Boeing DHC-8-102

Service difficulty reports · 9,272

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DHC8102'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HNAA2011081100242Seat Track · corrodedRT OTBD SEAT RAIL HAS MINOR CORROSION AT LOCATION X240, X264, X290, X328 AND X342. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1342. PERFORMED HFEC. NO CRACKS FOUND.Jul 28, 2011 · N809EX · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2011081100241Seat Track · corrodedLEFT OTBD SEAT RAIL HAS MINOR CORROSION. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1342 AND RD8-53-3644. PERFORMED HFEC INSP. NO CRACKS FOUND.Jul 28, 2011 · N809EX · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2011081100240Seat Track · corrodedLT INBD SEAT RAIL HAS MINOR CORROSION AT LOCATIONS X345, X372. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1339. COMPLIED WITH HFEC INSP, NO DEFECTS NOTED.Jul 28, 2011 · N809EX · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2011081100239Threshold · corrodedPAX DOOR THRESHOLD PANEL AREA CORRODED. REMOVED PAX DOOR THRESHOLD ASSEMBLY. INSTALLED NEW THRESHOLD ASSEMBLY IAW DWG 85321241.Jul 28, 2011 · N809EX · Dhav DHC8102 · Fuselage Miscellaneous StructureSDR HNAA2011081100238Seat Track · corrodedLIGHT INBD SEAT RAIL HAS FRETTING CORROSION FROM FLOOR PANELS AT X224 TO X312. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-1339 AFT OF STA X262. PERFORMED HFEC. NO CRACKS FOUND.Jul 28, 2011 · N809EX · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2011081100237Seat Track · corrodedLT SIDE INBD SEAT RAIL SEVERLY CORRODED AT X200 TO X205. CUTOUT CORRODED SET RAIL SECTION IAW RD8-53-3074, SPLICED LT INBD SEAT RAIL IAW RD8-53-3074 AND DWG NR 8520019.Jul 28, 2011 · N809EX · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2011081100236Seat Track · corrodedRT SIDE INBD SEAT RAIL HAS MINOR CORROSION AROUND LAV MOUNTING HOLES. BLENDED CORROSION AWAY WITHIN LIMITS IAW RD8-53-4698. PERFORMED HFEC INSP, NO CRACKS FOUND.Jul 28, 2011 · N809EX · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2011072600223Module · inoperativeMIDCABIN FLOOR EMERGENCY LIGHT AT ROW 2DF WILL NOT ILLUMINATE. INSTALLED NEW LIGHT MODULE AS REQUIRED.Jul 26, 2011 · N914HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011072600222Splice · failedRIGHT FORWARD EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE. FOUND DIODED MATRIX SPLICE 3352-CR6 BROKEN. R & R DIODED. EXIT LIGHT OPERATED NORMALLY ON GROUND.Jul 25, 2011 · N914HA · Dhav DHC8102 · Light System WiringSDR CA110725010Packing · deterioratedDURING CLIMB, THE CREW RECEIVED A NR 1 ENG HYD PUMP CAUTION LIGHT WITH THE ASSOCIATED PRESSURE AND QUANTITY INDICATORS READING ZERO. AS A RESULT OF THE NR 1 HYD