROVED BY FAA FORM 8110-3 DATED 7-21-97 PN=301 1/2HD 0.040IN AND FILLER 7075-T6. CORROSION TASK CSDR AALA974049Floor Beam · corrodedAFW - FOUND AND BLENDED OUT CORROSION ON THE UPPER SURFACE OF THE MAIN CABIN FLOOR BEAM. THE BLEND-OUTS EXCEED SRM 53-00-51 MAXIMUM LIMITS. ALODINED AND FILLED BLENDED AREAS. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 1/2 HARD STAINLESS STEELSDR 9718666628Floorbeam · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON MAIN DECK FLOORBEAM FROM FS 1269 TO 1300 AT LBL 33.9. REPAIRED PER EA 66-152329.SDR IXXA9800026Floorbeam · corrodedDURING ROUTINE D-CHECK INSPECTION, CORROSION WAS FOUND ON THE FLOORBEAM AT STATION 1520, BUTT LINE 45.O RIGHT. REPAIR ACCOMPLISHED BY REMOVAL OF DAMAGED AREA, FABRICATION AND INSTALLATION OF A REPAIR FILLER AND REPAIR ANGLE DOUBLERS IN ACCORDANCE WITH FAA PERSDR 97FDEA00684Floorbeam · crackedNR 0857 035 WHILE WORKING NR 0822 DISCOVERED BS 328 FLOORBEAM WEB TO BE CRACKED T LBL 30, WL 206. REPAIRED BS 328 FLOORBEAM WEB AT LBL 30, WL 206 AS PER FED-EX SRM 51-40-2.SDR 97FDEA00683Floorbeam · corrodedNR 0534 034 CORROSION (C53-224-06) AROUND FASTENERS IN THE CARGO TIE DOWN PUCK ON THE BOTTOM OF UPPER FLOORBEAM CHORD AT BS 620, RBL 62.5. REPAIRED UPPER FLOORBEAM CHORD AT BS 620, RBL 15 TO RBL 70 AS PER FED SRM 53-10-8.SDR 9718421157Floorbeam · crackedDURING M CHECK, FOUND CRACK ON FLOORBEAM UPPER CAP AT RBL 5, FS 791. REPAIRED PER EA 11-150759.SDR AALA974036Floorbeam · corrodedAFW - FLOORBEAM HAS CORROSION BEYOND SRM LIMITS AFTER BLENDING. FABRICATE .050 STRAP FROM 301 STAINLESS AND INSTALL WET WITH BMS 5095 PER ENGINEERING MRB 767-1476. (M)SDR AALA974035Floorbeam · corrodedAFW - FLOORBEAM HAS CORROSION BEYOND SRM LIMITS AFTER BLENDING. FABRICATED .050 STRAP FROM 301 STAINLESS AND INSTALLED WET WITH BMS 5095 PER ENGINEERING MRB 767-1475. (M)SDR UPS97224563Floorbeam · corrodedINSPECTION TYPE-C, WHILE ACCESSING FOR INTERIOR 81 CUSTOMER NR 740183 DISCOVERED FLOORBEAM UPPER CHORD TO BE CORRODED LBL 16 RBL 16 WL 208 BS 344. REMOVED CORROSION ON FLOORBEAM FOUND TO BE OUT OF LIMITS PER SRM 53-10-01. REPAIRED BEAM PER SRM 53-10-01.SDR SCNA97331Floorbeam · corrodedDURING HEAVY MAINTENANCE VISIT, FLOORBEAM UPPER FLANGE WAS FOUND CORRODED AT STATION 1050, RBL 42 TO 59. CUT OUT DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR ANGLES PER B727 SRM 51-30-2 AND 53-10-8.SDR CKSA97542Floorbeam · corrodedDURING ROUTINE C-CHECK INSPECTION, FOUND CORROSION ON LOWER SURFACE OF UPPER CARGO COMP, FLOORBEAM FS 1665. REMOVED CORROSION IAW L1011 SRM 51-21-01, FOUND TO BE OUT OF LIMITS. REPAIRED FLOORBEAM FS 1665 LWR FLANGE IAW L1011 SRM 53-21-00 FIG 804. C-CHECK WOSDR SIMA972635Floorbeam · corrodedSAW - DURING D-CHECK INSPECTION MAINTENANCE DISCOVERED FLOORBEAM 36 CORRODED OUT OF LIMITS. MAINTENANCE REMOVED, INSTALLED FLOORBEAM IAW SRM 51-25-01 AND 51-25-02. