SDR DHL2003604513Frame · crackedLT WING CTR L/E FORMER WITH 0.500 INCH CRACK STA XS 478.897. STOP DRILLED CRACK AND FABRICATED DOUBLER ANGLE (2024-T3 AL0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND DOUBLER ANGLE IAW SRM 51-1-8B. INSTALLED DOUBLER ANGLE AT XS 478.897 SDR DHL2003604506Frame · crackedRT WING CTR L/E INNER PART FORMER CRACKED 1.000 INCH, XFS 316.500. STOP DRILLED CRACK AND FABRICATED DOUBLER ANGLE (2024-T3 AL0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND DOUBLER ANGLE IAW SRM 51-1-8B. INSTALLED DOUBLER ANGLE ON RT WISDR DHL2003604504Frame · crackedLT WING CTR L/E FORMER WITH 0.500 INCH CRACK STA XS 491.193. STOP DRILLED AND FABRICATED DOUBLER ANGLE (2024-T3 0.040) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND DOUBLER ANGLE IAW SRM 51-1-8B. INSTALLED DOUBLER ANGLE ON LT WING CTR L/E FORSDR UPS03840487Door · crackedLT FUSELAGE SECONDARY AIR START DOOR CRACKED. REPAIRED PER EO DC8-5330-18680-ASDR DHL2003801011Skin · corrodedRT OUTER WING INBOARD L/E OUTER PLATING CORRODED AT STA XW 485.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EODHL 030405, ED 3260. REMOVED FASTENERS IAW SRM 51-1-21 PG 2. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 57-2-0 PG 16SDR DHL2003604503Frame · crackedLT WING OUTBOARD L/E FORMER AT STA XFS 835.000 CRACKED 0.500 INCH. STOP DRILLED CRACK AND FABRICATED DOUBLER ANGLE (2024-T3 AL0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND DOUBLER ANGLE IAW SRM 51-1-8B. INSTALLED DOUBLER ANGLE AT XFS 8SDR DHL2003604518Frame · crackedLT WING OUTBOARD L/E FORMER AT STA XFS 722.500 CRACKED 0.500 INCH. STOP DRILLED CRACK AND FABRICATED DOUBLER ANGLE (2024-T3 AL0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND DOUBLER ANGLE IAW SRM 51-1-8B. INSTALLED DOUBLER ANGLE AT XFS 7SDR DHL2003604516Frame · crackedLT WING OUTBOARD L/E FORMER AT STA XFS 735.000 CRACKED 0.500 INCH. STOP DRILLED CRACK AND FABRICATED ANGLE-DOUBLER (2024-T3 AL0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10, SRM 51-SDR DHL2003604515Frame · crackedLT WING OUTBOARD L/E FORMER AT STA XFS 866.250 CRACKED 0.500 INCH. STOP DRILLED CRACK AT XFS 866.250. FABRICATED ANGLE DOUBLER (2024-T3 0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-SDR DHL2003806006Lamp · will not testNR 5 SMOKE DETECTOR WILL NOT TEST. DEFERRED NR 5 SMOKE DETECTOR PER MEL 26-6-2, ASSIGNED CONTROL 12688, CAT-C. PLACARD INSTALLED. REFER TO DMI 12688. NR 5 SMOKE DETECTOR WILL NOT TEST. RELAMPED NR 5 SMOKE DETECTOR AND TESTED GOOD AS PER M/M 26-10-5. THISSDR DHL2003801014Fitting · crackedLT FLAP HINGE SUPPORT FITTING LWR SUPPORT ANGLE AT STA XF 97.000 CRACKED. REMOVED AND REPLACED LT FLAP HINGE SUPPORT FITTING LWR SUPPORT ANGLE AT XF 97.000 IAW MM 20-16-0 PG 207. REFER O N/R 0075 FOR OPS CHECK.SDR DHL2003801005Door Frame · crackedFWD SERVICE DOOR JAMB WITH 2.000 INCH CRACK IN AFT LWR CORNER STA 180.000 L-20R- L-21R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW DWG SR08530021, SRM 53-2-0 FIG 14. CUT OUT DAMAGED AREA IAW DWG DACCO SR08530021, SRM 53-2-0 FIG 14. FABRICATED FILLER, DOUBLERSDR DHL2003801069Fitting · crackedAFT ACCY COMPT - SPLICE FITTING CRACKED 1.000 INCH FS 1690.000 