Boeing 757-23N
Service difficulty reports · 1,081
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75723N' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75723N' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AMTA200700477Tire · damagedUPON AC ARRIVAL FOUND NR 4 MAIN TIRE MISSING 80 PERCENT OF THE CAP. REMOVED AND REPLACED NR 4 MLG TIRE AND WHEEL IAW MM 32-45-01-4. (K)SDR AMTA200700476Wire · disconnectedROWS 10 THRU 12 EMERGENCY FLOOR TRACK LIGHTING INOPERATING. RECONNECT WIRES TO LIGHT ASSY AT ROW 12. OPS CHECK GOOD. (K)SDR AMTA200700474Coupler · unserviceableRT HF RADIO WILL NOT TUNE (CONTINUOUS TONE). REMOVED AND REPLACED RT HF COUPLER IAW MM 23-11-01-4, OPS CHECK OK.SDR AMTA200700463Shutoff Valve · unserviceableEICAS MSG L ENG BLD OFF DISPLAYED. LT ENG BLD AIR OFF LGT ILLUM WITH ENG RUNNING AND SW ON. DUCT NORM. JUMPERED RFCC NO HELP, REMOVED AND REPLACED NR 1 ENG PRESSUE REGULATING SHUTOFF VALVE IAW MM 36-11-09-002-008, OPS CHECKS NORMAL. (K)SDR AMTA200700459Battery · unserviceableFWD L/L EMERGENCY LT INOPERATIVE. REPLACED BATTERY PACK CHECKS NORMAL. (K)SDR AMTA200700458Valve · unserviceableEICAS MSG L PACK OFF DISPLAYED. PACK OFF LIGHT ILLUMINATED. LIGHTS FAILED TO EXTINGUISH WHEN PACK RESET SW PUSHED. PACK OPPERATES NORMAL. REPLACED LT FLOW CONTROL VALVE, OPS CHECK GOOD. (K)SDR AMTA200700430Structure · corrodedCORROSION ON LT AFT PIT CATWALK, STWS 1200-1310 AROUND SCREW HOLES. REMOVED CORROSION SRM 51-10-02, FOUND 1256-1260 AND 1280-1285 OUT OF LIMITS, SRM 53-00-53-1A. REPAIRED OUT OF LIMIT AREAS IAW SRM 53-60-53-2R AND 51-70-11-0G TREATED SRM 51-20-01. (K)SDR AMTA200700444Apu · auto shutdownAPU AUTO SHUTDOWN WHILE AT GATE. INTEROGATED ECU, NO FAULTS FOUND FOR CURRENT OR PREVIOUS SHUTDOWNS, STARTED APU NORMAL START. (K)SDR AMTA200700443Computer · unserviceableEICAS MSG L FMC FAIL DISPLAYED. (L) FMC BAD, REMOVED AND REPLACED LT FLIGHT MANAGEMENT COMPUTER IAW MM 34-61-01-4, OPS CHECK`S NORMAL. (K)SDR AMTA200700436Floorbeam · corrodedCORROSION ON BEAM FLOOR SUPPORT UPPER CAP LOWER SURFACE AT BS 377.7, LBL 61. REMOVED CORROSION, SRM 53-00-51-1A FOUND AREA OUT OF LIMITS SRM 53-00-51-2R-3 AND SRM 51-40-02. (K) REMOVED AND REPLACED FLOORBEAM UPPER CAP STATION 377.7 LBL 65 IAW SRM 53-00-51-2SDR AMTA200700439Floorbeam · corrodedFLOORBEAM STA 377.7, RBL 3, LBL 30, AREAS AROUND 8 EACH NUTPLATES ARE CORRODED. REMOVED CORROSION ON FLOORBEAM STA 377.7, RBL 3 - LBL 30 IAW SRM 53-00-51. FOUND SECTION AT LBL4 OUT OF LIMITS REPLACED FLOORBEAM UPPER CHORD IAW SRM 52-00-51, 2R AND SRM 51-40-0SDR AMTA200700433Floor Support · corrodedCORROSION ON FLOOR SUPPORT AT STA 1670, RBL 57. REMOVED