Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA12511494Fmc · malfunctionedFMC DISAGREE LIGHT CAME ON AFTER PUSH BACK. ACFT GROUNDED. ACCOMPLISHED QRH PROCEDURE. RESET SATISFACTORY.SDR ASAA12511484Skin · gougedFUSELAGE SKIN GOUGED BETWEEN STA 727G - 727F AT STRINGER 23 LEFT. ACFT GROUNDED. FOUND GOUGE TO BE OUT OF LIMITS IAW SRM 53-00-01. REMOVED AFT CARGO COMPARTMENT LT SIDEWALL PANEL IAW NG AMM 25-52-06-000-801. REMOVED DAMAGED AREA OF SKIN FABRICATED 1 EA REPAISDR ASAA12511493Control Unit · failedFUEL QTY IS NOT AUTOMATICALLY UPDATING IN FMS. ATTEMPTED FQIS BITE PER FIM 28-41 TASK 801 ON MCDU. FQIS BITE INOP MESSAGE SHOWED. PERFORMED FMCS BITE PER FIM 34-61 TASK 801 FQIS FAULTED ON EVERY LEG. REMOVED AND REPLACED FUEL PROCESSOR UNIT REF MM 28-41-81 OPSDR ASAA12511492Ecu · failedATTEMPTED T/C NG 49, EO 03483 1 "NG APU ECU SOFTWARE UPDATE TO VERSION 5". UPDATED FAILED SOFTWARE, LOCKED UP AND WON'T RESET APU IS NOW INOPERATIVE DUE TO APU ECU LOCKED UP. ACFT GROUNDED. R & R APU ECU & OPS CHECKED GOOD REF AMM 49-61-12.SDR ASAA12511490Ecu · failedWHILE ACCOMPLISHING TASK CARD, NG 49, EO 03483, APU ECU BITE PROCEDURE FAILED AFTER SOFTWARE UPDATE. ACFT GROUNDED. REPLACED APU ECU. OPS CHECKED GOOD. REF AMM 49-61-12.SDR ASAA12511489Autothrottle Sys · malfunctionedAUTOTHROTTLE INOPERATIVE, WON'T ARM. PERFORMED AUTOTHROTTLE OPS TEST REF MM 22-31-00-710-801. CURRENT STATUS & SERVO TEST PASSED NUMEROUS TIMES.SDR ASAA12511488Control Valve · malfunctionedFOLLOW UP TO RT PACK LT ILLUMINATING CAUSING FLIGHT DELAYS. ACFT GROUNDED. REPLACED RT TCV, REF MM 21 51 10. INSTALLATION/GROUND VERIFICATION TEST NORMAL IAW SAME.SDR ASAA12511487Control Valve · malfunctionedLEFT PACK ILLUMINATED ON RECALL EXTINGUISHES W/MASTER CAUTION RESET. ACFT GROUNDED. PACK CONTROLLER BITE SHOWS TCV FAULT. TROUBLESHOT IAW FIM 21-62, TASK 848. VERIFICATION TEST OF NR 1 TEMP CONTROL VALVE NORMAL.SDR ASAA12511468Apu · overtempAPU TEMPERATURE CONTINUES TO BE ABOVE THE ESTABLISHED TEMP ON DEMAND THRESHOLD. ACFT GROUNDED. REPLACED THE APU IAW MM 49-11-00 AND T/C 78349010.SDR ASAA12511481Acm · malfunctionedLEFT PACK LIGHT ILLUMINATED WITH MASTER CAUTION CLIMBING OUT OF 16 000'. THE LT "RAM DOOR FULL OPEN" LIGHT WAS ILLUMINATED. TRIP RESET EXTINGUISHED THE PACK LIGHT FOR 30 SECONDS THEN PACK LIGHT ILLUMINATED. THE LT PACK TEMP READ 32C AND CLIMBED TO 50C. PACSDR ASAA12511483Unknown · unknownWHEN STARTING THE LT NR 1 ENGINE IT TAKES 5 SEC FOR THE START VALVE OPEN LIGHT TO COME ON AS WELL AS 5 SEC BEFORE N2 ROTATION HAS STARTED WHEN START SWITCH MOVES TO OFF IT TAKES THE SV OPEN LIGHT 4 SECONDS TO GO OUT. NEXT FLIGHT CREW PERFORMED NR 1 ENG START SDR ASAA12511482Control Valve · malfunctionedRT PACK ILLUMINATES ON MASTER CAUTION RECALL, EXTINGUISHES ON RESET. ACFT GROUNDED. PERFORMED PACK LIGHT FIM REF 21-53-00-810 NO FAULTS FOUND. PERFORMED PACK ZONE CONTROL. BITE FOUND TEMP CONTROL VALVE. FAULT RESET FAULT IAW PACK ZONE TEMP BITE REF 21-61-0SDR ASAA12511469Sensor · malfunctionedAPU EGT HAS HISTORY OF INDICATING LOW AND ERRONEOUS. INDICATION ERRORS ARE SUSPECT. ACFT GROUNDED. R & R INLET TEMP SENOR REF AMM 49-61-31. OPS/BITE CHECKED GOOD REF AMM 49-61-00-700-801.SDR ASAA12511486Valve · failedFL 370, DUCT SPLIT LEFT 24 PSI RIGHT 44 PSI. PERFORMED NR 1 ENG BLEED AIR SYS HEALTH CHECK IAW MM 36-11-00. FOUND SEAL AND COUPLING AIR LEAK WHERE PRECOOLER UPSTREAM DUCT CONNECTS TO PRECOOLER. REPLACED SEAL. LEAK CHECKED GOOD IAW MM 36-12-01. DURING HEALTH SDR ASAA12511477Fmc · malfunctionedRT FMC FAILURE VTK FLAG F/O MAP WOULD NOT RESET AT FL380. ACFT GROUNDED. PULLED & RESET BOTH FMC COMPUTOR C/B VTK FLAG CLEARED, OPS NORMAL. PERFORMED FMC FIM TASK 801-34-61, NO CURRENT FAULTS. SYS VERIFIED GOOD. PERFORMED CDS FIM TASK 809-31-63, NO FAULTSSDR ASAA12511476Fmc · malfunctionedFMC DISAGREE LIGHT ILLUMINATED ON TAXI. ACFT GROUNDED. ACCOMPLISHED FMC RESET PROCEDURE IAW FIM 34-61-00-810-835, NO FAULTS NOTED.SDR ASAA12511480Exciter · failedNR 1 ENGINE HAS FUEL FLOW NO LIGHT OFF WITH RT IGNITION. ACFT GROUNDED. REMOVED NR 1 ENGINE RT IGNITER & INSPECTED NO FAULTS. REPLACED IGNITER REF AMM TASK 49-41-51 AND REPLACED EXCITER UNIT AS A PRECAUTIONARY REF AMM 74-11-01 ACCOMPLISHED GROUND VERIFICATIOSDR ASAA12511478Fuel Control · malfunctionedWHILE PERFORMING TC 78273000, FOUND FUEL CONTROL 73-10321, HMU FMV CONTROL CURRENT IS OUT OF RANGE. SHORT TIME FAULT NR 1 ENG. ACFT GROUNDED. REPLACED NR 1 ENG EEC IAW AMM 73-21-60-000-801 F00 AND 73-21-60-400-801 F00. PERFORMED TESTS LISTED IN THE POWER PSDR ASAA12511475Fmc · unknownF/O FMC INTERMITTENTLY WOULD NOT ALLOW TO BRING UP FIX TO TOP (D TO FIX). ACFT GROUNDED. OPS CHECK OF FMC GOOD ALL KEY INPUTS OPS NO FAULTS. SYS OPS NORMAL. REF MM 34-61-00.SDR ASAA12511471Fire Detector · inoperativeNR 