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR SIMA972634Floorbeam · corrodedSAW - DURING D-CHECK INSPECTION, MAINTENANCE DISCOVERED FLOORBEAMS 38 AND 39 CORRODED OUT OF LIMITS. MAINTENANCE REMOVED AND INSTALLED FLOORBEAMS IAW SRM 51-25-01 AND 51-25-02. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR RRXA97274Floorbeam · corrosionPERFORMED FOLLOW-UP INSPECTION OF FLOORBEAM AT STA 1360 AND BL 58RT, FOUND CORROSION DAMAGE BEYOND LIMITATIONS IAW DC-8 SRM. REMOVED CORROSION DAMAGE, FABRICATED AND INSTALLED REPAIR FILLERS AND ANGLES IAW FAA APPROVED DER COTNEY ENGINEERING SKETCH D19-R01 ANSDR AALA974042Floor Beam · corrodedAFW - FOUND AND BLENDED CORROSION ON THE UPPER SURFACE OF THE UPPER FLANGE OF THE FLOOR BEAM. REFINISHED BLENDED AREA PER SRM 53-00-51. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-1485. CYCLES: 4,256. (X)SDR 97ZZZM1074Floorbeam · corrodedSAW - DURING D-CHECK INSPECTION, MAINTENANCE DISCOVERED FLOORBEAMS 38 AND 39 CORRODED OUT OF LIMITS. MAINTENANCE REMOVED AND INSTALLED FLOORBEAMS IAW SRM 51-25-01 AND 51-25-02. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 97FDEA00673Floorbeam · corrodedUPPER LOBE CORROSION ON FLOORBEAM TOP AND BOTTOM OF UPPER FLANGE BS 480, RBL 12 TO 16. INSTALLED DOUBLER PER AARD 53-10-07-02.SDR DL76S971922Floorbeam · crackedTHE FUSELAGE SEAT TRACKS LOCATED AT RBL 33, LBL 54, AND RBL 54 WERE FOUND CRACKED IN THE VERTICAL WEB OF THE UPPER CHORD AT APPROXIMATELY FS 786 AS DESCRIBED IN BOEING SB 767-57-0029. THE VERTICAL WEB IS M/F FROM .063 THK 2024-T3 AL MATERIAL. IN ADDITION, TOSDR USAA970284Floorbeam · corrosionCLT - DURING Q-3 VISUAL INSPECTION, FOUND CORRODED FLOORBEAM SURFACE AROUND FASTENERS AT STATION 967 18 RBL, CORROSION TASK NR C53-107-02. REPLACED UPPER 'T' CAP FLOORBEAM 0 RBL TO 35 RBL PER TYPICAL REPAIR DOCUMENT 53-10-05. (M)SDR USAA970283Floorbeam · corrosionCLT - DURING Q-3 VISUAL INSPECTION, FOUND FLOORBEAM CORRODED IN 6 AREAS BS 986.5 'T' CAP. CORROSION TASK NR C53-107-02. REPLACED UPPER 'T' CAP FLOORBEAM L TO R WITH SPLICE AT BL 0 PER TYPICAL REPAIR DOCUMENT 53-10-05. (M)SDR SIMA972602Floorbeam · corrodedDURING CPCP-4 INSPECTION, MAINTENANCE DISCOVERED FLOORBEAM 17 CORRODED OUT OF LIMITS. MAINTENANCE REPAIRED FLOORBEAM IAW SRM 53-00-00. