Airbus A320-212
Service difficulty reports · 8,184
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13010653273Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152EF DAMAGED. NEW FLOOR PANEL FABRICATED IAW DWG 3D25-37705, SRM 53-02-00, FIG 209.SDR DALA13010643273Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151HF DAMAGED 7" X 5". NEW FLOOR PANEL FABRICATED IAW DWG 3D25-37705, SRM 53-02-00, FIG 209.SDR DALA13010633273Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151NF DAMAGED 5" X 5". NEW FLOOR PANEL FABRICATED IAW DWG 3D25-37705, SRM 53-02-00, FIG 209.SDR DALA13010623273Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131EF MISSING INSERT. NEW FLOOR PANEL FABRICATED IAW DWG 3D25-37705, SRM 53-02-00, FIG 209.SDR DALA13010613273Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 162BF DAMAGED 5" X 5". NEW FLOOR PANEL IAW DWG 3D25-37705, SRM 53-02-00, FIG 209.SDR DALA13010063273Web · corrodedDURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOOR SUPPORT UPPER SURFACE WEB HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. NO ALLOWABLE DAMAGE LIMITS IN SRM. R & R FLOOR SUPPORT WEB IAW SRM 51-42-11 & DWG D531143 32.SDR DALA13010053273Web · corrodedDURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOOR SUPPORT UPPER SURFACE WEB HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. NO ALLOWABLE DAMAGE LIMITS IN SRM. R & R FLOOR SUPPORT WEB IAW SRM 51-42-11 & DWG D531143.SDR DALA13010043273Floor Panel · delaminatedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261BG DELAMINATED. FABRICATED FLOOR PANEL IAW DWG 3D25-37498 AND SRM 53-02-00, FIG 209. AND INSTALLED.SDR DALA13010033273Floor Panel · damagedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261PF INSERTS RUSTY AND BOTTOM LT AFT CORNER DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37498, & SRM 53-02-00, FIG 209, INSTALLED FLOOR PANEL.SDR DALA13010023273Floor Support · corrodedDURING INSPECTION, FOUND FORWARD CABIN FLOOR SUPPORT BETWEEN FR12 TO FR20, Y1292 UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND OUT OF LIMITS IAW SRM 53-11-14, FIG 101. REPLACED FLOOR SUPPORT IAW 51-42-11, AIPC 53-11-01, FIG SDR DALA13010013273Fitting · corrodedDURING INSPECTION, FOUND FORWARD LT PASSENGER DOOR LWR ENTRANCE MID FWD UPPER SURFACE FITTING AROUND NUTPLATES HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, NO ESTABLISHED LIMITS ON SRM 53-11-14. REPLACED FITTING IAW SRM 51-42-11 & DWG D53112109.SDR DALA13009683273Web · corrodedDURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA LT SIDE INDB FR16 UPPER SURFACE WEB HAS CORROSION. BLENDED AREA IAW SRM 51-74-00 L=1.5" W=1.0" D-.006" NO ALLOWABLE LIMITS ESTABLISHED IN SRM. REPLACED FORWARD UTILITY AREA LT SIDE WEB BETWEEN FR12 TO FR1SDR DALA13010003273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 68 TO FR 69,Y1292 UPPER SURFACE FLANGES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT LIMITS IAW TRM 53-41-15. REPLACED FLOOR SUPPORT IAW SRM 51-42-11 & DWG D53472000.SDR DALA13009673273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BTW FR 66 TO FR 68 Y1292 UPPER SURFACE FLANGES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. CHECKED LIMITS L=1.0 W= 1.00"D=0.055" FOUND TO BE OUT LIMITS IAW TRM 53-41-15. REPLACED FLOOR SUPPORT ISDR DALA13009663273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 64 TO FR 66,Y1292 HARD POINT SURFACE HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. CHECKED LIMITS L=1.50"W=1.50"D=0.060" FOUND TO BE OUT LIMITS IAW TRM 53-41-15. REPLACED FLOOR SUPSDR DALA13009653273Floor Panel · delaminatedDURING INSPECTION, FOUND FWD UTILITY AREA FLOOR PANEL 222FF LOWER SURFACE DELAMINATED AND CORRODED. REPLACED FLOOR PANEL IAW SRM 51-72-00.SDR DALA13009643273Floor Panel · delaminatedDURING INSPECTION, FOUND FWD UTILITY AREA FLOOR PANEL 221FF LOWER SURFACE DELAMINATED AND CORRODED. REPLACED FLOOR PANEL IAW SRM 51-72-00.SDR DALA13009633273Sill · corrodedDURING INSPECTION, FOUND LT AFT PASSENGER/CREW DOOR SILL AT AFT FR66 AROUND ANCHOR NUT HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 L=1.0 W=.500 D=.053 OUT OF LIMITS IAW SRM 53-41-14 FIG 101. REPLACED DOOR SILL IAW DWG 53480020.SDR