Airbus A320-214
Service difficulty reports · 10,616
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA041087Beam · corrodedBFM - S1 CHECK- BEAM, 2.1 INCH X 1.0 INCH X .0200 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500-006, MAIN CABIN FLOOR AT FR 68, BL-Y254. REMOVED AND REPLACED BEAM ASSY IAW SRM. (K)SDR USAA041086Beam · corrodedBFM - S1 CHECK - BEAM, 2.0 INCH X 1.2 INCH X 0.049 INCH AREA, CORROSION; LEVEL 2; TASK NR JA 260-53500, MAIN CABIN FLOOR BTW FR 66-68, BI - Y1292. REMOVED AND REPLACED BEAM ASSY IAW SRM. (K)SDR USAA041090Seat Track · corrodedBFM - S1 CHECK - SEAT TRACK, 5.3 INCH X 1.0 X 0.030 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-220-53500-007, SEAT TRACK AT Y1292, APPROX FR 21. INSTALLED NEW SEAT TRACK SEGMENT AND REPAIR ANGLES IAW SRM. (K)SDR USAA041083Floorbeam · corrodedBFM - S1 CHECK, FLOORBEAM, 2.4 INCH L X 1.81 INCH X .066 INCH D, CORROSION; LEVEL 2; TASK NR JA260-53500-007, FR 66,Y765, Z240. REMOVED AND REPLACED WITH NEW FLOORBEAM IAW SRM. (K)SDR USAA041089Dummy Rail · corrodedBFM - S1 - DUMMY RAIL, 18 INCHES X 2.5 INCHES X 0.070 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-220-53500, DUMMY RAIL AT Y503.2 BTW FR 12-16. REPLACED DUMMY RAIL IAW SRM. (K)SDR SA04110Epsu · faultyTHE RIGHT SIDE MID-CABIN EMERGENCY POWER SUPPLY UNIT INDICATED INOP WHEN IT FAILED THE EMERGENCY LIGHTS TEST. MAINTENANCE REPLACED THE MID-CABIN, RIGHT SIDE, EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK.SDR SA04103Slide · wornDURING TROUBLESHOOTING, MAINTENANCE FOUND THE AFT LEFT PASSENGER DOOR SLIDE LACING WORN ALMOST ALL THE WAY THROUGH. MAINTENANCE REPLACED THE AFT LEFT DOOR SLIDE. OK FOR SERVICE.SDR SA04102Diaphragm · crackedTHE AFT LEFT PASSENGER DOOR WILL NOT OPEN FROM INSIDE OR OUTSIDE. MAINTENANCE FOUND THE DOOR ASSIST DAMPER PRESSURIZED BY A CRACKED SEAL. MAINTENANCE REPLACED THE CRACKED SEAL. OPERATIONALLY CHECKS OK.SDR USAA040969Sill · corrodedPIT - S1 - SILL, 1 INCH X 1 INCH X .07 INCH DEEP; CORROSION; LEVEL 2; TASK NR JA-260-53500-006; CABIN FLOOR, R-2 DOOR SEAL ASSY ON CROSSBEAM C66 AND AFT ENDI OF FRAME - Y1732. REPLACED DOOR SEAL IAW SRM 51-74-00, 53-41-14, 51-42-11.SDR USAA040955Floor Support · corrodedBFM - S1 - FLOOR SUPPORT, 2 INCH X 3 INCH X 0.075 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-220-53500; MAIN CABIN FLOOR - Y254 BET FR 16 AND 20. FABRICATED PARTS IAW SRM 53-00-14 FIG 206 PR SRM 53-11-14, 51-74-00, 53-14-00, 51-42-11.SDR USAA040958Track · corrodedBFM - S1 - TRACK ASSEMBLY, 2 INCH X 2 INCH X 0.50 INCH AREA, CORROSION LEVEL 2; TASK NR JA-220-53500, MAIN CABIN FLOOR- Y254 BET FR16 AND 23. REMOVED AND REPLACED IAW SRM.SDR USAA040957Web · corrodedBFM - S1 - FLOOR WEB, 1.5 INCH X 2 INCHES X 0.50 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-220-53500, MAIN CABIN FLOOR; Y1584, BET FR14 