JASC 5340

Service difficulty reports · 22,411

Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5340'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA000593Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND DAMAGE TO BULKHEAD FITTING ON O/B SIDE AT STA 8 AND LONGERON 33 LEFT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DMar 14, 2000 · N831AL · Doug DC873FSDR RRXA002337Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME ATTACH ANGLE TO FWD RT OVERWING EXIT DOOR AT FS 717 - 740 AND L19R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING Mar 13, 2000 · N995CF · Doug DC862SDR RRXA002373Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE IN THE MAIN CABIN INTERIOR AT STA 1586 AND L31L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-Mar 10, 2000 · N995CF · Doug DC862SDR USAA000325Gusset · crackedCLT - FOUND NOSE GEAR CRACKED 1.5 INCH, STATION 277 NOSE GEAR ACTUATOR ATTACH GUSSET. REMOVED CRACKED GUSSETT REPLACED WITH NEW PART PER DWG 65-45819. (M)Mar 7, 2000 · N512AU · Boeing 7373B7SDR RRXA002332Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM TO FRAME ATTACH ANGLE AT STA 1586 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-3-Mar 6, 2000 · N995CF · Doug DC862SDR RRXA003411Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE C-PIT TORQUE BOX BATHTUB FITTING AT FS 1180 AND L35R TO L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-0Mar 3, 2000 · N831AL · Doug DC873FSDR AALA2000496Spring · bentTUL - FOUND LOWER PIN SPRING BENT AND DISCONNECTED FROM TAIL CONE JETTISION. REPLACED BENT SPRING WITH NEW SPRING MM 53-53-00-5-1. (M)Mar 2, 2000 · N287AA · Doug DC982SDR RRXA000614Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION TO THE BATH TUB FITTING AT STA 340 AND LONGERON 35R TO 34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D. (CORROSMar 1, 2000 · N831AL · Doug DC873FSDR RRXA000613Attach Fitting · corrodedDURING A MAINTANANCE VISIT, FOUND CORROSION DAMAGE TO THE BATH TUB FITTING AT STA 320 AND LONGERON 36 TO 35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTING IAW DC-8 SRM 51-1-20D. (CORROSION DAMAMar 1, 2000 · N831AL · Doug DC873FSDR RRXA000612Attach Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE BATH TUB FITTING AT STA 300 AND LONGERON 34R TO OCL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20Mar 1, 2000 · N831AL · Doug DC873FSDR RRXA000608Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BATH TUB FITTING AT STA 300 AND LONGERON 35R TO 34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20DMar 1, 2000 · N831AL · Doug DC873FSDR RRXA000924Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 798 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED FITTING FROM 7075-T6 AND INSTALLED PER DOUGLAS DWG #Feb 29, 2000 · N994CF · Doug DC862SDR RRXA000922Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 781 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED ATTACH FITTING IAW DC-8 SRM 51-3-0 AND 51-1-20D.Feb 29, 2000 · N994CF · Doug DC862SDR RRXA000853Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND A HOLE DRILLED IN TERMINAL LUG FITTING FWD. AT STA 857 AND LONGERON 21RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 51-3-0.Feb 29, 2000 · N994CF · Doug DC862SDR RRXA000672Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTING AT STA 1280 AND LONGERON 33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW ATTACH FITTING AND INSTALLED IAW DC-8 SRM 51-1-Feb 27, 2000 · N831AL · Doug DC873FSDR RRXA001693Attach Angle · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL TO BEAM ATTACH ANGLE AT STA 270 LT AND LBL 46 Z-AXIS 1INCH, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE FROM 7075-T6Feb 25, 2000 · N994CF · Doug DC862SDR RRXA000852Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING WHEEL WELL UPPER SURFACE AT STA 977 TO 980 LT. Z AXIS -9, LBL +25 LT., DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.Feb 25, 2000 · N994CF · Doug DC862SDR RRXA000851Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING WHEEL WELL UPPER SURFACE BETWEEN STA 960 TO 980 LT. Z AXIS -9, LBL +27 TO 39, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.Feb 25, 2000 · N994CF · Doug DC862SDR RRXA000541Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT LONGERON 24 RIGHT FITTING AND STA 960. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D. CFeb 25, 2000 · N831AL · Doug DC873FSDR RRXA001700Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND A POSSIBLE CRACK AT THE RT WHEEL WELL ATTACH FITTING AT STA 960 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLEFeb 24, 2000 · N994CF · Doug DC862SDR RRXA000954Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE BATH TUB FITTING AT STA 1530 AND L24 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM 51-1-21 AND 51-1-20D.Feb 24, 2000 · N994CF · Doug DC862SDR RRXA000939Attach Angle · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH ANGLES IN THE UPPER CARGO COMPT. FS 400 TO 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLES FROM 7075-T6 AND Feb 24, 2000 · N994CF · Doug DC862SDR RRXA000936Attach Angle · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH ANGLES AT FUSELAGE STA 460 TO 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE FROM 7075-T6 AND INSTALLED IAW DFeb 24, 2000 · N994CF · Doug DC862SDR RRXA000535Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 190 AND LONGERON 21 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEVIED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D. CORROSION RFeb 24, 2000 · N831AL · Doug DC873FSDR RRXA000531Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 280 AND LONGERON 