SDR UPS04M42090Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STABILIZER RIGHT NR 19 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL & BEARING SURFACE. CORROSION AT BOTTOM OF RIGHT NR 19 HOLE REMOVED PER SRM 51-21-01 VOL 2 REV 34. MATERIAL REMOVED 0.079 INCH. BARREL NUT HOLE REPAIR SDR UPS04M42082Structure · corrodedINSPECTION TYPE:C HORIZONTAL STABILIZER RIGHT NR 22 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL & BEARING SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 AT HOLE BOTTOM SURFACE, MATERIAL REMOVED 0.063 INCH. BARREL NUT HOLE REPAIRED PER EN104SDR UPS04M42301Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STABILIZER RT NR 6 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING AND SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.056. BARREL NUT HOLE REPAIRED PER EN 1034-004 (REF UPS ENGINEERINGSDR UPS04841951Bearing · corrodedINSPECTION TYPE: C3, LEFT HORIZONTAL STAB HINGE BEARING WILL NOT ACCEPT GREASE. DISASSEMBLED HINGE. FOUND STAB BEARING BORE CORRODED. REPAIRED PER SAA SK 703-677 AND UPS EO DC8-5510-19991-A.SDR CALA0400110Strap · lightning strikeINSPECTION FOUND RIGHT O/B HORIZONTAL STABILIZER TRAILING EDGE STRAP WITH EVIDENCE OF A LIGHTNING STRIKE. THE AFT O/B UPPER TRAILING EDGE STRAP WAS REMOVED AND REPLACED IAW SRM 51-40-02. THE FIBERGLASS UNDERNEATH WAS REPAIRED IAW SRM 51-70-08 AND 51-21-101-7SDR UPS04M42086Structure · corrodedINSPECTION TYPE:C HORIZONTAL STABILIZER LEFT NR 01 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL & BEARING SURFACE. CORROSION REMOVED AT HOLE BOTTOM SURFACE PER SRM 51-21-01 VOL 2 REV 34, MATERIAL REMOVED 0.094 INCH. BARREL NUT HOLE REPAIRED PER EN1033SDR UPS04M42081Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STABILIZER RIGHT NR 36 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, SIDEWALL & BEARING SURFACE. CORROSION REMOVED AT HOLE BOTTOM SURFACE PER SRM 51-21-01 VOL 2 REV 34, MATERIAL REMOVED 0.124 INCH. BARREL NUT HOLE REPAIR PER EN103SDR UPS04M42303Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STABILIZER RT NR 2 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.014. BARREL NUT HOLE REPAIRED PER EN 1028-04 (REF UPS ENGINEERING FILESDR UPS04M42299Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 32 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING AND SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.070 INCH. BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409-D. BARRESDR UPS04M42290Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB RT NR 32 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL2 REV34 MATERIAL REMOVED 0.034. BARREL NUT HOLE REPAIRED PER EN 1019-04. BUSHING FABRICATED & INSTALLEDSDR UPS04M42288Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB RT NR 35 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & S IDEWALL SURFACE. CORROSION REMOVED PER SRM 51-2101 VOL2 REV34 MATERIAL REMOVED 0.0716. BARREL NUT HOLE REPAIRED PER EN 1016-04. BUSHING FABRICATED & INSTALLEDSDR UPS04M42287Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 23 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING AN D SIDEWALL SURFACE. CORRSION