Boeing MD-90-30
Service difficulty reports · 6,066
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1141569227Seat Track · corrodedPERFORMED TASK CARD 65034006 CORROSION ON SEAT TRACK BETWEEN STA 1260 & 1290 OF AFT CABIN SRM 53-40-01 VOL 1 FIG 6.SDR DALA1141559227Seat Track · corrodedPERFORMED TASK CARD 65033987 CORROSION ON SEAT TRACK BETWEEN STA 1184 & 1288 OF AFT CABIN SRM 53-40-01 VOL 1 FIG 6.SDR DALA1141549227Seat Track · corrodedPERFORMED TASK CARD 65033952 CORROSION ON R2 TRACK AT STA 240 OF CABIN SRM 53-40-01 VOL 1 FIG 6.SDR DALA1141509227Seat Track · corrodedPERFORMED TASK CARD 65033951 CORROSION ON R1 TRACK AT STA 240 OF CABIN SRM 53-40-01 VOL 1 FIG 6.SDR DLM90060842Deflector · brokenON APPROACH ATTEMPTED TO LOWER GEAR. UNSAFE LIGHT FOR NOSE GEAR REMAINED ON. LANDED AT DEN WITH NOSE GEAR NOT EXTENDED EXTENSIVE DAMAGE TO FUSELAGE AROUND NLG OPENING AND E/E DOOR. INVESTIGATION IN PROGRESS BUT FOUND LEFT WHEEL SPRAY DEFLECTOR DAMAGED. ACCSDR DLM90060666Starter · overheatedAPU AUTO SHUTDOWN ON TAXI OUT, ACS FAULT ON OAP, AND STRONG ELECTRICAL SMELL IN CABIN. INSTALLED NEW STARTER PER M/M. INSPECTED APU COMP. NO PROBLEMS NOTED. REPLACED APU START RELAY. APU OPS CHECKS NORMAL. STARTER LEAK CHECK GOOD. NO FAULTS.SDR DLM90060626Power Supply · dischargedCEILING EMERGENCY EXIT LIGHTS WILL NOT TURN ON WHEN SELECTED STARTING AT ROW 38 TO AFT LAVS. FOUND POWER SUPPLY B5-237 INOP STA 1393 R&R B5-237 OPS NORMAL.SDR DALA1134569221Skin · dentedDENT ON LOWER SKIN OF RT INBOARD FLAP SRM 57-53-01 VOL I FIG 1.SDR DLM90060487Ballast · burnedSMOKE COMING OUT OF PSU UNIT 26 CDE FOR 2 MINUTES, SMOKE THEN DISSIPATED. FOUND ONE SIDEWALL FLUORESCENT LAMP INOP AT ROW 26R. REMOVED PANEL AND INSPECTED SAME. RISIDUAL SMELL PRESENT WITH NO OTHER PROBLEMS FOUND. SUSPECT LIGHT BALLAST. FWD TO MCO AND PLASDR DLM90060485Brake · malfunctionedNORMAL LANDING AT DEN WITH NORM SPEED LT REVERSER ON MCO, MED AUTOBRAKES. TURNING INTO GATE GOT HOT BRAKES. TEMP OFF SCALE. FUSE PLUGS BLEW AND TIRES DEFLATED. REPORTED BRAKE FIRE. REPLACED NR 1 AND 2 BRAKES. REPLACED NR 1 AND 2 MAIN WHEELS ASSY PER MM. SDR DLM90060417Engine · malfunctionedON APPROACH INTO PHX, LOST OIL PRESSURE ZERO INDICATION WITH LOW OIL PRESSURE MESSAGE ON EOAP WITH BOTH OIL PRESSURE CAUTION AND WARNING LTS ILLUMINATED. ENGINE SHUTDOWN ACCOMPLISHED PER QRH. OIL TEMP AND ALL OTHER PARAMETERS WERE NORMAL PRIOR TO SHUTDOWN. SDR DLM90060424Starter · burnedFOUND APU STARTER AND HARNESS BURNED DURING START. REPLACED APU STARTER AND HARNESS ASSEMBLY AND R2-63 START RELAY PER M/M. NOW CHECKS GOOD.SDR DLM90060413Starter · overheatedAPU WOULD NOT START 2 ATTEMPTS