Boeing 757-225
Service difficulty reports · 1,988
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757225' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757225' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA000816Intercostal · crackedCLT - FOUND INTERCOSTAL CRACKED 1.5 INCH, STATION 660, STRINGER 14R. FABRICATED AND INSTALLED PER SRM 53-30-15. (M)SDR USAABB00076Charger · inoperativePHL - FOUND RIGHT INTERIOR EMERGENCY LIGHTS INOPERATIVE. FOUND BROKEN PIN IN POWER SUPPLY. REPLACED THE CHARGER AND BATTERY PACK. (M)SDR USAABB00101Fan · seizedLAX - FLT 49 - INBOUND TO LAX, PASSENGERS COMPLAINED OF A SMOKE SMELL. CREW COULD NOT FIND ANY ABNORMAL INDICATIONS. FLIGHT LANDED IN LAX WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND THE RIGHT CABIN RECIRCULATION FAN CIRCUIT BREAKER TRIPPED. AN ODOR WAS EVISDR USAABB00071Sign · inoperativeBDL - FOUND EXIT IDENTIFIERS AT THE L4 AND R4 DOORS INOPERATIVE. MAINTENANCE REPLACED BOTH LIGHT ASSEMBLIES. (M0SDR USAABB00066Warning System · activatedPHX - FLT 152 - CLIMBING THROUGH FL230, CREW RECEIVED THE RIGHT ENGINE OVERHEAT LIGHT AND THE EICAS MESSAGE R ENG OVHT. CREW SECURED THE BLEED. AFTER APPROXIMATELY FIVE MINUTES, THE LIGHTS EXTINGUISHED. FLIGHT RETURNED TO PHX AND LANDED WITH NO FURTHER INCISDR USAABB00068Battery · dischargedLAX - FOUND SEAT MOUNTED LOW LEVEL EMERGENCY LIGHTS AT ROWS 1 AND 4 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (X)SDR USAA000660Doubler · crackedCLT - FOUND DOUBLER CRACKED 1 INCH, INSIDE ACCESS 4336R, NR 1 PYLON CUTOUT. INSTALLED DOUBLER PER EA 67093. (M)SDR USAA000661Doubler · crackedCLT - FOUND DOUBLER CRACKED 1 INCH, NR 1 PYLON INSIDE ACCESS PANEL 433AL CUTOUT. INSTALLED DOUBLER PER EA 67094. (M)SDR USAA000662Skin · corrodedCLT - FOUND SKIN CORRODED .875 INCH BY .875 INCH, BS 1525, 0BL SKIN. INSTALLED DOUBLER PER EA 67081. (M)SDR USAA000610Angle · crackedCLT - FOUND TWO CRACKS IN ANGLE 2 INCHES, BS 310, LBL 23 JUST BELOW FLOORLINE. FABRICATED REPAIR ANGLE AND INSTALLED EA 67116. (M)SDR USAA000600Floorbeam · corrodedCLT - FOUND FLOORBEAM T-CAP CORRODED 1 INCH BY 1 INCH, BS 1661 LBL 22. REMOVED AND INSTALLED NEW FABRICATED SECTION PER SRM 53-00-51. (M)SDR USAABB00062Battery · dischargedLGA - FOUND EXIT IDENTIFIER LIGHTS AT DOORS L2 AND R2 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB00060Battery · dischargedLGA - FOUND EMERGENCY AISLE LIGHTS INOPERATIVE AT ROWS 4, 9, 13, 18, 26 AND 33. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB00061Light · inoperativeLGA - FOUND EMERGENCY AISLE LIGHT AT ROW 1 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAA000515Angle · crackedCLT - FOUND ANGLE CRACKED 2 INCHES, STATION 1215 TO 1217 TOP ANGLE OF SHEAR WEB. FABRICATED NEW SHEAR WEB ANGLE PER SRM 53-60-51. (M)SDR USAA000517Floor Support · corrodedCLT - FOUND FLOOR SUPPORT CORRODED 1 INCH BY 1 INCH, BS 1300-1320, LBL 22 FLOOR SUPPORT. INSTALLED NEW FABRICATED SUPPORT ANGLE PER SRM 51-10-00. (M)SDR USAA000516Seat Track · corrodedCLT - FOUND SEAT TRACK 1 INCH BY 1 INCH, BS 1640, 