JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023052431321Floor Panel · pulledPASSENGER FLOOR PANEL 231QF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REMOVED AND REPLACED CABIN FLOOR PANEL 231QF PER A.M.M. 53-21-00SDR SWAA2023052431320Floor Panel · pulledPASSENGER FLOOR PANEL 242QF HAS MULTIPLE DENTS/ PULLING FIBER<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR SWAA2023052431331Floor Panel · pulledPASSENGER FLOOR PANEL 242PF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR SWAA2023052431335Floor Panel · pulledPASSENGER FLOOR PANEL 241WF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR SWAA2023052431336Floor Panel · pulledPASSENGER FLOOR PANEL 241UF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR IPXA2023050693139Floor Panel · corrodedINSPECTION TYPE:3CCOURIER AREA R/H SIDE HAS A FLOOR PANEL WITH CORROSION 68 INCH FROM CL AT STA 421.578.REPLACED CORRODED FLOOR PANEL AT THE COURIER AREA R/H SIDE 68 INCH FROM CL AT STA 421.578 IAW SRM 51-31-01. (MINOR)SDR DALA2023042703309Unknown · unknownSHIP 6707 CRACK TWO (2 EAS) FLOOR BEAM STABILIZATION STRAPS BTW STA. 377.7 AND LBL 24.75 (PREVIOUSLY REPAIRED), ALSO BTW STA. 377.7 AND LBL 45.5. CORRECTIVE ACTION: SUMMARY OF NRC 00110-FLOOR BEAM STABILIZATION STRAPS BTW STA. 377.7 AND LBL 24.75, BTW STA. 377SDR IPXA2023050993181Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 152MG DAMAGEDFABBED PER SREO A300-5320-16407-ESDR SWAA2023050530844Floor Panel · delaminatedDOT #A114-007. CABIN FLOOROARD PANEL 242AF HAS AREAS OF PULLED FIBERS ALNOG EDGES AND CENTER ON UPPER SURGACE.<[01] WORK ACCOMPLISHED ON NON-ROUTINE TTG8Q00KMD1G;[02] VERIFIED STEP 1SDR SWAA2023050530847Floorboard · pulledDOT #114-012. CABIN FLOORBOARD PANEL 231ZF HAS AREAS OF PULLED FIBERS ON UPPER SURFACE.<[01] EVALUATED DAMAGE; TOP SIDE OF PANEL IS REPAIRABLE IAW B737 SRM 53-00-50-2R-1 REPAIR 1; TAP TEST GOOD NO DELAMINATION NOTED. <BR><BR>VERIFIED REPAIR MATERIALS IAW B737 SDR SWAA2023050530859Floorboard · pulledDOT #114-016. CABIN FLOORBOARD 232SF HAS AREAS OF PULLED FIBERS ALONG THE CENTER ON UPPER SURFACE.<[01] EVALUATED DAMAGE; TOP SIDE OF PANEL IS REPAIRABLE IAW B737 SRM 53-00-50-2R-1 REPAIR 1; TAP TEST GOOD NO DELAMINATION NOTED. <BR><BR>VERIFIED REPAIR MATERIALSDR SWAA2023050530860Floorboard · pulledDOT A114-017. CABIN FLOORBOARD 231XF HAS AREAS WITH PULLED FIBERS ON UPPER SURFACE.<[01] EVALUATED PANEL 231XF AND FOUND PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP. IAW B737-700 SRM 53-00-50-2RSDR ASAA2023042443014Floor Panel · peelingAFT WET AREA FLOOR PANEL PN 147A5810-477 HAS SURFACE DAMAGE. GROUNDED - YES. COMPLETED PERMANENT REPAIR OF AFT WET AREA FLOOR PANEL PN 147A5810-477 IAW B737-900 SRM 53-00-50-2R-0 & 53-00-50-2R-1.SDR ASAA2023042443013Floor Panel · peelingAFT WET AREA FLOOR PANEL PN 147A5810-440 HAS SURFACE DAMAGE. GROUNDED - YES. COMPLETED PERMANENT REPAIR OF AFT WET AREA FLOOR PANEL PN 147A5810-440 IAW B737-900 SRM 53-00-50-2R-0 & 53-00-50-2R-1CJONES 117284 04/26/2023.SDR DALA2023042703289Unknown · unknownCORROSION ON GALLEY SUPPORT STA 218 RBL 11 AT PAX CABIN FLOOR STRUCTURE. W1. SUMMARY OF NRC 597: CORROSION LEVEL 2. GALLEY SUPPORT STA 218 RBL 11 AT PAX CABIN FLOOR STRUCTURE WAS REPLACED PER B717-200 SRM 51-41-05-0G. (LP #2735690)SDR DALA2023042703288Unknown · unknownCORROSION ON FLOOR SUPPORTS STA Y=198 LBL 57 AT PAX CABIN FLOOR SUPPORT. CPAX. SUMMARY OF NRC 00596: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=198 LBL 57 AT PAX CABIN FLOOR SUPPORT WAS REPLACED PER B717-200 SRM 51-41-01-0G AND SRM 51-41-05-0G. (LP #2735528)SDR DALA2023042503223Unknown · unknownSHIP 672 CORROSION ON FLOOR SUPPORT RBL 7.55 BTW STA 700-760 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00414: FLOOR SUPPORT RBL 7.55 BTW STA 700-770 AT FWD CARGO COMPARTMET WAS REPAIRED PER B757- 200 SRM. (2735592)SDR SWAA2023052430175Splice · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; CARGO FLOOR SPLICE CORRODED AT STA 887.