SDR SWIA202164325None · damaged2EA FASTENERS DAMAGED ON FLOOR BEAM RBL9 FS559+64 (MARKED) (C CHECK RO 02-12-2022) REMOVED AND REPLACED DAMAGED FASTENERS AT FLOOR BEAM RBL9 FS559+64 REF CRJ 200 SRM 51-42-06SDR SWIA202164297None · corroded* THE GALLEY FITTING BETWEEN RBL27 AND RH FLOOR SILL AND FS280 AND FS295 HAS CORROSION. (MARKED) (C CHECK RO 02-12-2022) REMOVED CORROSION AT THE GALLEY FITTING BETWEEN RBL27 AND RH FLOOR SILL AND FS280 AND FS295. REF CRJ-200 SRM 51-21-06. FOUND TO BE IN LSDR SWIA202164296None · corroded* THE RH PRESSURE FLOOR SILL PANEL HAS CORROSION BETWEEN FS409.00+128 TO FS499 APPROX. (MARKED) (C CHECK RO 02-12-2022) BLENDED AREAS WITHIN LIMITS RH PRESSURE FLOOR SILL PANEL BETWEEN FS409.00+128 TO FS499 / REF BOMBARDIER REO 601R-53-41-666 REV-C, DASDR SWIA202164295None · corroded* THE LH PRESSURE FLOOR SILL ANGLE HAS CORROSION BETWEEN FS449.85 TO FS461 APPROX. (MARKED) (C CHECK RO 02-12-2022) BLENDED CORROSION ON LH PRESSURE SILL ANGLE BETWEEN FS 449.85 TO FS 461 REF REO 601R-53-41-666 REV -C DATE 2012-11-06 AND BLENDED AREA IS SDR SWIA202164294None · corroded* THE LH PRESSURE FLOOR SILL PANEL HAS CORROSION BETWEEN FS449.85 TO FS461 APPROX. (MARKED) (C CHECK RO 02-12-2022) REPAIRED LH PRESSURE FLOOR SILL PANEL BETWEEN FS449.85 TO FS461 REF REO 601R-53-41-666 REV C DATED 2012-11-06 STEP 1.2 A-F. COMPLIED WITH 5SDR SWIA202164292None · corrodedRH FLOOR SILL HAS MULTIPLE AREAS OF CORROSION FROM FS589.00 TO FS559+96 (MARKED) (C CHECK RO 02-12-2022) REPAIRED R/H FLOOR SILL BETWEEN FS 559+112 TO 605 REF REO 601R-53-00-526 REV -- DATED 22-MAY-2013. SEE CAMP 24163913 FOR REPLACEMENT OF RH CARGO FLOOSDR SWIA202164291None · corrodedLH FS461.00 FRAME ON THE FLOOR SILL HAS CORROSION (MARKED) (C CHECK RO 02-12-2022) REMOVED CORROSION @LH FS461.00 FR ON THE FLOOR SILL PER REF CRJ 200 SRM 51-21-06. PART FOUND TO BE WITHIN LIMITS AND REPAIR ACCOMPLISHED IAW REO 601R-53-41-2998 REV-- DATE SDR SWIA202164290None · crackedLBL36 FLOOR BEAM SUPPORT FITTING FS460.0 SUSPECTED CRACK (MARKED) (C CHECK RO 02-12-2022) INSTALLED LBL36 FLOOR BEAM SUPPORT FITTING FS360.0 IAW REO 601R-53-41-2997 REV -- DATE 2021-12-27 . PERFORMED LEAK CHECK REF CRJ 200 AMM 21-32-00-863-801. LEAK CHECKSDR SWIA202164288None · crackedLBL18 FLOOR BEAM SUPPORT FITTING AT FS460.0 HAS A SUSPECTED CRACK ON THE UPPER AND LOWER CORNERS (MARKED) (C CHECK RO 02-12-2022) REMOVED AND INSTALLED NEW FLOOR BEAM SUPPORT FITTING FS460.0 LBL18 REF DWG 601R31118 REV L AND CRJ 200 SRM 51-42-21. COMPLIED SDR SWIA202163549None · corrodedPAX FLOOR, MILLED FITTING CORRODED JUST AFT OF PAX DOOR BETWEEN FRAMES 19-20. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED PAX FLOOR, MILLED FITTING AFT OF PAX DOOR BETWEEN FRAMES 19-20 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-04, 51-23SDR SWIA202163548None · corrodedPAX FLOOR SHEAR PLATE CORRODED AT FRAME 19 BETWEEN AISLE AND FWD PAX DOOR. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED PAX FLOOR SHEAR PLATE BETWEEN FR 19-20. REF EMB SRM 51-40-08. SEE CONTINUATION FOR WORK PERFORMED.SDR SWIA202163547None · corrodedPAX FLOOR SHEAR PLATE CORRODED AT FRAME 17 NEAR SERVICE DOOR. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED PAX FLOOR SHEAR PLATE AT FRAME 17 NEAR SERVICE DOOR REF EMB SRM 51-40-02,51-40-08. RESTORED SURFACE PROTECTION REF EMB SRM 51-23-06. APPLIED CIC REFSDR SWIA202164590None · corrodedFS280 FWD FLOOR SUPPORT CORRODED. (C-CHECK RO 2/22/2022) REMOVED AND REPLACED THE FS. 280 COCKPIT FWD FLOOR SUPPORT WITH NEW REF. CRJ 700 SRM 51-42-06-001-001-A01, CRJ 700 SRM 51-42-21-001-001-A01, AND DWG #CC670-34010 REV. K. / COMPLIED WITH 51-900-SDR SWIA202164588None · corrodedLH FLOOR SILL FS 977.00- FS1000.00 HAS MULTIPLE LOCATIONS WITH CORROSION (C-CHECK RO 2/22/2022) REMOVED AND REPLACED LH FLOOR SILL AT FS985.00 TO FS1000.00. SEE CONT. CARD FOR FURTHER DETAILS. REF: CRJ700 SRM 51-42-06-001-001-A01, REO 670-53-61-2026, RSDR SWIA202164240None · elongatedL/H PRESSURE FLOOR SIL HAS ELONGATED NUTPLATE HOLE AT FS 424. (C CHECK RO 2-11-2022) COMPLIED WITH REPAIR OF L/H PRESSURE FLOOR SIL IAW MHIRJ REO 601R-53-41-2995 REV.-- DATED 2022-01-10. ATTACHED COMPLETED TASK CARD 51-900-1003-SKY AND COMPLETED FORM 337. SDR A6WA202101178074Door · crackedMAIN ENTRY DOOR HAS A CRACK ON THE FORWARD SIDE PANEL OF UPPER STEP FS320.10. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED DAMAGE OF MAIN ENTRY DOOR FORWARD SIDE PANEL OF UPPER STEP FS320.10, DIMENSIONS L= 12.00Ï¿½ X W= 6.00Ï¿½. FABRICATED 1 WEB REPLACEMENT LSDR SWIA202164411None · corrodedTHE FS280 CROSSBEAM HAS CORROSION AT RBL9 WHERE IT ATTACHES TO THE FLOOR PANEL SUPPORT ANGLE. (MARKED) (C-CHECK RO 2/16/2022) CORROSION FOUND TO BE OUT OF LIMITS REF. CRJ-900 SRM, 51-10-06-001-001-A01. REMOVED AND REPLACED CROSS BEAM FROM BL 0.0 TO RBSDR SWIA202164064None · failedRBL18 PRESSURE FLOOR BULKHEAD BEAM AT FS693 HAS AN INDICATION 20%FSH IN THE RADIUS OF THE VERTICAL FLANGE. FAILED NDT INSPECTION. (FILED CLOSED) REPLACED THE CRACKED RBL 18, FS 693 BULKHEAD BEAM WITH A NEW BEAM PN SH670-35886-6 IAW CRJ 700 SRM 51-42-21-0SDR YENA2021121600844Shear Tie · corrodedDURING HEAVY MAINTENANCE, CORROSION SHEAR TIE LOCATED AT FR 31 BTW DTR 43R AND 44R IN FWD CARGO COMPARTMENT; REMOVED AND REPLACED SHEAR TIE IAW SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2021-475473(CLASSIFIED A MAJOR REPAIR)SDR YENA2021121600843Shear Tie · corrodedDURING HEAVY MAINTENANCE, CORROSION SHEAR TIE LOCATED AT FR 32 BTW DTR 41R AND 42R IN FWD CARGO COMPARTMENT; REMOVED AND REPLACED SHEAR TIE IAW SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2021-475448 (CLASSIFIED A MAJOR REPAIR)SDR YENA2021121600842Shear Tie · corrodedDURING HEAVY MAINTENANCE, CORROSION SHEAR TIE LOCATED AT FR 31 BTW DTR 41R AND 42R IN FED CARGO COMPARTMENT; REMOVED AND REPLACED SHEAR TIE AT FR 31 BTW STR 41R AND 42R IN FWD CARGO COMPARTMENT IAW SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2021-475472 (CLSDR YENA2021121600839Shear Tie · corrodedDURING HEAVY MAINTENANCE, CORROSION SHEAR TIE LOCATED AT FR 32 BTW STR 40R AND 41R IN FWD CORDO COMP ; REMOVED AND REPLACED SHEAR TIE LOCATED FR 32 BTW STR 40R AND 41R IN FWD CARGO COMP IAW A320 SRM 51-72-11 WORK ACCOMPLISHED ON AEROMAN NR 20121-475447 (CONSIDSDR SWIA202164407None · corroded*CORROSION ON RH PRESSURE FLOOR SILL ANGLE BETWEEN FS 720.0 €“ 744.00. AREAS MARKED (C-CHECK RO 2/16/2022) REPAIRED RIGHT HAND PRESSURE FLOOR SILL ANGLE BETWEEN FS720.00 TO FS744.00 IAW REO 690-53-41-294 REV -- DATE 2021-12-23 STEPS. 1-9 (SEE CONTINUATSDR SWIA202164406None · corroded*CORROSION ON RH PRESSURE FLOOR SILL ANGLE BETWEEN FS 752.0 €“ 797.00. AREAS MARKED (C-CHECK RO 2/16/2022) REPAIRED RIGHTHAND PRESSURE FLOOR SILL ANGLE BETWEEN FS752.00 TO FS797.00 IAW REO 690-53-41-294 REV -- DATE 2021-12-23 STEPS.1-9 ( SEE CONTINUATISDR SWIA202164405None · corroded*CORROSION ON RH PRESSURE FLOOR SILL ANGLE BETWEEN FS 797.0 €“ 813.00. AREAS MARKED (C-CHECK RO 2/16/2022) REPAIRED RIGHT HAND PRESSURE FLOOR SILL ANGLE BETWEEN FS797.00 TO FS813.00 IAW REO 690-53-41-294 REV -- DATE 2021-12-23 STEPS.1-9 (SEE CONTINUATISDR SWIA202164404None · corroded*CORROSION ON LH PRESSURE FLOOR SILL ANGLE BETWEEN FS 797.0 €“ 752.00. AREAS MARKED (C-CHECK RO 2/16/2022) REPAIRED LEFTHAND PRESSURE FLOOR SILL ANGLE BETWEEN FS752.00 TO FS797.00 IAW REO 690-53-41-294 REV -- DATE 2021-12-23 STEPS. 1-9 COMPLIED WITH ALSDR SWIA202164403None · corroded*CORROSION ON LH PRESSURE FLOOR SILL ANGLE BETWEEN FS 708.0 €“ 752.00. AREAS MARKED (C-CHECK RO 2/16/2022) REPAIRED LEFTHAND PRESSURE FLOOR SILL ANGLE BETWEEN FS708.00 TO FS752.00 IAW REO 690-53-41-294 REV -- DATE 2021-12-23 STEPS. 1-9 (SEE CONTINUATIOSDR SWIA202164377None · corroded* THE MONUMENT FITTING BETWEEN FS364 AND FS379 AND BETWEEN LBL27 AND THE LH FLOOR SILL HAS CORROSION. (MARKED) (C-CHECK RO 2/16/2022) REMOVED AND REPLACED WITH NEW MONUMENT FITTING BETWEEN FS364 AND FS379 LBL27 AND LH FLOOR SILL REF CRJ900 SRM 51-42-06SDR SWIA202164375None · corroded* THE RH FLOOR SILL HAS MULTIPLE LOCATIONS OF CORROSION BETWEEN FS280 AND FS319. (MARKED) (C-CHECK RO 2/16/2022) REMOVED DAMAGE AND EVALUATED REPAIR. REPAIR FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED DAMAGED DOUBLER AND SILL. REF. CRJ900 SRM 51-42SDR SWIA202164058None · damagedDURING INCORPERATION OF SB 670-53-042 