JASC 5340
Service difficulty reports · 22,411
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA000593Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND DAMAGE TO BULKHEAD FITTING ON O/B SIDE AT STA 8 AND LONGERON 33 LEFT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DSDR RRXA002337Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME ATTACH ANGLE TO FWD RT OVERWING EXIT DOOR AT FS 717 - 740 AND L19R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING SDR RRXA002373Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE IN THE MAIN CABIN INTERIOR AT STA 1586 AND L31L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-SDR USAA000325Gusset · crackedCLT - FOUND NOSE GEAR CRACKED 1.5 INCH, STATION 277 NOSE GEAR ACTUATOR ATTACH GUSSET. REMOVED CRACKED GUSSETT REPLACED WITH NEW PART PER DWG 65-45819. (M)SDR RRXA002332Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM TO FRAME ATTACH ANGLE AT STA 1586 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-3-SDR RRXA003411Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE C-PIT TORQUE BOX BATHTUB FITTING AT FS 1180 AND L35R TO L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-0SDR AALA2000496Spring · bentTUL - FOUND LOWER PIN SPRING BENT AND DISCONNECTED FROM TAIL CONE JETTISION. REPLACED BENT SPRING WITH NEW SPRING MM 53-53-00-5-1. (M)SDR RRXA000614Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION TO THE BATH TUB FITTING AT STA 340 AND LONGERON 35R TO 34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D. (CORROSSDR RRXA000613Attach Fitting · corrodedDURING A MAINTANANCE VISIT, FOUND CORROSION DAMAGE TO THE BATH TUB FITTING AT STA 320 AND LONGERON 36 TO 35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTING IAW DC-8 SRM 51-1-20D. (CORROSION DAMASDR RRXA000612Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE BATH TUB FITTING AT STA 300 AND LONGERON 34R TO OCL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20SDR RRXA000608Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BATH TUB FITTING AT STA 300 AND LONGERON 35R TO 34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20DSDR RRXA000924Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 798 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED FITTING FROM 7075-T6 AND INSTALLED PER DOUGLAS DWG #SDR RRXA000922Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 781 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED ATTACH FITTING IAW DC-8 SRM 51-3-0 AND 51-1-20D.SDR RRXA000853Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND A HOLE DRILLED IN TERMINAL LUG FITTING FWD. AT STA 857 AND LONGERON 21RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 51-3-0.SDR RRXA000672Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTING AT STA 1280 AND LONGERON 33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW ATTACH FITTING AND INSTALLED IAW DC-8 SRM 51-1-SDR RRXA001693Attach Angle · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL TO BEAM ATTACH ANGLE AT STA 270 LT AND LBL 46 Z-AXIS 1INCH, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE FROM 7075-T6SDR RRXA000852Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING WHEEL WELL UPPER SURFACE AT STA 977 TO 980 LT. Z AXIS -9, LBL +25 LT., DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000851Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING WHEEL WELL UPPER SURFACE BETWEEN STA 960 TO 980 LT. Z AXIS -9, LBL +27 TO 39, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000541Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT LONGERON 24 RIGHT FITTING AND STA 960. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D. CSDR RRXA001700Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND A POSSIBLE CRACK AT THE RT WHEEL WELL ATTACH FITTING AT STA 960 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLESDR RRXA000954Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE BATH TUB FITTING AT STA 1530 AND L24 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM 51-1-21 AND 51-1-20D.SDR RRXA000939Attach Angle · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH ANGLES IN THE UPPER CARGO COMPT. FS 400 TO 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLES FROM 7075-T6 AND SDR RRXA000936Attach Angle · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH ANGLES AT FUSELAGE STA 460 TO 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE FROM 7075-T6 AND INSTALLED IAW DSDR RRXA000535Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 190 AND LONGERON 21 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEVIED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D. CORROSION RSDR RRXA000531Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 280 AND