Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012110606364Pcu · faultyPER CMC1 TESTS OF RT INBD FLAPERON PCU SHOWS RAM POSITION TRANSDUCER SIGNAL OUT OF RANGE. PER FIM NEEDS ACCESS TO RT INBD FLAPERON PCU CONNECTOR AND REMOVAL OF ACE L2 SUSPECT PCU. REPLACED RIGHT WING FLAPERON INBD. PCU IAW AMM.SDR UALA2012110506319Slide · misinstalledNR 3 LT PAX ENTRY DOOR SLIDE GIRT BAR DIRECTION WAS WRONG. REPLACED WITH NEW SLIDE PER TC NR 228344510.SDR UALA2012110506356Light · improper partPER FCD#3330-01031 FOUND INCORRECT HALOGEN BULBS P/N 9203 INSTALLED AT ALL 4 POSITIONS AND MAINT TEXT: MANDATORY PLACARDS MISSING ABOVE LLAR STA1466 AND STA 1522. ACP FCD 330-01031 PER EG 7521. RELAMPED BULBS AND ADDED PLACARDS.SDR UALA2012110506316Lamp · inoperativeFWD LIGHTS IN AFT CARGO CMPT ABOVE LLAR ARE INOP. FOUND 4 EA LIGHTS OUT DURING COMPLETION OF EG7521 FCD 3330-01031 INOPED PER MEL. REPLACED LAMPS, OPS GOOD.SDR UALA2012110506351Inverter · faultyNO LAND 3 EICAS ON FINAL AT APPROX 1500 AGL. REPLACED STATIC INVERTER PER MM. (ACTION). REPLACED STATIC INVERTER PER MM. AIRCRAFT IS IN CAT 111 STATUS.SDR UALA2012110506350Shutoff Valve · faultyCARGO HEAT VALVE AFT FAILURE OF AFT CARGO HEAT SHUTOFF VALVE OR (SOV) OR TEMP CONTROL VALVE (TCV). STATUS MSG-2112031 INACTV ER MODE MSG-2112021 INACTV DC MODE. COMPLIED WITH MEL PROCEDURE AND MAINT ACTION CARRIED OUT. PSBL VLV (PCN 646-0013), EXPEDITED ON SDR UALA2012110506335Wire Harness · faultySENSOR EXC 1 CB TRIPPING ON P310 PANEL. REPLACED WIRE HARNESS FROM D2181P TO SKEW SENSOR M27325 AND CHECKED OKAY.SDR UALA2012110506332Data Unit · failedCREW REPORTED SATCOM DIRECTORY MISSING NUMBERS, AND IS BLANK. REPLACED SATCOM DATA UNIT PER MM AND OPS NORMAL.SDR UALA2012110506303Drive Assy · faultyWEATHER RADAR SYS DISPLAY IS NOT PRESENT WHEN SELECTED ON EFIS CONTROL PANEL. FAILED AMM TEST FOR ANTENNA FAULT. REPLACED ANTENNA DRIVE UNIT. OPS OK.SDR UALA2012110506334Actuator · faultyTURB CASE COOL HPT R RIGHT ENGINE HIGH PRESSURE TURBINE (HPT) CASE COOLING ACTUATOR IS STUCK OR REVERTED TO ITS FAIL-SAFE POSITION. 2 ENG 777035 REPLACE TCC ACTUATOR. TURBINE CASE CLG AIR VLV ACTR (R ENG) HPT POSITION FEEDBACK IS OUT OF RANGE'. TCC OPERATESSDR UALA2012110506333Battery · dischargedSAT PHONE INOPERATIVE IN CABIN. ON START UP FAULT BALL DISPLAYED ON CTU. TEST EQUIPMENT CHECKED OUT TO RESET CTU AND TROUBLESHOT BUT LAPTOP BATTERY DEAD.SDR UALA2012110206301Structure · wornNR 2 PYLON ACCESS PNL 443CL CUTOUT WORN IN 4 SPOTS BLENDED AND PAINTED ON DOCK WU Q7142E REQUIRES REINSPECTION FOR NEW WEAR EVERY 30 DAYS AND MUST BE PERMANENTLY REPAIRED BY 3-23-2013 PER UA EVA 80711. FOUND ADDITIONAL ABRASION ON TITANIUM TRIPLER. BLENDED OSDR UALA2012110206298Slide · unserviceableTHE NR 4 LEFT PAX ENTRY DOOR SLIDE PACK INFLATION CYLINDER SAFTY PIN FITTING WAS NOT INSTALLED. REPLACED WITH NEW SLIDE.SDR