Boeing MD-90-30
Service difficulty reports · 6,066
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM90041120Relay · failedAPU SMOKED THE CABIN CAUSING AN EMERGENCY EVACUATION. REPLACED BAD APU STARTER AND START RELAY.SDR UIA9321Proximity Sensor · malfunctionedAFTER AIRBONE, RAISE GEAR HANDLE UP, NOSE GEAR RED LIGHT ILLUMINATE. A/C AIR TURN BACK, A/C LANDING. PERFORMED TROUBLESHOOTING, FOUND NOSE GEAR PROXIMITY SENSOR FUNCTION NO GOOD IAW AMM 32-60-02. REPLACED NOSE LANDING GEAR DOWN AND LOCKED PROXIMITY SENSOR ANSDR DLM90041056Electrical Sys · failedLEFT ELEC SYSTEM FAILED EN ROUTE. REPLACED LEFT ECU.SDR DLM90041041Strut · dischargedON LANDING GEAR RETRACTION THE RED NOSE GEAR LIGHT REMAINED ON. ACCOMPLISHED ABNORMAL CHECKLIST. RECYCLED LANDING GEAR AND NOSE GEAR LIGHT REMAINED ON, BUT WITH THE ADDITION OF LOUD AIR NOISE. LOWERED LANDING GEAR AND RETURNED TO DFW. CHECKED NOSE GEAR. SSDR DLM90040981Monitor · odorVISIBLE SMOKE COMING OUT OF OVHD PNL 13AB WITH ACRID SMELL. SUSPECT VIDEO MONITOR OR SEAT BELT NO SMOKING LIGHT. REPLACED INOP, ACRID SMELLING VIDEO MONITOR AT 13 AB PER MM. PERFORMED OPS TEST OF ENTERTAINMENT SYS, OPS CHECK NORMAL. SEAT BELT NO SMOKING LISDR DLM90040975Wheel · damagedON OVERNIGHT WALKAROUND TRANSIT CHECK - AMT FOUND DAMAGE TO NR 2 MLG WHEEL ASSY AND BRAKE. DAMAGE OCCURRED WHEN THE INSIDE KEY OF NR 2 WHEEL ASSY HOLDING BOLT SHEARED AND THE KEY BACKED OUT STRIKING THE NR 2 BRAKE ASSY. THE KEY WAS HELD IN PLACE BY THE BRAKESDR DLM90040921Strut · leakingAFTER LIFT OFF NOSE GEAR FAILED TO RETRACT WITH RED NOSE LIGHT REMAINING ILLUMINATED. AFTER FOLLOWING CORRECTIVE PROCEDURES THE NOSE GEAR OPERATED CORRECTLY. FOUND NOSE STRUT FLAT AND VALVE LEAKING. REPLACED O-RING AND RESERVICED STRUT WITH OIL AND AIR. OPSDR DLM90040891Odor · detectedWHILE AT GATE FLIGHT ATTENDANTS REPORT SMELL AND FUMES IN CABIN. SUSPECT LEFT PACK OVERHEAT. REPLACED COALESCER BAGS AND CHECKED ENGINES AND APU FOR LEAKS. NONE FOUND. RAN PACKS FOR 30 MINUTES, NO MORE ODOR. PACK TEMP CONTROLS ARE BOTH GOOD IN AUTO MANUALSDR UIA9316Skin · corrodedDURING C06 CHECK OF DATUM, A/C FOUND SEVERAL CORROSION ON UPPER SKIN (P/N:59305002-150) OF RT WING AT STA XRS=282.SDR UIA9315Skin · corrodedDURING S90M C CHECK OF DATUM A/C 1. REPAIR ON THE RT FUSELAGE SKIN AT STA Y=484,L18R-L19R (526). CORROSION ON LE WING REAR SPAR LOWER CAP AT STA XRS510 AND XRS 550(527).3.A CRACK DAMAGE ON RT FUSELAGE SKIN (P/N:5910228-259) BETWEEN CANTED STA 1520-1531 (529)SDR DLM90040862Insulation · looseFLIGHT ATTENDANT OBSERVED EXTENSIVE AMOUNT OF SMOKE STRONG ODOR AND HOT AIR IN AFT CABIN PRIOR TO BOARDING. FOUND RIGHT A/C SUPPLY DUCT INSULATION OFF AND TAPE ON DUCT REMOVED TAPE