AND 16. REMOVED AND REPLACED IAW SRM.SDR U30A200400012Windscreen · crackedDURING DESCENT TO 370, CAPT NOTICED SMALL CRACK ON CAPT'S FRONT WINDSCREEN. FLT CREW REQUESTED LOWER ALTITUDE & ATC COULD NOT COMPLY & TOLD FLT TO MAINTAIN 370. CRACK STARTED TO WIDEN & SPREAD RAPIDLY, FLT CREW REQUESTED AN EMERGENCY DESCENT. FLT CREW SEAT SDR USAA040959Support · corrodedBFM - S1 - SUPPORT, 2 INCH X 5 INCHES X .025 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-220-53500, MAIN CABIN FL -Y189, FR 20. REMOVED AND REPLACED IAW SRM.SDR USAA040966Dummy Rail · corrodedBFM - S1 - DUMMY RAIL, 2 INCHES X 1 INCH X .050 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-220-53500. MAIN CABIN FLOOR @ FR 16, LB -Y81. REPLACED DUMMY RAIL IAW SRM.SDR USAA040962Floor Support · corrodedBFM - S1 - FLOOR SUPPORT, 1.5 INCH X 2 INCHES X .040 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-200-53500, BTW FR 16 AND 20, Y1292, FLOOR SUPPORT. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-11-14, 51-42-11.SDR USAA040956Floor Support · corrodedBFM - S1 - FLOOR SUPPORT, 2 INCHES X 12 INCHES X 0.020 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-220-53500, MAIN CABIN FLOOR BET FR 16, 20, BL-Y1292. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-11-14, 51-42-11.SDR USAA040954Support · corrodedBFM - S1- SEAL SUPPORT, .5 INCH X .5 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-220-53500-015, MAIN CABIN FLOORBOARD SEAL SUPPORT AT Y1584 BETWEEN 14 AND 16. REMOVED AND REPLACED FLOORBOARD SEAL SUPPORT IAW SRM 51-74-00, SRM 53-11-14, SRM 51-42-11.SDR USAA040965Floorbeam · corrodedBFM - S1 - FLOORBEAM- 2 INCHES X 1.5 INCHES X .04 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-260-53500-012, Y1292, BTW C68 AND C69 MAIN CABIN FLOOR. REMOVED AND REPLACED FLOOR BEAM IAW SRM 53-00-14, SRM 51-42-11.SDR USAA040963Dummy Rail · corrodedPIT - S1 - DUMMY RAIL, 2.5 INCHES X 2 INCHES X .075 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-220-53500; MAIN CABIN FLOOR FR 16, Y503.2. REPLACED DUMMY RAIL (BEAM) ALT PN INSTALLED IAW SRM 51-74-00, 53-11-14, 51-42-11.SDR USAA040960Floorbeam · corrodedBFM - S1 - BEAM, 18 INCHES X 2 INCHES X .03 INCH AREA, CORROSION; LEVEL 2; TSK NR JA 260-53500-004, MAINT CABIN FLOOR Y1292 BET C66 AND C68. REMOVED AND REPLACED FLOORBEAM IAW SRM.SDR USAA040964Shear Plate · corrodedBFM - S2 - SHEAR PLATE, 1 INCH X 1 INCH X .030 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN FLOOR BTW 69 AND 70, BL - Y1292. REMOVED AND REPLACED SHEAR PLATE (WEB) IAW SRM.SDR USAA040961Floorbeam · corrodedBFM - S1 - BEAM, 3 INCHES X 2 INCHES X .030 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500; MAIN DECK FLOOR RAIL, FRAME 68, -Y765. REMOVED AND REPLACED FLOORBEAM IAW SRM 53-00-14, 51-42-11.SDR SA04097Slide · unserviceableLAX - THE SLIDE INTENDED TO REPLACE