SDR 9515889855Floorbeam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FLOORBEAM CHORD FS 1136 AT LBL 19. REPAIRED CHORD (P/N 2912578), PER EA 98-102585.SDR 95FDEA01435Floor Beam · corrosionCORROSION (72C235-02) AND BARE METAL ON TOP CHORD AND WEB OF THE BS 600 FLOOR BEAM RBL 2-55 AND LBL 2-48, WL 202-208. REMOVED CORROSION AT BS 600, RBL 2-55 AND LBL 2-43, WL 202-208, RBL 11 - 41 WERE FOUND TO BE OUT OF LIMITS. ORIGINAL MATERIAL THICKNESS WAS SDR 95FDEA01434Floor Beam · corrodedCORROSION ON FLOOR BEAM STA 328, WL 208, LBL 18 - 45. REMOVED CORROSION AND TREATED BS 328, WL 208, LBL 45. FOUND CORROSION AT BS 328, WL 208, LBL 18 OUT OF LIMITS. REMOVED DAMAGED AREA AND INSTALLED REPAIR. ALL PER FEDEX SRM 53-10-8, 53-10-1, 53-10-2.SDR 95FDEA01431Floor Beam · corrodedCORROSION OF FLOOR TRACK AT LBL 45 AT BS 360, 400-420 AND 380. REMOVED SECTION OF FLOOR BEAM STATION 360 - 420 AND INSTALLED NEW FLOOR TRACK FROM STA 360-420 PER SRM 51-10-5.SDR 95FDEA01424Floor Beam · corrosionCORROSION (72C235-02), ON TOP CHORD AND WEB OF BS 720 FLOORBEAM, RBL 13 TO 22, 47.5 TO 55, WL 206 TO 208.SDR AALA951712Floor Beam · corrodedAFW - FLOOR BEAM HAD CORROSION BLENDED BEYOND SRM LIMITS, STATION 1640 RBL 54, LBL 54, PER MRB 757-607. (M)SDR AALA951710Floor Beam · corrodedAFW - FLOOR BEAM HAD CORROSION BLENDED BEYOND SRM LIMITS AT STATION 324 RBL 60, PER MRB 757-608. (M)SDR AALA951707Floor Beam · corrodedAFW - FLOOR BEAM HAD CORROSION BLENDED BEYOND SRM LIMITS AT STATION 365, LBL 10, RBL 14 AND RBL 61, PER MRB 757-610. (M)SDR 96ZZZX1850Floor Beam · corrodedDURING C- AND D-CHECKS, FOUND FLOOR BEAM CORRODED, STA 965. REPAIRED IAW DC9 SRM CH 53. AIRCRAFT TT: 51,653. AIRCRAFT TC: 57,610.SDR 95FDEA01481Floor Beam · corrodedSTA 640, RBL 5 UPPER FLANGE OF FLOOR BEAM HAS EXFOLIATION CORROSION PILLOWED AND BLOWN OUT - REMOVED CORROSION AND INSTALLED DOUBLER REPAIR WITH 7075-T6 EXTRUSIONS AND A 15-5 STAINLESS STEEL STRAP, CAD PLOTED AND HEAT TREATED TO 180-200 RSI, TREATED AND PRIMEDSDR 95FDEA01480Floor Beam · corrodedCORROSION BOTTOM OF FLOOR BEAM JUST I/B OF RBL 25 SEAT TRACK STA 480. REMOVED PORTION OF CORRODED BEAM - FABRICATED AND INSTALLED DOUBLER PER 53-10-8 FIG 5 OF SRM.SDR 95FDEA01460Floorbeam · corrodedUPPER LOBE FLOOR, CORROSION ON UNDERSIDE OF FLOORBEAM LT STA 480 BETWEEN BL 0 AND LBL 24. CORROSION REMOVAL WAS BEYOND LIMITS. INSTALLED REPAIR IAW 53-10-8 FIG 5 AND 51-40-2.SDR 95FDEA01420Floor Beam · corrodedCORROSION AROUND FLOOR PANEL FASTENER HOLES AT FLOORBEAM STA 344 WL 208 RBL 19 LBL 55. CORROSION FOUND TO BE OUT OF LIMITS PER FEDEX SRM 53-10-02. REMOVED AND REPLACED 344 BEAM UPPER CHORD FROM SKIN TO SKIN PER FEDEX DRAWING NR SR 8753-007.SDR 95FDEA01478Floor Beam · corrodedUPPER LOBE FLOOR STA 480 LT