SYS LOSS, THE FOLLOWING SYS WERE INOPERATIVE: FLAPS, INBD ROLL SPOILERS, NORMAL BRAKES, ANT-SKID AJul 24, 2011 · Dhav DHC8102 · Hydraulic System, MainSDR HNAA2011072600221Warning Light · false activationIN FLIGHT, LANDING GEAR INOPERATIVE CAUTION LIGHT ILLUMINATED TWICE AND EXTINGUISHED. PERFORMED ALTERNATE EXTENSION. NO INCIDENT ON LANDING. ENTIRE FLIGHT HAS GOOD HYD PRESSURE AND QTY. COULD NOT DUPLICATE IN HANGER, R & R PSEU AND RELAYS 3261-K5, K6 AND K7 AJul 24, 2011 · N942HA · Dhav DHC8102 · Landing Gear Position and WarningSDR HNAA2011072600220Oil System · lowREJECTED TAKEOFF AT 70 KNOTS. MASTER WARNING LIGHT ILLUMINATED AND NR 2 ENGINE OIL PRESSURE WARNING LIGHT. INSPECTED NR 2 ENGINE FOR EVIDENCE OF OIL LEAKS. NONE FOUND. INSPECTED CONNECTOR PLUG, NR 2 OIL PRESSURE SWITCH. NO DEFECTS NOTED. FOUND NR 2 OIL QJul 24, 2011 · N941HA · Dhav DHC8102 · Turbine Engine Oil SystemSDR HNAA2011072600219Unknown · smokeAFTER TAKEOFF, A SWEET ODOR FOLLOWED BY WHITE SMOKE IN COCKPIT. CLEARED WHEN SELECTED BLEEDS OFF. INSPECTED AIR SWITCHING VALVES ON NR 1 AND NR 2 ENGINES. NO DEFECTS NOTED. INSPECTED OVERHEAD AND SIDEWALL LIGHTS, NO DEFECTS NOTED. GROUND RAN ACFT AT POWER Jul 23, 2011 · N805EX · Dhav DHC8102 · Air Distribution SystemSDR CA110718003Line · crackedDEFECT-1000248, COMPLETE LOSS OF NR 2 HYD FLUID AFTER PULLING AWAY FROM THE GATE. LP 618049. (RESOLVED ON W/O: 295549, TASKCARD: NR-00001) FORE AND TRAILING RUDDER REMOVED FOR ACCESS TO HYD LINES. IAW 27-20-11 AMM, LINE IPC REF-27-21-00 15 ITEM 040 . TUBE ASSJul 15, 2011 · Dhav DHC8102 · Hydraulic System, MainSDR HNAA2011072100216Bulb · burned out2 RED FORWARD EMERGENCY LIGHTS ON FLOOR ARE OUT. R & R LIGHT BULBS. OPS CHECKED GOOD.Jul 14, 2011 · N343EN · Dhav DHC8102 · Emergency LightingSDR HNAA2011072100215Bulb · failedFLOOR LEVER EMERGENCY LIGHT AT ROW 1. R & R BULB AT ROW 1.Jul 14, 2011 · N804EX · Dhav DHC8102 · Emergency LightingSDR CA110712003Jackscrew · failedON APPROACH WHEN FLAPS 35 SELECTED, THEY STOPPED AT 15 DEGREES. ON WALKAROUND FOLLOWING LANDING, THE CREW NOTICED THE LT INBD FLAP CAME DOWN ASYMMETRIC AND THE LOWER CORNER DUG INTO THE COMPOSITE PANEL ON THE FUSELAGE AND THE T/E OF THE FLAP WAS DAMAGED. SUJul 11, 2011 · Dhav DHC8102 · Trailing Edge Flap Control SystemSDR HNAA2011071400213Controller · malfunctionedACFT DID NOT PRESSURIZE DURING CLIMBOUT AND NR 1 TRANSPONDER, F/O ALT, F/O IVSI FAILED. MX R & R NR 2 BLEED OVERTEMP SWITCH AND CABIN PRESSURE CONTROLLER AND NR 2 FGC, ALL SYS OPS CHECKED GOOD DURING GROUND RUN UPS AND LEAK CHECKED GOOD WITH TEST SET PROCEDURJul 11, 2011 · N934HA · Dhav DHC8102 · Cabin Pressure ControllerSDR HNAA2011071400212Oil System · leakingREJECTED TAKEOFF DUE TO NR 2 OIL PRESSURE WARNING LIGHT