Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023053052696Vapor Barrier · crackedCRACK PROPAGATION 1.6' BEYOND EXISTING REPAIR<[01] COMPLIED WITH AS REQUIRED;[02] COMPLIED WITH AS REQUIRED;[03] C/W REPAIRSDR SWAA2023070563506Fitting · corrodedVERTICAL FIN FRONT SPAR FITTING AT STA 1016 L/H BOLT HAS A SPOT OF CORROSION.<[01] REMOVED AND REPLACED VERTICAL FINFRONT SPAR FITTINGAT STA 1016 L/H BOLT AS PER AMM 55-30-200-801 TORQUE WRENCH <BR> BC 175291 <BR> DUE DATE: 11/18/23;[02] REMOVED AND REPLACED VSDR SWAA2023070563504Sign · crackedLAVATORY B EMERGENCY EXIT SIGN CRACKED<[01] REMOVED AND REPLACED NEW EXIT SING AT LAVATORY B IN REF AMM 33-51-01-960-801-NG;[02] VERIFIEDSDR SWAA2023070552659Attach Angle · crackedB.S. 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IS CRACKED AT R.B.L. 45; W.L. 165.<[01] PARTIALLY COMPLETED STEPS 1 & 2;[02] REMOVED BS 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE FROM RBL 6 TO RBL 63; WL 165 IAW SRM 51-40-02-0G-0;[03] RECEIVED NEW ANSDR SWAA2023070352620Bracket · crackedRIGHT ECS BAY HAS CRACKED DUCT SUPPORT BRACKET (212A1116) ACCESS PANEL 192CR BS540+6 RBL8. MARKED<[01] REMOVED CRACKED R/H ECS BAY DUCT SUPPORT BRACKET AT BS540+6 RBL 8 AND REPLACED WITH NEW BRACKET PER SRM 51-40-02-0G-0 AND AIPC 36-13-01-01;[02] VERIFIED CORRSDR SWAA2023070352136Structure · corrodedCORROSION ON L1 DOOR MOP SILL AT STA 328+6; +7.5; & +14.5; WL 208.1; LBL 60.<[01] PART REPLACED ON FAULT TTG8Q00L8VCT;[02] VERIFIED MEASUREMENT TABLE<BR><BR>VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070352623Shield · corrodedFWD CARGO BAY SHIELD HAS CORROSION BS 500+13; RBL 26; WL 156<[01] PART HAS NO LIMIT FOR DAMAGE. BLEND IS 1'L X 1'W REMOVED 0.010. PART IS FOUND TO BE (OUT LIMITS) REPAIR BY REPLACEMENT. IAW SRM 51-10-02;[02] REMOVED AFT SHIELD FROM FWD CARGO IAW SRM 51-40-02;[SDR SWAA2023070352635Seat Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK RBL45 BS410;440;473 WL208.<[01] VERIFIED APPLCABILITY PER SRM 53-00-52-1A-1. REMOVED CORROSION FROM CABIN SEAT TRACK AT BS 440 RBL45 W208 L:3' W:.45' D:.25' ON CROWN FOUND SEAT TRCK TO BE OUT OF LIMIT PER SRM 53-00-52-1ASDR SWAA2023070352621Stringer · corrodedAREA AFT OF FWD CARGO BAY STR 23 IS CORRODED AT THE AFT FASTENER; STR 23; RBL 45<[01] REMOVED CORROSION ON FCB STRINGER 23R BS 539 L=0.500'X W=0.500'D=0.036' FROM ORIGINAL THICKNESS 0.036' DAMAGE FOUND TO BE OUT LIMITS IAW SRM 53-00-03-1A FIG 103 DETAIL B.[05]SDR SWAA2023070352637Seat Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK RBL45 BS500+4; BS500C+9 WL208.<[01] VERIFIED APPLCABILITY PER SRM 53-00-52-1A-1. REMOVED CORROSION FROM CABIN SEAT TRACK AT BS500+4 RBL45 W208 L:3' W:.45' D:.22' ON CROWN; FOUND SEAT TRACK TO BE OUT OF LIMIT PER SRM 53-0SDR SWAA2023070352626Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK RBL45 BS727C+16; 727E+8; 787+9 WL208.<[01] VERIFIED APPLCABILITY PER SRM 53-00-52-1A-1. REMOVED CORROSION FROM CABIN SEAT TRACK AT BS727C+16 RBL45 W208 L:3' W:.45' D:.25' ON CROWN; FOUND SEAT TRACK TO BE OUT OF LIMIT PERSDR SWAA2023070352641Seat · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK LBL25 BS371 WL208.<[01] VERIFIED APPLICABILITY FOR 737-700 SRM 53-00-52-1A-1.