MADE. CONTROL C/B PULLED RAMP REPORTED SMOKE FROM APU COMPARTMENT. SMOKE STOPPED IN FIVE MINUTES. TORQUED RELAY TERMINALS. REPLACED APU STARTER AND CLAMP. INSPECTED TAIL PIPE AND STARTER HARNESS FOUND OK. BITE ECU, FAULTS ASDR DLM90060287Converter · inoperativeLEFT ENGINE GEN FAILED AFTER TAKEOFF. REPLACED NR 1 ENGINE GEN CONVERTOR UNIT. GEN CHECKED OK.SDR DLM90060284Lens · missingEMERGENCY LIGHT LENS MISSING AT FIRST CLASS COACH DIVIDER. INSTALLED LENS, LIGHT OPS CHECKS OK.SDR DLM90060263Engine · malfunctionedLEFT ENGINE BEGAN TO SHUDDER FOLLOWED BY A COMPRESSOR STALL AND PARAMETER ROLLBACK AND EGT INCREASE. C/W BORESCOPE INSPECTION OF THE HPC AS PER AMM. FOUND NUMBER STAGES DAMAGED AND OUT OF LIMITS. REPLACED ENGINE PER TRANS 2T102.SDR DLM90060238Generator · lack of lubeAT CRUISE POWER DISRUPTED W/L AC PWR FAULT AND L GEN OFF MSG GEN WOULD NOT RESET. ACCOMPLISHED QRH PROCEDURE. LEFT BUS RECEIVED PWR FROM APU GEN BUT APU FAULT MSG ILLUMINATED. L ELEC SYS FAIL AND L GEN OIL PRESS MSGS APPEAR WHEN STATUS BUTTON PUSHED. (ATL SDR DLM90060202Slide · no testL-1 DOOR SLIDE FAILED FUNCTIONAL CHECK OUT PER OPN 6800. SLIDE FAILED TO DEPLOY COMPLETELY. SLIDE P/N 100504-205, S/N D9F065, PACK DATE 05/24/05. REPLACED SLIDE AND FAILED THE SECOND TIME PER OPN 6800. SLIDE EMERGENCY LIGHTING WAS INOP ON THE FORWARD SIDE.SDR DLM90060194Generator · failedRIGHT GEN INOP ON MCO, APU LOW ON OIL, MSG IN FLIGHT. RETURN TO GATE. REPLACED RIGHT GEN, CHECKS GOOD. SERVICED APU, CHECKS GOOD. NO LEAKS.SDR DLM90060173Slide · malfunctionedWHILE PERFORMING ROUTINE OPERATION 6800 (MD90 DOOR SLIDE DEPLOYMENT SYSTEM OPERATIONAL CHECK) ON SHIP 9216 L1 DOOR, THE SLIDE LIGHTS DID NOT COME ON. DOOR SLIDE S/N D9F057, P/N 100504-205. REPLACED SLIDE.SDR DLM90060169Engine · hot startON DESCENT, NR 1 ENGINE EGT PEGGED AT TOP OF RED RANGE 881 DEG WITH OIL PRESS AT 260 PSI AND OIL TEMP 96 DEG. NO OTHER UNUSUAL INDICATIONS. RETARDED TO IDLE WITH NO IMPROVEMENT. SHUT ENGINE DOWN IAW QRH. REPLACED ENGINE.SDR DLM90060093Pressure Switch · inoperativeAIRCRAFT RETURNED TO CVG BECAUSE THE AIRCRAFT FAILED TO PRESSURIZE. FLOW LIGHT AND NO MODE LIGHT ILLUMINATED WITH CR POWER SELECTED. OUTFLOW VALVE DROVE FULL CLOSED AND NO AIR FLOW FROM PACKS. REPLACED NUMBER 1 ENGINE AUTO PRESS DIFF SWITCH. CHECKS OK.SDR DLM90060079Skin · crackedFUSELAGE CROWN SKIN PANELS ARE CRACKED AT THREE LOCATIONS NEAR STA 1475, L-1R. REMOVED DAMAGED SKIN AND INSTALLED A DOUBLER.SDR DLM90060094Skin · corrodedCORROSION ON LOWER FUSELAGE SKIN AT STA 864 BETWEEN L-30 AND L-29R. REMOVED CORROSION AND INSTALLED REPAIR DOULBER.SDR DLM90060096Skin · corrodedLOWER SURFACE OF FUSELAGE