JASC 5322

Service difficulty reports · 12,776

Reports filed under 5322 · Fuselage Internal Mounting Structure, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5322'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWIA202264860None · corrodedTOP OF PRESSURE FLOOR BEAM AT LBL9 FROM 409.00+120 TO FS 461.00 IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED PRESSURE FLOOR BEAM AT LBL 9.00 FROM 409.00+120 TO F.S. 461.00 I.A.W. MHIRJ REO 601R-53-41-3002 REV.A, DATED 2022-01-25. COMPLIED WITH SKJan 5, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264858None · corrodedRH FLOOR SILL FROM FS 559.00 TO FS 559.00+32 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REMOVED AND REPLACED FLOOR SILL I.A.W. BOMBARDIER CRJ200 SRM 51-42-06 AND 51-42-21 REV.38B, DATED 11/25/2020. COMPLIED WITH SKYWEST TASK CARD 51-900-1003Jan 5, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264521None · corrodedL/H FS280 FLOOR BEAM HAS CORROSION (C CHECK RO 2/17/2022) REMOVED AND INSTALLED NEW L-H FS280 FLOOR BEAM, REF. DRAWING CC670-34010 REV K, CRJ 700 SRM 51-42-06-001-001-A01, CRJ 700 SRM 51-42-22-001-001-A01, CRJ 700 SRM 51-42-13-001-001-A01 AND CRJ 700 SRM 5Jan 5, 2022 · N771SK · Cndair CL6002C10SDR SWIA202264443None · corroded*CORROSION FOUND IN SEVERAL SPOTS ON R/H FLOORSILL BETWEEN FS1069.75 AND FS1088.00 (MARKED) (C-CHECK RO 2/16/2022) PERFORMED REO REPAIR OF FLOOR SILL BETWEEN FS 1069.75 AND FS 1088.00 R/H SIDE. FLOOR SILL REPAIRED PER REO 690-53-61-1056 REV -- DATED 20Jan 5, 2022 · N823SK · Cndair CL6002D24SDR SWIA202264442None · corroded*CORROSION FOUND ON R/H FLOORSILL BETWEEN FS1031.00 AND FS1051.00 (MARKED) (C-CHECK RO 2/16/2022) ORIGINAL THICKNESS 0.063" REF CRJ900 SRM 53-61-43-001-001-A01. REMAINING THICKNESS 0.058", MATERIAL LOSS 0.005", ALLOWED 0.020" FOUND TO BE WITHIN LIMITS RJan 5, 2022 · N823SK · Cndair CL6002D24SDR SWIA202264441None · corroded*CORROSION FOUND IN SEVERAL SPOTS ON L/H FLOORSILL BETWEEN FS985.00 AND FS1000 (MARKED) (C-CHECK RO 2/16/2022) REPLACED LH FLOOR SILL BETWEEN FS985.00 TO FS1000.00 REF MHIRJ REO 690-53-61-1057 REV.-- DATED 2022-01-10. COMPLIED WITH 51-900-1002-SKY.Jan 5, 2022 · N823SK · Cndair CL6002D24SDR SWIA202264440None · corroded*CORROSION FOUND ON FLOOR BEAM SUPPORT AT FS985.00 AT APPROX LBL42 (MARKED) (C-CHECK RO 2/16/2022) REPLACED FLOOR BEAM SUPPORT AT FS985.00 AT APPROX. LBL 42 REF DWG MM670-35041 REV. Y AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY.Jan 5, 2022 · N823SK · Cndair CL6002D24SDR SWIA202264439None · corroded*CORROSION FOUND AROUND NUTPLATE ON L/H FLOORSILL BETWEEN FS927.00 AND FS942.00 (MARKED) (C-CHECK RO 2/16/2022) REMOVED CORROSION AROUND NUTPLATE ON LH FLOOR SILL BETWEEN FS927.00 AND FS 942.00. OMPLIED WITH ALL STEPS OF MHIRJ GREO 670-53-00-390 REV --,Jan 5, 2022 · N823SK · Cndair CL6002D24SDR SWIA202263763None · bentFLOOR SUPPORT STRUCTURE SUPPORT ANGLE LOCATED AT LBL27 BETWEEN FS349 - FS364 IS BENT/DEFORMED. (FILED- OPEN) REMOVED AND REPLACED FLOOR SUPPORT STRUCTURE SUPPORT ANGLE AT LBL27 BETWEEN FS349 - FS364 IN REFERENCE TO SRM 