2 ENG B SYSTEM, FIRE DETECTION INOPERATIVE. ACFT GROUNDED. ACCOMP ENG/APU FIRE DETECT CONTROL MODULE BITE IAW FIM TASK 26 10 00 810 801. ENG 2, LOOP B, CORE LT DETECT FAULT LOGGED. PERF FIM TASK 26-10-00-810-805. LT CORE DETECT ELEMENT RESISTANCE READSSDR ASAA12511474Fmc · malfunctionedFMC DISAGREE PRIOR TO TAKEOFF. ACFT GROUNDED. QRH PROCEDURE ACCOMPLISHED. CLEARED THE DISCREAPENCY.SDR ASAA12511473Indication Sys · malfunctionedRIGHT MAIN FUEL TANK LOST 400LBS OF INDICATED FUEL IN APPROXIMATELY 15-20 SECONDS. ONLY APU WAS IN OPERATION AT THE TIME. ACFT GROUNDED. IAW FIM 28-41-00-810-814. COMPLIED WITH INITIAL EVALUATION. CURRENT STATUS NO FAULTS. GROUND TEST PASS. SUMPED APPROXSDR ASAA12511472Fire Detector · failedAPU DETECTED INOPERATIVE LIGHT ON. ACFT GROUNDED. VERIFIED DISCREPENCY, ACCOMPLISHED FIM 26-10-00-810-801, FOUND TAILPIPE DETECTOR BAD AT 16540 OHMS. REPLACED TAILPIPE M1925 DET REF MM 26-15-01. ALL TESTS OPS CHECKED GOOD.SDR ASAA12511470Fire Loop · malfunctionedNR 2 ENGINE B SYSTEM, FIRE DETECTION INOPERATIVE. ACFT GROUNDED. UNABLE TO DUPLICATE. ACCOMPLISHED ENG/APU FIRE DETECT CONTROL MODULE BITE NO FAULTS. ACCOMPLISHED RESISTANCE CHECK NR 2 ENG FIRE DETECT "B" LOOP IAW AMM TASK 26-11-00-730-801 AND TASK 26-11-01-SDR ASAA12511479Hmu · failedDURING NR 1 ENGINE TEST VIBRATION SURVEY, ENGINE BEGAN TO SURGE AND STALL UNCOMMANDED WHILE APPROACHING 81 PERCENT N1 FOLLOWED BY MASTER CAUTION LIGHT ENGINE INDICATION ON THE 6 PACK FOLLOWED BY LOW OIL PRESSURE INDICATION AND "ENG FAIL" ILLUM PRI ENG DISP ENSDR ASAA12511461Cone · gougedDURING NR 1 ENGINE FAN LUBE FOUND DEEP GOUGE ON MATING SURFACE OF FRONT SPINNER CONE. ACFT GROUNDED. R & R FRONT SPINNER CONE ON NR 1 ENG REF MM 72-21-01-400-801-F00.SDR ASAA12511460Shim · wornDURING NR 1 ENGINE FAN LUBE FOUND ALL BLADE SHIMS MISSING MOLYDAG COATING. ACFT GROUNDED. R & R NR 1 ENGINE 24 FAN BLADE SHIMS. REF MM 72-21-02-400-801-F00.SDR ASAA1251459Seal · tornDURING NR1 ENGINE FAN LUBE FOUND 18 OF THE 24 BLADE PLATFORMS WITH TORN OR MISSING SEALS. ACFT GROUNDED. R & R COMPLETE SET OF 24 EA BLADE PLATFORMS ON NR 1 ENG, REF MM 72-21-02-400-801-F00.SDR ASAA12511458Battery · failedMAIN BATTERY SHOWS 27 VOLTS AND A CONSTANT CHARGE OF 3 AMPS. AUX BATTERY SHOWS 27 VOLTS AND A CONSTANT 2 AMP CHARGE. ACFT GROUNDED. R & R AND TESTED AUX AND MAIN BATTERY IAW MM 24-31-11. TEST PASSES OK FOR SERVICE.SDR