SKIN STA 826-864, L-28R-29R WAS FOUND WITH CORROSION. REMOVED CORROSION AND INSTALLED REPAIR DOUBLER PER ER/A 386336-14.SDR DLM90060051Wire · brokenFLOOR EMERGENCY LIGHTS INOP ROW 10 -13 CDE. FOUND BROKEN WIRE. RESPLICED, CHECKS NORMAL NOW.SDR DLM90060047Warning Light · illuminatedON TAKEOFF AT KOAK, EOAP DISPLAYED RT EECEDP BUSS FAIL. TROUBLESHOT PER FIM, MESSAGE CLEARED.SDR DLM90060034Duct · failedON CLIMBOUT AT 6000 FT FLOW LIGHT ILLUMINATED. AT ALTITUDE OF 10000 (CABIN ALT 9000) FLOW LIGHT WENT OUT. WHEN CLIMB INITIATED FLOW LIGHT CAME ON AGAIN AND CABIN ALT WARNING SOUNDED. FLT ATTENDANT REPORTED LOUD NOISE FROM AROUND 2 L DOOR AREA. REPLACED BLOSDR DLM90050808Starter · unserviceableON APU START, APU FAULT DISPLAYED AND SMOKE COMING FROM TAIL COMPT. ON FURTHER INSP, SAW VISIBLE FLAME COMING FROM APU STARTER. FLAME WENT OUT AND NO EXTINGUISHING AGENT WAS NEEDED. REPLACED STARTER, CLUTCH, AND START RELAY.SDR DLM90050688Slide · no testPERFORMED OPN 6900 AND SLIDE DID NOT DEPLOY. ADJUSTED AFT STRAPS PER FIG 18 AND SLIDE DEPLOYED AS REQUIRED.SDR DLM90050668Guide Arm · out of alignmentFLOW LIGHT ILLUMINATED ON CLIMBOUT. GOOD FLOW ON BOTH PACKS FLT ATTENDANT REPORTED LOUD NOISE AT 2 LEFT DOOR. MAX CABIN ALT 9000. CABIN PRESSURE 2 PSID. FOUND DOOR GUIDE ARM ON WRONG SIDE OF ROLLER MECHANISM AND GUIDE ROLLERS NOT SEATED IN GUIDES. LUBRICSDR DLM90050622Strut · dischargedFELT JOLT/SHUTTER JUST AFTER TAKEOFF RAISING GEAR HANDLE. THOUGHT PROBLEM MIGHT BE WITH NOSE GEAR, HOWEVER JOLT/SHUT FELT FROM COCKPIT TO AFT FLT ATTENDANT STA. ALL COCKPIT IND NORMAL THROUGHOUT FLT. RETURNED TO SLC. SERVICED NOSE GEAR PER MM 31-21-01. CYSDR DLM90050592Hose · leakingON APPROACH LOST ALL RIGHT SIDE HYDRAULIC QUANTITY. REPLACED LEAKING RT ENGINE PUMP PRESSURE LINE.SDR UIA0508Sensor · failedLANDING GEAR WARNING HORN SOUNDED 2 TIMES DURING ROLL OUT. FOLLOWED BY RT MAIN GEAR RED LIGHT FLASH. AIRCRAFT STOPPED AT TAXIWAY. INSPECTION FOUND R MAIN LANDING GEAR DOWNLOCK PROXIMITY SENSOR NOT GOOD. IAW AMM REPLACED THE SENSOR AND ADJ. CLEARANCE TO 0.0SDR DLM90050526Crank Assy · crackedLEFT PYLON FLAP ACTUATOR CONTROL ROD BRACKET IPC27-51-00-35 ITEM 145 CRACKED AT SPLINE BOSS CLAMPING AREA RESULTING IN LOSS OF MOVEMENT OF LEFT PYLON FLAP PANEL. MFG P/N 5966309-1. REPLACED SAME.SDR DLM90050472Tru · failedAPPROX 10 MINS AFTER T/O LEFT GENERATOR TRIPPED OFF LINE AND WOULD NOT RESET. APU WAS STARTED IAW PROCEDURE. LOSS OF CAPTS FLT DIRECTOR, NR 1 VOR, AND ALL ENGINE INSTRUMENTS WERE CONTINUALLY FLICKERING AND DISPLAYING ERRONEOUS DATA. GROUND PROXIMITY C/B WASSDR DLM90050401Cable · frayedSEAT CABLE SPARKING AT SEAT LEG. FOUND