51-42-13.Jan 5, 2022 · N741EV · Cndair CL6002C10SDR SWIA202263762None · bentFLOOR SUPPORT STRUCTURE SUPPORT ANGLE LOCATED AT LBL27 BETWEEN FS333 - FS349 IS BENT/DEFORMED. (FILED- OPEN) REMOVED AND REPLACED FLOOR SUPPORT STRUCTURE SUPPORT ANGLE AT LBL27 BETWEEN FS333 - FS349 IN REFERENCE TO SRM 51-42-13.Jan 5, 2022 · N741EV · Cndair CL6002C10SDR SWIA202263761None · bentFLOOR SUPPORT STRUCTURE SUPPORT ANGLE LOCATED AT LBL27 BETWEEN FS310 - FS333 IS BENT/DEFORMED. (FILED- OPEN) REMOVED AND REPLACED FLOOR SUPPORT STRUCTURE SUPPORT ANGLE AT LBL27 BETWEEN FS310 - FS333 IN REFERENCE TO SRM 51-42-13.Jan 5, 2022 · N741EV · Cndair CL6002C10SDR SWIA202265304None · elongatedBL 0.00 FLOOR BEAM TENSION STRAP AT APPROX FS 773.50 FOUND TO HAVE ELONGATED FASTENER HOLE (C-CHECK RO 4/9/2022) COMPLIED WITH REO 670-53-41-593 REV -- DATED 2022-02-24. NO CHANGE TO WEIGHT AND BALANCE, M-337 AND TASK CARD 51-900-1002-SKY ATTACHED.Jan 4, 2022 · N715SK · Cndair CL6002C10SDR SWIA202264978None · corrodedLH PRESSURE FLOOR SILL PANEL FROM FS 484.00 TO FS 529.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED L/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-301 REV.--, DATED 2022-01Jan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264856None · corrodedRH PRESSURE FLOOR SILL PANEL FROM FS 529.00 TO FS 559.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL PANEL FROM F.S. 529.00 TO F.S. 559.00 I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ RJan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264854None · corrodedRH PRESSURE FLOOR SILL PANEL FROM FS 484.00 TO FS 529.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-3008 REV.--, DATED 2022-Jan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264853None · corrodedRH PRESSURE FLOOR SILL PANEL FROM FS 449.00 TO FS 484.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-3016 EV.--, DATED 2022-0Jan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264851None · corrodedRH PRESSURE FLOOR SILL PANEL FROM FS 409.00+112 TO FS 449.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06 AND MHIRJ REO 601R-53-41-3016 REV.--, DATEJan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264850None · corrodedRH PRESSURE FLOOR SILL ANGLE FROM FS 529.00 TO FS 559.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED CORROSION ON THE RH PRESSURE FLOOR SILL ANGLE FROM FS 529.00 TO FS 559.00 IAW BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-0Jan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264849None · corrodedRH PRESSURE FLOOR SILL ANGLE FROM FS 484.00 TO FS 529.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED DAMAGED RH FLOOR SILL ANGLE BETWEEN FS 499-513, FS 524 AND FS 529 IAW REO 601R-53-41-666 REV C DATED 2012-11-06 AND INSTALLED ALTERJan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264847None · corrodedRH PRESSURE FLOOR SILL ANGLE FROM FS 449.85 TO FS 484.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED CORROSION DAMAGE AT FS 449,461 AND 473 IAW REO 601R-53-41-666 REV C DATED 2012-11-06 AND INSTALLED ALTERNATE FASTENERS AT INACCESSAJan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264845None · corrodedLH PRESSURE FLOOR SILL PANEL FROM FS 529.00 TO FS 559.