Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023080975585Floor Panel · pulledFLOOR PANEL 241RF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241RF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0 PARA 1. A. NOTE AND DWG 146A5810 SHEET 4SDR SWAA2023080975586Floor Panel · pulledFLOOR PANEL 241TF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241TF IAW SRM 53-00-50-2R-0 AND DWG 146A5810 SHEET 467;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2023080975576Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241UF IAW SRM 53-00-50-2R-0 AND BOEING DWG:146A5810 ID:0470.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023080975587Floor Panel · pulledFLOOR PANEL 241VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241VF IAW SRM 53-00-50-2R-0 PAR. 5. S. (1) (A) - (D) AND BOEING DWG: 146A5810 ID: 0469.;[02] FINAL INSPECTION. JOB COMPLETE.<BR><BR>VERIFIED MESDR SWAA2023080975588Floor Panel · pulledFLOOR PANEL 241WF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241WF IAW SRM 53-00-50-2R-0 AND DWG 146A5810 SHEET 471;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2023080976089Tension Tie · corrodedCORROSION ON TENSION STRAP AT AFT CABIN BS1016+12 RBL18 WL208.<[01] REMOVED TENSION STRAP AT AFT CABIN BS1016+12 RBL18 WL208 PER SRM 51-40-02-0G-0.;[02] UPDATED MEASUREMENTS TABLE.;[03] SRM DOES NOT HAVE ALLOWABLE DAMAGE FOR CORROSION ON TENSION STRAP. OUT OF SDR SWAA2023080976090Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT CABIN BS986 LBL43 WL208.<[01] VERIFIED SRM 53-70-51-1A-1 IS APPLICABLE FOR ALLOWABLE DAMAGE TO SECT. 47 FLOOR STRUCTURE.;[02] CONCUR WITH APPLICABILITY OF SRM 53-70-51-1A-1.;[03] REMOVED CORROSION FROM UPPER FLANGE OF BS 986.5 FLSDR SWAA2023080976100Sill Drain · corrodedCORROSION ON FED MOP SILL BS294+9; BS317 - BS342 LBL56 WL208.<[01] VERIFIED APPLICABILITY FOR SRM 53-10-15-1A-1;[02] REMOVED CORROSION ALONG FED MOP SILL<BR>AT LBL56; WL208; BS294.5 + 10'; L: 2 X W:1'<BR>BS312 + 5'; L: 2.5' X W:1'<BR>BS312 + 9'; L: 1.5' X W:1'SDR SWAA2023080976098Sill Drain · corrodedCORROSION ON FSD MOP SILL BS294+7; BS326 - BS346 RBL56 WL208.<[01] VERIFIED APPLICABILITY OF SRM 53-10-15-1A-2;[02] REMOVED CORROSION ALONG FSD MOP SILL <BR>AT RBL56; WL208 BS 291.5 + 11' - BS312 + 10' L:20' X W:1'; REMOVED CORROSION ALONG FSD MOP SILL AT RBL5SDR SWAA2023080976099Support Angle · corrodedCORROSION ON FSD MOP SILL THRESHOLD SUPPORT ANGLE BS305 - BS323 RBL57 WL209.<REMOVED CORROSION ALONG FSD MOP SILL THRESHOLD SUPPORT ANGLE AT RBL57; WL209 BS 291.5 + 12' L:1.5' X W:1';<BR>BS312 L1:5' X W:1'; <BR>BS312 +5' L1:5' X W:1'; <BR>BS312 +8' L1:5' X W:1SDR SWAA2023080775892Panel · crackedCRACK ACCESS PANEL 561BB TRAILING EDGE AT LT WING 2023-431181<[01] TOOL USED CALIPER P/N 500-197-30 S/N:B20189527 DUE DATE 26 DEC23.;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV; S/N: 18196126; DUE DATE: 26-MAR-24.;[03] TOOL USED HOT BONDER P/N: HCS9200B-AV S/NSDR SWAA2023080775895Panel · crackedCRACK ACCESS PANEL 661BB TRAILING EDGE AT RT WING 2023-431184<[01] TOOL USED: HOT BONDER P/N: HCS9200B-AV; S/N: 18196126; DUE DATE: 26-MAR-24.;[02] TOOL USED HOT; BONDER P/N: HCS9200B-AV S/N: 18196126 DUE DATE: 26-MAR-24;[03] TOOL USED: SCALE: P/N:CR5200 S/N:8SDR SWAA2023080475893Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED BS 500D BTW STR 18R AND STR 19R WING-TO-BODY FAIRING SUPPORT STRUCTURE 