CABLE FRAYED. REPLACED SAME.SDR DLM90050342Control Unit · inoperativeMOMENTARY POWER INTERRUPTION INFLT. EMERGENCY LTS FLICKER. INSTS FLICKER. HAPPENED IMMEDIATELY AFTER T/O AND TWO MORE TIMES IN CLIMBOUT. APU STARTED AS PRECAUTION. NO EPCU FAULTS, VSCF FANS TEST OK. REPLACED EPCU PER MM, NEEDS FUNCTIONAL TEST TASK 24-21-03-SDR DLM90050333Bottle · unserviceableCREW OXYGEN PRESSURE DROPPED TO ZERO ON CLIMB. REPLACED CREW OXYGEN BOTTLE AND REGULATOR. NO LEAKS.SDR UIA0505Engine · failedRT ENGINE IN FLIGHT SHUTDOWN (IFSD) CAUSED BY SURGE MESSAGE SHOW ON EOAP, THEN FOLLOW EGT RAPID INCREASE. AFTER LANDING CHECK FOUND SEVERAL STAGE 4 BLADES MATERIAL MISSING AND BEND WITH DENTS. STAGE 5-12 BLADES BURN. THIS CASE COULD BE IOD IAW AMM 71-00-10.SDR UIA0504Strut · underservicedNOSE GEAR RED LIGHT ON AFTER TAKEOFF, A/C AIR TURN BACK. GROUND CHECK FOUND NOSE LANDING GEAR SHOCK STRUT DIMENSION ABOUT 1 INCH , IAW AMM 32-21-01 RE-SERVICE NLG STOCK STRUT TO 4 INCH, CHECK AIR NO LEAKING ,CONDITION BACK NORMAL.SDR DLM90050250Brake · unserviceableDURING TAXIOUT FOR TAKEOFF, LEFT BRAKE GRABBED DURING TURN, CAUSING FLIGHT ATTENDANT TO STUMBLE. STOPPED A/C TO CHECK ON F/A CONDITION. UPON CONTINUING TAXI WITH TIGHT LEFT TURN ONTO PARALLEL TAXIWAY, NOSE GEAR SLID AT EDGE OF CONCRETE ONTO ASPHALT APRON. ASDR DLM90050182Oven · malfunctionedFORWARD GALLEY OVEN SMOKED WHEN TURNED ON. SMOKE DISSIPATED WHEN OVEN WAS SELECTED OFF. REPLACED OVEN.SDR DLM90050164Skin · crackedCRACK OF 2 INCH ON SKIN OF AFT FUSELAGE STA Y=953.604 AND INTERSECTION OF LONGERON 23 LT. REPAIRED SAME.SDR DLM90050157Brake · leakingHYDRAULIC QTY LOW LT HAND. FOUND NR 1 BRAKE ASSEMBLY LEAKING FROM THE SIX O`CLOCK POSITION. REMOVE AND REPLACE NR 1 BRAKE ASSY AND SERVICED LT HYDRAULIC SYSTEM AS PER AMM. NO LEAKS FOUND.SDR DLM90050153Coffeemaker · dirtyCLEANED BURNED COFFEE FROM HOT PLATE IN AFT GALLEY DUE TO BURNING SMELL.SDR DLM90050106Starter · failedAFTER APU START ELECTRICAL SMELL IN CABIN. APU STARTER FAILED. REPLACED APU STARTER.SDR DLM90050094Starter · inoperativeAPU WOULD NOT START. REPLACED APU STARTER AND START CONTROL RELAY. REPLACED WIRE AT B1-1058 PIN 5A.SDR UIA0502Switch · jammedIN FLT RADIO COMMUNICATION FAILURE (VHF NR 1 AND NR 2). AC AIR TURN BACK. MAINTENANCE CHECK FOUND RT CONTROL COLUMN PTT SW FUNCTION NO T GOOD. CAUSED RADIO SYSTEM FAILURE. IAW AMM23-51-07 REPLACED RT CONTROL COLUMN PTT SW AND OPERATIOAL TEST SYSTEM BACK, SDR DLM90050052Switch · sparksWING LANDING LIGHT SWITCH SHOT OUT SPARKS AND POPPED VERY LOUD AS LIGHTS WERE TURNED ON. OPS CHECKED LIGHTS AND INSPECTED BEHIND SWITCH PANEL, NO TROUBLE FOUND.
Back to Boeing MD-90-30