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED L/H PRESSURE FLOOR SILL I.A..W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012/11/06 AND MHIRJ REO 601R-53-41-3012 REV.--, DATED 20Jan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264843None · corrodedRH PRESSURE FLOOR SILL ANGLE FROM FS 409.00+112 TO FS449.85 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL ANGLE IAW BOMBARDIER REO 601R-53-41-666, REV -C DATED2012-11-06 AND MHIRJ REO 601R-53-41-3016, REV -- DAJan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264841None · corrodedLH PRESSURE FLOOR SILL PANEL FROM FS 449.85 TO FS 484.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED CORROSION ON LH PRESSURE FLOOR SILL PANEL FROM F.S. 449.85 - 484.00 IAW REO 601R-53-41-666 REV C DATED 2012-11-06 AND REO 601R-53-41Jan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264839None · corrodedLH PRESSURE FLOOR SILL PANEL FROM FS 409.00+112 TO FS 449.85 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED L/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-3010 REV.--, DATED 20Jan 4, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264520None · crackedFLOOR BEAM BL12L OUTBOARD ANGLE ATTACHING TO FS280.00 BEAM IS CRACKED, (C CHECK RO 2/17/2022) REMOVED AND REPLACED FLOORBEAM LBL12 OUTBOARD ANGLE ATTACHING TO FS280 REF CRJ700 SRM 51-42-21-001-001-A01, DRAWING CC670-33052 REV -G. COMPLIED WITH ST 51-900-Jan 4, 2022 · N771SK · Cndair CL6002C10SDR YENA2022021700072None · noneDURING HEAVY MAINTENANCE, (E/C A21-1368-01) FUSELAGE / AVANT/VIASAT2 MODIFICATION / FR 33-34 AT STGR 5R-6R / SHORT EDGE DISTANCE - TIME LIMITED REPAIR.(CONSIDERED A MAJOR REPAIR)Jan 4, 2022 · N804JB · Airbus A320232SDR SWIA202264011None · corrodedFLOOR SUPPORT ANGLE LOCATED ON THE AFT SIDE OF THE LOWER FS280.00 BULKHEAD FRAME AT BL 0 IS CORRODED. (C-CHECK RO 1/19/2022) REMOVED AND REPLACED WITH NEW FLOOR SUPPORT ANGLE ON AFT SIDE OF THE LOWER FS280.00 BULKHEAD FRAME AT BL 0. REF CRJ900 SRM 51-Jan 4, 2022 · N822SK · Cndair CL600*SDR SWIA202164635None · corrodedUPPER SURFACE OF LONGITUDINAL FLOORBEAM AT FS1016 - FS1047 RBL9 HAS CORROSION. (C CHECK RO 02/22/2022) REPAIRED FLOOR BEAM AT RBL9 BETWEEN FS1016 AND FS1047 REF. CRJ-700 SRM 53-00-41-201-001-A01 AND REO 670-53-61-2049 REV --, DATED 2022-01-25. COMPLIED WIDec 31, 2021 · N713SK · Cndair CL6002C10SDR SWIA202164634None · corrodedUPPER SURFACE OF LONGITUDINAL FLOORBEAM AT FS1016 - FS1047 LBL9 HAS CORROSION. (C CHECK RO 02/22/2022) REPAIRED FLOOR BEAM AT LBL9 BETWEEN FS1016 AND FS1088 REF. CRJ-700 SRM 53-00-41-201-001-A01 AND REO 670-53-61-2049 REV --, DATED 2022-01-25.. COMPLIED WDec 31, 2021 · N713SK · Cndair CL6002C10SDR SWIA202164512None · corrodedBACKUP SILL BETWEEN FS333.00 AND FS349.00 AT STGR21L CORRODED. (C CHECK RO 2/17/2022) REMOVED AND REPLACED CORRODED BACK UP SILL ON STGR21L BETWEEN FS333.00 AND FS349.00 WITH NEW BACK UP SILL (P/N SH670-31823-1) USING ALL NEW FASTENERS. REF