JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021090300911Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 500B+6; LBL 24; WL 156 (MARKED) ; / REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 500B+6; LBL 24; WL 156. P/N 143A7501-80; IN AREA 0.8' X 0.6' X 0.020' DEEP; ORIGINAL THICKNESS 0.040' FOUND TO BSDR SWAA2021090300906Shield · corrodedCORROSION ON FCB R/H FWD SHIELD; BS 420+16; RBL 24; WL 156 (MARKED) ; / [01] EVALUATED FCB FWD SHIELD BS420-440 RBL 24 WL 156 AND NO FOUND ALLOWABLE DAMAGE ON SRM 53-30-15-1A-1; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9C; [02] REMOVED FCB FWDSDR SWAA2021090300888Shield · corrodedCORROSION ON FCB R/H AFT SHIELD; BS 500+14; RBL 24; WL 156 (MARKED) ; / [01] DAMAGE FOUND ON FCB SHIELD BS 500+14; RBL 24; WL 156. P/N 143A8126-19 FOUND TO BE OUT OF LIMITS ON SRM; PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9.C.; [02] REMOSDR SWAA2021090300885Support · corrodedCORROSION ON R/H FLOOR-TO-SIDEWALL SUPPORT; BS 500C+10; RBL 24; WL 156 (MARKED) ; / REMOVED CORRISION FROM FCB FWD R/H FLOOR-TO-SIDEWALL SUPPORT; BS 500C+10; RBL 24; WL 156. P/N 143A7501-4; IN AREA 0.8' X 0.6' X 0.019' DEEP; ORIGINAL THICKNESS 0.04' FOUND TO BSDR SWAA2021090300907Support · corrodedCORROSION ON FCB FWD R/H FLOOR-TO-SIDEWALL SUPPORT; BS 400+2; RBL 24; WL 156 (MARKED) ; / REMOVED CORRISION FROM FCB FWD R/H FLOOR-TO-SIDEWALL SUPPORT; BS 400+2; RBL 24; WL 156. P/N 143A7501-2; IN AREA 0.3' X 0.4' X 0.019' DEEP; ORIGINAL THICKNESS 0.04' FOUND SDR SWAA2021090300893Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 420+9; LBL 25; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORT;SDR SWAA2021090300908Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 460+12; LBL 24; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORTSDR SWAA2021090300896Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 500A+14; LBL 25; WL 156 (MARKED) ; / [01] REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 500A+14; LBL 25; WL 156. P/N 143A7501-80; IN AREA 0.8' X 0.7' X 0.016' DEEP; ORIGINAL THICKNESS 0.040' FOUSDR SWAA2021090300884Support · corrodedCORROSION ON R/H FLOOR-TO-SIDEWALL SUPPORT; BS 500A+2; RBL 24; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB R/H FLOOR-TO-SIDEWALL SUPPORT; BSSDR SWAA2021090300910Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 500+18; LBL 25; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORTSDR SWAA2021090300909Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 500+13; LBL 24; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORTSDR SWAA2021090300895Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 460+6; LBL 24; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORT;SDR SWAA2021090300894Support · corrodedCORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 460; LBL 24; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB FWD L/H FLOOR-TO-SIDEWALL SUPPORSDR SWAA2021090300892Support · corrodedCORROSION ON FCB FWD R/H FLOOR-TO-SIDEWALL