6 INCHES AFT SEAT TRACK. CORROSION LEVEL 1. INSTALLED NEW FABRICATED SECTION PER SRM 51-10-00. (M)SDR AWXA0000218Wire · brokenEMERGENCY LIGHT INOP AT SEAT ROW 20 ABC. REPAIRED BROKEN WIRE, OPS CK GOOD. RECOMMENDATION: CLOSE -- AC HAS SEVERAL WIRING REPAIRS IN UN-RELATED LOCATIONS.SDR USAABB00045Light · inoperativePHL - FOUND THE FLOOR LEVEL EMERGENCY LIGHT SYSTEM INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES AT ROWS 1, 4, 6, 26, 29 AND 30 AND THE LIGHT ASSEMBLY AT ROW 13. (M)SDR USAABB00044Battery · dischargedPHL - FOUND THE FLOOR LEVEL EMERGENCY LIGHT SYSTEM INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES AT ROWS 1, 4, 6, 26, 29 AND 33 AND THE LIGHT ASSEMBLY AT ROW 13. (M)SDR AWXA0000208Floor Support · corrodedC-CHECK, CORROSION, FWD PIT FLOOR SUPPORT CHANNEL FS 732 RBL 12 HAS EXCESSIVE MATERIAL LOSS. REMOVED DAMAGED AREA, INSTALLED NEW FILLER AND DOUBLER, TREATED AND PRIMED IAW ER 19-5330-00022-JST.SDR USAA000502Floorbeam · corrodedCLT - FOUND T-CAP FLOORBEAM CORRODED, BS 324, RBL TO RBL . REPAIRED PER EA 66826 ANDEA 66865. (M)SDR USAA000503Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 12 INCHES BY 2 INCHES, STATION 740-730, RBL 64 JUST INBOARD OF R2 DOORSILL. REPAIRED PER BOEING DWG 143N5410 AND SRM 51-40-10. (M)SDR USAA000504Floorbeam · corrodedCLT - FOUND BEAM T-CAP CORRODED 1 INCH BY 2 INCH, FLOORBEAM STATION BS 1681.8, 12 AREAS. REPLACED AFT GALLEY WEB PER SRM 53-60-51 AND 51-10-00. (M)SDR USAA000501Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .5 INCH BY .5 INCH, BS 1660, LBL 37. INSTALLED REPAIR ANGLE PER TR 53-15-02. (M)SDR USAA000487Intercostal · corrodedCLT - FOUND INTERCOSTAL CORRODED 2 INCHES BY 4 INCHES, STATION 365.25 TO STATION 403, RBL 24.7. REPLACED INTERCOSTAL PER SRM 51-40-00. (M)SDR USAA000482Angle · corrodedCLT - FOUND ANGLE CORRODED 1 INCH AND 2 INCH, STATION 1200 BETWEEN STRINGER 29L TO STRINGER 29R. CORROSION LEVEL 1. REPLACED ANGLE PER SRM 51-40-00. (M)SDR USAA000483Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 24 INCHES, STATION 345, BL 0 TO LBL 24. INSTALLED REPAIR T-CAP AND ANGLE PER TR 53-15-01. (M)SDR USAA000484Angle · corrodedCLT - FOUND Z-ANGLE CORRODED 1 INCH BY 2 INCH, DOOR L1 Z-ANGLE FASTENER HOLES. REPLACED Z-ANGLE PER SRM 51-40-00. (M)SDR USAA000485Intercostal · corrodedCLT - FOUND INTERCOSTAL 4 INCH BY 7 INCH CORROSION, STATION 335 TO STATION 345, DOOR L1. REPLACED INTERCOSTAL PER SRM 51-40-00. (M)SDR USAA000488Stringer · crackedCLT - FOUND STRINGER 16L HAS TWO CRACKS 1.5 INCH LONG, BETWEEN STATION 660 AND 640. INSTALLED REPAIR ANGLE PER SRM 53-00-03 AND 66830. (M)SDR USAA000489Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH, STATION 1681.8, REPLACED FLOORBEAM PER SRM 53-60-61 AND 51-40-00. (M)SDR USAA000481Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 2 INCH BY 63 INCHES, STATION 345, BL 0 TO R 1 SILL. REPLACED T-CAP PER TR 53-15-01. (M)SDR USAA000486Intercostal · corrodedCLT - FOUND INTERCOSTAL CORRODED 3 INCHES BY 5 INCHES, STATION 334, RBL 24.5 TO RBL 40. REPLACED INTERCOSTAL