REV B WE FOUND HST11AG-5 HI-LITES AT FS 693 L/H AND R/H, FS 847 L/H AND R/H SILL DECKS WHERE SOLID RIVETS B0205001AD-5 RIVETS SHOULD BE. THE HI-LITES REQUIRE REMOVAL FOR FLOOR ACCESS, CLARIFICATION REQUIRED FOR REINSTALLASDR SWIA202164014None · elongatedFOUND MULTIPLE ELONGATED HOLES ON THE PRESSURE FLOOR DIAPHRAGM @ FS 801 AND RBL 36 PN SH670-36300-2. (FILED CLOSED) REMOVED AND REPLACED PRESSURE FLOOR DIAPHRAGM @ FS 801 AND RBL 36, IN REF. TO SRM 51-42-21, COMPLETED 51-900-1002-SKY AND M-337. REF. CP 23SDR SWIA202164144None · corrodedFLOOR BEAM AT STA 1031 LBL 27 IS CORRODED. (C CHECK RO 02-03-22) REPAIRED FLOOR BEAM AT STATION 1031 LBL 27 IAW CRJ 700 SRM 53-00-41-201-001-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA202164143None · corrodedFLOOR BEAM AT STA 1031 LBL 9 IS CORRODED. (C CHECK RO 02-03-22) REPAIRED FLOOR BEAM AT STA 1031 LBL 9 IAW CRJ700 SRM 53-00-41-201-001-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA202164057None · damagedWHILE ATTEMPTING TO PERFORM SB 670SH-53-042 PRESSURE FLOOR MOD 0N AC SN 10003 FOUND THE CONFIGURATIONOF THE LBL27 AND RBL27 FLOOR BEAMS AND BULKHEAD BEAMS BETWEEN FS693 & FS847DO NOT CONFORM TO ANY CONFIGURATION IN THE SERVICE BULLETIN. WILL REQUIRE ENGINEERISDR SWIA202164485None · corroded* PAX DOOR MID CAP ANGLE FLOOR SUPPORT CORRODED IN MULTIPLE SPOTS (MARKED). (C CHECK RO 2/17/2022) FOUND CORRODED MID CAP ANGLE OUT OF LIMIT ,REPLACED WITH NEW PN SH670-31825-9 PO# 10244-0015 REF CRJ 700 SRM 51-42-06-001-001-A01, SRM 51-41-02-001-001-A01 ASDR SWIA202164469None · corroded*BACKUP SILL CORRODED, STGR21L FS319.00 €“ FS333.00 (C CHECK RO 2/17/2022) REMOVED AND REPLACED CORRODED BACK UP SILL ON STGR21L BETWEEN FS319.00 AND FS333.00 WITH NEW BACK UP SILL (P/N SH670-31822-1) USING ALL NEW FASTENERS. REF BOMBARDIER DWG# SH670-31SDR SWIA202164350None · corrodedAFT CARGO DOOR FLOOR SILL HAS AREAS OF CORROSION. (C-CHECK RO 2/16/2022) REMOVED AND INSTALLED NEW AFT CARGO FLOOR SILL P/N: MM670-35655-003. REF CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-10-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01 AND DWG MSDR SWIA202164066None · brokenAFT BAGGAGE STEP PLATE STOPPER ASSYS, FWD AND AFT, FOUND TO BE BROKEN UPON REMOVAL. (FILED CLOSED) INSTALLED NEW AFT BAGGAGE STEP PLATE STOPPER ASSYS. FWD AND AFT IAW CRJ700 SRM 51-41-02SDR R61A2021120400979Shear Tie · corrodedCORROSION ON SHEAR CLIP FR 81 BETWEEN STRG 27R / 28R. REMOVED AND REPLACED SHEAR CLIP PN: 170-66885-001 REF EMB SRM 51-40-08, RESTORE FINISH REF EMB SRM 51-23-05 & 51-23-06. MAJOR REPAIRSDR R61A2021120400975Shear Tie · corrodedCORROSION ON SHEAR CLIP FR82 BETWEEN STGR 27R/28R. REMOVED AND REPLACED SHEAR CLIP PER SRM 51-40-08.SDR SWIA202164977None · damagedINSERT FOUND TO BE DAMAGED REQUIRES REPLACEMENT