SUPPORT; BS 400+19; RBL 23; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLAWABLE DAMAGE.; [02] REMOVED CORRISION FROM FCB FWD R/H FLOOR-TO-SIDEWALSDR SWAA2021090300891Support · corrodedCORROSION ON FCB FWD R/H FLOOR-TO-SIDEWALL SUPPORT; BS 400+14; RBL 24; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB FWD R/H FLOOR-TO-SIDEWALLSDR REXA2021090200656Angle · corroded"FWD WING TO FUSELAGE FAIRING SUPPORT INTERCOSTAL BETWEEN F.S. 661.00+62 AND F.S. 661.00+90 BELOW THE FWD KEEL BEAM HAS CORROSION IN FASTENER HOLES. R & R UNSERVICEABLE INTERCOSTAL WITH A SERVICEABLE INTERCOSTAL BETWEEN FS 661+62 AND 661+90 IAW CRJ900 SRM 51-SDR HNAA2021083100415Floor Support · corrodedRH #6 FLOOR SILL HAS MULTIPLE AREAS OF CORROSION. R & R R/H #6 FLOOR SILL IAW SRM 51-40-02.SDR HNAA2021083100414Floor Support · corrodedL/H #7 OTBD FLOOR SILL IS CORRODED. REMOVED AND INSTALLED NEW L/H #7 OTBD FLOOR SILL IAW SRM 51-40-02SDR HNAA2021083100413Gusset · corrodedCENTER #6 OMEGA BEAM GUSSET IS CORRODED. REMOVED AND INSTALLED NEW CABIN CENTER OMEGA BEAM GUSSET #6 IAW SRM 51-40-02SDR HNAA2021083100412Gusset · corrodedL/H #7 OMEGA BEAM GUSSET IS CORRODED. R & R LH #7 CABIN OMEGA BEAM GUSSET IAW SRM 51-40-02.SDR HNAA2021083100411Gusset · corrodedR/H BEAM GUSSET IS CORRODED BETWEEN FRAMES 59-61. REMOVED AND REPLACED R/H BEAM GUSSET BETWEEN FRAMES 59-61 IAW EMB 145 SRM 51-40-02SDR HNAA2021090100410Gusset · corrodedCENTER BEAM GUSSET IS CORRODED BETWEEN FRAMES 59-61. REMOVED AND REPLACED CENTER BEAM GUSSET BETWEEN FRAMES 59-61 IAW EMB 145 SRM 51-40-02.SDR HNAA2021083100409Gusset · corrodedCENTER OMEGA BEAM GUSSET #5 IS CORRODED. R & R L/H LOWER LAV SIDE WALL SUPPORT PANEL (BANANA PANEL) IAW EMB-145 SRM 51-40-02.SDR HNAA2021083100408Gusset · corrodedCENTER OMEGA BEAM GUSSET #5 IS CORRODED. REMOVED AND INSTALLED NEW CENTER OMEGA BEAM GUSSET#5 IAW SRM 51-40-02SDR AALA202108263189Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR AALA202108207498Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON Z ANGLE LOCATED AT STA 1016 AND LEFT BUTT LINE 45. REMOVED AND REPLACED Z ANGLE.SDR AALA202108188406Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=2.20 IN, W=2.40 IN, D=0.038 IN, ON LEFT HAND TRANSITION PANEL. PANEL LOCATED BETWEEN STA 500F TO 500I AT LBL 25. REPLACED PANEL PER SRM 51-40-02 AND SRM 50-00-50-2R-5.SDR AALA202108165689Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT HAND AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL CENTER SHAPE FITTING BETWEEN FR 66 AND FR 68 AT S23L. REPLACED CENTER FITTING PER SRM 51-42-11.SDR V0XD20210816002Striker · dentedPASSENGER DOOR SURROUND, AFT TOP CORNER OF THE SEAL STRIKER FLANGE IS BENT BEYOND LIMITS. CORRECTIVE ACTION. REPAIRED THE SEAL STRIKER FLANGE BY CUTTING AWAY THE DAMAGE, FABRICATING AND INSTALLING REPAIR PARTS IAW BOMBARDIER REO 670-53-22-001 REV.J DATED2016-1SDR REXA2021081200568Angle · bentL/H ANGLE SUPPORT FOR FLOOR PNL LIGHTNING DIVERTER IS BEND BEYOND LIMITS BETWEEN FS 310 AND FS 333.