DALA13009623273Floor Support · corrodedDURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOOR SUPPORT RT SIDE STRG 23R FR20 UPPER SURFACE WEB HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. L=1.5 W=.200 D=.005 NO ESTABLISHED LIMITS IN SRM. REPLACED -Y1792 WEB FR16-FR20 IAW SRM 51-42-11 & DWSDR DALA13009523273Blanking Plate · corrodedDURING INSPECTION, FOUND L-1 DOOR FWD & AFT PLANKING PLATES HAVE CORROSION. REMOVED CORROSION IAW SRM 51-74-00, CHECKED DIMENSIONS AS FOLLOWS: AFT L=1.0", W=0.80", D=0.005"; FWD L=1.20", W=1.0", D=0.004", NO ALLOWABLE DAMAGE LIMITS IN SRM. REPLACED FWD & AFSDR DALA13009543273Floorbeam · corrodedDURING INSPECTION, FOUND AFT CABIN FLOOR SUPPORT RT SIDE BTW FR 65-66, Y-1732 UPPER SURFACE FLANGES & AROUND HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 L=1.0" W=1.0" D=.050" NO LIMITS IAW SRM 53-41-14, FIG 101. REPLACED FLOOR SUPPORT IAW SRM 51-SDR DALA13009533273Floor Support · corrodedDURING INSPECTION, FOUND AFT CABIN FLOOR SUPPORT LT SIDE BTW FR 65 TO FR 66, Y1732 UPPER SURFACE FLANGES & AROUND HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 L=1.73" W=1.20" D=.043NO ALLOWABLE LIMITS FOR THIS AREA. REPLACED FLOOR SUPPORT IAW SRMSDR DALA13009513273Floor Support · corrodedDURING INSPECTION, FOUND FORWARD CABIN FLOOR SUPPORT BETWEEN FR18-20 Y-254, UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. CHECKED LIMITS L=3.40" W=0.03" D=0.057 FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14 FIG 105. REPLACED FLOOR SUPPSDR DALA13009443274Skin · damagedDURING INSPECTION, FOUND LIGHTNING STRIKE ON EXTERNAL SKIN FR 21+5" AND 3" ABOVE STR 38R APROX, FWD FUSELAGE. PERFORMED PERMANENT REPAIR ON EXTERNAL SKIN FR 21+5" AND 3" ABOVE STR 38R APROX, FWD FUSELAGE IAW SRM A320 53-00-11, FIG 232.SDR DALA13009403263Connector · disconnectedDURING NON ROUTINE CHECK, FOUND SEAT 23C EMERGENCY PATH LIGHT INOPERATIVE. MX RECONNECTED PULLED OUT CONNECTOR TO LIGHT ASSY AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA13009393273Blanking Plate · corrodedDURING INSPECTION, FOUND R1 DOOR FWD AND AFT BLANKING PLATES CORRODED. REMOVED CORROSION IAW SRM 51-74-00, DIMENSIONS AS FOLLOWS: FWD L=1.5" W=1.0"D=.006", AFT L=1.0" W=1.0" D=.005" NO ALLOWABLE DANAGE LIMITATION IN SRM, REPLACED FWD & AFT BLANKING PLATESDR DALA13009383274Skin · damagedDURING INSPECTION, FOUND LIGHTNING STRIKE ON FASTENER LOC FR 27+19" AND STR 41R LOWER FUSELAGE. PERFORMED PERMANENT REPAIR LOC. FR 27+19" AND STR 41R LOWER FUSELAGE IAW SRM A320 53-21-11, PARA 5J FIG 2013 (SHEET 2) PAGES 327/328.SDR DALA13009463273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT RT SIDE BETWEEN FR 66-68, Y-1292 UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. AREA MEASURES L:2" W:1" D:.080" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REPLACED FSDR DALA13009453273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 64 TO FR 66 Y-1292 HARD POINT HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. AREA MEASURES L:1" W:1" D:.075" ORIG MAT. .100". FOUND OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R SDR DALA13009433273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 68-69 Y-1292 UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. AREA MEASURES L:4" W:3" D:.108" ORIG MAT. .155". FOUND OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REPLACSDR DALA13008943273Floorbeam · corrodedDURING INSPECTION, FOUND FORWARD CABIN FLOORBEAM BETWEEN FR16 TO FR23 Y254 UPPER SURFACE FLANGE HAS CORROSION. REPLACED FLOORBEAM Y254V FROM FR14-FR24 IAW SRM 51-42-11. REMOVED CORROSION IAW SRM 51-74-00. CHECKED LIMITS L=2.0" W=1.0" D=0.079". FOUND TO BE SDR DALA13008933273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOORBEAM BETWEEN FR64 TO FR66, Y765 UPPER SURFACE FLANGE & HARD PT. HOLES HAS CORROSION. REPLACED FLOORBEAM Y765 IAW SRM 51-42-11. BEAM WAS FOUND TO BE CORRODED OUT OF LIMITS IAW TRM 53-41-15. L=1.5" W=.5" D=.050".SDR DALA13008923273Floor Panel · damagedDURING INSPECTION, FOUND FWD CABIN FLOOR PANEL 231 QF DAMAGED 3.0"X 4.0". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13008913273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOORBEAM BETWEEN FR 65 TO FR 66 Y-465 UPPER FLANGE AND HARD PT HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, CHECKED LIMITS, L=2"W=1"D=.035", FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REPLACED SDR DALA13008883273Floorbeam · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOORBEAM AT FR 68 Y765 UPPER FLANGE HAS CORRODED. BLENDED CORROSION IAW SRM 51-74-00; FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15, L 2.0" W= 2.2 "D= 0.065"; REPLACED FLOORBEAM IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13008873274Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON LOWER SILL LT SIDE FR 68 AFT PAX CABIN. REPLACED LOWER SILL LOCATED LT SIDE BETWEEN FR 66 TO FR 68 AT LEVEL STR 23L AFT PAX CABIN IAW SRM 51-72-11 AND DWG 53480019.SDR DALA13008853274Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION, BEAM -Y1192 FR 67 AFT PAX CABIN SSI 534147 L=1.644" W=0.950" D=0.028". REPLACED BEAM -Y1192 FR 67 TO FR 68 AFT PAX CABIN IAW SRM A320 51-72-11 AND DWG D53472040.SDR DALA13008793274Structure · corrodedDURING INSPECTION, FOUND CORROSION ON FWD LOWER CORNER FR 66 AT LEVEL OF STR 23R AFT PAX CABIN. REPLACED IAW 51-72-11 AND DWG D53480505.SDR DALA13008903273Support · corrodedDURING INSPECTION, AFT CABIN RT SIDE BETWEEN FR 69 TO 70 FRAME SUPPORT OF SHEAR PLATE CORRODED ON UPPER & LOWER SURFACE. REMOVED CORROSION IAW SRM 51-74-00; CHECKED LIMITS DIMENSIONS L=1.0"W=0.900"D=0.017" FOUND TO BE OUT OF LIMITS IAW SRM 53-41-17; REPLACED SDR DALA13008893273Floorbeam · corrodedDURING INSPECTION, FOUND FORWARD CABIN FLOORBEAM BETWEEN FR 20-21 Y-189 UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW 53-11-14, FIG 105. REPLACED FLOORBEAM Y-189 IAW SRM 51-42-11.L=1.244"X W=1. 050"X D=SDR DALA13008863273Floor Support · corrodedDURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOORBEAM BETWEEN FR 12-16 Y503.2 UPPER SURFACE FLANGE HAS CORROSION. FLOORBEAM Y503.2 FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED FLOORBEAM IAW SRM 51-42-11. LOCATED AND DRILLED NEW BEAM IAW SRM 5SDR DALA13008843273Floorbeam · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOORBEAM LT SIDE AT FR68, Y465 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. CHECKED LIMITS L=1.6" W=W=1.0" D=.055" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R FLOORBEAM IAW SRM 51-42-11SDR DALA13008833273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 66 TO FR69 Y-765 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. BLENDED AREA MEASURES L=4.0" W=1.0" D=.025" FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15, ORIG MAT .157". R & R FLOSDR DALA13008823273Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR67 TO FR68 Y-254 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. CHECKED LIMITS L=1.0" W=1.5" D=0.050" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REPLACED FLOOR SUPPSDR DALA13008813274Hinge · wornDURING BEARING REMOVAL OF RUDDER HINGE NR 7 THE BORE FOUND WITH WEAR. THERE IS NO ALLOWABLE DAMAGE NOT REPAIR ON ANY MANUAL, HINGE NR 7 MUST BE REPLACED. REPLACED HINGE NR 7 AND FASTENERS IAW SRM 51-72-11.SDR DALA13008783273Floor Panel · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 262FF IS CORRODED ON UNDERSIDE. REMOVED CORROSION IAW SRM 51-74-00. CHECKED DIMENSIONS, NO ALLOWABLE DAMAGE IN SRM. REPLACED FLOOR PANEL.SDR DALA13008773274Floor Support · corrodedDURING INSPECTIO, FOUND CORROSION ON LOWER SILL RT SIDE FR 66 AFT PAX CABIN. REPLACED LOWER SILL AND LOCK FASTENERS. R2 FR 66 TO FR 68 AFT. PAX CABIN IAW SRM A320 51-72-11 AND DWG D53480019.SDR DALA13008763274Structure · corrodedDURING INSPECTION, FOUND CORROSION ON AFT LOWER CORNER FR 68 AT LEVEL OF STR 23R AFT PAX CABIN. REPLACED AFT LOWER CORNER LOC. ON FR 68 AT LEVEL OF STR 23R AFT PAX CABIN SRM A320 51-72-11 AND DWG 53480505.SDR DALA13008753274Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM FR 66 -Y464 AFT PAX CABIN. REPLACED FLOORBEAM IAW SRM 51-42-11 AND SRM 51-72-11, DWG D53472816.SDR DALA13008743274Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON BEAM -Y1292 FR 66 AFT PAX CABIN SSI 534147, L=0.438", W=0.118", D=0.028". REPLACED BEAM -Y1292, FR 64 TO FR 66 AFT PAX CABIN IAW SRM 51-72-11 AND DWG D53472000.
Back to Airbus A320-212