BOMBARDIER DWG#Dec 30, 2021 · N771SK · Cndair CL6002C10SDR SWIA202164275None · brokenL/H FLOOR SILL HAS 2 EA BROKEN NUTPLATES AT FS 439.00 (C CHECK RO 2-11-2022) REMOVED AND REPLACED L/H FLOOR SILL 2 EA NUTPLATES AT FS 439.00 IAW CRJ200 SRM 51-45-00Dec 30, 2021 · N930SW · Cndair CL6002B19SDR SWIA202164315None · corrodedUPON REMOVAL OF THE PAX DOOR FLOOR SILL ANGLE FOUND CORROSION ON FLOOR STRIKER SEAL AFT CORNER. (C CHECK RO 02-12-2022) REMOVED CORROSION ON FLOOR STRIKER SEAL AFT CORNER REF CRJ200 SRM 51-21-06. FOUND TO BE WITHIN LIMITS REF CRJ200 SRM 53-00-00. RESTORDec 27, 2021 · N929SW · Cndair CL6002B19SDR SWIA202164314None · corrodedUPON REMOVAL OF THE PAX DOOR FLOOR SILL ANGLE FOUND CORROSION ON CROSSBEAM AT FS349 APROX LBL41 (C CHECK RO 02-12-2022) REPAIRED CROSSBEAM AT FS349 APROX LBL41 REF. REO 601R-53-21-3521 REV-- DATED: 2022-01-06. COMPLIED WITH 51-900-1003-SKY AND SEE CONTINUDec 27, 2021 · N929SW · Cndair CL6002B19SDR SWIA202164312None · corrodedUPON REMOVAL OF PAX DOOR FLOOR SILL ANGLE FOUND CORROSION ON PAX DOOR FLOOR SILL APPROX FS 349 (C CHECK RO 02-12-2022) CORROSION REMOVED AT PAX DOOR FLOOR SILL APPROX FS 349 REF CRJ200 SRM 51-21-06, WITHIN LIMITS REF CRJ200 SRM 53-00-00. FINISH RESTORED ONDec 27, 2021 · N929SW · Cndair CL6002B19SDR SWIA202163806None · corrodedCORROSION - LH SILL AT FR19 (C CHECK RO 1/14/2022) / REMOVED AND REPLACED LH SILL AT FR19 REF EMB SRM 51-40-08Dec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163805None · noneCORROSION, AFT WET AREA, ON LH SPLICE PLATE AT FRAME 89. (C CHECK RO 1/14/2022) / REMOVED AND REPLACED LH SPLICE PLATE AT FRAME 89 REF EMB SRM 51-40-08 AND RESTORED SURFACE PROTECTION REF EMB SRM 51-23-06Dec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163804None · corrodedCORROSION, AFT WET AREA, ON RH SHEAR PANEL BETWEEN FRAMES 86 AND 87 AROUND GALLEY MOUNT POINTS AND ALONG FORWARD EDGE (C CHECK RO 1/14/2022) / REMOVED AND REPLACED RH SHEAR PANEL BETWEEN FRAMES 86 AND 87 REF EMB SRM 51-40-08 SEE CONTINUATION CARD FOR WORDec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163803None · corrodedCORROSION, AFT WET AREA, ON CENTER SHEAR PANEL BETWEEN FRAMES 86 AND 87 AROUND GALLEY MOUNT POINT AND FORWARD EDGE. (C CHECK RO 1/14/2022) / REMOVED AND REPLACED CENTER SHEAR PANEL BETWEEN FRAMES 86 AND 87 REF EMB SRM 51-40-08 SEE CONTINUATION CARD FOR WODec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163800None · corrodedCORROSION, AFT WET AREA INTERNAL SIDE OF FUSELAGE BELOW FLOOR, ON SHEAR CLIP ATTACHED TO FRAME 88 BETWEEN STRINGERS 28R AND 27R. (C CHECK RO 1/14/2022) / REMOVED AND REPLACED AFT WET AREA INTERNAL SIDE OF FUSELAGE BELOW FLOOR, ON SHEAR CLIP ATTACHED TO FDec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163799None · corrodedCORROSION, AFT WET AREA INTERNAL SIDE OF FUSELAGE BELOW FLOOR, ON SHEAR CLIP ATTACHED TO FRAME 85 BETWEEN STRINGERS 28R AND 27R. (C CHECK RO 1/14/2022) / REMOVD AND REPLACED AFT WET AREA INTERNAL SIDE OF FUSELAGE BELOW FLOOR, ON SHEAR CLIP ATTACHED TO FRADec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163798None · corrodedCORROSION, AFT WET AREA, ON RH LONGITUDINAL FLOOR BEAM FORWARD OF FRAME 87 IN AN ELONGATED SCREW HOLE. (C CHECK RO 1/14/2022) / REMOVED AND REPLACED RH LONGITUDINAL FLOOR BEAM FORWARD OF FRAME 87. BEAM WAS REPLACED WITH OEM PART NO CHANGE TO WEIGHT AND BADec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163796None · corrodedCORROSION, AFT WET AREA, ON LH LONGITUDINAL FLOOR BEAM AT FRAME 87 WHERE THE BEAM PASSES BETWEEN THE LH AND CENTER SHEAR PANELS. (C CHECK RO 1/14/2022) / REMOVED AND REPLACED LH LONGITUDINAL FLOOR BEAM AT FRAME 87 REF EMB SRM 51-40-08 SEE CONTINUATION CARDec 26, 2021 · N240SY · Emb ERJ170200LRSDR SWIA202163760None · corrodedBACKUP SILL BETWEEN FS 310.00 TO 333.00 AND STGR 21L CORRODED. (FILED- OPEN) REMOVED AND REPLACED BACKUP SILL BETWEEN FS 310.00 TO 333.00 AND STR 21L WITH REFERENCE TO SRM 51-42-06. COMPLIED WITH TASK CARD 51-900-1002-SKY. COMPLETED M-337.Dec 26, 2021 · N741EV · Cndair CL6002C10SDR YENA2022031600241Frame · unknownDURING HEAVY MAINTENANCE, (EA A21-1329-01) FUSELAGE / AVANT/VIASAT2 MODIFICATION / FR 33-34 @ STGR 5R-6R /SHORT EDGE DISTANCE - TIME LIMITED REPAIR (CLASSIFIED AS A MAJOR REPAIR)Dec 23, 2021 · N821JB · Airbus A320232SDR SWIA202164615None · corroded*LH SILL AFT OF FS280.00 IS CORRODED. FLAGGED (C CHECK RO 02/22/2022) REMOVED CORROSION ON LH FLOOR SILL INBOARD CORNER AT FS281.00. BLEND IS WITHIN ALLOWABLE LIMITS. RESTORED FINISH. REF: CRJ700 SRM 51-21-06-001-001-A01, 53-00-45-201-001-A01 AND 53-21-45Dec 19, 2021 · N713SK · Cndair CL6002C10SDR SWIA202164310None · damagedPAX DOOR FLOOR SILL FS310-FS349 IS EXFOLIATED NEEDS REPLACED. (C CHECK RO 02-12-2022) REMOVED AND REPLACED PAX DOOR FLOOR SILL ANGLE AT FS 310- FS 349 IAW CRJ 200 SRM 51-42-06, CRJ 200 SRM 51-42-21 AND DWG 601R31527 REV AM COMPLIED WITH TASK CARD 51-900-10Dec 19, 2021 · N929SW · Cndair CL6002B19SDR SWIA202164964None · corrodedR/H FLOOR SILL CORRODED ON LOWER SIDE AROUND RIVET BUCKTAIL AT FS 620.00 (C CHECK RO 3/11/2022) REMOVED AND INSTALLED R/H FLOOR SILL FROM FS 563 - 621 IAW GENERIC REO 601R-53-61-5376, REV-A, DATED 2018-10-25 AND DEVIATION REO'S 601R-53-61-7798, REV --, DADec 18, 2021 · N877AS · Cndair CL6002B19SDR SWIA202164610None · corroded*CORROSION ON RH PRESSURE FLOOR ANGLE LOCATED AT FS 813.00. MARKED. (C CHECK RO 02/22/2022) REMOVED CORROSION ON RH PRESSURE FLOOR ANGLE LOCATED AT FS 813.00, REF. CRJ700 SRM 51-21-06-001-001-A01. ORIGINAL MATERIAL THICKNESS IS 0.125€? REF CRJ700 SRM 53-4Dec 18, 2021 · N713SK · Cndair CL6002C10SDR DALA2021122107927None · noneSHIP 3317 RIVETS SHEARED ON FWD CARGO BIN CEILING SUPPORT ANGLE 24 AND 28 INCHES I/B OF RH END OF FLOOR BEAM 22. CORRECTIVE ACTION: REF AIB INSTRUCTION R53270227. (2056693)Dec 18, 2021 · N817NW · Airbus A330323SDR SWIA202164335None · corrodedFLOOR BEAM RBL9 FS424.0 - FS484.0 HAS CORROSION ON FLOOR SILL (MARKED) (C CHECK RO 02-12-2022) REPAIRED FLOOR BEAM INBOARD FLANGE RBL9 BETWEEN FS424.0 - FS499.0. REF REO 601R-53-41-3003 REV. -- DATE 2022-01-11Dec 16, 2021 · N929SW · Cndair CL6002B19
Back to JASC 5322