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR AALA971811Floor Beam · corrodedTUL - WEB BELOW FLOOR BEAM HAD INTERGRANULAR CORROSION FORWARD AND AFT SIDES, RBL 30 TO RBL 61. REPAIRED IAW BOEING 727 SRM 51-40-02, FIG 1, SHEET 3, PAGE 3. TST: 70,323.2 HOURS. CYCLES, 48,502. (X)SDR AALA971804Floor Beam · corrodedTUL - FLOOR BEAM TOP CORROSION AT BS 380 FROM RBL 24 TO RBL 61. REPAIRED IAW BOEING SRM 53-10-8, PAGE 9A. TST: 70,323.2 HOURS. CYCLES, 48,502. 7(X)SDR UPS97424497Floorbeam · corrodedINSPECTION TYPE-C, MAIN CABIN A-ZONE BS 400, LBL 40 THRU RBL 40, WL 199.8 FLOORBEAM HEAVILY CORRODED AT UPPER AND LOWER SIDE. FLOORBEAM AT BS 400 LBL 40 THRU RBL 40 OUT OF LIMITS ACC SRM 53-10-01. REPAIRED FLOORBEAM ACC EFN 747-53-0844 KLM DFX 97-231.SDR AWXA9700582Floorbeam · corrodedDURING SCHEDULED C-12 INSPECTION, FOUND CORROSION (C53-107-02 PART 2 OF 2) ON FLOORBEAM STA 328, RBL 33 AND RBL 41, WL 208. FABRICATED REPAIR PARTS AND INSTALLED TOP CHORD AT BS 328, RBL 31 TO RBL 65, WL 208 PER SRM 53-10-51.SDR AWXA9700578Floorbeam · corrodedDURING SCHEDULED C-12 INSPECTION, FOUND CORROSION (C53-107-02 PART 2 OF 2) ON FLOORBEAM STA 312, LBL 12 AND RBL 8, WL 208. REPAIRED TOP CHORD FROM BS 312, RBL 23 - LBL 36 PER SRM 53-10-51.SDR USAA970281Floor Beam · corrosionCLT - DURING Q-4 VISUAL INSPECTION FOUND A 2 INCH AREA OF CORROSION AT STA 967 FLOOR BEAM AT RBBL 18.0. CORROSION TASK NR C53-107-02. CUT OUT CORROSION, REPAIRED DOUBLER AND FILLER PER REPAIR DOCUMENT SRM 53-00-51. (X)SDR USAA970280Floor Beam · corrosionCLT - DURING Q-4 VISUAL INSPECTION, FOUND A .500 INCH AREA OF CORROSION STA 967 FLOOR BEAM AT LBBL 18.0. CORROSION TASK NR C53-107-02. REMOVED CORROSION, FABRICATED FILLER AND DOUBLERS PER REPAIR DOCUMENT SRM 53-00-51. (X)SDR USAA970279Floor Beam · corrosionCLT - DURING Q-4 VISUAL INSPECTION, FOUND CORROSION AROUND CLIP-NUT HOLES ON THE FLOOR BEAM, STA 987, BL ZERO TO RBBL 45.0. CORROSION TASK NR C53-107-02. REMOVED AND REPLACED T-CAP. REPAIRED ENTIRE LENGTH PER REPAIR DOCUMENT SRM 53-60-51. (X)SDR USAA970278Floor Beam · corrosionCLT - DURING VISUAL INSPECTION FOUND CORROSION AROUND CLIP-NUT HOLES ON FLOOR BEAM, STA 987, FLOOR BEAM BL ZERO TO LBBL 45.0. CORROSION TASK NR C53-107-02. REPAIRED ENTIRE T-CAP PER SRM 53-60-51. (X)SDR DL73E971863Floorbeam · crackedTHE FS 246 FLOORBEAM WEB WAS FOUND WITH A CRACK APPROXIMATELY 3.75 LONG AT RBL 20. THE RESULTING CUTOUT IS 1.0 BY 3.75. THE SUBJECT WEB IS MANUFACTURED FROM .025 CLAD 7075-T6. THE STIFFENER AT RBL 20 WAS CRACKED AS WELL. THE STIFFENER (P/N 141T5814-88) IS SDR ASAA9740060Floor Beam · corrodedSEA - DURING STRUCTURAL INSPECTION, THE FLOOR BEAM UPPER FLANGE AT BS 947 BETWEEN RBL 4 AND LBL 4 WAS FOUND CORRODED. REPAIRED PER EA 