CORROSION ON UNDERSIDE OF FLOOR BEAM BETWEEN LBL 24 AND LBL 45 AROUND FASTENER HOLES. REMOVED CORROSION NR 7 ABOVE LOCATION PER SRM 51-10-06. CORROSION REMOVED BEYOND LIMITS, REPAIRED CORRODED FLOOR BEAM PER 53-10-8 FIG 5.SDR 95FDEA01430Floor Beam · corrodedHEAVY CORROSION AT F/B SCREW HOLES STA 400, LBL 35 ON FLOOR BEAM TOP SIDE. REMOVED CORROSION BY CUTTING OUT DAMAGED AREA PER SRM 53-10-8. INSTALLED FLOOR BEAM REPAIR PER SRM 53-10-8, PG 45 - 48.SDR ABXA9500923Floor Beam · corrodedDURING 826AX MOD, FOUND FLOOR BEAM SUPPORT LEG AT FS 180 CORRODED. REPAIRED FLOOR BEAM SUPPORT AT FS 180 IAW ABX REA D853-12608MR.SDR 95ZZZX5861Floor Beam · corrodedCORROSION OF FLOOR BEAM CHORD ANGLE. LOCATED JUST AFT OF NR 1 DOOR OPENING. AREA SUBJECT TO WATER ENTRAPMENT. SUBMITTER SUGGESTS IF FLOOR IN DOOR OPENING HAS LARGE AMOUNT OF WATER PRESENT, INSPECT AND RE-SEAL AREA.SDR USAA951010Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION EXCEEDING LIMITS AROUND HOLE, BS 958 RBL 7.5. FABRICATED NEW INTERCOSTAL FROM BAC1506-437075-T6 AND INSTALLED. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR HALA95125Floor Beam · corrodedHNL - IN C-CHECK, FOUND HEAVY CORROSION ON MID SECTION OF E/E COMPARTMENT AFT FLOOR BEAM, L-1 HEAVY LOCAL. REMOVED DAMAGED SECTION. INSTALLED FILLER AND REPAIR ANGLES PER SRM 53-01. (M)SDR AWXA9500658Floor Beam · corrodedPHX - DURING SCHEDULED C13 INSPECTION, FOUND AFT CABIN FLOOR BEAM AT STATION 947 RBL 5 TO RBL 6 CORRODED BEYOND LIMITS. REPAIRED BEAM PER SRM 53-10-9. (M)SDR AWXA9500652Floor Beam · corrodedPHX - DURING SCHEDULED C13 INSPECTION, FOUND AFT GALLEY FLOOR BEAM TOP CAP AT STATION 986.5 RBL 17 CORRODED BEYOND LIMITS. REMOVED AND REPLACED T-CAP PER SRM 53-10-09. (M)SDR 95FDEA01491Floor Beam · corrodedMAIN CARGO INTERIOR, CORROSION ON TOP OF STA 344 FLOOR BEAM UPPER CHORD, BETWEEN RBL 2 - 14. REMOVED CORROSION, INSTALLED REPLACEMENT CHORD AND SPLICE ANGLES PER STANDARD REPAIR DRAWING MANUAL SR 27-53-007.SDR 95FDEA01432Floor Beam · corrodedMAIN CARGO INTERIOR, CORROSION ON TOP OF STA 344 FLOOR BEAM UPPER CHORD BETWEEN RBL 2 - 14. REMOVED CORROSION, INSTALLED REPLACEMENT CHORD AND SPLICE ANGLES PER STANDARD REPAIR DRAWING MANUAL SR 277-53-007.SDR 95FDEA01401Floorbeam · corrodedCORROSION (72C235-02), AROUND FASTENER HOLE ON BS 660 FLOORBEAM RBL 19 WL 208. REMOVED DAMAGE AT BS 660 FLOORBEAM RBL 19 WL 208 AND INSTALLED REPAIR PER FEDEX SRM 53-10-08 FIG 8. REMOVED .046 MATERIAL FROM ORIGINAL .125 THICKNESS FLANGE, FOUND TO BE OUT OF SDR UPS204486Floor Beam · corrodedWHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION ON THE FLOOR BEAM AROUND THE NUTPLATE HOLE FORWARD LOWER SIDE OF THE UPPER CHORD ON THE FLOOR BEAM AT STATION 500, LBL 55 - 57 AND WL 208. MAINTENANCE REPAIRED