Airbus A320-214
Service difficulty reports · 10,616
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA050755Floor Support · corrodedPIT- CS1 - FLOOR SUPPORT, 1 INCH DIA X .050 INCH DEEP (6 SPOTS) CORROSION; NO LEVEL OR TASK, FLOOR SUPPORT AT Y765 AND FRAME 67. REPAIRED IAW EA 95741 FOR INTERM REPAIR, THEN FINAL RESTORATION TO REPLACE PART WAS ACCOMPLISHED. (K)SDR USAA050754Floorbeam · corrodedPIT - S2 - CABIN FLOORBEAM, 2 INCH X 2 INCH AREA, CORROSION; LEVEL 2; TASK JA-220-53500 CABIN FLOORBEAM AT FR 21-23 AT +Y254. REPLACED FLOORBEAM IAW SRM. (K)SDR USAA050763Floorbeam · corrodedPIT - S2 - FLOORBEAM .5 INCH AREA; CORROSION; LEVEL 2; TASK JA-260-53500, FRAME 16, Y-50. INSTALLED DOUBLED ANGLE AND FILLER IAW SRM.SDR SA05072Strap · misroutedPIT - THE AFT RIGHT SLIDE YELLOW RELEASE STRAP WAS FOUND NOT ROUTED THROUGH THE RELEASE TRIGGER OF THE GIRT BAR. MAINTENANCE CORRECTLY ROUTED THE RELEASE STRAP. OK FOR SERVICE.SDR SA05071Wire Harness · misroutedPHL - THE AFT, LEFT HAND SLIDE HAD A LIGHT HARNESS ROUTED INCORRECTLY AND A COVER RELEASE CABLE DISCONNECTED. MAINTENANCE CORRECTLY ROUTED THE LIGHT HARNESS ASSEMBLY AND CONNECTED THE COVER RELEASE CABLE.SDR SA05070Fuel Control · failedEN ROUTE, PHL TO SFO - DURING FLIGHT, THE APU AUTO-SHUTDOWN WITH THE NR 1 ENGINE IDG ON MEL. FLIGHT CONTINUED TO DESTINATION AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE SERVICED THE APU WITH 2.5 QUARTS OF OIL AND TIGHTENED A LINE TO THE APU FUEL CONTROLSDR SA05068Epsu · faultyPIT - THE EMERGENCY LIGHTS SYSTEM TESTED INOPERATIVE. MAINTENANCE REPLACED THE AFT EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK.SDR SA05067Epsu · faultyPIT - THE EMERGENCY LIGHTS SYSTEM TESTED INOPERATIVE. MAINTENANCE REPLACED THE FORWARD EMERGENCY POWER SUPPLY UNIT AND BATTERIES. OPERATIONALLY CHECKS OK.SDR USAA050764Floorbeam · corrodedPIT - S2 - FLOOR SUPPORT ANGLE, 1 INCH X 1 INCH X .040 INCH DEEP, CORROSION; LEVEL 1; TASK JA-220-53500-004, FRAME 16, +Y65. DEFECTIVE PART REPLACED WITH IDENTICAL. (K)SDR U30A200500004Oven · unknownDURING CRUISE, AFT F/A SMELLED SMOKE IN AFT GALLEY (G5). OPENED NR 1 OVEN, FOUND MEALS CONTAINED IN BOXES BURNED ON END. SMALL FIRE EXISTED & EXTINGUISHED. POWER REMOVED FROM OVEN, PULLED C/B. NR 1 OVEN INSERT (CARRIER FOR MEALS) DID NOT HAVE A METAL BACK SDR SA05061Cable · damagedPHL - DURING INSP FOUND FORWARD RIGHT SIDE DOOR SLIDE RELEASE COVER CABLE CONNECTION BAD. REPLACED FORWARD RIGHT SIDE DOOR SLIDE/RAFT ASSEMBLY.SDR SA05059Lanyard · missingDCA - AFT RIGHT DOOR SLIDE/RAFT ASSEMBLY SURVIVAL LANYARD AND RELEASE SNAP FOUND MISSING. REPLACED AFT RIGHT DOOR SLIDE/RAFT ASSEMBLY. OK FOR SERVICE.SDR SA05054Servo Valve · failedDURING TAKE-OFF ROLL, THE BRAKES BEGAN TO SURGE, CAUSING THE AIRCRAFT TO VEER ON THE RUNWAY. AT THE SAME TIME, A BRAKE SYSTEM 1 FAULT ECAM MESSAGE