ILLUMINATED. CLEANED AND INSPECTED ENGINE FOR LEAKS, FOUND NR 2 ENGINE, 2 QUARTS LOW ON OIL. ADDED OIL AS REQUIRED. GROUND RAN, OPS CHECKED GOOD.Jul 11, 2011 · N942HA · Dhav DHC8102 · Turbine Engine Oil SystemSDR HNAA2011071400211Eec · failedNR 2 ENGINE TQ WENT TO 117 PERCENT, THEN FELL BACK TO 40 PERCENT, THEN WENT TO 80 PERCENT AND STABILIZED FOR 30 SECONDS, THEN WENT TO 121 PERCENT WITH NO INPUTS. THEN SHUTDOWN ENGINE. HEARD ENGINE PITCH CHANGE AND FELT YAW. GROUND RAN ACFT FOR MORE THAN 20 Jul 11, 2011 · N815EX · Dhav DHC8102 · Engine ControlsSDR HNAA2011071400210Panel · corrodedPANEL 622AT HAS PITTING IN MARKED COUNTERSINKS. REMOVED PITTING IAW RD8-57-1686.Jul 8, 2011 · N914HA · Dhav DHC8102 · Wing, Plate/SkinSDR HNAA20110400209Panel · corrodedPANEL 523AT HAS PITTING IN NUMEROUS COUNTERSINKS. REMOVED PITTING IAW RD8-57-1686.Jul 8, 2011 · N914HA · Dhav DHC8102 · Wing, Plate/SkinSDR HNAA2011071400208Panel · groovedPANEL 522AT HAS DEEP GROOVES AND PITTING IN COUNTERSINKS. REMOVED GROOVES AND PITTING IAW RD8-57-1686.Jul 8, 2011 · N914HA · Dhav DHC8102 · Wing, Plate/SkinSDR HNAA2011071400207Seat Track · corrodedRT INBD AFT SEAT RAIL IS CORRODED ALONG OTBD FLANGE. REMOVED OLD SEAT RAIL, INSTALLED NEW RT INBD AFT SEAT RAIL IAW DWG 85330129 AND RD8-53-4472.Jul 5, 2011 · N914HA · Dhav DHC8102 · Fuselage, Seat/Cargo Attach FittingsSDR HNAA2011071400205B-Nut · leakingNR 1 HYD SYS LOST CONTENTS AFTER TAKEOFF. RETURNED TO FIELD. NR1 ENGINE MANUALLY SHUTDOWN NO MORE THAN 8 MINUTES AFTER LOSS. FOUND NR 1 EDP PRESSURE LINE "B" NUT LOOSE UNDER PANEL 412DT. RETORQUE "B" NUT, SERVICED NR 1 HYD, SYS CHECKED GOOD. REINSTALLED PJul 5, 2011 · N933HA · Dhav DHC8102 · Hydraulic System, MainSDR HNAA2011071400204Pressure Switch · malfunctionedUPON ADVANCING POWER LEVERS FOR TAKEOFF, THE ROLL SPOILERS OTBD HYD CAUTION LIGHT ILLUMINATED AND THE ROLL OTBD ADVISORY LIGHT STAYED ON. R & R ROLL SPOILER PSI SWITCH, GROUND RAN NR 2 ENGINE, OPS AND LEAKED CHECKED GOOD.Jun 30, 2011 · N908HA · Dhav DHC8102 · Drag Control SystemSDR CA110630002Tube · leakingDURING CLIMB, CREW OBSERVED THE NR 1 HYD SYS DEPLETING. CREW ELECTED TO CONTINUE ON TO DESTINATION. NEAR DESTINATION, CREW DECLARED AN EMERGENCY AND LANDED WITHOUT FURTHER INCIDENT. LOSS OF THE NR 1 HYD SYS RESULTED IN THE LOSS OF WING FLAPS, INBD ROLL SPOJun 27, 2011 · Dhav DHC8102 · Hydraulic System, MainSDR HNAA2011062900203Bracket · failedRIGHT DOOR AMBER LIGHT ILLUMINATED ON GEAR RETRACTION. CYCLED GEAR,ON EXTENSION, GEAR WENT OUT WHEN RETRACTED. LIGHT CAME BACK ON. INSTALLED NEW HOOK AND PROX SENSOR BRACKET ASSY IAW MM 32-10-21. PERFORMED SEVERAL GEAR SWINGS, ALSO PERFORMED EMERGENCY ALTERJun 27, 2011 · N940HA · Dhav DHC8102 · Landing Gear DoorsSDR