L-18L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1. REMOVED DAMAGED SPLICE FITTING SRM 51-1-21 PG 1. CLEAN, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM SDR DHL2003604512Frame · crackedLT WING OUTBOARD L/E FORMER AT STA XFS 797.500 CRACKED 0.500 INCH. STOP DRILLED CRACK AND FABRICATED ANGLED DOUBLER (2024-T3 0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10, SRM 51-1SDR UPS03840678Fitting · crackedINSPECTION TYPE: C1, LT WING AT STA. XRS 74 OB SIDE STRINGER 51 END FITTING IS CRACKED. REMOVED AND REPLACED FITTING I.A.W. DWG. 3704841, AND SRM. 51-1-20DSDR DHL2003801030Fitting · crackedLT STUB WING UPPER SURFACE ZEE PAN WITH 2.000 INCH CRACK STA XS 250.089. REMOVED DAMAGED ZEE PAN FITTING IAW SRM 51-3-0 PG 1, SRM 51-1-21 PG 1, SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW ZEE PAN FITTING IAW SRM 51-3-SDR DHL2003801026Fitting · crackedMAIN CARGO COMPT FITTING ATTACHING FRAME TO RT CUSP EXTRUSION AT STA 702.875 WITH 2.000 INCH CRACK. REMOVED DAMAGED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D PG 9.SDR UPS03840637Fitting · crackedINSPECTION TYPE: C1, LT WING FITTING AT REAR SPAR AT XRS 446 AT REAR SPAR REMOVED,FABRICATED AND REPLACED FITTING I.A.W. DWG. 4640309 AND SRM. 51-1-20DSDR DHL2003805007Fire Detector · will not testNR 7 MAIN DECK CARGO COMPARTMENT FIRE DETECTOR DOES NOT TEST. DEFERRED NR 7 FIRE DETECTOR AS PER MEL 26-6-1 ASSIGNED DMI 12660 PLACARD PANEL. REF DMI 12660, NR 7 MAIN DECK CARGO COMPARTMENT FIRE DETECTOR DOES NOT TEST. OPS CHECKED NR 7 SMOKE DETECTOR PER DASDR DHL2003801029Fitting · crackedD-BELLY DOOR INTERNAL STRUCTURE HINGE SUPPORT FITTING CRACKED. REMOVED CRACKED FITTING IAW SRM 51-1-21 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING ON D-BELLY DOOR INTERNAL STRUCTURE HINGE SUPPORT IAW SRM 51-1-21 PG 1.SDR DHL2003801028Fitting · crackedRT WING CTR L\E ZEE PAN CRACKED 3.500, STA XS 520.168. REMOVED AND REPLACED DAMAGED ZEE PAN FITTING AT STA XS 520.168 (RT WING CTR L\E IAW 51-1-21 PG 1 AND SRM 51-1-20D PG 9 AND 21.SDR DHL2003801024Skin · corrodedLT OUTER WING INBOARD L/E OUTER PLATING CORRODED AT STA XW 485.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EODHL 030402, ED3253. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 57-2-0 PG 16.SDR DHL2003801008Skin · damagedLT WING CTR L/E SKIN SHOW ELONGATED HOLES AND INTERIM REPAIR AT XW 257.500 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EO DHL 030409, ED 3257. REMOVED INTERIM REPAIR IAW SRM 51-1-21 PG 1. CUT OUT DAMAGED AREA IAW EO DHL 030409, ED 3257. CLEANED, TREATED ANDSDR UPS03840475Skin · crackedINSPECTION TYPE: C3 L-1 DOOR LWR AFT CORNER SKIN CRACKED 2 EA BY CUTOUT MARKED. REPAIRED LOWER AFT DOOR CORNER IAW DC8 SRM 53-2-0 FIG 15, TR 53-128, TR 53-155 AND REO G09193SDR UPS03840459Shear Tie · crackedINSPECTION TYPE: C3, APPROX. STA 700, LONG 35 RT, SHEAR TIE (FRAME ANGLE) UNDER STRESS PN L IS CORRODED AND CRACKED REMOVED DAMAGED SECTION OF SHEAR TIE IAW DC8 SRM 51-1-20D, FABBED NE W SECTION IAW DWG 9753780, LOCATED AND DRILLED UP NEW SECTION IAW D WGSDR DHL2003801027Frame · crackedLT WING OUTBOARD STUB WING FORMER CRACKED, STA XS 520.168. STOP DRILLED CRACK IAW SRM 57-2-0 PG 9-10. FABRICATED REINFORCING ANGLE (7075-T6 0.090) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED REINFORCING ANGLE IAW SRM 57-2SDR DHL2003801025Skin · corrodedRT OUTER WING INBOARD L/E OUTER PLATING SHOWS CORROSION AT XFS 710.000. PERFORMED MAJOR REPAIR IAW EODHL-030403, ED3261. REMOVED FASTENERS, REMOVED CORROSION FROM RT OUTER WING INBOARD L/E OUTER PLATING. FOUND OUT OF LIMITS IAW SRM 57-2-0 PG 16. CUT OUT COSDR DHL2003801009Vane · damagedLT WING L/E INBOARD VANE SKIN SHOWS ELONGATED HOLES AT STA XS. 247.