<[01] BLENDED CORROSION ON AFT CARGO FLOOR SPLICE AT STA. 887 PER SRM 51-10-02. REMOVED .023 OF MATERIAL. REMAINING THICKNESS IS .047?. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-00-SDR SWAA2023052430186Floor Panel · corrodedAFT CARGO STA 767 + 4' FLOOR PANEL SPICE STRIP HAS CORROSION<[01] BLENDED CORROSION ON AFT CARGO FLOOR PANEL SPLICE AT STA. 767+4? PER SRM 51-10-02. REMOVED .040? OF MATERIAL. REMAINING THICKNESS IS .030?. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-00-53-1A-2.SDR SWAA2023051130220Floor Panel · delaminatedDELAMINATED FLOOR PANEL 231ZF AT PASSENGER CABIN 2023-247749<[01] TOOL USED CALIPER P/N 500-464 S/N B17030933 DUE DATE 17-OCT-23;[02] TOOL USED HOT BONDER P/N: HCS9200B-AV; S/N: 18175478 DUE DATE: 24-SEP-23.;[03] TOOL USED SCALE P/N SPX621 S/N 8340225441 DUE DSDR SWAA2023042730410Floor Panel · crackedFWD CARGO AFT FLOOR PANEL HAS A CRACK 9.5 INCHES IN LENGTH<[01] REMOVED AND REPLACED FWD CARGO AFT FLOOR PANEL IAW AMM 25-52-10.SDR FDEA202304230744Floor Panel · damagedMAIN DECK,FLOOR BOARD 273 JF HAS DAMAGED AND MISSING INSERTS. FABRICATED NEW FLOOR PANEL 273JF PER SRZ-25-005,REV R. MAJOR REPAIR.SDR SWAA2023052430118Floor Panel · pulledFWD FLOOR PANEL 221CF UPPER SKIN HAS AN AREA OF PULLED STRANDS. (MARKED)<[01] IDENTIFIED PANEL 221CF MATERIAL IAW SRM 53-00-50-0I-1 FIG. 2 TABLE 2.<BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR. 4.F.<BR><BR>REMOVED 15EA INSERTS IAW SRSDR SWAA2023052430125Floor Panel · pulledAFT FLOOR PANEL 241XF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] COMPLETED ALL STEPS OF EA 23-153-01348.;[02] JOB COMPLETE.SDR SWAA2023052430126Floor Panel · pulledAFT FLOOR PANEL 241ZF HAS AN AREA OF PULLED STRANDS.<[01] IDENTIFIED PANEL IAW SRM 53-00-50-0I-1 FIGURE 6. AREA OF PULLED STRAND DAMAGE IS BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F AND WILL BE REPAIRED IAW SRM 53-00-50-2R-1. REMOVED AN APPROXSDR SWAA2023052430121Floor Panel · pulledFWD FLOOR PANEL 221BF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221BF UPPER SKIN WITH MULTIPLE AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO THE AMOUNT OF ALL DAMAGE.;[02SDR SWAA2023052430122Floor Panel · pulledFWD FLOOR PANEL 221GF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221GF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB SDR SWAA2023052430124Floor Panel · pulledFLOOR PANEL 222DF UPPER SKIN HAS AN AREA OF PULLED STRANDS. (MARKED)<[01] IDENTIFIED FLOOR PANEL 222DF IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2 AND BOEING DWG 141A5810-749.<BR><BR>DAMAGE TO UPPER SURFACE SKIN PLIES IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50SDR SWAA2023052430132Floor Panel · pulledAFT FLOOR PANEL 241YF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241YF WITH MULTIPLE AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2023052430127Floor Panel · pulledAFT FLOOR PANEL 241AAF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 241AAF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6. FLOOR PANEL 241AAF DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. FLOOR PANEL UPPER SUSDR SWAA2023052430128Floor Panel · pulledAFT FLOOR PANEL 241ABF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] VERIFIED COMPLETION OF