LONGERON 30 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 FIGURE 2D.SDR RRXA002331Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE IN THE MAIN CABIN INTERIOR FRAME AT STA 900 AND L11L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SSDR RRXA000664Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK AT THE FLOORBEAM ATTACH FITTING AT STA 70 BBL 55, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-1-20 AND DAC DWG 4888829.SDR RRXA000534Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 300 AND LONGERON 32 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DAC DWG 3755826. CORROSION DASDR RRXA001516Attach Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND A DRILLED HOLE IN THE FUSELAGE. STRUCTURE FLOORBEAM ATTACH FITTING AT UPPER LEG IN RADIUS OF STA 702 LBL +23, AXIS 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND SDR RRXA000522Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 1150 BETWEEN LONGERONS 34 RIGHT TO 35 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DCSDR USAA000197Attach Angle · crackedCLT - FOUND ATTACH ANGLE CRACKED .75 INCH, STATION 290, WL 249 RIGHT SHEAR WEB OUTBOARD. REPAIRED PER SRM 51-40-02. (M)SDR USAA000198Attach Angle · crackedCLT - FOUND ATTACH ANGLE CRACKED .75 INCH, STATION 290, WL 241 RIGHT SHEAR WEB OUTBOARD. REPAIRED PER SRM 51-40-02. (M)SDR RRXA000515Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 31 LEFT SPLICE FITTING BETWEEN STA 440 TO STA 450. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE FITTING IAW DAC SDR RRXA001699Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND POSSIBLE CRACK ON THE ATTACH FITTING AT STA 940 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW ATTACH FITTING AND INSTALLED IAW DC-SDR RRXA000528Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM FITTING AT STA 1660 AND BL 63 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DC-8 SRM 53-1-0. CORROSSDR RRXA000862Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE IN THE LT WHEEL WELL AT STA 940 AND LONGERON 24 LT. ON LONGERON 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 5SDR RRXA000867Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE VERTICAL STIFFNER AT STA 188 AND RBL 69 Z AXIS -10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PLATE & SHIM FROM 2024-T3 AND INSTASDR RRXA000642Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE ATTACH FITTING AT STA 1140 AND LONGERON 35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG NR SDR RRXA000503Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 879 AND LONGER 24 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 53-2-0 FIGURE 8. CORROSION DAMAGE SDR RRXA002327Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE WEB ATTACH FITTING AT FS 1400 AND L21R FRAME TO PRESS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-20D, 5SDR RRXA000923Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 759 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ATTACH FITTING IAW DC-8 SRM, 51-3-0 AND 51-1-20SDR RRXA000502Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BULKHEAD ATTACHMENT FITTING AT STA 8 AND LONGERON 33 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DAC DWG 461SDR RRXA001515Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FITTING AT THE PRODUCTION BREAK AT STA 680 - 700 AND LONG 11 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ATTACH FITTING IAW DC-8 SRM 51SDR RRXA000855Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FRAME TO LONGERON ATTACH FITTING AT FRAME AT STA 680 LT. AND LONGERON 11 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED LONGERON ATTACH FSDR RRXA000850Attach Fitting · gougedDURING A MAINTENANCE VISIT, FOUND A GOUGE TO THE UPPER CARGO COMPT MAIN CARGO DOOR FLOORBEAM ATTACH PLATE AT STA 400 TO XCW 64L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW ATTACH PLATSDR RRXA000634Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FRAME ATTACH FITTING AFT OF FRAME AT STA 680 LONGERON 11R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-3-0.SDR CA000209009Fitting · cracked(CAN) PART CRACKED BEYOND LIMITS.SDR ASAA0080071Fitting · corrodedPHX - DURING 30K CHECK, FOUND CORROSION ON FRAME FITTING AT FS 1136, RBL 60. REMOVED DAMAGED MATERIAL AND INSTALLED NEW PIECES IAW DC9 SRM 51-30. (M)SDR DHL200080336CShear Tie · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT SKIN FRAME ATTACH ANGLE CRACKED 3 INCHES STA 1380 L-31 TO L-32. FABRICATED DOUBLER IAW SRM 53-2-0, INSTALLED DOUBLER IAW 51-1-21 PG 7, FIG 33B. N/R 5610SDR RRXA002957Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE ATTACH ANGLE AT STA 1220 AND LONGERON X-45, Z-6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORR
Back to JASC 5340