<BR>REMOVED CORROSION FROM PASSENGER CABIN SEAT TRACK AT LBL 25 WL 208 BS371 L: 2' W: .90' D:.060' ON WELL; FOUND SEAT TRACK TO BE OUT LIMITS PSDR SWAA2023070352642Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK LBL45 BS380; 473 WL208.<[01] VERIFIED APPLICABILITY FOR 737-700 SRM 53-00-52-1A-1.<BR>REMOVED CORROSION FROM PASSENGER CABIN SEAT TRACK AT LBL 45 WL 208 BS 380 L: 1' W: .90' D:.050' ON WELL; FOUND SEAT TRACK TO BE OUT LISDR SWAA2023062952125Floor Panel · pulledFLOOR PANEL 241BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF ALL OF THE DAMAGE; DECIDED TO FABRICATE A NEW PANEL WITH BMS4-23 TYPE II LOT 1525675-1 AND BMS5-107 CLASS 1 LOT AK2KP8383K-1 RESIN; CURED RESIN UNDER A HEAT LAMP USING THERMOMESDR SWAA2023062952126Floor Panel · pulledFLOOR PANEL 241CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF ALL OF THE DAMAGE; DECIDED TO FABRICATE A NEW PANEL WITH BMS4-23 TYPE II LOT 1525675-1 AND BMS5-107 CLASS 1 LOT AK2KP8383K-1 RESIN; CURED RESIN UNDER A HEAT LAMP USING THERMOMESDR SWAA2023062952127Floor Panel · pulledFLOOR PANEL 242BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 242BF FLOOR PANEL FROM BMS4-17 TYPE 6 LOT#1526676-1; LOCATED AND INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING HEAT LAMP AND THERMOMETER ASDR SWAA2023062952128Floor Panel · pulledFLOOR PANEL 241LF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF ALL OF THE DAMAGE; DECIDED TO FABRICATE A NEW PANEL FROM BMS4-23 TYPE II LOT 1525675-1; DETERMINED INSERT HOLE LOCATIONS; UPSIZED INSERTS HOLES INSTALLED INSERTS WITH BMS5-107 SDR SWAA2023062952129Floor Panel · pulledFLOOR PANEL 241MF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF ALL OF THE DAMAGE; DECIDED TO FABRICATE A NEW PANEL FROM BMS4-17 TYPE VI LOT 1526676-1; DETERMINED INSERT HOLE LOCATIONS; UPSIZED INSERTS HOLES INSTALLED INSERTS WITH BMS5-107 SDR SWAA2023062952130Floor Panel · pulledFLOOR PANEL 241PF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF ALL OF THE DAMAGE; DECIDED TO FABRICATE A NEW PANEL FROM BMS4-17 TYPE VI LOT 1526676-1; DETERMINED INSERT HOLE LOCATIONS; UPSIZED INSERTS HOLES INSTALLED INSERTS WITH BMS5-107 SDR SWAA2023062952131Floor Panel · pulledFLOOR PANEL 241RF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 241RF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 5 TABLE 5. MOST OF THE UPPER SURFACE HAS LARGE AREAS OF PULLED STRANDS OR DELAMINATION. AREAS EXCEED ALLOWABLE DAMAGE LIMITS 53-00SDR SWAA2023062952121Floor Panel · pulledFLOOR PANEL 241SF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 241SF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 5 TABLE 5. MOST OF THE UPPER SURFACE HAS LARGE AREAS OF PULLED STRANDS OR DELAMINATION. AREAS EXCEED ALLOWABLE DAMAGE LIMITS 53-00SDR SWAA2023062952122Floor Panel · pulledFLOOR PANEL 241TF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 241TF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 5 TABLE 5. MOST OF THE UPPER SURFACE HAS LARGE AREAS OF PULLED STRANDS OR DELAMINATION. AREAS EXCEED ALLOWABLE DAMAGE LIMITS 53-00SDR SWAA2023062952123Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 241UF FLOOR PANEL FROM BMS4-17 TYPE 6 LOT#1526676-1; LOCATED AND INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING HEAT LAMP AND THERMOMETER ASDR SWAA2023062952132Floor Panel · pulledFLOOR PANEL 241VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 