FABRICATION OF PANEL 241ABF IAW EA 23-153-01350;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2023052430129Floor Panel · pulledAFT FLOOR PANEL 241ACF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] VERIFIED COMPLETION OF FABRICATION OF PANEL 241ACF IAW EA 23-153-01354;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2023052430130Floor Panel · pulledAFT FLOOR PANEL 241ADF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] VERIFIED COMPLETION OF FABRICATION OF PANEL 241ADF IAW EA 23-153-01353;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2023052430133Floor Panel · pulledAFT FLOOR PANEL 242RF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 242RF WITH MULTIPLE AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2023052430134Floor Panel · pulledAFT FLOOR PANEL 242TF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] VERIFIED COMPLETION OF FABRICATION OF PANEL 242TF IAW EA 23-153-01351;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2023052430131Floor Panel · pulledAFT FLOOR PANEL 242UF HAS MULTIPLE AREAS OF PULLED STRANDS<[01] IDENTIFIED PANEL 242UF IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6<BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4 B<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1<BR><BRSDR SWAA2023052430135Floor Panel · pulledAFT FLOOR PANEL 242VF HAS MULTIPLE AREAS OF PULLED STRANDS<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND MULTIPLE AREAS OF ADDITIONAL DAMAGE ON LOWER SURFACE; ALL DAMAGE FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PSDR SWAA2023052430136Floor Panel · crackedAFT FLOOR PANEL 242XF TOP SURFACE IS CRACKED.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.B.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>REMOVED DAMAGEDSDR SWAA2023051130212Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241BF DELAMINATED<[01] APPLY THE GLASS FABRIC REPAIR PLIES AT DAMAGED AREA ON MAIN CABIN FLOOR PANEL 241BF.;[02] ENTERED AS ERROR STEP 1;[03] REMOVED AND INSTALLED FLOOR PANEL 241BF IN REF AMM- 53-21-00-000-801; 53-21-00-400-801;[04] VERSDR IPXA2023050993178Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 151LG DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993177Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 152KG DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993176Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 1515F DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993175Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 1515F DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993174Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 151RF DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993173Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 152UF DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993172Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 151TF DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993170Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL 131DE IS DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993169Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL131BH DAMAGEDFABBED PER SREO A300-5320-16407-ESDR IPXA2023050993168Floor Panel · damagedINSPECTION TYPE:1C2C*MAJOR REPAIR* PNL121FF DAMAGEDFABBED PER SREO A300-5320-16407-ESDR DALA2023042403180Unknown · unknownAIRCRAFT 3939, ASSENGER COMPARTMENT, R1 DOOR LOWER INNER CHORD AT WL 208 FROM BS 332 TO BS 360 RBL 56 HAS TOOLS MARKS. CORRECTIVE ACTION: INSTALLED EWIS PROTECTION AT R1 DOOR IAW B737 AMM 20-60-07-913- 801, REMOVED AND REPLACED R1 DOOR LOWER INNER CORD AT STA
Back to JASC 5321