CORROSION SRM 53-00-51-1A, FIG 101, FOUND TO BE OUT OF LIMITS SRM 53-00-51-1A. REMOVED FLOOR SUPPORT STA 1660-1680, RBL 57, SRM 51-40-02. REPLACED FLOOR SUPPORT SRM 51-40-05 AND 51-40-02. (K)SDR AMTA200700432Floor Support · corrodedCORROSION ON FLOOR SUPPORT AT STA 1656, RBL 57. REMOVED CORROSION SRM 53-00-51-1A. FOUND OUT OF LIMITS IAW SRM 53-00-51/ REMOVED AND REPLACED FLOOR SUPPORT AT STS 1540-1660, RBL 57, IAW 51-40-02 AND 51-40-05. (K)SDR AMTA200700431Floor Panel · corrodedCABIN FLOOR PANEL AT STA 310-350, LBL 22 HAS HEAVY CORROSION, OUT OF LIMITS. FAB NEW PANEL IAW DRWNG 141N5369. (K)SDR AMTA200700429Channel · corrodedCORROSION UNDER NUTPLATES, 7 EACH ON CHANNEL LOCATED AT STA 14-20-1440, RBL 20-1440. RBL 20 AFT CARGO PIT ENTRY AREA. REMOVED CORROSION SRM 51-10-53. FAB NEW CHANNEL IAW DRWG 146N5391. REPLACED WITH NEW CHANNEL SRM 51-40-02 TREATED SRM 51-20-01 AND MM 51-2SDR AMTA200700423Structure · corrodedCORROSION ON LT AFT PIT CATWALK, STA 1400-1530, AROUND SCREW HOLES LBL 20. BLENDED CORROSION ON LT AFT PIT STS 1400-1530, AROUND SCREW HOLES, LBL 20. TREATED AND PRIMED IAW SRM 51-20-01. (K)SDR AMTA200700427Display · inoperativeCAPT`S CDU WENT BLANK AFTER T/O AND REMAINED BLANK. REMOVED AND REPLACED CAPT`S CDU IAW AMM 34-61-02-422-035, OPS CHECK GOOD.SDR AMTA200700413Charger · malfunctionedEICAS MSG APU BAT CHARGER DISPLAYED WITH APU DISCH LGT EXTING. T/S IAW FIN 24-31-00, BLOCKS 1 AND 2, SYSTEM IS OK. (K)SDR AMTA200700407Mount · corrodedLAV C AFT IB MOUNT AT FS 1320, LBL 23 CORRODED. MOUNT FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A FIG 101 SHEET 3 DETAIL VI SECTION B-B REPLACED MOUNT AT LAV C IAW 51-40-01.(K)SDR AMTA200700403Floor Panel · corrodedCORROSION ON LT AFT PIT CATWALK STA 1310-1400, AROUND SCREW HOLES LBL 20. FOUND PANEL TO BE OUT OF LIMITS IAW 53-00-53. REMOVED AND REPLACED IAW SRM 51-40-02 TREATED AND PRIMED AND TOP COAT SRM 51-21-10-1 FROM FS 1200 TO 1640. (K)SDR AMTA200700399Slide · unwanted deployR-1 DOOR SLIDE INFLATED IN FWD GALLEY. REPLACED DOOR SLIDE IAW W/C 222R2505. (K)SDR BB07065Check Valve · chatteringFLIGHT 728, PHL-GLA: CREW REPORTED A RHYTHMIC KNOCKING SOUND IN THE AREA OF SEAT 13A. FLIGHT RETURNED TO PHL. MAINTENANCE REPLACED THE APU CHECK VALVE.SDR AMTA200700382Structure · brokenFOUND FLOOR STRIP BROKEN IN LT TUNNEL BESIDE NLG BOX STATION 377, LBL 24. REMOVED FLOOR STRIP DAMAGED IAW SRM 51-70-11 FIG 1 FROM STATION 367 TO 377. FABRICATED NEW FLOOR STRIP IAW SRM 51-70-11 FIG 1. TREATED AND PRIMED IAW SRM 51-20-01. INSTALLED REPAIR ISDR AMTA200700385Intercostal · corrodedSTA 330-340, LBL 21, FLOORBEAM INTERCOSTAL LARGE AREA OF CORROSION AND 