AND REPLACED INSULATION.SDR DLM90040824Engine · failedAS POWER WAS PUSHED UP FOR TAKEOFF RIGHT ENGINE OIL PRESSURE LO LIGHT CAME ON AND OIL PRESSURE INDICATED ZERO. SHUT DOWN ENGINE AFTER APPROX 10 SECONDS. REPLACED ACCESSORY GEARBOX.SDR DLM90040773Charger · inoperativeFIRST CLASS FLOOR TRACK EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK AND BATTERY CHARGER FOR FIRST CLASS FLOOR TRACK EMERGENCY LIGHTS. REPAIRED SHORTED WIRE IN FLOOR TRACK, ALL EMERGENCY LIGHTS OPN NORMAL.SDR DLM90040742Wire Harness · arcedPAX NOTICED ARCING AND SMOKE FROM FLOOR NEAR 26C. INSPECTED AREA COULD NOT FIND DAMAGE BUT RT SIDE OF A/C AUDIO ENTERTAINMENT SYSTEM DEAD. REPLACED HARNESS AT ROWS 25-26 FOR ARCING DAMAGE.SDR DLM90040645Terminal · burnedAFTER PUSHBACK STRONG SMELL OF ELECTRICAL FIRE, NO VISIBLE SMOKE. RAN ELECTRICAL FIRE CKLIST, STRONG SMELL NEAR F/C FLIGHT ATTENDANT JUMPSEAT. FOUND APU POWER RELAY PHASE A1 TERMINALS BURNT. REPLACED RELAY BASE AND CONTROL. FWD TO MCO/PLAC 49-10-01. APU ISDR DLM90040640Starter · burnedFIVE MINUTES AFTER FAILED START ATTEMPT SMOKE COMING FROM APU AREA. SMALL FIRE AT APU STARTER EXTINGUISHED WITH DRY CHEM EXT. APU REPLACEMENT IN PROGRESS. REPLACED APU ASSY AND APU START RELAY.SDR DLM90040565Fire Loop · malfunctionedPASSING 3000 FT RT ENGINE FIRE DETECTOR FAULT MESSAGE ILLUM IT STAYED ON FOR APPROX 1 MIN AND THEN WENT OUT. FIRE DET FAULT MESSAGE CAME ON WITH RT ENG B-LOOP LIGHT. LIGHT INTERMITTENT CAME ON AND OFF WITH WITH -B- LOOP. PERFORM FAULT TEST PER T/S MANUAL. SDR DLM90040552Pressure Switch · inoperativeWHILE TAXIING SLOWLY ARMED T/O MODE OF AUTOBRAKES A/C IMMEDIATELY AND ABRUPTLY STOPPED. RECEIVED AUTOBRAKE FAIL MESSAGE ON EOAP. NORMAL BRAKING OPERATES FINE. FAULTS IBCV1 SOV. REPLACED SAME.SDR DLM90040551Transceiver · inoperativeRADAR RT FAIL. REPLACED WXR RADAR RT PER M/M.SDR DLM90040439Fan · shortedSMOKE AND FUMES IN CABIN, TURNED OFF RIGHT PACK AND GALLEY POWER SMOKE STOPPED. FOUND J9 C/B POPPED ON RECIRCULATION FAN. REPLACED SAME.SDR DLM90040391Engine · malfunctionedACS REPORTED TAIL PIPE FIRE NR 2 ENGINE AFTER ENGINE SHUTDOWN. REPLACED ENGINE.SDR DLM90040364Circuit Breaker · trippedRIGHT HYD SYSTEM FAILURE. DECLARED EMERGENCY LANDING, NO HYD. FOUND RIGHT INSTR TRANSFER C/B POPPED. RESET L9 C/B, ALL INDICATIONS. OPERATED PUMPS SYSTEM, CHECKS OK. NO LEAKS FOUND.SDR DLM90040325Tire · cutITEM CUT IN NR 2 MAIN TIRE. REPLACED NR 2 MAIN WHEEL ASSY PER M/M.SDR UIA9311Spar · corrodedDURING C 05 CHECK OF DATUM A/C: FOUND CORROSION ON UPPER SURFACE OF FRONT SPAR OF RT WING AT STA XRS 531. FOUND CORROSION ON UPPER SURFACES OF LOWER SKIN P/N:5935822-50 AND REAR SPAR LOWER CAP OF RT WING AT STA XRS=546. PERMANENT