SDR SWAA2021091400294Support Angle · crackedCRACKED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS914 RBL12 WL170. ; / [01] EVALUATED CRACK; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] REMOVED OLD SUPPORT ANGLE; LOCATED AND DRISDR SWAA2021090799962Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 TO BS 328 AND RBL 31 FWD GALLEY AND LAV ; 202-341467 / [01] TOOL USED DIGITAL CALIPER P/N: DIGITAL150; S/N: AE-412605; DUE DATE: 25MAY22; [02] REPLACED WEB-INTERCOSTAL FLOOR STRUCTURE LOCATED BETWESDR SWAA2021090799963Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS 328 AND LBL 47 FWD GALLEY AND LAV ; 2021-341468 / [01] REMOVED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS 328 AND LBL 47 FWD GALLEY AND LAV I.A.W B737-700 SRM 51-40-02;TOOK SDR SWAA2021090799967Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS328 TO BS344 AND LBL47 FWD GALLEY AND LAV ; 2021-341470 / [01] TOOL USED DIGITAL CALIPER P/N: 700-113-10; S/N: 0033174; DUE DATE: 08JAN22.; [02] REPLACED WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN SDR SWAA2021090799977Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BETWEEN BS380 TO BS400 AND BL0 CENTER SECTION ; 2021-341511 / [01] TOOL USED; CALIPER P/N:700-113-10; S/N:0033174; DUE DATE:08JAN22.; [02] REPLACED SUPPORT ANGLE AND FASTENERS LOC BETWEEN BS380 TO BS400 AND BL0 CENTER SECTION IAW B7SDR SWAA2021090799964Structure · crackedCRACK INNER CHORD LOCATED BS 303.9 AND LBL55 AT FWD GALLEY AREA ; 2021-341473 / [01] REPLACED INNER CHORD LOC BS 277 TO BS 360 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02 AND DWG# 141A8110 REV-.SDR SWAA2021090799978Web · corrodedCORROSION WEB LOCATED BETWEEN BS 1006 TO BS1016 RBL40 AND WL208.1 AT AFT GALLEY AREA ; 2021-341507 / [01] REPLACED WEB LOCATED BETWEEN BS 1006 TO BS1016 RBL40 AND WL208.1 AT AFT GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 147A5730 REV C.SDR SWAA2021090700173Structure · corrodedCORROSION ON L/H INNER CHORD; BETWEEN STA 947 AND STA. 986.5 ; / [01] REMOVED CORROSION ON L/H INNER CHORD FROM STA 947 AND ASTA. 986.5 PER SRM 51-10-02-0G-0; FOUND EXFOLIATION CORROSION; OUT OF LIMITS PER SRM 53-70-15-1A-1; [02] VERIFIED REMOVED CORROSION ON SDR SWAA2021090799975Strap · corrodedCORROSION FLOOR STRUCTURE ON STRAP LOCATED BS1006 TO BS1016 LBL4 AND WL 208.1 AT AFT GALLEY AREA ; 2021-341504 / [01] TOOL USED DIGITAL CALIPER P/N: 700-113-10; S/N: 0023212; DUE DATE: 14SEP21.; [02] REPLACED STRAP LOCATED FLOOR STRUCTURE BS1006 TO BS1016 LBL4SDR HNAA2021083100407Door Sill · corrodedCARGO COMPARTMENT, ON THE BAGGAGE DOOR SILL THE BOTTOM SCREW HOLE FOR THE FWD TRIM HAS CORROSION BUILDUP. REMOVED AND INSTALLATED SERVICEABLE CARGO DOOR CENTER SILL IAW EMB 145 SRM 51-40-02SDR SWIA202160619Intercostal · corrodedL/H O/B INTERCOSTAL AT FR 84 - FR 85 HAS CORROSION AS MARKED. (C-CHECK RO 8/23/21) / REMOVED AND REPLACED LH OB INTERCOSTAL FR 84-85 REF EMB SRM 51-40-08. RESTORED SURFACE PROTECTION AT LH OB INTERCOSTAL FR 84-85 REF EMB SRM 51-23-04, 51-23-05, 51-23SDR AALA202108205592Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON LEFT TRANSITION PANEL LOCATED AT 727D - 815, ANS STR 25L. SPLICED IN NEW TRANSITION PANEL PER SRM 53-00-53-2R,SDR AALA202108209280Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: LEFT TRANSITION PANEL HAS CORROSION. REMOVED AND REPLACED LEFT TRANSITION PANEL LOCATED AT STA 767 - 847, STR 25L PER53-00-53-2R.SDR AALA202108208132Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON LEFT TRANSITION PANEL LOCATED AT 727H-767, STR 25L. REMOVED AND REPLACED TRANSITION PANEL PER SRM 53-00-53-2R.SDR ASAA2021073135740Strip · corrodedAFT FLOOR LANDING STRIP FOR PANEL 211AP HAS CORROSION SPOTS AT STA 268 VBETWEEN LBL 11 THRU RBL 11. GROUNDED - YES. REMOVED