4 EA DRILLED OUT FASTENERS. REMOVED CORROSION AT LBL 21, STA 330-360, AREA FOUND WITHIN LIMIT, ORG MAT .125, REMOVED .006 IAW SRM 53-00-01 TREATED AND PRIMED IAW SRM 51-20-01, REMOVED 4 EASDR AMTA200700386Transceiver · unserviceableRT HF TRANSMISSION AND RECEPTION INOPERATIVE. AT ALL CREW STATIONS. REMOVED AND REPLACED RT HF TRANSCEIVER IAW AMM 23-11-03-401. OPS CHECK GOOD. (K)SDR AMTA200700372Radar · malfunctionedWX RADAR RETURNS HEAVY NOISE AT ALL TILT SETTINGS. OPERATED WXR COULD NOT DUPE, BITE SHOWS NO FAULTS. REPLACED WXR RT IAW AMM 34-43-01-4. WXR CHECKS NORMAL. (K)SDR AMTA200700371Controller · malfunctionedRT WINDOW HEAT INOP LIGHT ILLUMINATED SEVERAL TIMES DURING CLIMB. REMOVED AND REPLACED WINDOW HEAT CONTROLER IAW MM 30-41-01-4, OPS CK GOOD. (K)SDR AMTA200700370Charger · unserviceableEICAS MESSAGE (APU BTY CHARGER). REMOVED AND REPLACED (APU BATTERY CHARGER) IAW MM CH 24-31-04, OPS CHECK GOOD. (K)SDR AMTA20070368Circuit Breaker · trippedAPU AUTO SHUTDOWN WHEN APU ELECTRIC SELECTED. GROUND POWER SOURCE CONNECTED TO AC APU BATTERY BUSS CB POPPED. RESET CB AND REMOVED GROUND POWER SOURCE CB STAYS SET. (K)SDR AMTA200700364Charger · inoperativeEGGRESS LIGHTING INOPERATIVE (C) ZONE RT SIDE. REMOVED AND REPLACED AFT GALLEY BATTERY PACK CHARGER IAW MM 33-57-07, OPS CHECK GOOD. (K)SDR AMTA200700363Battery Pack · inoperativeEGRESS LIGHTING INOP (B) ZONE LT SIDE. REMOVED AND REPLACED BATTERY PACK OVERHEAD AT L-2 DOOR, (B) ZONE EGGRESS LIGHTING OPS CHECKS NORMAL IAW 33-51-07. (K)SDR AMTA200700360Transceiver · malfunctionedRT HF RADIO DOES NOT CHANNELIZE ONLY ABOUT A 15 SECOND LOUD HUM FOLLOWS CHANNELIZATION ATTEMPT. REMOVED AND REPLACED TRANSCEIVER OPS CHECK OK IAW MM 23-11-03. (K)SDR AMTA200700340Transceiver · inoperativeRT HF RADIO INOPERATIVE. UNREADABLE ON ALL FREQUENCIES. RT HF CKD GOOD ON GROUND. CONTACTED SFO, TRANSMIT AND RECEIVE GOOD. OPS CK IAW MM 23-11-00-5. SWAPPED TRANSCEIVERS FOR T/S. LT NOW PN 0964-0452-022, SN 0326. RT NOW 0964-0452-012, SN XK516D1-01235.SDR BB07052Probe · intermittentFLIGHT 724, PHL-SNN: AFTER TAKEOFF, CREW REPORTED THAT THE RIGHT FUEL QUANTITY GAUGE WAS INOPERATIVE AND RECEIVED AN INTERMITTANT FUEL QUANTITY STATUS MESSAGE. FLIGHT RETURNED TO PHL. MAINTENANCE FOUND THE RIGHT FUEL COMPENSATOR PROBE INTERMITTANT. REPLACESDR AMTA200700336Lens · missingRED EGRESS LENS AND 1 WHITE EGRESS LENS MISSING BY R-2 DOOR. REPLACED 1 RED AND 1 WHITE EGRESS LENS BY R-2 DOOR. (K)SDR AMTA200700325Coupler · inoperativeHF TRANSMISSION INOPERATIVE AT ALL CREW STATIONS. REMOVED AND REPLACED LT HF COUPLER, OPS CHECK GOOD IAW AMM 23-11-01-4. (K)SDR AMTA200700326Unknown · unknownPILOT