UALA2012103006249Cable · out of rigNO WATER PSI ON A-C CHRONIC PROBLEM. PER MEL PLACARD 38008 ENSURE POV IS CLOSED. COMPLIED WITH REQUIREMENTS IN MEL 3810AR. ADJ- :ADJUSTED RIG OF PRESELECT OVERFLOW VALVE CABLE, OPERATION CHECK NORMAL. WATER PRESSURE NORMAL IN ALL LAVS AND GALLEY.SDR UALA2012103006241Motor · faultyPACK L1 OVERHEAT AT LEFT PACK OUTLET OR LEFT PACK COMPRESSOR OUTLET OR 2) LEFT PACK FLOW CONTROL VALVES (FCV) ARE CLOSED DUE TO: FCVS FAILED CLOSED, FCVS LATCHED CLOSED BY CABIN TEMP CONTROLLER (CTC) BECAUSE OF FAULT, OVERHEAT, OR PACK CONTROL SWITCH COMMANDEDSDR UALA2012102906229Bypass Valve · faultyPACK L, OVERHEAT AT LEFT PACK OUTLET OR LEFT PACK COMPRESSOR OUTLET OR LEFT PACK FLOW CONTROL VALVES (FCV) ARE CLOSED DUE TO: FCVS FAILED CLOSED, FCVS LATCHED CLOSED BY CABIN TEMP CONTROLLER (CTC) BECAUSE OF FAULT, OVERHEAT, OR PACK CONTROL SWITCH COMMANDED OFSDR UALA2012103006247Fastener · looseFLIGHT CREW REST AREA DOOR LOCK UNABLE TO OPEN FROM OUTSIDE. NOT TO BE USED. DOOR LOCK IS INOP CANNOT UNLOCK FROM OUTSIDE. INF- :.PCN 023-1395 OR 023-1394 OUT OF STOCK AT ORD. SECURED LOOSE HARDWARE, OPS CHECK GOOD.SDR UALA2012102906231Control Valve · faultyAPU BLEED AIR STATUS MSG. APU BLEED AIR INOP, APU AIR SWITCH POSITIONED OFF, PLACARDS APPLIED, FWD TO DF MCC INFORMED. -RDF-T :REPLACED APU CONTROLLER PER AMM, NO HELP. INF- :MR49622-37 OFF.MR49622-32 ON. REPLACED SURGE CONTROL VALVE OPS CK'D NORMAL.SDR UALA2012102906218Control Panel · faultyMODE CONTROL PANEL LANE STS MESSAGE. REPLACED MCP PER MM, ACFT RETURNED TO FULL AUTOLAND STATUS.SDR UALA2012102906176Light · inoperativeRIGHT FORWARD INBOARD POSITION LIGHT INOP. NO TIME. REPLACED LAMP IAW MM, OPS CHECKS NORMAL.SDR UALA2012102906232Housing · missingLEFT PACK FAN INLET DIFFUSER HOUSING SUPPORT BRACKET EXITED PACK EXHAUST. REPLACED DIFFUSER HOUSING PER MM, OPS CHECK NORMAL AND LEAK CHECK OK.SDR UALA2012102906221Audio Panel · faultyCAPT AUDIO PANEL, NO GREEN LIGHT ON ADF, WHEN TESTED AND SELECTED. REPLACED AUDIO PANEL PCN 583-0010 ONLINE IPC 11-31-00-0051 REF; MM 23-51-01 PG 401 OP GOOD REF; MM 23- 51-01 PG 401.SDR UALA2012102906227Unknown · leakingLEFT ENGINE HAS A RUNNING LEAK WITH FUEL EXITING THE NR 9 STRUT DRAIN. FOLLOWING LEAK DETECTION TROUBLESHOOTING FOUND LEAK HAD STOPPED FROM NR 9 STRUT DRAIN. DRY MOTOR CARRIED OUT STILL NO LEAK EVIDENT 2 WET MOTOR RUNS CARRIED OUT AGAIN NO LEAK NOTED AFTER FSDR UALA2012102906171Battery Pack · faultyON TAXI OUT F/A REPORT EMERGENCY EXIT PATH LIGHTS ILLUMINATED ON THE SEATS FROM ROW 19 TO DOOR 3R. CRW CYCLED SWITCH ON OVERHEAD AND F/A PANELS, NO HELP. CYCLED C/B'S ON OVERHEAD H9-11 & H16-18 LIGHTS EXTINGUISHED AND NOW DO NOT COME ON WITH FLT DECK SWITCH SDR UALA2012102606152Strut · leakingAIR LEAKAGE WAS FOUND WHEN SERVICING RIGHT MLG SHOCK STRUT REQUIRING THE REPLACEMENT OF THE STRUT. REQUIRES THE REPLACEMENT