GENERATED. THE TAKE-OFF WAS REJECTED AT 40 KNOTS. THE FLIGHT RETURNED TO THE GATE WITHOUT FURTHER INCIDENT. MSDR SA05053Line · misroutedPIT - MAINTENANCE FOUND THE FORWARD, RIGHT SIDE, DOOR EMERGENCY ESCAPE SLIDE ASSEMBLY MOORING LINE INCORRECTLY ROUTED. MAINTENANCE CORRECTLY ROUTED THE MOORING LINE. OK FOR SERVICE.SDR SA05051Light · faultyCLT - FLOOR LEVEL EMERGENCY EXIT IDENTIFIER WAS FOUND INOPERATIVE AT THE L-1 DOOR. MAINTENANCE REPLACED THE EXIT IDENTIFIER LIGHT ASSEMBLY, FIN 90WL1. OPERATIONALLY CHECKS OK.SDR U30A200500003Structure · damagedDURING POST FLIGHT, DAILY INSPECTION, GROUND EQUIPMENT INDUCED DAMAGE WAS FOUND TO LOWER AFT CORNER OF L2 (LT AFT PAX/CREW ) DOOR. MAINTENANCE INSPECTED THE DOOR IAW SRM. MAINTENANCE ALSO PERFORMED A HFEC (HIGH FREQUENCY EDDY CURRENT) INSPECTION IN COMPLIANCESDR USAA050656Seat Track · corrodedPIT - FOUND OUTBOARD SEAT TRACK FLOORBEAM CORRODED 1 INCH DIAMETER IN 5 AREAS, OUTBOARD SEAT TRACK, FLOORBEAM AT Y1292L. CORROSION LEVEL 2; TASK JA-220-53500. FOUR AREAS BLENDED, 1 AREA HAD CORROSION CUT OUT AND REPAIR INSTALLED PER SRM 53-11-15. (M)SDR USAA050658Track · corrodedPIT - FOUND TRACK CORRODED .5 INCH AREA, AT FRAME 16 Y503. REPLACED WITH IDENT PART. (M)SDR USAA050659Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED TWO .5 INCH AREAS, AROUND SCREW HOLES, FLOORBEAM Y1292 RT AT C68. CORROSION LEVEL 2, TASK JA-260-53500. DEFECTIVE PART REPLACED WITH IDENT PART PR D5347218920400. (M)SDR USAA050557Seat Track · corrodedPIT - FOUND SEAT RAIL CORRODED 2 INCHES BY 2 INCHES, Y765 LET FLOORBEAM, TOP SURFACE AT BARREL NUT HOLE AT FRAME 66. REMOVED AND REPLACED ORIGINAL PART PER AIRBUS DWG D53472780 AND SRM 53-31-15. (M)SDR USAA050556Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED 4 INCHES BY 5 INCHES, Y1292 LT FLOORBEAM ON TOP SURFACE AT SEVERAL LOCATIONS FORWARD OF FRAME 66-68. CORROSION LEVEL 1, TASK JA-360-53500. REMOVED AND REPLACED ORIGINAL PART PER AIRBUS DWG D53472815. (M)SDR USAA050558Floorbeam · corrodedPIT - FOUND BEAM CORRODED .125 INCH TO .25 INCH, AROUND NUTPLATE HOLES ON FLOORBEAM Y425L FROM C21-C23. REPLACED BEAM PER DWG 53110900. (M)SDR USAA050555Floorbeam · corrodedPIT - FOUND BEAM CORRODED 1 INCH DIAMETER, FLOORBEAM AT Y525L AFT HOLE ABOVE CROSSBEAM C-16. REPLACED BEAM PER DWG 53110900. CORROSION LEVEL 2, TASK JA-220-53500. (M)SDR SA05045Odor · detectedDURING FLIGHT, PASSENGERS AND CABIN CREW NOTICED A BURNING ODOR NEAR SEAT ROW 11. CREW ELECTED TO DIVERT TO FLL FOR MAINTENANCE ACTION. MAINTENANCE OPERATIONALLY CHECKED THE AIRCONDITIONING SYSTEM. OPERATIONALLY CHECKED OK.SDR USAA050477Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED 2.5 INCHES DIAMETER AREAS, FLOORBEAM GALLEY MOUNTING HOLES OUTBOARD FLOORBEAM, BETWEEN RT SIDE C68-69. DEFECTIVE PART REPLACED WITH IDENT PART NR. (M)SDR USAA050496Floorbeam · corrodedFOUND FLOORBEAM CORRODED 1 SQUARE INCH, AROUND NUT PLATE HOLES, FLOORBEAM C66-C69 LEFT OUTBOARD. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 51-72-11. CORROSION LEVEL 1, TASK JA 260-53500. (M)SDR USAA050479Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED 2 INCHES BY 2 INCHES BY .060 INCH DEEP AREA, FLOOR SUPPORT AT Y750 ABOVE C68. CORROSION LEVEL 1, TASK JA-260-53500. DEFECTIVE PART REPLACED WITH IDENT PART NR PER SRM 51-72-11. (M)SDR USAA050478Floorbeam · corrodedFLOORBEAM CORRODED .5 INCH DIAMETER AREA, FLOORBEAM AT FRAME 20, 9 INCH RIGHT OF CENTER. REMOVED CORROSION, INSTALLED DOUBLER PER SRM 53-11-14. CORROSION LEVEL 1, TASK JA-220-53300. REMOVED CORROSION, INSTALLED DOUBLER PER SRM 53-11-14. (M)SDR USAA050522Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED 2 INCH BY 2 INCH AREA, LEFT INBOARD AFT FLOORBEAM Y765 FRAME C64-C70. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 53-41-14. CORROSION LEVEL 1, TASK JA-260-53500. (M)SDR USAA050465Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED 1 BY .5 BY .030 INCH, .75 INCH BY .5 INCH BY .030 INCH, .75 BY .3750 BY .05, FLOOR BEAM 10 INCHES LEFT OF CENTER LINE BETWEEN C16 AND C22. DEFECTIVE PART REPLACED WITH IDENT PART. (M)SDR USAA050393Skin · crackedPIT - RON - AFT CARGO DOOR INNER, .7500 INCH CRACK, INNER SKIN LOWER FWD CORNER. CUT OUT DAMAGE, INSTALLED DOUBLER EA. (K)SDR U30A200500002Pipe · leakingCREW RECEIVED AN ECAM MESSAGE, GREEN HYD LOW PRESS. TURNED OFF PUMP & PTU. STATUS PG INDICATED LOW PRESS & NIL QTY. DIVERTED, DECLARED AN EMERGENCY. ECAM GENERATED APPROACH LIST INSTRUCTS TO TURN PTU BACK ON TO TRY TO RESTORE PRESSURE, PRESSURE RESTORED. SDR SA05019Power Supply · inoperativeFOUND FAULT ON LEFT AFT EMERGENCY EXIT LIGHT. MAINTENANCE REPLACED THE EPSU.SDR SA05016Proximity Sensor · faultyEN ROUTE MSY TO CLT - AFTER TAKEOFF, THE LANDING GEAR INDICATES DOWN AFTER THE LANDING GEAR LEVER WAS MOVED UP. UPON ARRIVAL, THE LANDING GEAR HAD AMBER -X- INDICATIONS ON THE WHEEL PAGE. MAINTENANCE REPLACED THE LEFT MAIN LANDING GEAR EXTENSION PROX SENSOR,SDR SA05015Lanyard · looseCLT - PRIOR TO DEPARTURE, THE CABIN CREW COULD NOT GET ESCAPE SLIDE TO ARM AT DOOR 2R. MAINTENANCE SECURED A LOOSE LANYARD ON SLIDE AT 2R DOOR. SLIDE ARMING OPERATIONALLY CHECKS OK.SDR USAA050153Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH, FR 66 (Y765). INSTALLED REPAIR ANGLES IAW EA 96224. (M)SDR SA05009Controller · failedPHX - FLT 1011 EN-ROUTE, PHL - PHX, DURING FLIGHT, THE FIRST OFFICER'S WINDSCREEN STARTED TO ARC AND DELAMINATE. THE CREW PULLED THE WINDSHIELD HEAT CIRCUIT BREAKER. THE FLIGHT CONTINUED TO PHX AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE F/SDR U30A200500001Bleed Valve · crackedNR 2 ENG BEGAN COMPRESSOR STALLING. FLT CREW NOTICED THAT N1 WENT TO 43 PERCENT & FLUCTUATED BETWEEN 