REMOVED AT HOLE BOTTOM SURFACE PER SRM 51-21-01 VOL2 REV34 MATE RIALS REMOVED 0.093 INCH. BARREL NUT HOLE REPAIR PER EN 1024-04. SDR UPS04M42286Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 29 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING AN D SIDEWALL SURFACE. CORROSION REMOVED AT BOTTOM SURFACE MATERIALS REMOVED 0.050 INCH FOUND WITHIN LIMIT PER EO MD11-5510-19409D. 2)BARREL NUT HOLE REPAIRED PESDR UPS04M42269Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB RT NR 29 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING AND SIDEWALL SURFACE. CORROSION REMOVED AT NR 29 HOLE BOTTOM PER SRM 51-21-01 VOL II REV 34 , MATERIAL REMOVED 0.027 FOUND WITHIN LIMIT AS PER EO MD11-5510-1940SDR UPS04M42091Structure · corrodedINSPECTION TYPE:C HORIZONTAL STABILIZER RIGHT NR 20 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 AT HOLE BOTTOM, SURFACE MATERIAL REMOVED 0.019 INCH. BARREL NUT HOLE REPAIR PER EN1022-SDR UPS04M42085Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STABILIZER RIGHT NR 26 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 AT HOLE BOTTOM SURFACE AREA MATERIAL REMOVED 0.105 INCH. BARREL NUT HOLE REPAIRED PESDR UPS04M42083Structure · corrodedINSPECTION TYPE:C HOZIZONTAL STABILIZER LEFT NR 26 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING AND SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 AT HOLE BOTTOM, SURFACE MATERIAL REMOVED 0.071 INCH. BARREL NUT HOLE REPAIR PER EN 102SDR UPS04M42080Structure · corrodedINSPECTION TYPE:C HORIZONTAL STABILIZER RIGHT NR 23 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED AT HOLE BOTTOM SURFACE, MATERIAL REMOVED 0.064 INCH PER SRM 51-21-01 VOL 2 REV 34. CARRY OUT BARREL NUT HOLE REPAIR PSDR UPS04M42305Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 02 BARREL NUT HOLES FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.006. BARREL NUT HOLE REPAIRED PER EN 1011-04 (REF UPS ENGINEERING FILE NR SDR UPS04M42304Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 14 BARREL NUT HOLE, FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.007. FITTING FABRICATED & INSTALLED PER EN 1015-04 (REF UPS ENGINEERING FSDR UPS04M42300Structure · corrodedINSPECTION TYPE:C HORIZONTAL STAB LT NR 11 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL2 REV34 MATERIAL REMOVED 0.030. BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409-D. BARREL NUT HOLE RSDR UPS04M42298Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 8 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.006 INCH. BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409-D. BARREL SDR UPS04M42297Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 05 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & S IDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL 2 REV 34 MATERIAL REMOVED 0.0006 INCH. BUSHING FABRICATED & INSTALLED PER EO MD11-5510-19409-D. BARRELSDR UPS04M42291Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB LT NR 17 BARREL NUT HOLE FOUND WITH CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED PER SRM 51-21-01 VOL2 REV34 MATERIAL REMOVED 0.054. BARREL NUT HOLE REPAIRED PER EN 1026-04. BUSHING