OF THE STRUT, MR62391. NON ROUTINE GFS 0308892 HAS BEEN CREATED. STRUT ASSEMBLY MR62391-17TEW HAS BEEN REMOVED AND INCLUDES OUTER CYLSDR UALA2012102606147Probe · faultyFUEL QTY INDICATION FUEL TANK QUANTITY ACCURACY IS UNACCEPTABLE. STATUS CREW COMMENTS: RT MAIN TANK FUEL QTY INDICATOR BLANK. MAINT TEXT: HITTING RT TANK PROBES NR 16 M28061 483-0044 MSG 28-2 0121 & NR 18 M28063 483-0046 MSG 28-20125. NEEDS 4 SHIFT SLOT FSDR UALA2012102906220Rfu · malfunctionedDATALINK LOST NO DATA LINKS ESTABLISHED (HF, VHF, SATCOM MODES DATALINKS LOST) ADVISORY CREW COMMENTS: OCCURRED 10+ TIMES IN 4 HOURS OF FLIGHT. REPLACED RADIO FREQUENCY UNIT REF: FIM 23-15 TASK 802 PCN 580-9105. REF; MM 23-15-11 PG 401, OPS CHECK GOOD.SDR UALA2012102606145Module · faultyELMS P110 CHANNEL ONE, BUT NOT BOTH, OF THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P110 PANEL CHANNELS ARE FAULT-DUE TO DF564 ON CHA A. SWAPED 629 CARD BETWEEN CHANNEL A AND B WITH FAULT FOLLOWS, RETURNED CARD TO ORIGINAL, REPLACED A3 CARD WITH ROBBED CARD SDR UALA2012102506134Control Valve · faultyFLAP-SLAT CONTROL 1 HIGH LIFT CONTROL LANE NR 1 HAS A FAULT. STATUS MSG01- LATCHED DESCENT MODE DEPENDENT; SLATS PRIMARY SHUTOFF SOLENOID CIRCUIT IS OPEN. DB- FSEU 1 MSG-2721011 LATCHD DC MODE. FLAP SLAT CONT 1 MESSAGE. REPLACED PRIMARY SHUTOFF SOLENOIDSDR UALA2012102506121Spar · corrodedLEFT WING REAR SPAR WEB CORRODED AROUND FASTENERS IN THE AREA OF IRSS 347 WHERE FUEL BOOST PUMP IS INSTALLED. DAMAGE REPAIRED IAW ECRA 5720-02325.SDR UALA2012102606155Start Valve · faultyENGINE START VALVE L LEFT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION OR STARTER AIR VALVE POSITION INDICATION IS LOST. STATUS MSG01- NOT ACTIVE ENGINE SHUTDOWN MODE DEPENDENT; STARTER AIR VALVE (SAV) (L ENG) IS NOT IN COMMANDED POSITION. DSDR UALA2012102606156Valve · faultyLEFT TRIM AIR PRSOV STATUS MSG WITH TRIM AIR L EICAS MSG. LEFT TRIM AIR PRSOV LOCKED IN CLOSED POSITION PER MEL. ACP'D REPLACEMENT OF VALVE.SDR UALA2012102606154Packing · leakingRIGHT MLG BYPASS SELECTOR VALVE MODULE DRIPPING HYD FLUID. REPLACED PACKING ON HYD LINE FITTING. LEAK CHECK GOOD.SDR UALA2012102506129Control Valve · faultyAPU BLEED STATUS AT THE GATE. REPLACED APU SURGE CONTROL VALVE PER MM, OPS NORMAL.SDR UALA2012102506122Unknown · malfunctionedFUEL PUMP CENTER R RIGHT CENTER (OVERRIDE) FUEL PUMP SWITCHED ON AND PUMP OUTPUT PRESSURE LOW. STATUS CREW COMMENTS: FUEL PUMP CENTER R STATUS MSG. DEFERRED RT CTR FUEL PUMP PER MEL. RESET CB TO PUMP AND ACP TEST REF MM. PUMP OPERATED NORMAL AND ALL MSG'S CSDR UALA2012102506128O-Ring · leakingRIGHT BRAKE SHUTTLE VALVE LEAKING. REPLACED O-RING MOST FORWARD LOWER UNION :RIGHT ANTI-SKID SHUTTLE VALVE. OPERATED SYSTEM, NO LEAK.SDR UALA2012102306080Light · inoperativeEMERGENCY EXIT LIGHTS ARE INOP AT SEAT 3F. REPLACED LIGHT STRIPS AT SEAT 3F, OPS CHECKED