THE FLOOR BEAM IAW SRM 53-10-8.SDR SWAA950647Floorbeams · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947 WL 208 RBL 10 TO 16, BS 294 LBL 15 RBL 9 WL 208 AND BS 360 RBL 14 WL 208. REPAIRED PER BOEING STRUCTURAL REPAIR MANUAL.SDR 95FDEA01414Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM AT BS 1800 LBL 85 TO 90 UPPER CHORD HAD CORROSION, CIRCUMSTANCES UNK. REMOVED DAMAGED AREA, FABRICATED REPAIR SPLICE IAW B747 SRM 51-40-04, INSTALLED FLOORBEAM T-CHORD IAW B747 SRM 51-40-4 AND INSTALLED REPAIR SPLICE IAW B747 SRM 51-SDR 95FDEA01413Floorbeam · corrodedMAIN CARGO DECK FLOOR BEAM AT BS 1720 BL 0 - RBL 119 UPPER CHORD HAD CORROSION. CIRCUMSTANCES UNK. R/R FLOOR BEAM IAW B747 SRM 51-10-01.SDR 95FDEA01412Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM AT BS 1740 LBL 60 HAD CORROSION, CIRCUMSTANCES UNK. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-10-01.SDR 95FDEA01411Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM AT BS 1660 BL 0 RBL 119, UPPER AND LOWER SURFACES HAD CORROSION, CIRCUMSTANCES UNK. REMOVED AND REPLACED FLOORBEAM IAW B747 SRM 51-10-1.SDR 95FDEA01410Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM AT BS 1640 LBL 34 TO 76 UPPER CHORD HAD CORROSION, CIRCUMSTANCES UNK. REMOVED AND REPLACED SECTION OF FLOORBEAM IAW B747 SRM 51-40-04.SDR 95FDEA01409Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM AT BS 1800 RBL 76 TO 119, UPPER CHORD HAD CORROSION, CIRCUMSTANCES UNK. REMOVED AND REPLACED SECTION OF FLOORBEAM UPPER CHORD AND REPAIRED IAW B747 SRM 51-40-04.SDR 95FDEA01408Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM AT BS 1720 RBL 75 HAD CORROSION, CIRCUMSTANCES UNK. REMOVED AND REPLACED FLOORBEAM IAW B747 SRM 53-10-7.SDR 95FDEA01407Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM AT BS 1640 RBL 34 TO 76, UPPER AND LOWER SURFACES HAD CORROSION, CIRCUMSTANCES UNK. REMOVED AND REPLACED FLOORBEAM IAW B747 SRM 51-10-1.SDR 95FDEA01398Floor Beam · corrodedON NR 0234, CORROSION ON FLOOR BEAM IN MAIN CARGO STA 420 RBL 20. CORROSION REMOVED BEYOND LIMITS. CUT OUT AREA AND INSTALLED .090 INCH DOUBLERS AND FILLER PER SRM 53-11-8, FIG 8.SDR 95FDEA01395Floor Beam · corrodedCORROSION ON TOP OF UPPER LOBE FLOOR BEAM STA 344, RBL 2-6.SDR USAA951088Floor Beam · corrodedPIT - DURING Q-1 CHECK INSPECTION, FOUND LEVEL 1 CORROSION PREVIOUSLY REWORKED STATION 1307 FLOOR BEAM, RIGHT SIDE. MANUFACTURED NEW FLOOR SUPPORT, L ANGLES AND SUPPORTS. SPLICED IN NEW SECTION PER USAIR TYPICAL REPAIR 53-10-14 AND USAIR EA NR 31216. (M)SDR 95FDEA01373Floorbeam · corrodedCORROSION ON FLOORBEAM BS 312 LBL 4, 19, 45 WL 208 AROUND NUTPLATE HOLES. REPAIRED CORRODED AREA ON FLOORBEAM BS 312 LBL 19 WL 208 AROUND NUTPLATE HOLES PER FEDEX 53-10-8 FIG 7. REMOVED