FABRICATED & INSTSDR UPS04M42270Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB RT NR 11 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE. CORROSION REMOVED AT NR 11 HOLE BOTTOM SURFACE PER SRM 51-21-01 VOL II REV 34, MATERIAL REMOVED 0.030 FOUND WITHIN LIMIT PER EO MD11-5510-194SDR UPS04M42267Structure · corrodedINSPECTION TYPE: C, HORIZONTAL STAB RT NR 8 BARREL NUT HOLE FOUND CORROSION ON BOTTOM, BEARING & SIDEWALL SURFACE HOLE BOTTOM SURFACE AREA CORROSION REMOVED PER SRM51-21-01 VOL II R EV 34, MATERIAL REMOVED 0.005 INCH FOUND WITHIN LIMIT PER EO MD11-5510-194 09SDR SIMA200404601Bushing · wornDURING SCHEDULED MAINTENANCE, FOUND HORIZONTAL STAB HAS PLAY AT RIGHT AFT HINGE MOUNT PIN. REPAIRED HORIZONTAL STAB REAR MOUNT BUSHING IAW EMB 145 SRM 55-10-02. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 04FDEA00308Hinge · misalignedRIGHT HORIZONTAL STABILZER SLOT DOOR 344AB FASTENER HOLES FOUND MISALIGNED. RT HORIZONTAL STAB SLOT DOOR 344AB FASTENER HOLES MISALIGN AREA CARRIED OUT REPAIR IAW EA 1-5510-74301, STABILIZERS - HORIZONTAL STABILIZER - RT NR 1 SLOT DOOR ASSEMBLY REPAIR.SDR 04FDEA00288Structure · corrodedTAIL TANK, TO ACCOMPLISH E1-5510-7-5000 PT 1. LT NR 36 BARREL NUT HOLE CORROSION REMOVAL, WEB CUTTING REQUIRE FOR ACCESS. HORIZONTAL STABILIZER, TAIL TANK, WEB CUT OUT FOR ACCESS OF LT NR 36 BARREL NUT HOLE. CORROSION REMOVAL AND REPAIR CARRIED OUT AS PSDR UPS04M42084Structure · corrodedINSPECTION TYPE:C HORIZONTAL STABILIZER BARREL RIGHT NR 01 NUT HOLE FOUND CORROSION ON BARREL NUT BEARING SURFACE (FWD & AFT) AND BOTTOM EDGE. CORROSION REMOVED AT NR 1 HOLE RIGHT BOTTOM SURFACE PER SRM 51-21-01 VOL 2 REV 34, MATERIAL REMOVED 0.060 INCH. BARSDR DL73S040101Fitting · corrodedDURING INSPECTION AND REWORK OF THE HORIZONTAL STABILIZER LUGS, SEVERAL LUGS WERE REWORKED BEYOND PUBLISHED LIMITS. CORROSION REMOVED AND LUGS REWORKED IAW ERA 386090-14AD.SDR CA040120009Block · worn(CAN) DURING C CHECK, ONE RUB BLOCK (P/N 69-31604-4) WAS FOUND LOOSE ON THE LOWER BEAM. AFTER REMOVAL OF THE BLOCK, IT WAS FOUND THAT THE LOWER BEAM WAS WORN OUT OF LIMIT AT THE PLACE WHERE THE RUB BLOCK WAS INSTALLED. THE LOWER BEAM HAS TO BE REPLACED.SDR 2004FA0000076Stiffener · crackedCRACKS IN TWO STIFFENERS AT HORIZONTAL STABILIZER SPAR, ONE RT SIDE OF FUSELAGE ABOVE THE SPAR. THE OTHER IN HORIZONTAL STIFFENER LOWER LEFT SIDE. FOUND WHILE INSPECTING IAW SPECIAL AIRWORTHINESS INFORMATION BULLETIN NR CE-04-34.SDR COOSDR030068Beam · corrodedLT HORIZONTAL STABILIZER, TRAILING EDGE, UPPER BEAM CORRODED.SDR COOSDR030056Web · wornRT HORIZONTAL STABILIZER TRAILING EDGE, HINGE RIB, WEB WITH WEAR.SDR COOSDR030055Seal · crackedLT HORIZONTAL STABILIZER BLADE SEAL CRACKED.SDR 03FDEA02338Structure · corrodedHORIZONTAL STABILIZER LEFT UPPER AFT SPAR CAP 36L BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATION. COMPLIED WITH FEDEX EA 1-5510-7522, HORIZONTAL STABILIZER BARREL NUT BORE REWORK / REPAIR / A.D. 2003-22-08.SDR 03FDEA02325Structure · corrodedHORIZONTAL STAB LT UPPER FWD PLANK NR 14L BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATIONS. COMPLIED WITH FEDEX EA 1-5510-75204: HORIZONTAL STABILIZER