2023-431183<[01] REPLACED SUPPORT ANGLE LOCATED BS 500D BTW STR 18R AND STR 19R WING-TO-BODY FAIRING SUPPORT STRUCTURE IAW B737-700 SRM 51-10-02; SRM 51-40-02SDR SWAA2023080476187Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED BS 500D BTW STR 18L AND STR 19L WING-TO-BODY FAIRING SUPPORT STRUCTURE 2023-431193<[01] REPLACED SUPPORT ANGLE LOCATED BS 500D BTW STR 18L AND STR 19L WING-TO-BODY FAIRING SUPPORT STRUCTURE IAW B737-700 SRM 51-10-02; SRM 51-40-02SDR SWAA2023071775840Web · crackedDURING DVI INSPECTION FOUND L/H VAPOR BARRIER WEB CRACKED AT STA 663 WL 167 LBL47<[01] EVALUATED DAMAGE; CRACKS ARE REPAIRABLE IAW B737 SRM 57-10-10-2R-2. TAP TEST GOOD; NO DELAMINATION NOTED. <BR><BR>CLEANED AND PREPPED REPAIR AREA IAW B737 SRM 51-70-04-2R-10SDR SWAA2023070675707Battery Pack · inoperativeR1 DOOR EMERGENCY LIGHT AND SECONDARY LIGHT INOP<[01] REMOVED AND REPLACED M1675 BATTERY PACK IAW AMM 33-51-06. OPERATIONAL TESTED SATISFACTORY AT THIS TIMESDR SWAA2023070675608Light · inoperativeCABIN RIGHT OVER WING EMERGENCY EXIT SIDE LIGHT PARTIALLY INOP<[01] RE-LAMPED CABIN RIGHT OVER WING EMERGENCY EXIT SIDE LIGHT REF AMM 33-51-01.SDR SWAA2023070675703Light · inoperativeLH OVERWING EMERGENCY EXIT EMERGENCY LIGHT INOP.<[01] REMOVED & REPLACED LH OVERWING EMERGENCY EXIT LIGHT REF. AMM 33-51-04. OPS CHECK OK.SDR SWAA2023070675720Battery Pack · inoperativeR1 DOOR OUTSIDE EMERGENCY EXIT LIGHT AND L1 OVER DOOR EMERGENCY EXIT LIGHT INOP.<[01] REPLACED M1674 BATTERY PACK IN ACCORDANCE WITH AIRCRAFT MAINTENANCE MANUAL 33-51-06; OPS CHECKED GOOD.SDR SWAA2023082975545Seat Track · crackedCRACK AFT CARGO BAY SEAT TRACK BS767 RBL13 WL 156<[01] CORRECTION TO TASK DETAIL SHOULD STATE ' CRACK AFT CARGO BAY CARGO TRACK BS767 RBL13 WL 156 ';[02] UPDATED MEASUREMENT TABLE.;[03] COMPLETED STEP 4.;[04] COMPLETED STEP 6;[05] ALL STEPS COMPLETED;[06] CRACSDR SWAA2023082974746Floor Panel · debondedFWD FLOOR PANEL 221BF UPPER SKIN AT AFT I/B CORNER IS DISBONDED.<[01] REPAIRED UPPER SKIN AT AFT I/B CORNER OF FWD FLOOR PANEL 221BF IAW SRM 53-00-50-2R-1.;[02] VERIFIED JOB COMPLETE.;[03] VERIFIED ALL STEPS COMPLETE.SDR SWAA2023082974743Floor Panel · pulledFWD FLOOR PANEL 231BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 231BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 51-10-02-0G-0 PARA 9.A.1.;[02] VERIFIED. CARD COMPLSDR SWAA2023082974745Floor Panel · pulledFWD FLOOR PANEL 232BF UPPER SKIN HAS AN AREA OF PULLED STRANDS.<[01] REPAIRED AREA OF PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 232BF IAW SRM 53-00-50-2R-1.;[02] VERIFIED ALL STEPS COMPLETE.;[03] VERIFIED MEASUREMENTS TABLE; JOB COMPLETE.;[04] VERIFIED ASDR SWAA2023082974751Floor Panel · pulledFLOOR PANEL 231XF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 231XF IAW SRM 53-00-50-2R-0.;[02] VERIFIED MEASUREMENTS TABLE.;[03] JOB COMPLETE.SDR SWAA2023082974748Floor Panel · pulledFLOOR PANEL 231YF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 231YF IAW SRM 53-00-50-2R-0.;[02] VERIFIED MEASUREMENTS TABLE; JOB COMPLETE.SDR SWAA2023082974749Floor Panel · pulledFLOOR PANEL 232SF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241UF WAS REPLACED WITH A NEWLY FABRICATE FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0. ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] VERIFIED MEASUREMENTS TABLE; JOB SDR SWAA2023082974750Floor Panel · pulledFLOOR PANEL 241BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241BF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0. ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] VERIFIED MEASUREMENTS TABLE; JOBSDR SWAA2023082974752Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241UF WAS REPLACED BY A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0. ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] VERIFIED MEASUREMENTS TABLE; JOB CSDR SWAA2023082974753Floor Panel · pulledFLOOR PANEL 242PF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 242PF IAW SRM 53-00-50-2R-0 AND BOEING DWG 144A5810 ID:0103.;[02] VERIFIED MEASUREMENTS TABLE; JOB COMPLETE.SDR SWAA2023082975546Sidewall Support · corrodedCORROSION AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS MULTIPLE AREAS AROUND NUT PLATE HOLES BS727C+19' TO BS767 RBL22 WL156<[01] CORROSION DAMAGE ON ACB R/H FLOOR TO SIDEWALL SUPPORT PLATE BS727C+19' TO BS767; RBL22;WL156 WAS FOUND TO BE OUT OF LIMITSDR SWAA2023082975542Sidewall Support · corrodedCORROSION AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE MULTIPLE AREAS AROUND NUT PLATE HOLES BS727D+10 TO BS787+5 LBL22 WL156<[01] VERIFIED MEASUREMENT TABLE.;[02] REPAIRED ACB LH FLOOR TO SIDEWALL SUPPORT; BS 727C+10 TO 787+12; AND INSTALLED REPAIR PARTSSDR SWAA2023082975543Shield · corrodedCORROSION AFT CARGO BAY SHIELD AFT OF CARGO DOOR HAS MULTIPLE AREAS AROUND NUT PLATE HOLES BS847 TO BS867 RBL22 WL163.5<[01] UPDATED MEASUREMENT TABLE.;[02] COMPLETED STEP 1;[03] COMPLETED STEP 4 <BR>VERIFIED MEASUREMENT TABLE.;[04] VERIFIED MEASUREMENT TABLE.SDR SWAA2023082975544Shield · corrodedCORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767+3 TO BS794 RBL22 WL156<[01] REMOVED AND REPLACED ACB SHIELD FWD OF CARGO DOOR BS 767 TO BS 787+6; RBL 22; WL 156 IAW SRM 51-40-02-0G-0; SRM 51-40-05; DWG#146A0081.;[02] VERISDR SWAA2023082975548Shield · corrodedCORROSION FWD CARGO BAY AFT SHIELD BS500+1 TO BS500+19 RBL22 WL156 HAS MULTIPLE AREAS AROUND NUT PLATE HOLES<[01] VERIFIED STEPS 4 AND 5.;[02] CORROSION ON FWD CARGO BAY AFT SHIELD BS500+1? TO BS500+19? RBL22 WL156 FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACSDR SWAA2023081574720Panel · debondedPANEL 193AR INNER SKIN PREVIOUS REPAIR IS DISBONDED. (MARKED)<[01] PANEL 193AR WITH INNER SKIN PREVIOUS REPAIR THAT'S DISBONDED AS MARKED WAS REPLACED WITH A SERVICEABLE PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 51-10-02-0G-0 PARA 9.A.1.;[02] VERIFIED CORRECTISDR SWAA2023081475666Panel · corrodedCORROSION: NOSE WHEEL WELL PANEL #114AC INB SIDE ALL AROUND. CORRECTION TO FAULT DESCRIPTION. CORROSION: NOSE WHEEL WELL PANEL #113AC INB SIDE ALL AROUND.<[01] REPLACED NOSE WHEEL WELL ACCESS PANEL 113AC REF. B737-700 AMM 53-14-01-420-801. ACCESS PANEL 113AC WSDR SWAA2023081475667Panel · corrodedCORROSION: NOSE WHEEL WELL ACESS PANEL # 114AC INTERNAL SIDE; CORROSION ALL AROUND.