30 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 FIGURE 2D.Feb 23, 2000 · N831AL · Doug DC873FSDR RRXA002331Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE IN THE MAIN CABIN INTERIOR FRAME AT STA 900 AND L11L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SFeb 22, 2000 · N995CF · Doug DC862SDR RRXA000664Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK AT THE FLOORBEAM ATTACH FITTING AT STA 70 BBL 55, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-1-20 AND DAC DWG 4888829.Feb 22, 2000 · N831AL · Doug DC873FSDR RRXA000534Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 300 AND LONGERON 32 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DAC DWG 3755826. CORROSION DAFeb 22, 2000 · N831AL · Doug DC873FSDR RRXA001516Attach Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND A DRILLED HOLE IN THE FUSELAGE. STRUCTURE FLOORBEAM ATTACH FITTING AT UPPER LEG IN RADIUS OF STA 702 LBL +23, AXIS 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND Feb 18, 2000 · N994CF · Doug DC862SDR RRXA000522Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 1150 BETWEEN LONGERONS 34 RIGHT TO 35 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DCFeb 18, 2000 · N831AL · Doug DC873FSDR USAA000197Attach Angle · crackedCLT - FOUND ATTACH ANGLE CRACKED .75 INCH, STATION 290, WL 249 RIGHT SHEAR WEB OUTBOARD. REPAIRED PER SRM 51-40-02. (M)Feb 15, 2000 · N425US · Boeing 737401SDR USAA000198Attach Angle · crackedCLT - FOUND ATTACH ANGLE CRACKED .75 INCH, STATION 290, WL 241 RIGHT SHEAR WEB OUTBOARD. REPAIRED PER SRM 51-40-02. (M)Feb 15, 2000 · N425US · Boeing 737401SDR RRXA000515Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 31 LEFT SPLICE FITTING BETWEEN STA 440 TO STA 450. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE FITTING IAW DAC Feb 15, 2000 · N831AL · Doug DC873FSDR RRXA001699Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND POSSIBLE CRACK ON THE ATTACH FITTING AT STA 940 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW ATTACH FITTING AND INSTALLED IAW DC-Feb 11, 2000 · N994CF · Doug DC862SDR RRXA000528Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM FITTING AT STA 1660 AND BL 63 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DC-8 SRM 53-1-0. CORROSFeb 11, 2000 · N831AL · Doug DC873FSDR RRXA000862Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE IN THE LT WHEEL WELL AT STA 940 AND LONGERON 24 LT. ON LONGERON 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 5Feb 10, 2000 · N994CF · Doug DC862SDR RRXA000867Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE VERTICAL STIFFNER AT STA 188 AND RBL 69 Z AXIS -10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PLATE & SHIM FROM 2024-T3 AND INSTAFeb 9, 2000 · N994CF · Doug DC862SDR RRXA000642Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE ATTACH FITTING AT STA 1140 AND LONGERON 35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-1-20D AND DAC DWG NR Feb 9, 2000 · N831AL · Doug DC873FSDR RRXA000503Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 879 AND LONGER 24 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 53-2-0 FIGURE 8. CORROSION DAMAGE Feb 9, 2000 · N831AL · Doug DC873FSDR RRXA002327Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE WEB ATTACH FITTING AT FS 1400 AND L21R FRAME TO PRESS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-20D, 5Feb 8, 2000 · N995CF · Doug DC862SDR RRXA000923Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 759 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ATTACH FITTING IAW DC-8 SRM, 51-3-0 AND 51-1-20Feb 8, 2000 · N994CF · Doug DC862SDR RRXA000502Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BULKHEAD ATTACHMENT FITTING AT STA 8 AND LONGERON 33 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DAC DWG 461Feb 8, 2000 · N831AL · Doug DC873FSDR RRXA001515Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FITTING AT THE PRODUCTION BREAK AT STA 680 - 700 AND LONG 11 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ATTACH FITTING IAW DC-8 SRM 51Feb 7, 2000 · N994CF · Doug DC862SDR RRXA000855Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FRAME TO LONGERON ATTACH FITTING AT FRAME AT STA 680 LT. AND LONGERON 11 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED LONGERON ATTACH FFeb 3, 2000 · N994CF · Doug DC862SDR RRXA000850Attach Fitting · gougedDURING A MAINTENANCE VISIT, FOUND A GOUGE TO THE UPPER CARGO COMPT MAIN CARGO DOOR FLOORBEAM ATTACH PLATE AT STA 400 TO XCW 64L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW ATTACH PLATJan 31, 2000 · N994CF · Doug DC862SDR RRXA000634Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FRAME ATTACH FITTING AFT OF FRAME AT STA 680 LONGERON 11R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC-8 SRM 51-3-0.Jan 30, 2000 · N831AL · Doug DC873FSDR CA000209009Fitting · cracked(CAN) PART CRACKED BEYOND LIMITS.Jan 28, 2000 · Lkheed 1329SDR ASAA0080071Fitting · corrodedPHX - DURING 30K CHECK, FOUND CORROSION ON FRAME FITTING AT FS 1136, RBL 60. REMOVED DAMAGED MATERIAL AND INSTALLED NEW PIECES IAW DC9 SRM 51-30. (M)Jan 26, 2000 · N958AS · Doug DC983SDR DHL200080336CShear Tie · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT SKIN FRAME ATTACH ANGLE CRACKED 3 INCHES STA 1380 L-31 TO L-32. FABRICATED DOUBLER IAW SRM 53-2-0, INSTALLED DOUBLER IAW 51-1-21 PG 7, FIG 33B. N/R 5610Jan 25, 2000 · N803DH · Doug DC873FSDR RRXA002957Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE ATTACH ANGLE AT STA 1220 AND LONGERON X-45, Z-6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORRJan 20, 2000 · N792FT · Doug DC873F
Back to JASC 5340