241VF FLOOR PANEL FROM BMS4-17 TYPE 6 LOT#1526676-1; LOCATED AND INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING HEAT LAMP AND THERMOMETER ASDR SWAA2023062952133Floor Panel · pulledFLOOR PANEL 242NF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 242NF FLOOR PANEL FROM BMS4-17 TYPE 6 LOT#1526676-1; LOCATED AND INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING HEAT LAMP AND THERMOMETER ASDR SWAA2023062952134Floor Panel · pulledFLOOR PANEL 242QF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 242QF FLOOR PANEL FROM BMS4-17 TYPE 6 LOT#1526676-1; LOCATED AND INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING HEAT LAMP AND THERMOMETER ASDR SWAA2023062952629Stringer · crackedAFT AREA OF FWD CARGO BAY STR 25 IS CRACKED AT AFT FASTENER ; RBL 29<[01] EVALUATED CRACK MEASUREMENTS ON FCB STRINGER 25R BS 539 DAMAGE FOUND TO BE OUT LIMITS IAW SRM 53-00-03-1A FIG 103 DETAIL A;[02] VERIFIED APPLICABILITY FOR STR 25R IAW SRM 53-00-03-2R-1 FSDR SWAA2023062952630Stringer · crackedAFT AREA OF FWD CARGO BAY STR 26 IS CRACKED AT AFT FASTENER; LBL 25<[01] EVALUATED CRACK MEASUREMENTS ON FCB STRINGER 26L BS 539 DAMAGE FOUND TO BE OUT LIMITS IAW SRM 53-00-03-1A FIG 103 DETAIL A;10] LOCATED AND DRILLED REPLACEMENT STRINGER SECTION AND HAT SECSDR SWAA2023062952636Attach Angle · crackedFWD CARGO BAY INTERCOASTAL ATTACH ANGLE IS CRACKED BS 440; LBL28; WL 154<[01] REMOVED FWD CARGO BAY INTERCOASTAL ATTACH ANGLE BS 440 LBL28 WL154. LOCATED AND DRILLED NEW ANGLE P/N 143A7502U155 LOT: 1519478-4 PO: 907139/4. IAW SRM 51-40-02-0G-0; SRM 51-30-01-0GSDR SWAA2023062952137Intercostal · crackedCRACKED INTERCOSTAL AT STA 277+7 & 277+13.5; WL 208; RBL 1.<[01] REMOVED INTERCOSTAL FOR REPLACED BS 277 TO 794 WL 208 RBL 1.<BR>IAW SRM 51-40-02-0G-0;[02] LOCATED IN DRILLED NEW INTERCOSTAL BS 277 TO 294 W2L 208 RBL 1. IAW SRM 51-40-05-0G-0 <BR>OK TI INSTALL;SDR SWAA2023062952632Attach Angle · crackedPASSENGER CABIN FSD FWD LOWER ATTACH ANGLE BS292 RBL 54 WL 208 CRACKED<[01] REMOVED FSD FWD LOWER ATTACH ANGLE IAW SRM 51-40-02;[02] CERTIFY;[03] PASSENGER CABIN FSD LOWER ATTACH ANGLE TO BE OUT LIMITS PER SRM 51-10-02. RECEIVED NEW ANGLE FROM TOOL ROOM P/N 14SDR SWAA2023062952633Web · crackedPASSENGER CABIN FED FWD WEB BS294.5 STR 15 CRACKED<[01] UPDATED MEASUREMENT TABLE;[02] FOUND FED FWD WEB BS294.5 STR 15 CRACK TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS AVAILABLE;[03] REMOVED STRAP AT BS 294+1-303+2 STR 15 L/H ; AND ATTACHING CLIP AT BS294SDR SWAA2023062952644Frame · crackedPASSENGER CABIN FED UPPER FRAME BS 312 STR 5L CRACKED<[01] COMPLETE MEASUREMENT TABLE;[02] VERIFIED MEASUREMENT TABLE;[03] REPAIRED ON FAULT TTG8Q00L9MWU;[04] VERIFIED CORRECTIVE ACTION 3SDR SWAA2023062155560Shim · out of toleranceAAI: REF: NRC: G049597: EXISTING SEAT TRACK REPAIR SHIM HAS FASTENER HOLE WITH ZERO EDGE AT FWD SIDE OF THE REPAIR; STA 727B; LBL 45.5 2023-334567<[01] PERFORMED PERMANENT REPAIR LOCATED FLOOR BEAM UPPER CHORD AT BS 727B AND LBL 45.5. IAW B737-700 SRM 53-40-51SDR SWAA2023062052393Support · crackedAAI: MAIN CABIN FLOOR STRUCTURE SUPPORT HAS CRACK AT STA 540 BTW BL 0 AND RBL 24.75 2023-334563<[01] REPLACED FLOOR STRUCTURE SUPPORT AT STA 540 BTW BL 0 AND RBL 24.75 IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 