HNAA2011062900202Bulb · inoperativeAFT EMERGENCY FLOOR PATH LIGHT IS TOO FAR BACK AND VERY DIM. R & R BULB. REPOSITIONED PATH LIGHT.Jun 24, 2011 · N934HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011062900200Light · misinstalledEMERGENCY FLOOR PATH LIGHTS AT ROWS 5 AND 6. THE ARROWS ARE FACING THE WRONG DIRECTION. REPOSITIONED EMERGENCY FLOOR PATH LIGHTSAT ROWS 5 AND 6 TO FACE PROPER DIRECTION.Jun 24, 2011 · N934HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011062900199Bulb · failed(1) OVERHEAD EMERGENCY LIGHT AT ROW 6 IS INOP. R & R BULB. OPS CHECKED GOOD.Jun 23, 2011 · N906HA · Dhav DHC8102 · Emergency LightingSDR HNAA11062900200ABattery · failedLEFT AFT EMERGENCY EGRESS LIGHT IS INOP. FOUND AFT EMERGENCY CEILING LIGHT INOP. R & R EMERGENCY LIGHT BATTERY AT PS3 LOCATION. OPS CHECKED GOOD.Jun 23, 2011 · N975HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011062100180Drag Strut · inoperativeREJECTED TAKEOFF DUE TO NOSE GEAR UNSAFE LIGHT, GEAR SELECT HANDLE LIGHTS AND NOSE STEERING CAUTION LIGHT ILLUMINATED AT 75 KNOTS ON TAKEOFF ROLL. LIGHTS EXTINGUISHED AT TIME OF REJECTION. R & R DRAG STRUT AND DOWN LOCK PROX SWITCHES. IAW -8 MM 32-20-16. OPSJun 19, 2011 · N906HA · Dhav DHC8102 · Landing Gear Retraction/Extension SystemSDR HNAA2011062100179Battery · inoperativeAUXILIARY BATTERY HOT CAUTION LIGHT ILLUMINATED AFTER TAKEOFF. R & R MAIN AND AUX BATTERIES IAW 24-32-00. OPS CHECKED GOOD.Jun 19, 2011 · N839EX · Dhav DHC8102 · Battery/Charger SystemSDR HNAA2011062100178Panel · missingNR 1 HORSE COLLAR PANEL MISSING. INSPECTED SURFACE AREA OF ACFT FOR POTENTIAL DAMAGE RESULTING FROM NR 1 HORSE COLLAR LOSS. NONE FOUND.Jun 18, 2011 · N812EX · Dhav DHC8102 · Nacelle/Pylon, Plate/SkinSDR HNAA2011062100177Lamp · inoperativeLT FORWARD EMERGENCY EGRESS LIGHT IS INOP. INSPECT BULB AND FOUND TO BE A WRONG BULB. RELAMP LT FORWARD EMERGENCY EGRESS LIGHT. OPS CHECKED GOOD.Jun 17, 2011 · N3351 · Dhav DHC8102 · Emergency LightingSDR HNAA2011062100176Battery · failedLT EMERGENCY EXIT SIGN AND LT FWD EMERGENCY EGRESS LIGHT INOP. R & R EMERGENCY LIGHT BATTERY AT PS1 LOCATION. OPS CHECKED GOOD.Jun 16, 2011 · N942HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011062100175Seal · failedF/A REPORTS DAYLIGHT VISIBLE AROUND PAX DOOR IN FLIGHT. LOAD SQUEAL NOISE HEARD. REPLACED DOOR STOP TENSION BOLT AND BUSHING AT THE FORWARD NR 5 POSITION AND ADJUSTED II -8, MM 52-10-00. FOUND DOOR SEAL PULLING APART ALONG TOP OF DOOR WAY. R & R DOOR SEAL Jun 15, 2011 · N907HA · Dhav DHC8102 · Passenger/Crew DoorsSDR CA110617006Socket · burnedF/A ADVISES THAT THERE IS A BURNING ELECTRICAL ODOR FROM AREA OF 2AC. 547790. DEFECT CONFIRMED SIDEWALL LIGHT SOCKET AT 4AC MELTED. LIGHT DEACTIVATED AND MEL