Boeing 727-223
Service difficulty reports · 5,313
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA990322Skin · corrodedTUL - SKIN CORROSION, STR 276 TO STR 286, STA 490 TO STA 500. INSTALLED REPAIR DOUBLER AND TRIPLER IAW ESO 11697. TST: 61,081.50 HOURS. CYCLES: 38,758. (X)SDR GAIA99037Bypass Light · illuminatedATL/JFK - DURING INITIAL DESCENT, OIL FILTER BYPASS LIGHT ILLUMINATED ON NR 2 ENGINE. PRIOR TO SHUT DOWN, OIL PRESSURE 45 PSI, OIL TEMP 102 DEGREES CELSIUS. FUEL HEAT HAD BEEN APPLIED FOR 1 MINUTE. CREW FOLLOWED OIL BYPASS LIGHT ILLUMINATION PROCEDURES. LISDR AALA990379Frame · buckledTUL - BELL FRAME STATION 1110 BENT, WEB AREA BUCKLED ABOVE STRINGER 26L ITEM 2 TOP OF BELL FRAME STATION 1110 GOUGED FROM TOO LONG FAST. CUT OUT DAMAGE, REPAIRED BELL FRAME PER SRM 51-40-3 DOUBLER 7075-T6 .063 BY 20 INCH LONG 2 ROWS 43 BACB30FP8 HI-LOCKS AND SDR AALA990368Frame · gougedTUL - TOP OF BELL FRAME GOUGED (FROM TOO LONG OF FAST), BELL FRAME STATION 1130 BELOW RT TIEDOWN FIITTING. CUT OUT DAMAGED AREA, INSTALLED DOUBLER PER AARD 3-10-07-3 DOUBLER 7075-T6 .063 THICK BY 9.5 INCH LONG, 16 BACB30FP8 AND 17 BACB30FPL HI-LOCKS, 2 ROWS ISDR AALA990332Skin · corrodedFUSELAGE SKIN CORRODED OUTBOARD SIDE OF STR 28R, STA 684. CUT OUT CORRODED SKIN, INSTALLED REPAIR IAW SRM 53-30-3, FIG 1. TST: 61,081.50 HOURS. CYCLES: 38,758. (X)SDR AALA990331Stringer · corrodedTUL - CORROSION INSIDE STRINGER 28R, STA 689. INSTALLED STRINGER REPAIR IAW SRM 53-10-3 FIGURE 1. TST: 61,081.50 HOURS. CYCLES: 38,758. (X)SDR AALA990347Stringer · corrodedTUL - CORROSION ON STR 28L AT STA 484 AND STA 496. REMOVED DAMAGED AREA AND INSTALLED NEW STRINGER SECTION AND REPAIR SPLICE PER 53-10-3 USING NEW STRINGER MATERIAL AND SPLICE MATERIAL BAC 1498-132 WITH 4 EACH .1875 INCH RIVETS EACH SIDE IN HAT CHANNEL AND 6 SDR GAIA9931Bulb · failedEN ROUTE FROM YIP TO HUF, THE CARGO SMOKE LIGHT ILLUMINATED. THE FLIGHT CREW FOLLOWED EMERGENCY CHECKLIST PROCEDURES. THERE WAS NO SMOKE OR SMELL INTHE COCKPIT OR THE CARGO COMPARTMENT. LIGHT EXTINGUISHED 15 MINUTES LATER. ALL TEST WERE GOOD. THE AIRCRAFT SDR AALA990395Fitting · misdrilledTUL - RIGHT CREASE BEAM 1183 END FITTING MIS-DRILLED ZERO EDGE DISTANCE ON FORWARD FASTENER, STATION 1176 STRINGER 17R. REMOVED 7 FASTENERS AND INSTALLED DOUBLER AND FILLERS PER ESO 11697 DATED 2-26-99. (M)SDR AALA990371Frame · corrodedTUL - FOUND CORROSION ON 720E FRAME, FORWARD SIDE, FROM STRINGER 7L TO STRINGER 4L, 7 SPOTS (MARKED). REMOVED CORROSION AND INSTALLED FRAME REPAIRS AT STRINGER 4L, 5L, 6L, PER SRM 53-10-4 FIG 2. (M)SDR AALA990363Skin · corrodedTUL - FOUND CORROSION ON SKIN AROUND ICE LIGHT STRINGER 14R-17R STATION 720B-C. INSTALLED DOUBLER AT RIGHT ICE LIGHT CUTOUT PER SRM 53-30-3 PAGE 137-140 FIG 22 AND ECO 11697, DATED 3/3/99. (M)SDR AALA990333Skin · crackedTUL - FORWARD ENTRY DOOR LOWER HINGE CUT-OUT IS CRACKED. REPAIRED PER SB 727-53-0198 FIG 4. DOUBLER IS .063 INCH AISI 15-5PH HEAT TREATED TO 150-170 KSI CADMIUM PLATED. FASTENERS ARE BACB30KK6A AND BACB30KK8A. TST: 61,081.50 HOURS. CYCLES: 38,758. (X)SDR GAIA9930Floorbeam · corrodedDURING C-CHECK, FOUND FLOORBEAM LOWER CAP CORRODED OUT OF SRM LIMTIS AT STATION 1130, BL 0 TO LBL 24. REMOVED DAMAGED LOWER CHORD, FABRICATED REPAIR PARTS, AND INSTALLED IAW AIA EDR B2-06264, REV 'A'. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA99042Skin · corrodedDURING ROUTINE C-CHECK, CORROSION WAS FOUND AROUND AFT LAVATORY DRAIN, BOX STRUCTURE, AND SKIN. LOCATED AT STR 20, LEFT FS 1183. THE CORROSION WAS REMOVED AND IT WAS DETERMINED TO BE BEYOND LIMITS. REPAIR WAS CARRIED OUT IAW AIA ENGINEERING DEVIATION REPORTSDR GAIA99041Floorbeam · crackedDURING ROUTINE C-CHECK, A CRACK WAS FOUND ALONG THE FLOORBEAM, UPPER CAP AT FS 1130 LBL 45. THE REPAIR WAS CARRIED OUT IAW AIA ENGINEERING DEVIATION REPORT NR B2 06407 AND AIA NON-ROUTINE M40 53403. THIS REPAIR IS AFFECTED BY AD 98-26-21 AND WAS SENT TO THE SDR GAIA99040Beam · corrodedDURING ROUTINE C-CHECK, CORROSION WAS FOUND IN THE MLG BEAM AT NR 4 FLAP TRACK OUTBOARD ATTACH POINT. THE CORROSION WAS REMOVED AND IT WAS DETERMINED TO BE BEYOND LIMITS. INSTALLED OVERSIZED BUSHING PER BOEING IPC. THE REPAIR WAS CARRIED OUT IAW AIA ENGINEESDR GAIA99039Skin · damagedDURING C-CHECK, DAMAGE WAS FOUND ALONG THE OUTBOARD MID-FLAP LOWER SKIN. THE PART HAS A MILLED OPENING FOR AN ACCESS PANEL. THE NUTPLATE HOLES WERE DAMAGED. A REPAIR DOUBLER WAS FABRICATED FROM 2024-T3 BY .0100 INCH CLAD ALUMINUM. THE REPAIR WAS ACCOMPLISHSDR AALA990374Frame · corrodedTUL - FORWARD CARGO DOOR CUTOUT FORWARD LOWER CORNER FRAME WEB CORRODED STATION 560, STRINGER 26R. INSTALLED DOUBLER ON WEB PER SRM 51-40-2, DOUBLER 5.5 BY 4.25 INCH, 3 ROWS FASTENERS BACB3OMC8-6 W/BACC30M8 COLLARS MATERIAL 2024T3 .080. (M)SDR AALA990378Frame · wornTUL - TOP OF BELT FRAME HAS 2 EACH WORN SPOTS ABOVE STRINGER 27L FROM FASTENER PROTRUSION AT CARGO TIEDOWN CASTING, STATION 1090 AND 27L STRINGER. INSTALLED DOUBLER .071 INCH WITH 19 EACH .25 INCH HI-LOCKS PER SRM 51-40-3 PAGE 3 AND 9 .1875 INCH HI-LOCKS. THSDR AALA990350Stringer · crackedTUL - FOUND STRINGER 15R CRACKED AT END OF STRINGER FORWARD OF ICE LIGHT. HFEC TO CONFIRM CRACK, REMOVED CRACKED SECTION OF STRINGER 1.25 INCH. HFEC TO CONFIRM CRACK REMOVAL AND INSTALLED REPAIR, FILLER AND CHANNEL PER 53-10-3 PAGE 12-17. (M)SDR AALA990296Valve · defectiveMIA - FLT 2115 - DURING CLIMB-OUT, NR 1 BLEED OVER PRESSURE LIGHT ILLUMINATED. CREW RAN CHECKLIST AND AIR INTERRUPTED, RETURNED TO MIA AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND NR 1 ENGINE BLEED VALVE DEFECTIVE. REPLACED NR 1 ENGINE BLEED VALVSDR AALA990375Web · crackedTUL - FOUND CORROSION AND CRACKS ON UPPE RLOWER SIDE ANGLES AND WEB OF TAIL SKID ACT MOUNT RIB STATION 1213 LBL 18 TO RBL 18, LBL 30 TO RBL 30. REMOVED AND INSTALLED NEW ANGLES AND WEB PER SRM 51-10-1. (M)SDR