REMOVED AND REPLACED L/H ANGLE SUPPORT FS 310-333 IAW CRJ 900 SRM 51-42-13-001-001-A01. WVAC EMP #579269SDR AALA202108119540Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF RH TRANSITION PANEL BETWEEN STA 500C AND STA 500F AT STR 25R, MEASURING L=2.0 IN, W=1.0 IN, D=0.035 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 51-40-02.SDR AALA202108116199Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF RH TRANSITION PANEL BETWEEN STA 500A AND STA 500C AT RBL 26, MEASURING L=1.6 IN, W=1.0 IN, D=0.039 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 51-40-02.SDR AALA202108112296Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL AT FR 68 AND S23R. REPAIRED LOWER SILL PER SRM 53-41-14-300-001.SDR HNAA2021081000377Door Sill · corrodedE869837 - SSI 53-30-48 CORROSION ON CARGO DOOR SILL ... REMOVED AND REPLACED CARGO DOOR LOWER SILL IAW EMB145 SRM 51-40-02.SDR AALA202108069504Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT HAND AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL AT FR 68 AND S23L. REPAIRED LOWER SILL PER SRM 53-41-14-300-001.SDR DALA2021080404434Floor Support · corrodedSHIP 652 CORROSION ON FLOOR STRINGER RBL 2 AND 7, BTW STA 1497 TO 1460 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 01041: FLOOR STRINGER RBL 2 AND 7, BTW STA 1497 TO 1460 WAS REPLACED PER B757-200 SRM. (1895887)SDR SWAA2021091540272Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS400 RBL24 WL155. ; / [01] REMOVED INTEERCOSTAL CLIP BS 400 RBL 24 WL 155 IAW SRM 51-40-02. <BR>LOCATED AND DRILLED NEW INTERCOSTAL CLIP PER SRM 51-40-05. DWG 143A7505. <BR>REQUEST OK TO INSTALL; [02] VERIFIEDSDR SWAA2021091540302Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS870 RBL21 WL166. ; / [01] REMOVED CORROSION IN 1'X1' AREA REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE PART#ATS 2472 S/N UNKNOWN; [02] VERIFIED COSDR SWAA2021091400279Support Angle · corrodedCORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 LBL2 TO LBL9 WL179. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORRECTIVE ACTION ENTRSDR SWAA2021091540289Stiffener · corrodedCORROSION ON BULKHEAD STIFFENER AT AREA AFT OF ACB BS1017 RBL .5' WL191. MARKED ; / 02] REMOVED CORROSION ON BULKHEAD STIFFENER AT BS 1017 RBL WL191 IN AN AREA L=1.5' W=1' X=.008 WITH .032' ORIGIONAL THICKNESS AND .024 REMAINING. OUT OF LIMITS IAW SRM 53-80-08SDR SWAA2021091540271Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT FWD CARGO BAY BS452-BS480 RBL28 WL156. ; / [01] EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIG 0.045 IN A 1'X 28' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-1 USING DIAL DEPTH GAUGE PART# ATS2472 S/N UNKNOWN; [02] VSDR SWAA2021091540280Intercostal · corrodedCORROSION ON INTERCOSTAL AT AFT CARGO BAY BS932 RBL13 WL170. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORRECTIVE ACTION 1 PER SRM 51-10-02-0G-0; [03] REMOVSDR SWAA2021091400278Support Angle · corrodedCORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT FWD CARGO BAY BS500D LBL23 TO RBL18 WL156. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORRECTIVE ACTION ESDR SWAA2021091400273Shield · corrodedCORROSION ON FWD SHIELD AT FWD CARGO BAY BS420-440 RBL24 WL156. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORRECTIVE ACTION ENTRY 1.; [03] REMOVED FCB FWD SSDR SWAA2021091540274Shield · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500+5.5 LBL25 WL156. ; / [01] EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIG 0.040 IN A 1'X 1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE PART# ATS2472 S/N UNKNOWN; SDR SWAA2021091400276Shield · corrodedCORROSION ON AFT SHIELD AT FWD CARGO BAY BS500+6 RBL24 WL156. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0. SHIELD TO BE REPLACED ON CUST CARD#TTG8Q006051R; [02] CARD IS COMPSDR SWAA2021091400287Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS876 RBL21 WL166. ; / [01] REMOVED CORROSION IN 1'X1' AREA REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE PART#ATS 2472 S/N UNKNOWN. FLOOR TO SIDEWALSDR SWAA2021091400291Support Angle · corrodedCORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 RBL2 TO RBL19 WL179. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; BULKHEAD SUPPORT TO BE REPLACED ON SDR SWAA2021091400293Intercostal · corrodedCORROSION ON INTERCOSTAL AT AFT CARGO BAY BS929 RBL13 WL170. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0. INTERCOSTAL TO BE REPLACED ON CUST CARD# TTG8Q00608WM; [02] VERIFIESDR SWAA2021091400281Support Angle · crackedCRACKED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS918 RBL12 WL170. ; / [01] EVALUATED CRACK; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORRECTIVE ACTION 1 PER SRM 51-10
Back to JASC 5320