GOOD. EMERGENCY LIGHTS TEST GOOD, REF 09-10-05.SDR UALA2012102306079Wire · disconnectedEMERGENCY EXIT LIGHT IS INOP AT SEAT 31G. FOUND WIRE DISCONNECTED. RECONNECTED WIRE, OPS CHECKED GOOD. EMERGENCY LIGHTS OPS CHECK GOOD.SDR UALA2012102206038Header · crackedRIGHT PACK RAM AIR OUTLET HEADER HAS CRACKS 2.5" LONG AND 2" LONG, ALONG THE HEADER WELDS. REMOVED RIGHT PACK HEAT EXCHANGER. REPLACED DUEL HEAT EXCHANGER.SDR UALA2012102306078Processor · faultyFUEL QTY CHANNEL MESSAGE. RESEATED FUEL QUANTITY PROCESSOR, OPS CHECKED.SDR UALA2012102206013Door · damagedTHE 2F LIFE VEST DOOR DAMAGED. REPAIRED DOOR.SDR UALA2012101905986Oven · contaminated19HJK REPORT OF STRONG ELECTRICAL OR PLASTIC BURNING SMELL. PER CREW REPORT, UNABLE TO PINPOINT CAUSE OF ODOR VARIOUS COMPLAINTS WERE BODY ODOR, TOBACCO, PLASTIC SMELL. ALSO NOTICED BY POSITION DOOR 1L. CREW INDICATES NO SMOKE OR FIRE HAZARD. REQUEST SFOMMSDR UALA2012102206042Line · looseCREW REPORTS MOTOR NOISE AND VIBRATION IN DOOR 4 FLOOR AREA. ATTEMPTED TO ISOLATE WITH PACKS, GASPER, CHILLERS, EQUIP COOLING, ETC. NO HELP. RETURNED TO GATE. WATER COMPRESSOR NOISE OBSERVED AT GATE. NOISE GONE AFTER DEACTIVATION. CB G12 P320 PANEL PULLESDR UALA2012101905992Connector · dirtyENGINE REVERSER L LEFT ENGINE THRUST REVERSER CONTROL SYSTEM FAULT AND AIRPLANE ON GROUND. REVERSER IS INOP IN FWD THRUST POSITION. REVERSER DIRECTIONAL CONT VALVE P/N 312W3130-1 IPC78-34-01-002 REF MSG 78-00011 AND FIM 7 8-34 TASKS 805-806. PER FIM 78-34 TSDR UALA2012101705946Panel · delaminatedFOUND AFT FAIRING PANEL P/N 149W5231-1 WITH TWO INCH DELAM DURING WALK AROUND INSPECTION. ROUTED TO SHOP FOR REPAIR. REMOVED AND INSTALLED AFT FAIRING PANEL P/N 149W5231-1.SDR UALA2012101705938Overheat Loop · failedBLEED LOOP 2 BODY FAILURE. REPLACED LOOP, TESTED OK.SDR UALA2012101705925Bolt · brokenON CLIMBOUT NOTICEABLE VIBRATION RIGHT SIDE BETWEEN ROWS 8-10. PER CREW VIBRATION GOES AWAY WHEN THE RIGHT PACK IS SHUT OFF. ACPD 777 MT 05-UA1, FOUND RIGHT RAN AIR DUCT CONNECTION WITH SECONDARY HEAT EXCHANGER BROKEN BOLTS (8M IN A ROW) CAUSING VIBRATION. SDR UALA2012101705929Strip · crackedRIGHT PYLON AFT FAIRING HEAT SHIELD GAP COVER STRIP NR 2 HAS FOUR CRACKS AT OUTBOARD EDGES OF PREVIOUS REPAIRS. FOUND CRACK IN E2 HEATSHIELD GAP STRIP. STRIP HAS BEEN CUTOUT AND MEASUREMENTS TAKEN. REPLACED THE SUBJECT GAP COVER STRIP WITH NEW PER ECRA 5454SDR UALA2012101705928Circuit Card · unsecureELMS P210 PANEL THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P210 PANEL IS FAULTED SUCH THAT IT CANNOT SUPPORT AIRPLANE DISPATCH. AIMS HAS LOTS ARINC 629 COMMUNICATION WITH THE P210 PANEL. OR ONE P210 PANEL CHANNEL IS LOST AND THE OTHER FAULTED AND IS OPERATISDR UALA2012101705926A/C Pack · inoperativeRIGHT AIR CONDITIONING PACK INOPERATIVE. RIGHT RAN AIR INLET DOOR DEACTIVATED IN CLOSED POSITION.
Back to Boeing 777-222