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EODHL 030413, ED3259. REMOVED FASTENERS IAW SRM 51-1-21 PG 2. CUT OUT DAMAGED AREA IAW EODHL 030413, ED3259. CLEANED, TREATED AND PRIMED AREA SDR DHL2003801021Vane · damagedLT WING L/E OUTBOARD VANE UPPER SKIN SHOWS ELONGATED HOLES AT STA XOLDI 6.224 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EO DHL 030408, ED-3264. CUT OUT DAMAGED AREA IAW ED DHL 030408, ED-3264. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, FABRICATED FISDR DHL2003801020Vane · damagedLT WING L/E OUTBOARD VANE SHOWS ELONGATED HOLES AT STA XOLDO 67.0 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EO DHL 030410, ED-3265 CUT OUT DAMAGED AREA IAW EO DHL 030410, ED 3265. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED FILLER (7075-T6SDR DHL2003801013Skin · corrodedLT WING INBOARD FLAP UPPER SKIN CORRODED STA XW 2.000 TO XW 91.000 LT (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EO DHL 030407, ED 3263, REMOVED CORROSION IAW SRM 51-1-8 PAGES 17, 18 FOUND OUT OF LIMITS IAW SRM 57-2-0 PAGE 16. REMOVED CORRODED SKIN IAW SRM 5SDR DHL2003801010Vane · corrodedLT WING INBOARD FLAP VANE UPPER PLATING CORRODED STA XW 104.000 - XW 115.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EODHL 030406, ED 3282. REMOVED CORROSION ON INBOARD FLAP UPPER PLATING IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 57-2-0 PG 16.SDR DHL2003801022Skin · corrodedLT OUTER WING OUTBOARD L/E UPPER PLATING CORRODED AROUND STA XFS 710.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EODHL 030414, ED 3267. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 57-2-0 SDR DHL2003801023Skin · corrodedLT OUTER WING OUTBOARD L/E OUTER PLATING CORRODED AT STA XFS 710.000. PERFORMED MAJOR REPAIR IAW EODHL 030401, ED3255. REMOVED CORROSION ON LT WING OUTBOARD L/E STA XFS 710.000 IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 57-2-0 PG 16. CUT OUT CORRSDR DHL2003801018Skin · damagedLT WING CTR L/E LWR PLATING SHOW ELONGATED HOLES AT STA XFS 526.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW EODHL 030411, ED3266. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED DOUBLER (7075-T6 AL0.0SDR DHL2003801012Skin · corrodedLT OUTER WING OUTBOARD L/E OUTER PLATING CORRODED AT STA XW 761.000. PERFORMED MAJOR REPAIR IAW EO DHL 030404, ED 3254. REMOVED CORROSION FROM LT WING OUTBOARD L/E OUTER PLATING IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 57-2-0 PG 16. CUT OUT DAMSDR UPS03840628Fitting · crackedINSPECTION TYPE: C1, INTERCOSTAL ATTACH FITTING IS CRACKED AT STA. 1230 LONG. 33R REMOVED AND REPLACED FITTING IAW DWG. 4758514,AND SRM. 51-1-20DSDR UPS03840616Skin · damagedINSPECTION TYPE: C1, REPAIR DOUBLER AT FS 237 AT LONG. 