REPORTS EICAS MSG (L ENG. LOOP 1 ). PERFORMED TROUBLESHOOTING IAW FIM 26-11-00. CLEARED MSG AC OK FOR SERVICE. (K)SDR AMTA200700319Computer · inoperativeRT FMC INOPERATIVE. (CDU`S OPS NORMAL). REMOVED AND REPLACED RT FMC. OPS CKD GOOD, IAW AMM 34-60-00. (K)SDR AMTA200700311Fmc · malfunctionedON PUSH BACK, RT ENG STARTED. FMC LIGHT AND FMC MSG TURNED RT THEN BACK TO LT FMC SCREEN BLANK. (LT FMC). PERFORMED BITE ON LT FMC NO DEFECTS NOTED. (K)SDR AMTA200700290Sensor · failedEICAS MSGS RT PACK OFF & PACK TEMP DISPLAYED RT INOP & PACK OFF LGTS ILLUM, LIGHTS EXTINGUISHED WHEN PACK RESET SWITCH IN STANDBY, OPERATION NORMAL IN STANDBY. OCCURED AT FL 350 MACH .79. PERFORMED PACK TEMP CONTROLLER BITE PROC, IAW FIM 21-51-00, FIG 104, FSDR AMTA200700287Connector · disconnectedL2 DOOR LOWER EMERGENCY LIGHT INOPERATIVE. PLUGGED EMERGENCY LIGHT RECEPTICAL INTO SIDE WALL SOCKET OPS CHECK GOOD.SDR AMTA200700285Striker · contaminatedRT FWD ENT DOOR LIGHT ILLUMINATED AND SLIDE DOOR ARM WILL OT ENGAGE. INSPECTED DOOR, CLEAR DEBRIS OFF STRIKER PLATES,, CYCLED AND ARMED DOOR, DOOR OPS CHECK GOOD.SDR AMTA200700279Apu · unknownCAPT BRIEFED APU SHUTDOWN TWICE, APU FAULT MSG. (MX MSG) REPLACED APU IAW W/C M57-49-02 AND 49-11-01-4. OPS AND LEAK CHECK GOOD. (K)SDR AMTA200700276Unknown · unknownHF TRANSMISSION WEAK AT CAPT STATION ALL OTHER STATIONS ARE NORMAL. TRANSMITTED FROM CAPTAINS STATION, STOCKHOLM RADIO REPORT GOOD SIGNAL, OPS CHECK GOOD. (K)SDR AMTA200700269Skin · damagedNR 2 PYLON LOWER SIDE STRUCTURE EXPOSED TO HIGHT HEAT IN AREA OF HP-6 ENGINE PNEUMATIC DUCT AREA. AREA WAS REPAIRED IAW ERA 757-54R-6102 AND SAA EA 757-54-00-09-AO778, DATED 4-20-07, FAA FORM 8100-9/ 337 TIME LIMITED. REPAIR FROM 4/20/07 VALID FOR 24 MONTHS.SDR AMTA200700247Apu · unserviceableAPU AUTO SHUTDOWN. ECU BITE SHOWS (HOT) FAULT. (K) REPLACED APU. OPS AND LEAK CHECK GOOD. (K)SDR AMTA200700240Transceiver · unserviceableHF TRANSMISSION AND RECEPTION (INOPERATIVE) AT ALL CREW STATIONS. REPLACED RT HF TRANSCEIVER IAW MM 23-11-03. OPS CHECK NORMAL. (K)SDR AMTA200700215Filter · dirtyAPU FAILED TO START, APU FAULT MESSAGE - ECU SHOWS LOP SHUTDOWN. FOUND DELTA P ON OIL PRESS FILTER POPPED REPLACED FILTER. RESET DELTA P, RAN APU NO FAULTS NOTED. (K)SDR AMTA200700205Probe · unserviceableCAPT PITOT LIGHT REMAINED ILLUMINATED AFTER ENGINE START. REMOVED AND REPLACED CAPTAINS PITOT PROBE IAW MM 34-11-01. PERFORMED ADJ AND TEST IAW 34-11-01. PERFORMED PITOT LEAK CHECK NO LEAKS NOTED. (K)SDR AMTA200700203Light · disconnectedFLOOR PATH LIGHTING INOPERATIVE FROM ROW 1-4. RECONNECTED LIGHT ASSY. AT ROW 4. OPS CK GOOD. (K)
Back to Boeing 757-23N