ASAA1251457Warning Light · false activationHF 2 RADIO INDICATES FAILED IN BOTH ACTIVE & STANDBY SIDES. ACFT GROUNDED. ACCOMPLISHED HF OPS TEST REF MM 23- 11-00. OPS NORMAL.SDR ASAA12511456Warning Light · false activationON CLIMBOUT, ABOUT FL240 LEFT PACK LIGHT CAME ON. FOLLOWED QRH 2.7, DID A TRIP RESET LIGHT WENT OUT. AFTER 1 MINUTE, LEFT PACK LIGHT CAME BACK ON. FOLLOWED QRH & TURNED ISOLATION SWITCH TO CLOSE AND LEFT PACK OFF. PRESSURE CONTROLLER BITE TEST SHOWS NO FAUSDR ASAA12511455Shutoff Valve · failedJUST AFTER TAKEOFF, RT BLEED TRIP OFF LIGHT ILLUMINATED ANTI ICE OFF NORMAL BLEED CONFIGURATION. OUT OF 2000 FT TRIP RESET WAS PUSHED AND BLEED TRIP OFF LIGHT EXTINGUISHED RT DUCT PRESSURE WAS RE-ESTABLISHED AND DUCT PRESSURE WAS ABOUT EQUAL. DURING CLIMB, RSDR ASAA12511454Knob · inoperativeF/O FMC BRT ADJUST KNOB NOW WORKING PROPERLY WHEN YOU TOUCH IT CDU SCREEN GOES TO FULL BRIGHT OR FULL DIM. COULD NOT DUPLICATE WRITE UP. ADJUSTED UP AND DOWN F/O'S BRIGHT KNOB ON FMC CDU. SYS IS WORKING NML. NO HISTORY. PERFORMED LAMP TEST REF 34-61-01. SYS SDR ASAA12511452Unknown · unknownSTARTED APU BUT NO VOLTS OR FREQ. ELECTRICAL METERS BATTERY AND GALLEY POWER MODULE TESTS GOOD IW MM 24-21-53. GROUND VERIFICATION SUCCESSFUL.SDR ASAA12511451Valve · failedDURING CLIMB, PASSING FL290, NOTICED DUCT SPLIT 45L 15R PSI. AFTER LEVEL OFF SPLIT WENT AWAY 41 PSI L/R. NO SPLIT DURING REMAINDER OF FLIGHT NOTED. ACFT GROUNDED. R & R NR 2 ENG PRECOOLER CONTROL VALVE REF MM 36-12-02-000-801 AND 36-12-02-400-801. OPS CHECKSDR ASAA12511450Line · looseON CLIMBOUT RT DUCT PRESSURE READ 45 PSI, LT DUCT PRESSURE 22-23 PSI AS WE LEVELED AT OUR CRUSE ALT BOTH NEEDLES LEFT AND RIGHT READ 32-35 PSI WERE NORMAL. GROUND RAN ENGINE FOR 2 MIN AT 80 PERCENT N1 AND UNABLE TO VERIFY DISCREPANCY. FOUND LINE ON BLEED AIRSDR ASAA1251448Knob · detachedNR 1 MCDU BRIGHTNESS KNOB FELL OFF. GROUNDED YES. SECURED KNOB. OP'S CHECKED GOOD.SDR ASAA12511449Radar · malfunctionedWEATHER RADAR SHOWS "SPIKING" ALL QUADRANTS OF DISPLAY. SPIKING OCCURED AT CRUSE AS WELL AS DESCENT & AT ALL TILT & CALIBRATION SETTINGS. PREFORMED TASK 34-43-00-710-802-001, WXR SYS OPS TEST. NO PROBLEMS NOTED. OK FOR SERVICE.SDR ASAA12511447Autoland Sys · malfunctionedPRACTICE AUTOLAND KOAK WITH HGS MONITOR GOT APPROACH WARNING IN FLARE. HAD 12KTS X WIND. CHECKED FAULT REVIEW FCC B HAD NUMEROUS MMR FAULTS ON PERVIOUS