BARREL NUT BORE 14 LH FITTING FABRICATION.SDR 03FDEA02320Structure · corrodedHORIZONTAL STAB RT UPPER CENTER PLANK NR 26R BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATION. COMPLIED WITH FEDEX EA 1-5510-75197: HORIZONTAL STAB BARREL NUT BORE 26 RT FITTING FABRICATION.SDR 03FDEA02318Structure · corrodedHORIZONTAL STAB LT UPPER CENTER PLANK NR 26L BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATION. COMPLIED WITH FEDEX EA 1-5510-75196: HORIZONTAL STAB BARREL NUT BORE 26 LT FITTING FABRICATION.SDR 03FDEA02317Structure · corrodedHORIZONTAL STAB LT UPPER CENTER PLANK NR 18L BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATION. COMPLIED WITH FEDEX EA 1-5510-7522, HORIZONTAL STAB BARREL NUT BORE REWORK / REPAIR / A.D. 2003-22-08.SDR 03FDEA02316Structure · corrodedHORIZONTAL STAB RT UPPER AFT PLANK 30R BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATION. COMPLIED WITH FEDEX EA 1-5510-7522, HORIZONTAL STAB BARREL NUT BORE REWORK / REPAIR / A.D. 2003-22-08.SDR 03FDEA02315Structure · corrodedHORIZONTAL STAB LT UPPER CENTER PLANK 25L BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATION. COMPLIED WITH FEDEX EA 1-5510-75222, HORIZONTAL STAB BARREL NUT BORE REWORK / REPAIR / A.D. 2003-22-08.SDR 03FDEA02314Structure · corrodedHORIZONTAL STAB LT UPPER CENTER PLANK 15L BARREL NUT BORE CORROSION FOUND EXCEEDED EO 1-5510-7-5000 LIMITATION. COMPLIED WITH FEDEX EA 1-5510-75222, HORIZONTAL STAB BARREL NUT BORE REWORK / REPAIR / A.D. 2003-22-08.SDR DL73S031131Attach Fitting · corrodedCORROSION WAS NOTED DURING INSPECTION OF THE HORIZ STAB ATTACH LUGS PER 03-069697-03 AND 03-053025-03AD. THE RIGHT SIDE OUTBOARD HORIZ STAB REAR SPAR UPPER ATTACH LUG WAS BEYOND PUBLISHED ALLOWABLE LIMITS. CORROSION WAS REMOVED AND LUG REWORKED PER ERA 38598SDR CA031212005Bracket · cracked(CAN) AN INSPECTION WAS PERFORMED TO THE BRACKET AT THE REAR OF THE HORIZONTAL STABILIZER IN PREPARATION FOR COMPLIANCE WITH CESSNA SERVICE BULLETIN 03-6.ONCE THE STABILIZER AND BRACKET WERE REMOVED FROM THE AIRCRAFT, A CLOSE VISUAL EXAMINATION REVEALED A CRACSDR CA031210005Attach Fitting · cracked(CAN) DURING ANNUAL INSPECTION THE RT HORIZONTAL STABILIZER AUX FIN WAS FOUND TO BE LOOSE. UPON INVESTIGATION BY MAINTENANCE PERSONNEL THE FORWARD STABILZER BRACE AND AUX FIN ATTACH PLATE P/N 30653-2 WAS FOUND CRACKED COMPLETELY THROUGH AND AFT STABILIZER BRACSDR CALA0300685Bushing · corrodedCORROSION ON FORWARD LOWER HORIZONTAL STAB CENTER SECTION LUG ON AFT CLEVIS ON AFT FACE AT BUSHING. REMOVED AND REPLACED BUSHING PER SOPM 20-50-03.SDR DHL2003742553Structure · wornDURING C-CHECK, LOWER RUDDER L/E WORE-OUT LT AND RT SIDES/CHAFING AREAS. REMOVED LWR RUDDER FOR ACCESS IAW B-727 MM 27-20-1. REMOVED 2 EACH PREVIOUS REPAIR AND FABBED NEW FROM 301 1/4 HD .016 PO 3348 101 DIM 21.5 X 11 INCH AND 21.5 X 11.375 INCH IAW B-727 SRSDR 03FDEA01991Structure · corrodedHORIZONTAL STAB RIGHT UPPER AFT PLANK NR 27R BARREL NUT BORE FOUND CORROSION EXCEEDED EO LIMITATION. HOR STAB RH UPPER AFT PLANK 27R BARREL NUT BORE REPAIR CARRIED OUT AS PER EA 1- 5510-74245 STABILIZERS - HORIZONTAL STABILIZER - BARREL NUT BORE REWORK / R
Back to JASC 5510