REPAIR ON FUSELAGE SKIN P/SDR DLM90040265Generator · brokenLT GEN FAILED IN CLIMB WITH GEN OFF, LIGHT ILLUMINATED. RESET ONCE UNSUCCESSFUL. VERBAL FROM CREW VIBRATION FELT IN A/C AND YOKE. FOUND GENERATOR BROKEN IN 2 PIECES WITH GEARBOX CONTAMINATED WITH METAL MATERIAL. WILL REQUIRE ENGINE REPLACEMENT.SDR DLM90040237Transmitter · malfunctionedPYLON FLAP FAULT AND ELEVATOR SPLIT MESSAGE CAME ON AT FL310. REMOVED AND REPLACED RT AND LT ELEVATOR POSITION SENSORS PER M/M. ADJUSTED BOTH PER M/M. BOTH LEFT AND RIGHT TRANSMITTERS WITHIN M/M LIMITS. PYLON FLAP TEST CHECK GOOD.SDR DLM90040196Battery · dischargedTHE L1 DOOR EMERGENCY FLASHLIGHT OUTBOARD RED POWER LIGHT DOES NOT BLINK. REMOVED AND REPLACED BATTERY, OPS NORMAL NOW.SDR DLM90040195Lamp · burned outFIVE EMERGENCY TRACK LIGHTS AT SEAT 10 ABC INOPERATIVE. RELAMPED, CHECKS GOOD.SDR UIA9306Spar · corrodedDURING S90M CHECK OF DATUM A/C, FOUND CORROSION, UPPER SURFACE OF FRONT SPAR LOWER CHORD OF LT WING AT STA XRS 509.2. LT WING (STA. XRS 115-601) AND RT WING (STA. XRS 73-477) UPPER SKIN. T/E ALUMINUM STRIP OF RUDDER THAT HAD PENETRATED THROUGH THE ENTIRE THICSDR UIA9305Spar Cap · corrodedDURING S90M CHECK FOUND TWO CORROSION SITES ON AFT EDGE OF RT WING UPPER SKIN AND TWO CORROSION NR 1-NR 4 ON LOWER P/N5935822-506 AND REAR SPAR CAP P/N 5911301-1 UPPER SURFACE OF RT WING NEAR STA XRS=546. PFM THE REPAIR TO CORROSION BLEADOUTS AND TEMPOARY RESDR DLM90040136Hinge · brokenFOUND WHILE WORKING MCO FOR SPOILER DEPLOY MSG. FOUND LEFT INBOARD FLT SPOILER I/B HINGE BROKEN. CAUSED DAMAGE TO THE POSITION SENSOR AND PUNCTURED HOLE INTO O/B FORE FLAP. REPLACING NEXT HIGHER ASSY THE SPOILER AND THE LEFT O/B FORE FLAP.SDR DLM90040108O-Ring · damagedAFTER TAKEOFF NOSE GEAR FAILED TO RETRACT. DURING POM PROCEDURE GEAR HANDLE WOULD NOT RAISE. CONTINOUS T/O AURAL WARNINGS OF FLAPS, STABILIZER, SLATS IN AIR. NO PRESSURIZATION AUTO FAIL INOP 1 AND 2. AUTO SPOILERS INOP OAP MESSAGE. ALSO HAD LEFT AND RIGHTSDR DLM90040091Diode · inoperativeAFT EMERGENCY FLASHLIGHT LED INOP. REPLACED FLASHLIGHT AND BATTERY.SDR DLM90040008Generator · failedRT AC FEEDER FAULT RT ELEC SYSTEM FAIL AND RT GEN OFF MESSAGE ON EOAP. WOULD NOT RESET IN FLT. FOUND METAL IN GENERATOR OIL. REPLACED GENERATOR.SDR DLM90031151Apu · failedAPU ELECTRONICS FAILED 45 MIN AFTER T/O. REPLACED APU AND DOOR ASSY.SDR DLM90031145Battery · inoperativeDURING L/O FOUND 2R & 1L EXTERIOR LIGHTS INOP. REMOVED AND REPLACED EXTERIOR EMERGENCY LIGHTS BATTERY AND BATTERY RACK (B5-125). CHECKS GOOD.SDR UIA9214Vane · crackedDURING ROUTINE CHECK, CORROSION WAS FOUND ON LT IB FLAP OB VANE TRAILING EDGE LOWER SURFACE,LT OB FLAP OB VANE TRAILING EDGE LOWER