5R HAS BLIND FASTENERS AND DOES NOT COMPLY WITH SRM. PER. EO. DC8-5330-12800-D REMOVED EXISTING DOUBLER,CUTOUT DAMAGE,NDT VERIFIED NO CRACKS AT CUTOUT,FABRICATED DOUBLER,FILLER,AND FINGER DOUBLER I.A.SDR UPS03840470Fitting · crackedINSPECTION TYPE: C1, STATION 380-400 LONGERON 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG. 3754473 AND SRM. 51-1-20DSDR UPS03840630Skin · misrepairedINSPECTION TYPE: C1, MAIN CARGO DOOR OPENING AFT LOWER CORNER STA. 270 HAS A STAINLESS STEEL DOUBLER THAT DOES NOT COMPLY IAW DC8-5330-12800-D LONG. 20L-21L APPROX. REMOVED EXISTING REPAIR,NDT VERIFIED NO CRACKS AROUND EXISTING CUTOUT,FABRICATED DOUBLERS SDR UPS03840629Fitting · crackedINSPECTION TYPE: C1, STA. 660 - 680 LONG. 11 LT SPLICE FITTING IS CRACKED REMOVED AND REPLACED FITTING I.A.W. DWG. 5750540,AND SRM. 51-1-20DSDR UPS03840482Angle · crackedINSPECTION TYPE: C1, RT WING CENTER LE. SUPPORT ANGLE AT XS 520 IS CRACKED. REMOVED,FABRICATED AND REPLACED ANGLE IAW DWG. 9753297,AND SRM. 51-1-20DSDR UPS03840452Skin · crackedINSPECTION TYPE: C1, FREON SYSTEM EXHAUST DOOR AFT LOWER CORNER STA 55 HAS A STAINLESS DOUBLER, DOES NOT COMPLY IAW EO DC8-5330-12800-D, AND IS CRACKED AT STA 52. REMOVED EXISTING REPAIR, FABRICATED AND INSTALLED DOUBLER AND FILLER IAW SRM 53-2-0 FIG 13, NDT SDR DHL2003801038Frame · crackedLT WING - CTR L/E FORMER WITH 2.000 INCH CRACK IN STA XFS 310.250. STOP DRILLED CRACK IAW SRM 57-2-0 PG 9-10. FABRICATED REINFORCING ANGLE (7075-T6 0.040) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED REINFORCING ANGLE IAW SDR DHL2003801033Frame · crackedTAIL CONE LT FRAME WITH 2.000 CRACK IN STA 1937.000. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. STOP DRILLED CRACK AT STA 1937.000 IAW SRM 53-2-0 PG 1B. FABRICATED DOUBLER (2024-T3 AL 0.040) IAW SRM 53-2-0 PG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. SDR DHL2003801034Frame · crackedTAIL CONE LT FRAME WITH 0.500 INCH CRACK IN STA 1961.000. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. STOP DRILLED CRACK AT STA 1961.000 IAW SRM 53-1-0 FIG 1B. FABRICATED DOUBLER (2024-T3 AL0.040) IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1SDR DHL2003801039Frame · crackedTAIL CONE RT FRAME WITH 0.750 INCH CRACK IN STA 1940.000. REMOVED FASTENERS IAW SRM 51-1-21A PG 1-4, SRM 51-1-21 PG 1. STOP DRILLED CRACK AT STA 1940.000 IAW SRM 53-2-0 FIG 1B. FABRICATED DOUBLER (2024-T3 AL0.040) IAW SRM 53-20 FIG 1B. CLEANED, TREATED ANDSDR UPS03840643Skin · crackedINSPECTION TYPE: C1, R-2 DOOR UPER AFT CORNER FOUND 1.450 INCHES AND 1.740 INCHES CRACKS IN SKIN AND LONG. 11R AT STA. 1660 CUTOUT DAMAGEIN SKIN AND STOP DRILLED CRACK IN LONG. 11R,NDT VERIFIED NO CRACKS AT CUTOUT AND STOP DRILL TERMINATES CRACK IN LONG.,SDR UPS03840484Skin · crackedINSPECTION TYPE:C1 REMOVE L-2 DOOR LOWER FWD. CORNER DOUBLER AND REPAIR PER SRM. 53-2-0 FIG. 18 CUTOUT DOES NOT CONFORM,STA. 1620 LONG. 20L. REMOVED EXISTING REPAIR,CUTOUT DAMAGE, NDT VERIFIED NO CRACKS AT CUTOUT, FABRICATED AND INSTALLED DOUBLER, TRIPLESDR UPS03840466Fitting · crackedINSPECTION TYPE: C1, STATION 1700 LONGERON 11L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG. 4772397 AND SRM. 51-1-20D
Back to Douglas DC-8-73F