PER SRM 51-40-00. (M)SDR USAABB00040Battery · dischargedSFO - FOUND L4 EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAA000459Frame · corrodedCLT - FOUND FRAME CORRODED 2 INCHES BY 3 INCHES, LOWER FRAME OF CARGO DOOR FRAME. REPAIRED PER SRM 51-40. (M)SDR USAA000458Floorbeam · corrodedCLT - FOUND FLOORBEAM 20 INCH BY 2 INCH, STATION 324, FROM RBL 45 TO R1 SILL. REPAIRED PER EA 66865 AND EA 66826. CORROSION LEVEL 1. (M)SDR USAA00045903Frame · corrodedCLT - FOUND FRAME CORRODED 2 INCHES BY 3 INCHES, LOWER FRAME OF CARGO DOOR FRAME. REPAIRED PER SRM 51-40. (M)SDR AWXA0000174Intercostal · crackedC-CHECK, CRACKED WEB AT BS 661 STR 141L. REMOVED CRACKED INTERCOSTAL, PRIMED AND INSTALLED NEW INTERCOSTAL IAW B757 SRM 51-40-02 PG 2, SRM 51-20-01 PG 9, AND SRM 51-20-05 PG 1.SDR AWXA0000173Web · corrodedC-CHECK, CORROSION LEVEL 1 CORROSION ON WEB AT BS 1710 TO 1720 LBL 55 TO RBL 55. REMOVED OLD WEB AND FABRICATED NEW PART USING OLD PART AS TEMPLATE, ALODINED, PRIMED, AND INSTALLED IAW B757 SRM 51-40-8, SRM 51-40-5, AND 51-30-1.SDR AWXA0000172Floorbeam · corrodedC-CHECK, CORROSION LEVEL 1 ON TOP CHORD OF STA 1681 FLOORBEAM LBL 55 RBL 55 WL 208. REPAIRED BS 1681 FLOORBEAM IAW ER 19-5365-00046-JS2A.SDR AWXA0000171Frame · corrodedC-CHECK, CORROSION LEVEL 2, ON I/B CHORD OF LT CREASE BEAM STA 452 - 458, WL 208 AT FLOORBOARD HOLES. REMOVED DAMAGE, FABRICATED REPAIR PARTS IAW B737 SRM 51-70-12, ALODINED, PRIMED AND INSTALLED REPAIR PARTS IAW B757 SRM 53-30-13. MATERIAL USED BAC1515-553SDR AWXA0000170Floorbeam · corrodedC-CHECK, FLOORBEAM AT BS 740 LBL 55, LBL 58 WL 208 CORRODED. REMOVED DAMAGED SECTION OF FLOORBEAM, FABRICATED REPAIR PART, ALODINED, PRIMED, PAINTED, INSTALLED PARTS IAW B757 SRM 53-00-51 FIG 203.SDR AWXA0000169Frame · corrodedC-CHECK, LEVEL 2 CORROSION, CREASE BEAM AT BS 724 LBL 68.5 WL 208. FOUND CORROSION OUT OF LIMITS. INSTALLED NEW CREASE BEAM IAW B757 SRM 51-40-02 PG 1-4. REMOVED CREASE BEAM AT BS 665 - 755 LBL 68.5 WL 208.SDR USAA000441Intercostal · corrodedCLT - FOUND INTERCOSTAL CORRODED 3 INCHES BY 6 INCHES, BS 365.5 TO 403, RBL 45.5. FABRICATED NEW PART PER SRM 51-40-00. (M)SDR USAA000442Floorbeam · corrodedCLT - FOUND FLOORBEAM 2 INCH BY 63 INCH, BS 365 BL 0 TO R1 DOOR SILL. REPAIRED DOUBLER T-CAP PER TR 53-15-01. CORROSION LEVEL 1. (M)SDR USAA000443Floorbeam · corrodedCLT - FOUND FLOORBEAM 3 INCH BY 14 INCH, STATION 377.7, BL 0 TO RBL 15. REPAIRED DOUBLER AND T-CAP PER TR 53-15-01. CORROSION LEVEL 1. (M)SDR USAA000440Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED 2 INCHES BY 2 INCHES, AT LBL 24, BETWEEN STATION 377/395. REPLACED SEAT TRACK PER SRM 53-00-52 AND 51-10-00. CORROSION LEVEL 2. (M)SDR USAA000432Seat Track · corrodedCLT - FOUND SEAT TRACK CRACKED 5 INCHES, LBL 46, BS 1635 TO 1640 SEAT TRACK. INSTALLED NEW SEAT TRACK PER SRM 51-40-02. CORROSION LEVEL 1. (M)SDR AWXA0000154Floorbeam · corrodedC-CHECK, CORROSION LEVEL 2 ALL ALONG FLOORBEAM AT STA 1640 RBL 17 LBL 20. REMOVED AND REPLACED FLOORBEAM IAW ER 19-5310-00018 RC1.
Back to Boeing 757-225