Boeing 727-2J4
Service difficulty reports · 741
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7272J4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7272J4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA97228Support · corrodedDURING HEAVY MAINTENANCE VISIT, THE FLOOR SUPPORT U ANGLE CHANNEL WAS FOUND WITH ELONGATED FASTENER HOLES WITH CORROSION PRESENT. REMOVED, FABRICATED AND INSTALLED NEW SUPPORT IAW B727 SRM 51-10-6, 51-40-4, 53-10-1 AND MM 51-20-11.SDR SCNA97207Lamp · failedTHE LEFT FORWARD OVERWING EMERGENCY EXIT SIGN WAS FOUND TO HAVE BULBS INOPERATIVE. RELAMPED EMERGENCY EXIT SIGN, SIGN OPS CHECKED GOOD.SDR SCNA97259Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND SPACING FOR RIGHT INBD SEAT TRACK STATION 400 TO 520 AND LEFT OTBD SEAT TRACK STATION 344 TO 500 NOT MAINTAINING 1 INCH SPACING. REMOVED AND FABRICATED NEW SECTIONS OF SEAT TRACK IAW B727 53-10-5, 53-10-2, 51-30-5, 51-30-SDR SCNA97227Support · corrodedDURING HEAVY MAINTENANCE VISIT, THE FLOOR SUPPORT ANGLE AT STATION 303 RBL 44 WAS FOUND CORRODED. REMOVED, FABRICATED, AND INSTALLED NEW ANGLE IAW B727 SRM 51-40-3, 51-10-2, 51-30-2, AND MM 51-20-11.SDR SCNA97217Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON FLOORBEAM AT STATION 950F BETWEEN STRINGERS 27 AND 28 LEFT. CUT OUT CORRODED SECTION OF FRAME, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW B727 SRM 53-10-3, 53-10-4, AND 51-30-2.SDR SCNA97258Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON RIGHT SEAT TRACK AT STATION 720E. REMOVED AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-5, 51-10-2, AND MM 51-20-21.SDR SCNA97257Angle · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON FLOOR SUPPORT LOCATED AT STATION 1110, LBL 0 TO 60. FABRICATED AND INSTALLED REPAIR ANGLES IAW B727 SRM 53-10-8.SDR SCNA97254Support · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND FLOOR SUPPORT AT STATION 1110 TO 1130, LBL 18 CORRODED. REMOVED, FABRICATED AND INSTALLED NEW SUPPORT IAW B727 SRM 51-20-2, 51-10-1, 51-30-2 AND 51-20-4.SDR SCNA97249Skin · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND SKIN PILLOWING THRU RIVET PATTERN OF SKIN LAP 4 RIGHT FROM APPROXIMATELY STATION 700 TO 720. REMOVED, FABRICATED AND INSTALLED DOUBLER REPAIR IAW B727 SRM 53-30-3 AND 53-30-1.SDR SCNA97244Floorbeam · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE FLOORBEAM AT STATION 369 RBL 12 TO LBL 24 CORRODED. REMOVED 38 SECTION OF UPPER FLOORBEAM, FABRICATED AND INSTALLED CHORD, SUPPORT ANGLES, AND STRAPS IAW B727 SRM 53-10-8.SDR SCNA97243Seat Track · mis mfgDURING HEAVY MAINTENANCE VISIT, FOUND LEFT INBOARD SEAT TRACK AT STATION 460 - 520 NOT CONFORMING TO 1 SPACING. REMOVED, FABRICATED, AND INSTALLED SEAT TRACK IAW B727 SRM 53-10-5, 51-10-2, AND 51-30-2.SDR SCNA97242Seat Track · gougedDURING HEAVY MAINTENANCE VISIT, FOUND GOUGED SEAT TRACK FROM STATION 420 TO 460, RBL 55. REMOVED, FABRICATED, AND INSTALLED NEW SEAT TRACK IAW B727 SRM 51-30-2, 51-10-2, AND 53-10-5.SDR SCNA97264Rib · crackedDURING HEAVY MAINTENANCE VISIT, FOUND RIB