<[01] AFTER REMOVED CORROSION ON SOME AREAS FOUND CORROSION GOING THRU GASKET - O - SEAL CAVITY REF. B737-700 SRM 53-10-14-1A. DOOR WILL BE REPLACE;[02] REPLACED NOSE WHEEL WELLSDR SWAA2023080975569Floor Panel · damagedFWD CABIN FLOOR PANEL 221BF AFT O/B CORNER (TANG) IS BROKEN<[01] FWD CABIN FLOOR PANEL 221BF WITH AFT O/B CORNER (TANG) BROKEN WAS REPAIRED PER SRM 53-00-50-2R-1. ATTACHED CURE SHEETS TO THIS FAULT RECORD.;[02] VERIFIED CORRECTIVE ACTION 1;[03] VERIFIED CORRECSDR SWAA2023080975570Floor Panel · damagedFWD CABIN FLOOR PANEL 221GF FORWARD O/B CORNER (TANG) BROKEN<[01] COMPLETED STEPS 11 AND 12.;[02] FWD CABIN FLOOR PANEL 221GF O/B CORNER (TANG) REPAIRED IAW SRM 53-00-50-2R-6;[03] VERIFIED CORRECTIVE ACTION 2;[04] VERIFIED CORRECTIVE ACTION 2SDR SWAA2023080775397Flap · debondedCUSTOMER REQUEST - DEBONDED IB MAIN FLAP WEDGE PANEL LOWER SURFACE AT RT WING 2023-431125<[01] TOOL USED CALIPER P/N 500-197-30 S/N 15120589 DUE DATE 13 FEB 24;[02] THE DAMAGE WAS REPAIRED PER 737-700 SRM-57-53-01-2R-18 REPAIR 18 WITH A DEVIATION DUE TO THE RESDR SWAA2023080775373Angle · crackedCRACK ANGLE LOCATED INBOARD AUXILIARY TRACK ON SLAT 8 AT RT WING 2023-422561<[01] REPLACED ANGLE LOCATED INBOARD AUXILIARY TRACK ON SLAT 8 AT RT WING IAW B737-700 SRM 51-40-02. LENGTH OF CRACK:2.041?. TOOL USED CALIPER P/N: 500-752-20 S/N:B21015879 DUE DATE: 1SDR SWAA2023080475386Intercostal · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION 2023-431107<[01] INSTALLED NEW INTERCOSTAL AND FASTENERS LOC.FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM SDR SWAA2023080475382Intercostal · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT CENTER SECTION 2023-431108<[01] REPLACED INTERCOSTAL AND FASTENERS LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02-0G-0 AND SRM 51-10-SDR SWAA2023080475393Intercostal · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW RBL 24.75 TO RBL 45.5 AT CENTER SECTION 2023-431113<[01] REPLACED INTERCOSTAL AND FASTENERS LOCATED FLOOR STRUCTURE BS 540 BTW RBL 24.75 TO RBL 45.5 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-0SDR SWAA2023080475394Angle · crackedCRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 RBL 24.75 CENTER SECTION 2023-431116<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112031023; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112811019; DUE DATE: 25-JAN-24 AND SDR SWAA2023080475381Floor Support · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER 2023-431106<[01] OPEN FAULT HAS AN ERROR AND IS BEING CORRECTED BY RAISING A NEW FAULT; SEE TTG8Q00M1CBD;[02] TASK CARD COMPLETED <BR>FAULT HAS AN ERROR AND IS BEING CORRECTED SDR SWAA2023080475387Stiffener · crackedCRACK STIFFENER 2 INSPAR RIB 129.50 AT LT HORIZONTAL STABILIZER 2023-431111<[01] TOOL USED: EDDY CURRENT EQUIPMENT; P/N: NORTEC600D; S/N: 210138103; CAL DUE DATE: 02-MAY-24;[02] TOOL USED: EDDY CURRENT EQUIPMENT; P/N: NORTEC 500D; S/N: N500X1693P030456; DUE DASDR SWAA2023080475388Stiffener · crackedCRACK INSPAR RIB STIFFENER 2 STAB STA 129.50 AT RT HORIZONTAL STABILIZER 2023-431114<[01] TOOL USED P/N NORTEC 600D S/N 60009161631 DUE DATE 31/JAN/24;[02] TOOL USED EDDY CURRENT EQUIPMENT PN:NORTEC 600D; SN:210138103; DUE DATE:02-MAY-24;[03] TOOL USED EDDY CUSDR SWAA2023080475374Bracket · damagedELONGATED HOLE ON SUPPORT BRACKET LOCATED INBOARD LEADING EDGE AT INTERNAL CAVITY ACCESS PANEL 611AT RT WING 2023-422560<[01] REPLACED SUPPORT BRACKET LOCATED INBOARD LEADING EDGE AT INTERNAL CAVITY ACCESS PANEL 611AT RT WING IAW. B373-700 SRM 51-40-02-0G-0 ANSDR SWAA2023071875272Bracket · crackedDOT A24-07 RH WING I/B L/E WING TO BODY FAIRING / L/E SUPPORT STRUCTURE ANGLE CRACKED AT FASTENER HOLE. MARKED<[01] REMOVED CRACKED ANGLE IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW ANGLE IAW SRM 51-40-05-0G-0 AND BOEING DWG# 116A3110 ID:0005 REV:B. WORK PE
Back to Boeing 737-7H4