SURFACE, AND RT IB FLAP OB VANE TRAILING EDGE LOWER SURFACE. REMOVE THE CORRODED AREAS AND MAKE THE REPAIR.SDR DLM90031090Warning Light · inoperativeAFTER ARRIVAL AT GATE AND DURING PASSENGER NORMAL EXIT, RAMP STATED, A TAILPIPE FIRE IN NR 2 ENG. NO FIRE INDICATION OR LIMIT EXCEEDENCE NOTED. TAILPIPE FIM PROCEDURE ACCOMPLISHED IAW POM. ENG WAS ALREADY SHUT DOWN. CLEANED NR 5 BEARING CAVITY AND RAN ENGISDR DLM90031056Battery · dischargedFWD SECTION OF FLOOR TRACK EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK, NOW OPS NORMAL.SDR UIA9210Control Valve · malfunctionedIN AIR 8000 FT CABIN PRESSURE (FLOW) LIT,BOTH PACK OFF. A/C AIR TURNED BACK. IAW AMM 21-51-04 REPLACED R/L FLOW CONTROL VALVE AND GRD ENG RUN-UP FUNCTION TEST NORMAL.SDR UIA9209Frame · corrodedPFM C04 CHK FOUND CORROSION ON FUSELAGE FRAME LOWER TEE CHORD AT STA Y-1437 L29R-L26R, CUT THE CORROSION PORTION OF T-CHRD. TRIM OUT THE INTERCOSTAL FORWARD SIDE, MAKE THE REPAIR PARTS AND INSTALL FASTENERS.SDR DLM90030989Pump · failedLT HYDRAULIC PRESSURE WENT TO ZERO SHORTLY AFTER TAKEOFF. FOLLOWED POM PROCEDURE BUT LT PRESSURE WOULD NOT RETURN. AFTER A FEW MINUTES RT HYD TEMP HI MSG CAME ON. REPLACED LT ENG HYD PUMP AND FILTERS.SDR UIA9208Frame · corrodedPERFORMED C04 CHECK, FOUND CORROSION ON FUSELAGE FRAME LOWER TEE CHORD AT STA Y=1437 L29R-L26R,CUT THE CORROSION PORTION OF T-CHORD. TRIM OUT THE INTERCOSTAL FORWARD SIDE, MAKE THE REPAIR PARTS AND INSTALL FASTENERS.SDR DLM90030977Strut · lowNOSE GEAR FAILED TO RETRACT ON T/O, 3 VGRN WITH GEAR HANDLE DOWN. SERVICED NOSE GEAR PER M/M 32-21-01-619-801, NOSE GEAR OPERATION CHECKS NORMAL.SDR DLM90030931Coalescer Bag · unserviceableAFTER T/O FLT ATTENDANT A/C LEFT MX HANGER. FUMES WERE NOT GETTING STRONGER BUT WERE MORE NOTICEABLE NEAR FLOOR. CONTINUED THROUGHOUT FLIGHT. ADVISED BY MAINT NOT TO START APU ON GROUND. REPLACED RT COALESCER BAG FOR T/S. PERFORMED PNEUMATIC HIGH PRESSURESDR DLM90030897Extinguisher · leakingFD POSITION H2O PORTABLE FIRE EXTINGUISHER LEAKING FLUID. DAL LEAD SEAL INTACT WITH NO EVIDENCE OF ACTIVATION OR TAMPERING. CARTRIDGE CKS OK. REPLACED SAME.SDR DLM90030893Switch · unserviceableRIGHT FUEL PRESSURE LIGHT ILLUMINATED ON TAKEOFF ROLL. REPLACED FUEL FILTER AND PRESSURE SWITCH PER MAINT MANUAL.SDR DLM90030844Bleed Valve · failedNR 2 ENG COMPRESSOR STALLS LESS THAN 1.2 EPR. REPLACED 7TH STAGE BLEED VALVE.SDR DLM90030821Acm · seizedAFTER T/O SMOKE REPORTED IN AFT CABIN. FOUND RT ACM FROZEN. REPLACED ACM AND COALESCER.SDR DLM90030819Bearing · cokedNUMBER ONE ENGINE HAD TAIL PIPE FIRE ON SHUT DOWN. NUMBER 1 ENGINE BEING CHANGED DUE TO EXCESSIVE COKING IN NUMBER 5 BEARING COMPARTMENT PER IAE.
Back to Boeing MD-90-30