CORROISON, FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-10-51-1A-1. REPAIRED AREA IAW EA # 800-53EA-23741W= 1 1/2 O= .050 R= .040 L= 1"SDR ASAA2021073135692Angle · corrodedFLOOR Z-ZNGLE STRIP AT STA 992 HAS CORROSION SPOTS BETWEEN RBL 33 THRU RBL 44, IN THE AFT CABIN. GROUNDED - YES. LOCATED AND DRILLED NEW ZEE SUPPORT IAW 737-800 SRM 51-40-05-0G-0 CORROSION REMOVAL WAS 100% MATL LOSS AND IS OUT OF LIMITS IAW 737-800 SRM 53-70-5SDR ASAA2021073135691Web · corrodedFLOOR WEBB PLATE HAS A CORROSION SPOT AT STA 986 LBL 32, IN THE AFT CABIN. GROUNDED - YES. LOCATED AND DRILLED NEW WEB IAW 737-800 SRM 51-40-05-0G-0 CORROSION REMOVAL WAS 100% MATL LOSS AND IS OUT OF LIMITS IAW 737-800 SRM 53-70-51-1A-1 PART WAS REMOVED AND MISDR ASAA2021073135690Angle · corrodedFLOOR Z-ANGLE STRIP AT STA 992 HAS LIGHT CORROSION SPOTS BETWEEN LBL 33 THRU LBL 44. IN THE AFT CABIN. GROUNDED - YES. LOCATED AND DRILLED NEW ZEE SUPPORT IAW 737-800 SRM 51-40-05-0G-0 CORROSION REMOVAL WAS 100% MATL LOSS AND IS OUT OF LIMITS IAW 737-800 SRM 5SDR ASAA2021073135689Web · corrodedFLOOR WEB PLATE HAS CORROSION SPOTS BETWEEN STA 986 THRU STA 992 AND RBL 33 THRU RBL 44, IN THE AFT CABIN. GROUNDED - YES. LOCATED AND DRILLED REPLACEMENT WEB IAW 737-800 SRM 51-40-05-0G-0. CORROISON REMOVAL WAS 100% MATL LOSS AND IS OUT OF LIMITS IAW 737-800 SDR REXA2021081200555Intercostal · corrodedLH AND RH AVIONICS DOOR FWD INTERCOSTALS ARE CORRODED, BETWEEN FS 349 AND FS 364. REMOVED AND REPLACED INTERCOSTALS 27L ABD 27R AT FS 349 TO FS 364. REMOVED AND REINSTALLED 2 EA GUSSETS AND 2 EA. ANGLES AND PROX SWITCH BRACKET IAW CRJ 900 SRM'S 51-40-11-001-0SDR REXA2021081200554Intercostal · corrodedLH AND RH AVIONICS DOOR FWD INTERCOSTALS ARE CORRODED, BETWEEN FS 349 AND FS 364. REMOVED AND REPLACED INTERCOSTALS 27L ABD 27R AT FS 349 TO FS 364. REMOVED AND REINSTALLED 2 EA GUSSETS AND 2 EA. ANGLES AND PROX SWITCH BRACKET IAW CRJ 900 SRM'S 51-40-11-001-0SDR AALA202108113979Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF RH TRANSITION PANEL BETWEEN STA 727 AND STA 727H+5 AT STR 25R, MEASURING L=1.0 IN, W=2.0 IN, D=0.008 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R.SDR AALA202108114803Baffle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF BAFFLE AT FASTENER HOLES BETWEEN STA 500G AND STA 500H AT STR 27L, MEASURING L=3.0 IN, W=1.0 IN, D=0.01 IN. REPLACED BAFFLE WITH NEW IAW AARD 51-00-05.SDR AALA202108116395Angle · crackedAIRCRAFT IN BASE MAINTENANCE: BAFFLE CLIP LOCATED AT STA 500H AND S27L CRACKED. REPLACED BAFFLE CLIP PER DWG 143A7505 AND AARD 51-00-05.SDR AALA202108114542Angle · crackedAIRCRAFT IN BASE MAINTENANCE: BAFFLE CLIP LOCATED AT STA 500H AND S27L CRACKED. REPLACED BAFFLE CLIP PER DWG 143A7505 AND AARD 51-00-05.SDR AALA202108111706Angle · crackedAIRCRAFT IN BASE MAINTENANCE: BAFFLE CLIP LOCATED AT STA 500G AND S27L CRACKED. REPLACED BAFFLE CLIP PER DWG 143A7505 AND AARD 51-00-05.SDR AALA202108118618Baffle · damagedAIRCRAFT IN BASE MAINTENANCE: BAFFLE LOCATED BETWEEN STA 500E AND 500F AT S27L CRACKED. REPLACED BAFFLE PER DWG 143A7505 AND AARD 51-00-05.SDR YENA2021080400497Support · corrodedDURING HEAVY MAINTENANCE, CORROSION LOWER SILL LOC. FR68 AT LEVEL STR 23R AT GALLEY AREA (CPCP RELATED 534195-01); (RESOLVED ON W/O: 1114106 TASKCARD: NR-00009 ) PERFORMED PERMANT REPAIR ON LOWER SILL LOCATED AT LEVEL FR68 AND STR23R AFT GALLEY AREA IAW A321 SSDR DALA2021080304389Intercostal · crackedSHIP 669 CRACK ON INTERCOSTAL BTW STA 1640-1620 AND S-14L AT PASSENGER COMPARTMENT (IN REF. NRC:00137). CORRECTIVE ACTION: SUMMARY OF NRC 00320: INTERCOSTAL BTW STA 1640-1620 AND S-14L AT PASSENGER COMPARTMENT WAS REPLACED PER B757-200 SRM. (1894164)SDR AALA202108028776Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK FOUND ON SHEAR PLATE LOCATED BETWEEN FR 69 TO FR 70, AND STR 23R. LENGTH = 1.032 INCHES. REPLACED SHEAR PLATE AND FASTENERS PER A321 SRM 51-72-11-911-001.SDR REXA2021100500764Electrical Box · crackedEXT. POWER RECEPTACLE/ PLUG IN, BOX STRUCTURE CRACKED ON I/B SIDE OF RECEPTACLE. JC:900-53-130-300 IN:TB EMP#:432. REMOVED AND REPLACED AC EXTERNAL POWER RECEPTACLE BOX IAW (REO) 670-53-11-029 (CC670-33401 REF)SDR SWAA2021091500116Intercostal · crackedINTERCOSTAL CRACKED AT FWD CARGO BAY BS 500 LBL 24 WL 156 ; / [01] REMOVED INTERCOSTAL AT FWD CARGO BAY BS 500 LBL 24 WL 156 IAW SRM 51-40-02-0G-0-A00729; [02] CORRECTION MEASURES; [03] CORRECTED MEASUREMENTS SECTION; [04] LOCATED AND DRILLED NEW INTERCOSTAL ASDR SWAA2021091500092Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500C +14 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500106Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500A +10 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500100Sidewall Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 490 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BS 490SDR SWAA2021091500099Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500 +14 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSSDR SWAA2021091500080Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 480 +14 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSSDR SWAA2021091500073Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500A +6 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSSDR SWAA2021091500072Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500C +10 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500109Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 498 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 498 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500108Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 494.5 RBL 23 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 494.5 RBL23 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] SDR SWAA2021091500096Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500A +14 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500088Shield · corrodedCORROSION ON FWD SHIELD FWD CARGO BAY BS 431 RBL 23 WL 156 ; / [01] CORROSION FOUND ON FWD SHIELD FWD CARGO BAY BS 431 RBL23 WL156; P/N 143A8126-21; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500087Shield · corrodedCORROSION ON FWD SHIELD FWD CARGO BAY BS 425 RBL 24 WL 156 ; / [01] CORROSION FOUND ON FWD SHIELD FWD CARGO BAY BS 425 RBL24 WL156; P/N 143A8126-21; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500086Shield · corrodedCORROSION ON FWD SHIELD FWD CARGO BAY BS 422 RBL 23 WL 156 ; / [01] CORROSION FOUND ON FWD SHIELD FWD CARGO BAY BS 422 RBL23 WL156; P/N 143A8126-21; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500085Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 514 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 514 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500084Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 502 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 502 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500090Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT AFT CARGO BAY BS812 - BS831 RBL26 WL160. ; / [01] REMOVED CORROSION ON SUBTHRESHOLD WEB AT ACB BS812 - BS831 RBL26 WL160. REWORKED AREA L:6.3' W: 1' D: 0.010'; ORIGINAL THICKNESS: 0.045'; MAT REMOVED: 0.010'; REMAINING MAT: 0.0SDR SWAA2021091500094Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500A +14 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500077Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500 +10 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BS
Back to JASC 5320