LEG NOTHING BEFORE THAT. RESET BOTH SYS MMR2 CHECKED GOOD IAW AMM 34-31-42-400-801, LAND VERIFY TESTED GOSDR ASAA12511446Actuator · seizedLEFT "RAM DOOR FULL OPEN" LIGHT DOES NOT ILLUMINATE ON DESCENT AND LANDING. LEFT RAM DOOR ACTUATOR SEIZED STUCK FULLY EXTENDED. R & R LT INLET ACTUATOR REF AMM 21 51 12. OPS CKD GOOD.SDR ASAA12511453Control Panel · inoperativeF/O COURSE WINDOW INOPERATIVE, ACFT GROUNDED. CYCLED MCP NR 1 DC CIRUCIT BREAKER, DISPLAY CAME UP NORMALLY FOR A FEW SECONDS AND WENT BACK OUT AGAIN. REPLACED MCP REF MM 22-11-34, OPS CHECKED NORMAL. ACCOMPLISHED ALL MCP LWMP CHECKS PER CHECKLIST MM 22-0-01 SDR ASAA12511443Fmc · malfunctionedFMC DISAGREE, ACCOMPLISHED QRH PROCEDURE. OPS NORMAL.SDR ASAA12511442Intercostal · crackedINTERCOSTAL BS 312 TO 328 WL 201, LBL 40 CRACKED. R & R INTERCOSTAL.SDR ASAA12511441Connector · dirtyON PREFLIGHT, FOUND ENGINE NR 2 EGT DISPLAY BOX HIGHLIGHTED IN RED VERSUS, RESET RED BOX ALERT DUE TO EGT CONNECTOR CLEANING ON NR 2 ENG REF TSR905906, EGT SENSOR CLEANING. OPS NORMAL, REF AMM 71-00-00-740-801-FOO.SDR ASAA12511439Seal · leakingON CLIMBOUT RT DUCT PRESSURE READ 45PSI, LT DUCT PRESSURE READ 22-23 PSI. AS WE LEVELED AT OUR CRUISE ALTITUDES BOTH NEEDLES LT AND RT READ 335 PSI AND WERE NORMAL. LEAK CHECKED LINES FOUND LINE ON BLEED AIR REGULATOR LOOSE AND FITTING ON PRECOOLER CONTROL VASDR ASAA12511437Switch · malfunctionedON CLIMBOUT, STAB TRIM BECAME INOPERATIVE ON RUNNING QRH PROCEDURE FOUND STAB TRIM CONTROL CIRCUIT BREAKER POPPED. DIVERSION TIME: 28 MINUTES. DISCONNECTED ELECTRONIC CONNECTOR CAPT CONTROL CUTOUT SWITCH. CIRCUIT BREAKER REMAINS CLOSED WITH ELECTRONIC STAB SDR ASAA12511435Circuit Breaker · trippedHF 2 CIRCUIT BREAKER DISCOVERED POPPED ON PREFLIGHT. RESET HF 2 CIRCUIT BREAKER REF MM 20-60-01. HF 2 OPS CHECKED IAW MM 23-11-00-710-801 AND GROUND VERIFICATION TEST, OPS CHECKED NORMAL.SDR ASAA12511485Floorbeam · corrodedFORWARD CARGO PIT AFT FLOORBEAM CORRODED SEVERAL LOCATIONS. ACFT GROUNDED. R & R IAW SRM 51-40-05.SDR ASAA12511444Floorbeam · corrodedFWD CARGO PIT AFT FLOOR ATTACH ANGLE CORRODED, SERVERAL LOCATIONS. R & R IAW SRM 51-40-005.SDR ASAA12511440Igniter · failedNR 1 ENGINE UNABLE TO START ENGINE IGNITION SWITCH ON RT IGNITION. REPLACED NR 1 ENGINE RT IGNITER, REF MM 74-21-02. PASSES AUDIBLE TEST EEC BITE IGNITERS TEST IAW MM 74-00-00-750-801.
Back to Boeing 737-890