APPLIED. SIDEWALL LIGHT SOCKET ASSY AT 4AC REPLACED, OPS CHECKED SERVICEABLE ACCORDING TO SHOP.Jun 12, 2011 · Dhav DHC8102 · Passenger Compartment LightingSDR CA110615005Fitting · crackedTHE TAKEOFF WAS REJECTED (BELOW 70 KTS) WHEN THE LT ENGINE OIL PRESSURE WENT TO ZERO. THE RT OIL INLET TUBE ADAPTER FITTING TO THE LT OIL COOLER WAS FOUND BROKEN AND THE TUBE DISCONNECTED. THIS RESULTED IN THE LOSS OF A SUBSTANTIAL AMOUNT OF OIL IN A SHORT PEJun 12, 2011 · Dhav DHC8102 · Engine Oil CoolerSDR HNAA2011061300174Bulb · burned outFLOOR EMERGENCY LIGHT INOPERATIVE AT ROW 7. R & R BULB IN THE EMERGENCY FLOOR LIGHT AT ROW 7. OPS CHECKED GOOD.Jun 12, 2011 · N942HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011061300173Bulb · burned outOVERHEAD EMERGENCY LIGHT INOP AT ROW 5. R & R BULB. OPS CHECKED GOOD.Jun 12, 2011 · N942HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011061300172Lens · wrong partFIRST FLOOR EMERGENCY LIGHT LENS IS WRONG COLOR. INSTALLED CORRECT COLORED LENS AS REQUIRED.Jun 12, 2011 · N942HA · Dhav DHC8102 · Emergency LightingSDR HNAA2011061300171Battery · failedLEFT AFT EMERGENCY EGRESS LIGHT INOP. R & R BULB, PN 81. NO FIX. R & R EMERGENCY LIGHT BATTERY AT POSITION PS3. OPS CHECKED GOOD.Jun 9, 2011 · N943HA · Dhav DHC8102 · Emergency LightingSDR CA110610010Actuator · crackedHYD LEAK WAS NOTED FROM THE LT SIDE WING NACELLE AREA DURING ENGINE START UP. UPON CLOSER INSP AFTER ENGINE SHUTDOWN, IT WAS CONFIRMED TO BE COMING OFF THE LT OTBD SPOILER ACTUATOR. THE HSG ON THE ACTUATOR WAS FOUND CRACKED. ACTUATOR REPLACED, ACFT GROUND RJun 7, 2011 · Dhav DHC8102 · Drag Control ActuatorSDR HNAA2011061300168Control Panel · failedMULTIPLE CAUTION LIGHTS CAME ON DURING TAKEOFF ROLL AND TAXI. R & R MASTER CAUTION PANEL IAW -8, MM 33-12-01. GROUND RAN ACFT. NO DEFECTS NOTED AT THIS TIME. OK FOR SERVICE.Jun 7, 2011 · N941HA · Dhav DHC8102 · Indicating/Recording SystemSDR HNAA2011061300167Electronic Unit · failedCAN NOT TRANSMITT EITHER RADIO FROM NR1 ACP. R & R REU. OPS CHECKED GOOD. OK FOR SERVICE IAW -8 MM 23-50-00.Jun 7, 2011 · N908HA · Dhav DHC8102 · Communications SystemSDR HNAA2011061300166Light · inoperativeONE RED EMERGENCY FLOOR LIGHT INOP. R & R RED EMERGENCY FLOOR LIGHT.Jun 6, 2011 · N810EX · Dhav DHC8102 · Emergency LightingSDR HNAA2011061300165Bulb · burned outROW 9 EMERGENCY FLOOR ESCAPE PATH LIGHT INOP. R & R BULB, OPS CHECKED GOOD.Jun 4, 2011 · N943HA · Dhav DHC8102 · Emergency LightingSDR CA110607006Bracket · crackedDURING REPLACEMENT OF THE LT INBD ROLL SPOILER ACTUATOR, A CRACK WAS NOTICED ON THE LT OTBD ROLL SPOILER ACTUATOR MOUNT BRACKET. THE LT OTBD ROLL SPOILER MOUNT BRACKET WAS REPLACED.Jun 3, 2011 · Dhav DHC8102 · Wing, Attach Fittings
Back to Boeing DHC-8-102