AALA990366Frame · crackedTUL - FOUND STATION 420 FRAME CRACKED AT STRINGER 10L. REPAIRED DAMAGED FRAME STATION 420 STRINGER 10L WITH DOUBLER AS PER SRM 53-10-4 PAGE 3-6 FIG 1 SHEET 4. INSTALLED DOUBLER ONE GAUGE HEAVIER THAN ORIGINAL AND USED HI-LOCK .15625 DIAMETER. (M)SDR AALA990287Wire · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS IN COACH CABIN INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT JUMPER WIRE BETWEEN COACH AND FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA990286Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, THREE LIGHT SEGMENTS IN THE AFT CABIN EMERGENCY EXIT FLOOR PATH LIGHTS WERE INOPERATIVE. REPLACED EMERGENCY FLOOR PATH LIGHT STRIPS IN AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA990443Stringer · damagedTUL - TOOL MARK IN STRINGER 17 LEFT STATION 1243. INSTALLED TWO STRINGER REPAIRS AND SPLICES PER 53-10-3, DETAIL 1 FORWARD 8 AFT OF BELL FRAME. (M)SDR AALA990397Casting · crackedTUL - FOUND CRACK IN RADIUS AND VERTICAL AREA OF LEFT 760 CASTING (BEHIND RIB). REPAIRED LEFT 760 CASTING PER BOEING SERVICE BULLETIN 727-57-0112 REV 5 LARGE REPAIR. (M)SDR AALA990365Seat Track · corrodedTUL - FOUND CORROSION ON RIGHT OUTBOARD SEAT TRACK STATION 480 INBOARD, OUTBOARD LEGS AT FASTENER HOLES. REMOVED CORRODED SECTION OF SEAT TRACK. SPLICED IN NEW SECTION PER SRM 53-10-5 FROM STATION 480-560 RIGHT. (M)SDR AALA990281Accessory Unit · defectiveDFW - FLT 535 - EN ROUTE TUL-DFW - DURING GEAR RETRACTION, UNABLE TO RAISE GEAR HANDLE FROM OFF TO UP WITHOUT PULLING OVERRIDE TRIGGER. LEVER LATCH CIRCUIT BREAKER ON P6-3 WAS NORMAL. GEAR EXTENSION WAS NORMAL. AL OTHER SYSTEMS NORMAL. LANDED DFW WITHOUT INSDR AALA990364Skin · corrodedTUL - FOUND SKIN CORRODED ON EXTERIOR OF AIRCRAFT FROM STATION 1060 TO 1067 AT STRINGER 28L. CUTOUT DAMAGED SKIN. REPAIRED WITH DOUBLER PER SRM 53-30-3 FIG 3. (M)SDR AALA990360Skin · corrodedTUL - FOUND CORROSION ON EXTERIOR SKIN, STATION 708 STRINGER 28L. REPAIRED FUSELAGE SKIN PER SRM 53-30-3. (M)SDR AALA990359Skin · corrodedTUL - FOUND STATION 708 BETWEEN STRINGER 27L AND 28L FUSELAGE SKIN HAS CORROSION. REPAIRED FUSELAGE SKIN PER SRM 53-30-3. (M)SDR AALA990356Skin · corrodedTUL - FOUND SKIN CORRODED ON EXTERIOR OF AIRCRAFT. REPAIRED CORRODED THROUGH PORTION OF SKIN PER SRM 53-30-3. ALODINED AND PRIMED SKIN, PATCH AND SURFACE ON EXTERIOR OF SKIN PER SRM 51-10-2. (M)SDR AALA990355Stringer · corrodedTUL - FOUND STRINGER 28L CORRODED FROM STATIN 1050 TO 1070. CUT OUT DAMAGED STRINGER SECTION, AND INSTALLED STRINGER SPLICE PER SRM 53-10-3, FIGURE 1. (M)SDR AALA990353Stringer · corrodedTUL - FOUND CORROSION DOWN INSIDE STRINGER 27L AROUND DOME NUT, NUT PLATE STATION 702. REPAIRED FUSELAGE STRINGER PER SRM 53-10-3. (M)SDR AALA990352Stringer · corrodedTUL - FOUND HEAVY CORROSION ON STRINGER 28L, STATION 708. REPAIRED FUSELAGE STRINGER PER SRM 53-10-3. (M)SDR AALA990349Stringer · corrodedTUL - FOUND STRINGER 