LOCATED AT LEFT WING STATION 738.5 CRACKED ON THE UPPER FLANGE AT THE STRINGER 12 ATTACH POINT. REMOVED AND REPLACED RIB IAW B727 SERVICE BULLETIN 727-57-0127.SDR SCNA97263Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND SEAT TRACK CORRODED STATION 378, RBL 22. REMOVED AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-2, 53-10-5, AND 51-30-2.SDR SCNA97262Support · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON FLOOR SUPPORTS AT STATION 1030, RBL 12 TO LBL 12, AND LBL 24 TO LBL 65. REMOVED, FABRICATED, AND INSTALLED NEW SUPPORTS IAW B727 SRM 51-30-2, 51-10-1, 51-20-2, AND MM 51-20-11.SDR SCNA97261Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON AFT GALLEY SEAT TRACKS FROM STATION 1090 TO 1130, LBL 45. REMOVED AND INSTALLED NEW TRACK IAW B727 SRM 53-10-5, 51-30-2, 51-10-2, AND 51-10-1.SDR SCNA97256Floor Web · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORROSION UNDER FLOOR WEB AT STATION 360 TO 373, RBL 64. FABRICATED AND INSTALLED REPAIR DOUBLER IAW B727 SRM 51-40-2, 51-30-2, AND MM 51-20-11.SDR SCNA97253Support · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR SUPPORT AT STATIONS 344 TO 380, LBL 10 TO RBL 22. INSTALLED REPAIR IAW B727 SRM 53-10-8, 51-30-2, AND 51-20-1.SDR SCNA97251Floorbeam · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CABIN FLOORBEAM CORRODED AT STATION 380, RBL 12 TO 48. CUT OUT CORRODED AREA, FABRICATED AND INSTALLED REPAIR PER EO 97-583 AND SRM 53-10-8.SDR SCNA97250Bracket · crackedDURING HEAVY MAINTENANCE VISIT, FOUND LEFT HORIZONTAL STABILIZER L2 BALANCE PANEL CENTER SUPPORT BRACKET CRACKED AT RIVET HOLE LOCATION. REMOVED, FABRICATED, AND INSTALLED NEW BRACKET IAW B727 SRM 52-30-2 AND 51-10-1.SDR SCNA97245Angle · crackedDURING HEAVY MAINTENANCE VISIT, FOUND THE RIGHT WING TRAILING EDGE PANEL SUPPORT ANGLES (2 EACH) CRACKED AT SUPPORT STRUTS BETWEEN SPOILER ACTUATORS NUMBER 12 AND 13. REMOVED, FABRICATED, AND INSTALLED NEW ANGLES AND ROD ASSY PER B727 SRM 57-30-0, 51-30-2, 51SDR SCNA97232Stringer · corrodedDURING HEAVY MAINTENANCE VISIT, STRINGER 21R WAS FOUND WITH EXCESSIVE CORROSION ON THE END WHERE IT TERMINATES AFT OF FUSELAGE FRAME 344. REMOVED CORRODED SECTION, FABRICATED AND INSTALLED REPAIR SPLICE AND FILLERS IAW B727 SRM 51-30-2, 53-10-3 FIGURE 1 DETAISDR SCNA97231Support · corrodedDURING HEAVY MAINTENANCE VISIT, THE FLOOR SUPPORT EXTRUSION WAS FOUND CORRODED AT STATION 324-348, RBL 42. REMOVED, FABRICATED, AND INSTALLED NEW SUPPORT IAW B727 SRM 51-30-2 AND 51-40-3.SDR SCNA97230Angle · corrdedDURING HEAVY MAINTENANCE VISIT, THE FLOOR SUPPORT EXTRUSION WAS FOUND CORRODED AT STATION 312 RBL 34. REMOVED, FABRICATED, AND INSTALLED NEW ANGLE IAW B727 SRM 53-10-1, 51-10-6, 51-10-2, 51-30-2.SDR SCNA97220Stiffener · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE FLOORING UNDER THE RIGHT FORWARD LAV CORRODED FROM STATION 303 TO 312, RBL 45. REMOVED CORRODED STIFFENER, FABRICATED AND INSTALLED NEW STIFFENER IAW B727 SRM 53-10-2, 53-10-1, 51-40-3, 51-30-2, AND MM 51-20-11.SDR SCNA97212Sub Floor · corrodedDURING HEAVY MAINTENANCE VISIT, THE UNDER FLOOR PANEL FOR THE RIGHT FORWARD LAV WAS FOUND CORRODED BEYOND LIMITS AT STATION 312, RBL 44. REMOVED, FABRICATED, AND INSTALLED NEW SUB FLOOR IAW B727 SRM 51-30-2, 53-10-10, AND MM 51-20-11.SDR SCNA97234Frame · corrodedDURING HEAVY MAINTENANCE VISIT, THE FORWARD CARGO COMPARTMENT FRAME AT STATION 720E BETWEEN STRINGERS 27 AND 28 LEFT WAS FOUND WITH CORROSION. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS, FABRICATED AND INSTALLED REPAIR ANGLE IAW B727 SRM 53-10-4, 51-40-2 ANSDR SCNA97213Support · corrodedDURING HEAVY MAINTENANCE VISIT CORROSION WAS FOUND ON THE FLOOR SUPPORT AT STATION 1138, LBL 0 TO 15. REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT IAW B727 SRM 51-40-4, 51-30-2, AND MM 51-20-11.SDR SCNA97236Angle · corrodedDURING HEAVY MAINTENANCE VISIT, THE RIGHT FORWARD EMERGENCY EXIT HATCH HAS TWO CORRODED ANGLES. REMOVED, FABRICATED, AND INSTALLED NEW ANGLES IAW B727 SRM 51-10-2, 51-10-6, 51-20-01, 51-30-2 AND 51-30-8.SDR SCNA97219Angle · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORRODED BOTTOM WEB AND RETAINER ANGLES ON THE LEFT AFT EMERGENCY EXIT HATCH. REMOVED CORROSION ON WEB AND FOUND TO BE WITHIN LIMITS, REPLACED BOTH RETAINER ANGLES.SDR SCNA97218Angle · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON THE BOTTOM WEB AND RETAINER ANGLE FOR THE LEFT FORWARD EMERGENCY EXIT HATCH. CORROSION REMOVAL ON WEB WAS WITHIN LIMITS, BUT REMOVED AND REPLACED RETAINER ANGLE IAW B727 SRM 51-10-2, 51-10-6, AND 51-30-2.SDR SCNA97225Hat Section · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON HAT SECTION AT STATION 1138 RBL 42 TO RBL 60. FABRICATED AND INSTALLED NEW HAT SECTION IAW B727 SRM 51-40-3.SDR SCNA97211Support · corrodedDURING HEAVY MAINTENANCE VISIT, FLOOR SUPPORT AT STATION 380, RBL 12.09 WAS FOUND CORRODED. REMOVED, FABRICATED, AND INSTALLED NEW SUPPORT IAW B727 SRM 51-40-4, 51-10-2, AND MM 51-20-11.SDR SCNA97210Floor Beam · corrodedDURING HEAVY MAINTENANCE VISIT, FLOORBEAM AT STATION 380, RBL 10 TO RBL 24 WAS FOUND CORRODED ON THE UPPER PORTION. REMOVED ALL CORROSION, FABRICATED AND INSTALLED REPAIR ANGLES IAW B727 SRM 53-10-8, 51-30-2, 51-10-06, AND MM 51-20-31.SDR SCNA97198Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, THE SEAT TRACK BETWEEN STATIONS 1025 TO 1090, LBL 46 TO 47, WAS FOUND CORRODED. REMOVED, FABRICATED, AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-02 AND 53-10-03.SDR SCNA97235Floorbeam · corrodedDURING HEAVY MAINTENANCE VISIT, THE FLOORBEAM AT STATION 344 FROM ENTRY DOOR TO RBL 20 WAS FOUND WITH SURFACE CORROSION. REMOVED CORRODED T CAP, FABRICATED, AND INSTALLED NEW CAP IAW B727 SRM 53-10-1 AND 53-10-8.SDR SCNA97216Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND CORRODED SEAT TRACK AT STATION 370, LBL 42.8. REMOVED, FABRICATED, AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-1, 51-30-2, AND MM 51-20-11.SDR SCNA97208Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, SEAT TRACK AT THE FOLLOWING LOCATIONS WERE FOUND CORRODED: STATION 1070 TO 1130 LBL 