5310-01551. TT: 16,604 HOURS. TC: 8,816. (X)SDR 9718369936Floorbeam · crackedDURING M CHECK, FOUND CRACK IN FLOORBEAM AT FS 237 UNDER AFT SIDE OF FLOOR PANEL NR 23. REPAIRED PER EA 99-151684.SDR AWXA9700577Floorbeam · corrodedDURING SCHEDULED C-12 INSPECTION, FOUND CORROSION ON FLOORBEAM STA 294, RBL 39, WL 208. FABRICATED AND INSTALLED REPAIR STRAP PER SRM 53-10-51 AT BS 299, RBL 39, WL 208.SDR CALA9701382Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT JOINT TO BULKHEAD TO T-CAP ANGLE, STA 2007(J LAV). THE FLOORBEAM WAS REPAIRED IAW SRM 53-70-00.SDR SIMA972551Floor Beam · corrodedSAW - DURING CPCP-4/MBVI INSPECTION, MAINTENANCE DISCOVERED FLOOR BEAMS 36 AND 39 CORRODED OUT OF LIMITS IAW 53-11-00, FIGURE 301. MAINTENANCE REPAIRED FLOOR BEAM 36 IAW SRM 53-00-00, FIGURE 438. MAINTENANCE REMOVED AND INSTALLED FLOOR BEAM 39 IAW SRM 51-25-SDR DL73K971886Floorbeam · crackedTHE STATION 520 FLOORBEAM HAS DAMAGE IN THE TYPICAL LOCATIONS AT BOTH LBL 24.75 AND LBL 45.5. THE BEAMS ARE M/F FROM BAC1518-338, 7075-T6511 EXTRUSION. SUBMITTER STATES, THIS IS A GROUP 3 A/C PER S/B 737-53-1120, REV 1. REPAIRED PER ERA 330701-14 REV B.SDR 97ZZZX4231Floorbeam · corrodedSAW - DURING CPCP-4/MBVI INSPECTION, MAINTENANCE DISCOVERED FLOOR BEAMS 36 AND 39 CORRODED OUT OF LIMITS IAW 53-11-00, FIGURE 301. MAINTENANCE REPAIRED FLOOR BEAM 36 IAW SRM 53-00-00, FIGURE 438. MAINTENANCE REMOVED AND INSTALLED FLOOR BEAM 39 IAW SRM 51-25-SDR AWXA9700574Floorbeam · corrodedDURING SCHEDULED C-11 INSPECTION, FOUND CORROSION ON FLOORBEAM BS 987, RBL 20.5, WL 208. FABRICATED REPAIR PARTS AND INSTALLED PARTS ON BS 987 BEAM RBL 20.5, WL 208 PER SRM 53-00-51.SDR DHL9772723CFloorbeam · crackedAT C-CHECK, MAIN CABIN CENTER SECTION FLOORBEAM CRACK THROUGH HOLE BS 825 LBL 51. REMOVED AND REPLACED WEB AT BS 825 LBL 45 TO LBL 70, 25 BY 12 PER SRM 51-30-2 AND SRM 53-10-2.SDR DHL9772722CFloorbeam · crackedAT C-CHECK, MAIN CABIN CENTER SECTION FLOORBEAM CRACKED AT BOTH THROUGH HOLES BS 804 LBL 51 AND LBL 55. REMOVED AND REPLACED WEB PER SRM 51-30-2 AND 53-10-2, 24.25 BY 9.SDR 97ZZZX4358Floor Beam · crackedFLOOR BEAM CRACKED, STA 685, STR 62R. REPAIRED PER DALFORT AVIATION XEA NR X2-53-180 REV 1 DATED 7-18-97. APPROVAL DATA: FAA FORM 8110-3 DATED 7-29-97.SDR W8PA971572Floorbeam · corrodedPAE- CORROSION ON FLOORBEAM BS 328, RBL 14 TO 51, WL 208. CORROSION REMOVED, OUT OF LIMITS, REPLACED UPPER CHORD 328 FLOORBEAM.SDR W8PA971571Floorbeam · corrodedPAE- CORROSION ON FLOORBEAM BS 312, LBL 27, RBL 12, WL 208. REMOVED FLOORBEAM UPPER CHORD, OUT OF LIMITS, CUT OUT DAMAGE, FABRICATED AND INSTALLED PARTS.
Back to JASC 5315