THE SLIDE IN THE FORWARD LEFT POSITION CAME APART PRIOR TO BEING INSTALLED. MAINTENANCE INSTALLED PREVIOUS SLIDE.SDR SA04092Slide · separatedTHE SLIDE SHOP FOUND THAT THE BRIDGING ON UPPER TUBE AT RUNWAY END HAD A SEAM SEPARATION. THE REPAIR SHOP SENT THE SLIDE BACK TO THE VENDOR FOR REPAIR.SDR SA04087Bulb · burned outPIT - AIRCRAFT FAILED THE EMERGENCY LIGHTS TEST. THE AFT EMERGENCY POWER SUPPLY UNIT SHOWS INT AND EXT FLASHING RED LED'S. THE EMERGENCY POWER SUPPLY UNIT AT THE LEFT, MID-CABIN INDICATES A CONTINUOUS RED LED. MAINTENANCE PLACED SYSTEM ON MEL. RELAMPED EMERSDR USAASA04084Psu · failedPHL - THE EMERGENCY POWER SUPPLY UNIT IN THE AFT LEFT POSITION FAILED THE TEST. MAINTENANCE REMOVED AND REPLACED THE AFT LEFT EMERGENCY POWER SUPPLY UNIT. OPS CHECK NORMAL. (M)SDR USAASA04081Epsu · inoperativeCLT - EMERGENCY LIGHT TEST FAILED. MAINTENANCE REPLACED THE MID RIGHT EPSU. (M)SDR U30A200400011Detector · intermittentPRIOR TO FLT 105 PHL-FLL, THE 2L PAX/CREW DOOR "ARMED" INDICATION WAS INTERMITTENT. MAINTENANCE INSPECTED AND CONFIRMED INTERMITTENT CONDITION. MAINTENANCE DEFERRED PER MEL 25-60-04-1 AND RETURNED THE AIRCRAFT TO SERVICE. ON 8/21/04, MAINTENANCE REPLACED THSDR U30A200400010Odor · detectedON INITIAL DESCENT, THE LEAD FLIGHT ATTENDANT ADVISED THE CAPTAIN OF A STRONG SMELL OF BURNING RUBBER AROUND ROW 7. THE FO WENT TO THE CABIN AND CONFIRMED THE SMELL. THERE WAS NO SMOKE AND NO HEAT RADIATING FROM THE FLOOR OR OVERHEAD BINS. THE LEAD FA WAS ISDR USAASA04079Panel · missingDURING PREFLIGHT OF THE EXTERIOR, PANEL 192DT WAS FOUND MISSING. MAINTENANCE REPLACED THE RIGHT SIDE, WING TO BODY PANEL 192DT. (M)SDR USAA040428Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 3 SQUARE INCHES BY .039 INCH, FRAME 66 AT Y254. INSTALLED DOUBLER PER EA 95752. (M)SDR USAA040427Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 5 SQUARE INCHES BY .030 INCH, FRAME 65-66 Y 765. INSTALLED DOUBLER PER EA 95741. (M)SDR USAA040431Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 2 SQUARE INCHES BY .035 INCH AREA, FRAME 66-68 Y1292. REMOVED CORROSION PER SRM 51-74-00. (M)SDR USAA040430Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 2 SQUARE INCHES BY .043 INCH AREA, FRAME 66Y 1292. INSTALLED DOUBLER PER EA 95743. (M)SDR USAA040429Floorbeam · corrodedCLT - FOUND FLOORBEAM WITH CORROSION 5 SQUARE INCHES BY .35 INCH AREA, FRAME 66-68. INSTALLED DOUBLER PER EA 95742. (M)SDR USAA040426Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 8 SQUARE INCHES BY .040 INCH, FRAME 66-68 Y1292. INSTALLED DOUBLER PER EA 95738. (M)SDR U30A200400009Glowstrip · crackedAFTER FLT 609, RSW-ORD, DURING MAINTENANCE, THE EMERGENCY FLOOR PATHWAY LIGHTING PHOTO LUMINESCENT STRIP BETWEEN SEAT ROWS 2 DEF AND 5 DEF WAS IDENTIFIED AS DAMAGED. MAINTENANCE REPLACED THE PHOTO LUMINESCENT STRIP