143A5240 SHEET 14; REV -.;[02] REPLACED FLOOSDR SWAA2023053151961Battery Pack · inoperativeEMERGENCY EXIT LIGHTS CONNECTED TO BATTERY PACK M1673 INOP<[01] TROUBLESHOT EMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1673; FOUND BATTERY PACK INOP;[02] REPLACED BATTERY PACK M1675; PERFORMED GOOD TEST PER AMM 33-51-06-960-805;[03] VERIFIED CORRECTIVE ACTSDR SWAA2023053151962Battery Pack · inoperativeEMERGENCY EXIT LIGHTS CONNECTED TO BATTERY PACK M1674 INOP<[01] TROUBLESHOT INOP LIGHTS ASSOCIATED WITH M1674 TO INOP BATTERY PACK.;[02] REPLACED BATTERY PACK M1675; PERFORMED GOOD TEST PER AMM 33-51-06-960-805;[03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2. TASDR SWAA2023053151963Battery Pack · inoperativeEMERGENCY EXIT LIGHTS CONNECTED TO BATTERY PACK M1675 INOP<[01] TROUBLESHOT INOP LIGHTS ASSOCIATED WITH M1675 TO INOP BATTERY PACK.;[02] REPLACED BATTERY PACK M1675; PERFORMED GOOD TEST PER AMM 33-51-06-960-805;[03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2. TASDR SWAA2023052552194Handle · looseR2 DOOR ASSIST HANDLE LOOSE<[01] TIGHTENED R2 DOOR ASSIST HANDLE PER AMM 52-41-31SDR SWAA2023052552205Cover · looseCABIN EMERGENCY EXIT LIGHT COVER IS LOOSE AT 6ABC.<[01] SECURED CABIN EMERGENCY EXIT LIGHT COVER AT 6ABC PER AMM 33-51-03SDR SWAA2023052552311Slide · looseJ HOOK FOR FWD ENTRY DOOR SLIDE LOOSE.<[01] TIGHTENED J HOOK FOR L1 DOOR BY USING HAND PRESSURE TO CLOSE J HOOK PER SIPSDR SWAA2023052552179Light · inoperativeR/H OVERWING EXIT SIDEWALL LIGHT INOP<[01] RELAMPED PER AMM 33-51-01SDR SWAA2023052552180Light · inoperativeL/H OVERWING EXIT AFT EMERGENCY LIGHT INOP<[01] RELAMPED PER AMM 33-51-01SDR SWAA2023052552088Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK AT LOCATION M1673 (AFT LEFT SIDE)<[01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT LOCATION M1673 OPS CHECK GOOD PER AMM 33-51-06;[02] REMOVED BATTERY DUE TO FAILED CAPACITY TEST REPLACED WITH SERVICEABLE UNIT. OPS CHECK GSDR SWAA2023052552297Light · inoperativeR1 DOOR ESCAPE SLIDE EMERGENCY LIGHT INOP.<[01] RELAMPED R1 EXTERNAL SLIDE EMERGENCY LIGHT.<BR>IAW B737 MM 33-51-04SDR SWAA2023052552314Battery Pack · inoperativeMAIN ENTRY EXIT SIGN AND EXTERIOR EMERGENCY LIGHT INOP. R&R FWD R/H GALLEY EMERGENCY BATTERY PACK PER AMM 33-51-06. OP CK GOOD.SDR SWAA2023052552448Light · intermittentEMERGENCY LIGHTS INTERMITTENT<[01] PERFORMED EMERGENCY LIGHTS OPS CK AS PER AMM 33-51-00; OPS CK NORMALSDR SWAA2023070551974Panel · delaminatedPANEL#521WB DELAMINATE EDGE AT I/B FWD CORNER.<[01] REMOVED ; ACCOMPLISHED REPAIR AND REINSTALLED PANEL #521WB AT LEFT WING PER AMM 57-41-02-400-801 ; AMM 57-41-02-000-801 AND SRM 51-70-04-2R-6 PARA 4.DSDR SWAA2023062951868Floor Panel · brokenAFT CABIN FLOOR PANEL 241ADF HAS A BROKEN AFT O/B CORNER<[01] IDENTIFIED PANEL IAW SRM 53-00-50-0I-1 FIGURE 6. DAMAGE TO THE PANEL IS BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.B AND WILL BE REPAIRED IAW SRM 53-00-50-2R-4. REMOVED AN APPROX. 1.7SDR SWAA2023062952120Channel · crackedFWD ENTRY DOOR MOP SILL IS CRACKED AT B.S. 303; LBL 55; WL 207<[01] REMOVED FWD ENTRY DOOR MOP SILL IS CRACKED AT B.S. 277 - 360; LBL 55; WL 207;[02] RECEIVED FROM TOOL ROOM NEW FED MOPSILL P/N 141A8112-1.<BR>LOCATED; DRILLED AND COUNTERSUNK NEW FED MOPSILL IA
Back to Boeing 737-7H4