43 & 45 PERCENT. DECLARED AN EMERGENCY. AT ABOUT 10,000 FT, NR 2 ENGINE STABILIZED & APPEARED TO OPERATE NORMALLY. A VISUAL APPROACH TO A LANDING ON RUNWAY 6 ASDR USAA041095Floorbeam · corrodedBFM - S1-CHECK - SUPPORT BEAM - 1.5 X 1.2 X 0.035 INCH AND 1.5 X 1.5 X 0.040 INCH, CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN Y1292, FR 66. REMOVED AND REPLACED WITH NEW PART IAW SRM. (K)SDR USAA041085Floorbeam · corrodedBFM - S1 CHECK- BEAM, 3.1 INCH X 1.5 INCH X 0.043 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500-005, FLOOR SUPPORT BEAM AT Y765, FR 66. REMOVED AND REPLACED BEAM ASSY IAW SRM. (K)SDR USAA041084Floor Support · corrodedBFM - S1-CHECK - SUPPORT BEAM, 40 INCHES X 2 INCHES X .045 INCH AREA. CORROSION; LEVEL 2; TASK NR JA-220-53500-003, FLOOR SUPPORT BEAM FR16 - FR21, Y254. FAB PARTS IAW SRM. (K)SDR USAA041097Floorbeam · corrodedBFM - S1-CHECK - FLOOR BEAM, 16 INCHES L X 2 INCHES X .027 INCH D, CORROSION; LEVEL 2; TASK JA-220-53500-001, BEAM Y1292, FR 16-20. REMOVED AND REPLACED WITH NEW BEAM IAW SRM. (K)SDR USAA041096Support Beam · corrodedBFM - S1-CHECK - SUPPORT BEAM - SEAT TRACK; 1 INCH X 2 INCH X 0.060 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-220-53500, MAIN CABIN Y765, FR 16. REMOVED AND REPLACED WITH NEW PART IAW SRM. (K)SDR USAA041094Support Beam · corrodedBFM - S1 CHECK - SUPPORT BEAM, 3.33 INCHES X 1.25 INCH X 0.060 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN Y1292, FR 68. REMOVED AND REPLACED WITH NEW PART IAW SRM. (K)SDR USAA041093Support Beam · corrodedBFM - S1-CHECK - SUPPORT BEAM, 2.15 X 1.0 X .036 INCH AND 1.73 X 1.70 X .052 INCH. CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN Y1292, FR 66-68. (K)SDR USAA041092Floor Panel · corrodedBFM - S1-CHECK - FLOOR PANEL, .300 INCH X .200 INCH X 0.032 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-260-53100, FLOOR PANEL NR 261 FF, Y1292, FR 66-68. REMOVED AND REPLACED WITH NEW PART IAW SRM. (K)SDR USAA041091Floor Panel · corrodedBFM - S1 CHECK - FLOOR PANEL, .500 INCH X .300 INCH X 0.032 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-250-53100-002. FLOOR PANEL NR 262FF, Y1292, FR 66-68. REMOVED AND REPLACED WITH NEW PART IAW SRM. (K)SDR USAA041082Floor Panel · corrodedBFM - S1 - PANEL, 4 INCHES X 1 INCH X 0.060 INCH AREA, CORROSION; NO LEVEL OR TASK, MAIN CABIN FLOOR PANEL, 221FF. REMOVED AND REPLACED PANEL IAW SRM. (K)SDR USAA041081Floor Panel · corrodedBFM - Q1 - PANEL, 0.500 INCH X 2.0 INCH X 0.060 INCH AREA, CORROSION; NO LEVEL OR TASK; MAIN CABIN FLOOR PANEL 222FF. REMOVED AND REPLACED PANEL IAW SRM. (K)SDR USAA041088Floorbeam · corrodedBFM - S1-CHECK - BEAM, 2.0 INCH X .75 INCH X 0.052 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN FLOOR BETWEEN FR 68-69, BL Y1292. REMOVED AND REPLACED BEAM ASSY IAW SRM. (K)
Back to Airbus A320-214