CORROSION ON BS 312 FLOORBEAM LBL 4 AND 45 WL 208, FOUND TO BE WITHIN LISDR DL72L953725Floorbeam · corrodedFOUND ON CV2 CHECK, CORROSION ON FLOORBEAM STA 1050 AT SCREW HOLES TOP AND BOTTOM LBL 60 TO LBL 12. REPAIRED PER M/M 53-20-11.SDR DL73S953992Floorbeam · crackedDURING CORROSION VISIT, FOUND THE BL 0 FLOORBEAM OF THE WING CENTER SECTION CRACKED AT FS 662. THE UPPER CAP OF THE BEAM IS COMPLETELY CRACKED THROUGH, INCLUDING TWO FASTENER HOLES. ACCOMPLISHED REPAIRS PER SB 737-57-1210.SDR 95FDEA01369Floorbeam · corrodedCORROSION ON MAIN CABIN FLOORBEAM STA 400 AT LBL 35.SDR UPS804419Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE FOUND FS 850 LBL 50 FLOORBEAM HAD CORROSION IN FWD LWR CORNER, AFTER FASTENERS CORROSION AND DAMAGED CHORD WERE REMOVED. WEB WAS FOUND IN LIMITS AND PROTECTIVE TREATED CHORD WAS SUBMITTED TO ENG. REMOVED DAMAGED AREA, FABBEDSDR UPS404425Floorbeam · corrodedWHILE IN AMSTERDAM FOR C-CHECK, MAINTENANCE FOUND INTERNAL BODY STA 2200 RBL 33 TO RBL 75 FLOORBEAM BADLY CORRODED. REWORKED CORROSION ACC SRM 51-10-01 AND REPLACED UPPER CHORD ACC SRM 53-10-07.SDR CAL950850Floor Beam · crackedHOU - INSPECTION FOUND A 2 INCH CRACK IN FLOOR BEAM UPPER FLANGE AT STATION 520, RBL 24.75. THE FLOOR BEAM UPPER FLANGE WAS REPAIRED IAW SRM 5320-01208. (M)SDR AALA951675Floor Beam · corrodedCORROSION FOUND ON FLOOR BEAM. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 HALF HARD STAINLESS STEEL. APPROVED BY ENGINEERING PER MRB767-1009. (M)SDR 95FDEA01361Floorbeam · corrodedCORROSION (72C235-02), ON BEAM BS 480 LBL 12 TO 36 WL 208. REPAIRED UPPER CHORD OF FLOORBEAM BS 480 RBL 15 LBL 36 PER FEDEX SRM 53-10-8, ALODINED, PRIMERED AND PAINTED. FOUND CORROSION OUT OF LIMITS PER FEDEX SRM 53-10-1.SDR USAA951067Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .5 INCH DIAMETER AREA OF CORROSION STATION 294.5 FLOOR BEAM UPPER CHORD AT RBL 4. INSTALLED REPAIR ANGLES PER SRM 53-10-51 FIG 206. REPAIRED PER SRM 53-10-51, FIG 206. CORROSION TASK NR C53-107-02, CORROSION LSDR UPS804401Floor Beam · corrodedWHILE IN DALFORT FOR C-CHECK, MAINTENANCE FOUND MODERATE CORROSION DAMAGE ON AFT SIDE OF FLOORBEAM AND FITTING, FS 1620 LT CUSP. REPLACED FITTING PER SRM 51-1-20D.SDR UPS404407Floorbeam · corrodedWHILE IN AMSTERDAM FOR C-CHECK, MAINTENANCE FOUND FLOORBEAM CORRODED RBL 33.99, STA 1580 FLOORBEAM OUT OF LIMITS ACC SRM 53-10-01. REPAIRED FLOORBEAM IAW SRM 53-10-07, FIG 12, AT 33.99 RBL STA 1580.SDR UPS404406Floorbeam · crackedWHILE IN AMSTERDAM FOR C-CHECK, MAINTENANCE FOUND BS 460 STR 13A RT FLOORBEAM HAS CRACK ON FORWARD FACE OF WEB 1 INCH LONG AT THE UPPER SIDE OF THE WEB. CRACK OUT OF LIMITS ACC SRM 53-10-01. REPAIRED FLOORBEAM WEB ACC SRM 53-10-07, FIG 11, AT BS 460, STR 13A
Back to JASC 5315