IN WARDROBE FRONT BOTTOM CORNER PLATE (C CHECK RO 3/11/2022) INSERT FOUND TO SERVICABLE AND FLOOR FITTING AND DOUBLER WERE FOUND CORRODED OUT OF LIMITS AND WERE REPLACED WITH NEW PARTS IAW C&D ZODIAC CMM 25-SDR SWIA202164134None · corrodedFS280 FLOOR BEAM HAS CORROSION ON FWD SIDE AT RBL4 (MARKED) (C CHECK RO 02-03-22) REMOVED AND REPLACED RH FS280 FLOOR BEAM REF DWG CC670-34010 REV -K CRJ 700 SRM 51-42-06-001-001-A01, AND CRJ 700 SRM 51-42-21-001-001-A01. COMPLIED WITH TASK CARD 51-900-10SDR SWIA202164133None · none*LH SIDE FUSELAGE FLOOR SILL AT APPROX. FS.533-FS.581 HAS MULTIPLE SPOTS OF CORROSION (MARKED) (C CHECK RO 02-03-22) BLENDED AND EVALUATED LH SIDE FUSELAGE FLOOR SILL AT APPROX. F.S 533-F.S 581, FOUND TO BE WITHIN LIMITS REF CRJ700 SRM 53-00-45-201-001-A0SDR SWIA202164231None · corrodedLH FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM FS.409.00+128 TO FS.529.00. (C CHECK RO 2-11-2022) REPAIRED LH FLOOR SILL MULITPLE SPOTS OF CORROSION FROM FS 409.00+128 TO FS 529.00 IAW BOMBARDIER REO 601R-53-41-666 REV C DATED 2012-11-06 AND SKY CARD 5SDR SWIA202164230None · corrodedRH FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM FS.424.00 TO FS.473.15. (C CHECK RO 2-11-2022) COMPLIED WITH BOMBARDIER REO 601R-53-41-666 REV-C DATED: 2012-11-06. COMPLIED WITH SKY CARD 51-900-1003-SKY AND 337 COMPLETED. WEIGHT AND BALANCE NOT EFFECTESDR SWIA202164269None · corrodedCROSSBEAM CAP AT FS 589 HAS MULTILE SPOTS OF CORROSION BETWEEN RBL24 AND RBL45 (C CHECK RO 2-11-2022) REMOVED AND REPLACED CROSSBEAM CAP AT FS 589 RBL24 - RBL 45 IAW CRJ 200 SRM 51-42-15 AND SRM 51-42-06SDR SWIA202164268None · corrodedCROSSBEAM CAP AT FS 589 HAS MULTIPLE SPOTS OF CORROSION BETWEEN LBL 9 AND LBL 27 (C CHECK RO 2-11-2022) REMOVED AND REPLACED CROSSBEAM CAP AT FS 589 BETWEEN LBL9 AND LBL27 IAW CRJ 200 SRM 51-42-06, CRJ 200 SRM 51-42-21, AND CRJ 200 SRM 51-40-11SDR SWAA2022010647564Shear Tie · crackedFOUND SHEAR TIE CRACKED AT FLIGHT DECK STA 225 RBL 40 ; / [01] INSTALLED EWS PROTECTION AT FLIGHT DECK R/H SIDE BETWEEN STA 220 AND STA 230 REF B737-700 AMM 20-60-07-913-801.; [02] REMOVED DAMAGE SHEAR TIE AT FLIGHT DECK R/H SIDE BETWEEN STA 219.8 AND STA 224.SDR SWIA202163271None · corrodedRH FLOOR SILL BETWEEN FS 280-FS319.70 HAS SEVERAL SPOTS OF CORROSION (C-CHECK RO 12/26/2021) INSTALLED NEW RH FLOOR SILL BETWEEN FS 280-FS319.70 REF CRJ700 SRM 51-42-06-001-001-A01, CRJ700 SRM 51-42-13-001-001-A01, CRJ700 SRM 51-42-21-001-001-A01 AND DSDR SWIA202163980None · corroded* RH FLOOR SILL CORRODED AT APROX. FS.319.7 (MARKED). (C-CHECK RO 1/19/2022) CORROSION FOUND TO BE OUT OF LIMITS. REPLACED RH FLOOR SILL AT FS280 - FS319 REF CRJ-900 SRM 51-42-06-001-001-A01, CRJ-900 SRM 51-42-13-001-001-A01, CRJ-900 SRM 51-42-21-001-00
Back to JASC 5322