56, STATION 1070 LBL 25, AND STATION 1110 TO 1130 LBL 46. REMOVED, FABRICATED, AND INSTALLED NEW SEAT TRACK IAW B727 SRM 51-20-2, 51-30-2, AND SDR SCNA97224Floorbeam · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE FLOORBEAM AT STATION 1110, RBL 10. CUT-OUT CORROSION, FABRICATED, AND INSTALLED REPAIR ANGLES AND STRAPS PER B727 SRM 53-10-8 FIGURE 3.SDR SCNA97209Support · corrodedDURING HEAVY MAINTENANCE VISIT, FLOORBEAM SUPPORTS AT THE FOLLOWING LOCATIONS WERE FOUND CORRODED: STATION 1050 TO 1110 LBL12, STATION 1070 LBL 45 - 63, AND STATION 1110 TO 1130 BL 0 - LBL 12. REMOVED, FABRICATED, AND INSTALLED NEW SUPPORTS IAW B727 SRM 53-10SDR SCNA97197Support · corrodedDURING HEAVY MAINTENANCE VISIT, FLOOR SUPPORT BETWEEN STATIONS 1050 TO 1070 AND 1110 TO 1130, LBL 12 WAS FOUND CORRODED. REMOVED, FABRICATED AND INSTALLED NEW SUPPORT IAW B727 SRM 51-30-02, 53-10-3, 51-40-4 AND B727 MAINTENANCE MANUAL 51-20-11.SDR SCNA97196Angle · wornDURING HEAVY MAINTENANCE VISIT, FLOOR SUPPORT ANGLE AT STATION 1070, LBL 45 TO 63, WAS FOUND WITH ELONGATED HOLES BY THE L-2 DOOR. REMOVED, FABRICATED AND INSTALLED NEW SUPPORT IAW B727 SRM 51-30-02, 53-10-1, AND B727 MAINTENANCE MANUAL 51-20-11.SDR SCNA97222Angle · corrodedDURING HEAVY MAINTENANCE VISIT, THE FLOOR SUPPORT AT STATION 405, BL 12.09 WAS FOUND CORRODED. REMOVED, FABRICATED, AND INSTALLED NEW ANGLE IAW B727 SRM 53-10-1.SDR SCNA97241Floorbeam · crackedDURING HEAVY MAINTENANCE VISIT, THE FLOORBEAM WEB AT STATION 950A TO 950B WAS FOUND CRACKED. REMOVED CRACKED ANGLE, FABRICATED AND INSTALLED NEW ANGLE IAW B727 SRM 51-20-1, 51-30-6, 51-10-2, AND MM 51-20-11.SDR SCNA97240Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, THE SEAT TRACK AT STATION 420-460 RBL 55 WAS FOUND CORRODED. REMOVED, FABRICATED, INSTALLED AND NEW SEAT TRACK IAW B727 SRM 53-10-2, 51-30-2 AND MM 51-20-11.SDR SCNA97239Support · corrodedDURING HEAVY MAINTENANCE VISIT, THE CABIN FLOOR SUPPORT ANGLE AT STATION 1030- 1148 LBL 12 WAS FOUND CORRODED. FABRICATED AND INSTALLED NEW FLOOR SUPPORT IAW B727 SRM 53-10-8.SDR SCNA97223Support · corrodedDURING HEAVY MAINTENANCE VISIT, THE FLOOR SUPPORT AT STATION 1070 LBL 26 TO LBL 43 WAS FOUND WITH SURFACE CORROSION. REMOVED AND REPLACED FLOOR SUPPORT ANGLE IAW B727 51-30-2 AND 53-10-1.SDR SCNA97201Floorbeam · crackedDURING HEAVY MAINTENANCE VISIT, THE FLOORBEAM WEB AT STATION 950A TO 950B WAS FOUND CRACKED. REMOVED, FABRICATED AND INSTALLED NEW WEB IAW B727 SRM 51-20-1, 51-30-6, 51-10-2 AND MAINTENANCE MANUAL 51-20-11.SDR SCNA97200Angle · crackedDURING HEAVY MAINTENANCE VISIT, THE CABIN FLOOR SUPPORT INTERCOSTAL WAS FOUND CRACKED BETWEEN FRAMES AT STATION 400 TO 420, LBL 5. REMOVED, FABRICATED AND INSTALLED NEW ANGLE IAW B727 SRM 51-20-1, 51-30-2 AND MAINTENANCE MANUAL 51-20-11.SDR SCNA97199Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, THE SEAT TRACK BETWEEN STATIONS 420 TO 460, RBL 55 WAS FOUND CORRODED. REMOVED, FABRICATED AND INSTALLED NEW SEAT TRACK IAW B727 SRM 53-10-2, 51-30-2, AND MAINTENANCE MANUAL 51-20-11.
Back to Boeing 727-2J4