28R HAS CORROSION ON BOTTOM SURFACE AT FS 1040 TO 1070. REPAIRED STRINGER ACCORDING TO SRM 53-10-3. (M)SDR AALA990348Stringer · corrodedTUL - FOUND STRINGER 28R HAS CORROSION ON BOTTOM SURFACE AT FS 1040 TO 1070. REPAIRED STRINGER ACCORDING TO SRM 53-10-3. (M)SDR AALA990300Stringer · corrodedTUL - FOUND STATION 1177 BELLY SKIN CORRODED AT STRINGER 29 RIGHT. REMOVED CORRODED SECTION STRINGER 29R AT STATION 1177 AND SPLICED IN NEW STRINGER PER SRM 53-10-3 FIG 1. (M)SDR AALA990298Frame · bentTUL - FRAME BENT AT FLANGE AND WEB STATION 950F STRINGER 25L TO 26L. REPAIRED FRAME PER SRM 51-40-3 WITH .071 INCH 7075-T6 MATERIAL MS2047008 FASTENERS MS20470D6 FASTENERS IN WEB AND BACB30FQ6 FASTENERS IN FLANGE. (M)SDR AALA990297Frame · bentTUL - FRAME BENT AT FLANGE AND WEB STATION 970 BETWEEN STRINGER 25L AND 26L. FRAME REPAIRED PER SRM 51-40-3 WITH .071 INCH 7075T6 MATERIAL, MS2047008 FASTENERS, MS20970D6 FASTENERS IN WEB AND BACB30FQ6 FASTENERS IN FLANGE. (M)SDR EISA99031Pcu · leakingIMMEDIATELY AFTER TAKEOFF UNCOMMANDED RUDDER INPUT LEFT AND RIGHT. SYSTEM 'A' AND 'B' RUDDER POWER OFF RUDDER INPUT STOPS. REMOVED AND REPLACED UPPER RUDDER PCU IAW MM 27-20-141. (M)SDR AALA990582Frame · dentedTUL - FRAME 600 LEFT STRINGER 22L TO STRINGER 24L, 3 EACH DENTS IN UPPER LIP OF FRAME 2 EACH CUT OUT APPROX 2.25 INCH, ONE CUT OUT APPROX 3 INCHES. REPAIRED AREA. (M)SDR AALA990299Stringer · corrodedTUL - FOUND STATION 670 STRINGER 27L CORRODED. REPAIRED PER SRM 53-10-3. (M)SDR AALA990264Light · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH IN AFT CABIN INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT SECTION IN AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA990390Frame · dentedTUL - FOUND UPPER FLANGE OF BELL FRAME IS DENTED AT STATION 620 AT STATION 24L TO 25L. CUT OUT DAMAGED SECTION AND INSTALLED REPAIR DOUBLER PER SRM 51-40-3, 7075T6 .063, 16.5 INCH LONG, 3 ROWS RIVETS 1 ON TOP 2 ON SIDE WITH FORTY-EIGHT .1875 INCH D-RIVETS, FOSDR AALA990389Frame · dentedTUL - UPPER FLANGE OF BELL FRAME DENTED AT STATION 600 AND STRINGER 24 TO 25L. CUT OUT DAMAGED AREA AND INSTALLED REPAIR DOUBLER PER SRM 51-40-3, 7075T6 .063 SEVEN INCHES LONG, 3 ROWS RIVETS 1 TOP, 2 ON SIDE, NINTEEN .1875 INCH D-RIVETS, ONE .25 INCH D-RIVETSSDR AALA990387Frame · dentedTUL - SMALL DENT, UPPER FLANGE OF STATION 680 BELL FRAME, BELOW STRINGER 24L. INSTALLED DOUBLER PER SRM 51-40-3 7075T6.063, 3 ROWS OF RIVETS 2 ROWS SIDE SIXTEEN .1875 D-RIVETS, FOUR .25 INCH D-RIVETS. (M)SDR AALA990386Frame · dentedTUL - STATION 680 BELL FRAME DENTED AT STRINGER 23L. INSTALLED DOUBLER PER SRM 51-40-3 7075T6.063, 3 ROWS OF RIVETS 1 ROW TOP 2 ROWS SIDE 20 .1875 D-RIVETS. (M)SDR AALA990381Frame · dentedTUL - FOUND STATION 660 BELT FRAME DENTED AT 24L. INSTALLED DOUBLER (7075T-6, .063, 7.5 INCH LONG) 3 ROWS OF RIVETS (1 ROW TOP, 2 ROWS SIDE) WITH 20 EACH .1875 D-RIVETS PER SRM 51-40-3. (M)
Back to Boeing 727-223