BETWEEN ROWS 2 DEF AND 5 DEF IAW AMM 33-51-21SDR USAASA04073Psu · inoperativeDCA - THE EMERGENCY LIGHTS FAILED THE OPS TEST. MAINTENANCE REPLACED THE LEFT OVERWING EMERGENCY EXIT EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK. (M)SDR U30A200400008Odor · detectedAFTER PUSH BACK, THE AFT F/A'S REPORTED AN (ELECTRICAL) BURNING ODOR. THE FLIGHT CREW WAS NOTIFIED AND THE AIRCRAFT RETURNED TO THE GATE. MAINTENANCE INSPECTED THE AIRCRAFT IAW TSM 24-00-00-810-823 WITH NO DEFECTS NOTED. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR USAASA04069Flow Valve · failedGJT - FLT 82 - EN ROUTE SFO-PHL, WITH THE NR 2 PACK ON MEL, A NR 1 PACK FAULT OCCURRED. PRESSURIZATION WAS LOST AS A RESULT. FLIGHT MADE A RAPID DESCENT TO 10,000 FEET THE DIVERTED TO GJT DUE TO TERRAIN CONTRAINTS. AIRCRAFT LANDED WITHOUT FURTHER INCIDENT. SDR USAASA04068Wire · brokenPHL - DURING THE WEEKLY CHECK, FOUND THE EMERGENCY LIGHT AT ROW 19ABC INOPERATIVE. MAINTENANCE REPAIRED THE BROKEN PIN/WIRE UNDER THE SEAT. OPS CHECKS GOOD. (M)SDR USAASA04067Light · inoperativePHL - DURING WEEKLY CHECK, FOUND THE EMERGENCY LIGHT AT ROW 8ABC INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. OPS CHECKS OK. (M)SDR CA040812004Bolt · broken(CAN) ON WALK AROUND PILOT FOUND 2 TIE BOLTS (P/N 43-1304) BROKEN ON THE NR 1 MAINWHEEL ASSY, TOTAL CYCLES ON MAIN WHEEL ASSY SINCE LAST RE-FURB 427, TOTAL TIME ON TIE BOLTS UNKN.SDR USA2004F00085Slide · unserviceableTHE RT SIDE REAR SERVICE DOOR HAS A SLIDE PACK STRAP EXTENDING OUT OF THE DOOR. MAINTENANCE REPLACED THE RT SIDE REAR SERVICE DOOR SLIDE ASSY. OK FOR SERVICE.SDR U30A200400007Odor · detectedAFTER T/O, F/A NOTICED ODOR & HAZE VIEWED FROM FWD CREW SEATS IN AFT PORTION OF A/C. VERIFIED SAME CONDITIONS AFT. ADJUSTED AIR CONDITIONING SYS TO INCREASE AIRFLOW AND ELIMINATE ODOR & HAZE. HAZE & ODOR BEGAN TO CLEAR, TEN MINS LATER HAZE & ODORS RETURNED.SDR USAASA04065Lanyard · misroutedDURING AN INSPECTION OF THE GIRT BAR ROUTING, THE FORWARD LT AND RT, AND THE REAR RIGHT, ESCAPE SLIDE SURVIVAL KIT LANYARDS WERE FOUND ROUTED INCORRECTLY. MAINTENANCE CORRECTLY ROUTED THE SURVIVAL KIT LANYARDS. OK FOR SERVICE. (M)SDR USA2004F00065Strap · misroutedTHE EMERGENCY ESCAPE SLIDE/RAFT GIRT BAR RELEASE STRAP ON THE LT REAR ENTRANCE DOOR WAS FOUND ROUTED INCORRECTLY DURING INSPECTION. MAINTENANCE CORRECTLY ROUTED THE STRAP.SDR USAA040251Sill · corrodedSILL, 2.0 INCH X 1.0 INCH X 0.06 INCH AREA, CORRODED. BETWEEN FR 66 & 68, BL Y11371, WL Z240. INSTALLED NEW SILL IAW SRM.SDR USAASA04063Lanyard · misroutedPHL - FOUND DURING AN INSPECTION OF THE GIRT BAR LANYARD ROUTING, THE FORWARD LEFT ESCAPE SLIDE ELECTRICAL HARNESS, AND THE REAR RIGHT, ESCAPE LSIDE SURVIVAL KIT LANYARD WERE FOUND ROUTED INCORRECTLY. MAINTENANCE CORRECTLY ROUTED THE SURVIVAL KIT LANYARD AND
Back to Airbus A320-214