SDR RRXA000584Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOORBOARD AT STA 1020 TO 1300 AND LONGERON BL-0 AND BL-R 10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED HEAVY EXFOLIATION CORROSION, ALODINED, PRIMED AREA AND REPLACED IAW DC-8 SRM 51-1-8. (CORROSSDR UPS00832090Floorbeam · corrodedINSPECTION TYPE: C 123 FLOORBEAM LOWER SURFACE CORROSION FS 680 RBL 46. REMOVED DOUBLER , MATERIAL ID FOR NEW ANGLE 7075-0 .100 PO NR 312186 IAW DAC DWG 5773275 FORMED IAW DC8 SRM 51-1-4. HEAT TREATED IAW TPS-1003. FABRICATED ANGLE IAW DAC DWG 5773275.SDR RRXA000610Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN DECK SEAT TRACK AT STA 680 TO 820 AND RBL 60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 8A. (COSDR UPS00832167Floorbeam · corrodedINSPECTION TYPE: C123, AFT CARGO BAY, CORROSION ON UPPER FWD FLOORBEAM FLANGE AT FS 1540 RBL 50. REMOVED CORRODED SECTION OF FLOORBEAM FLANGE IAW REO G07207. ALODINED & PRIMED IAW DC8 SRM 51-1-8. PERFORMED HFEL IAW NAT SRM 06-10-01.001. NO CRACKS NOTEDSDR UPS00832164Fitting · crackedINSPECTION TYPE: C123, AFT CARGO BAY FWD FITTING AT FS 1240 LONGERON 35 RT CRACKED. REMOVED FITTING. LOCATED & DRILLED IAW DC8 SRM 51-1-24 NEW FITTING & INSTALLED FITTING IAW DC8 SRM 51-1-20D.SDR UPS00832136Intercostal · corrodedINSPECTION TYPE: C123 AFT PIT FS 1240 - 1260 CORROSION ON LOWER SURFACE OF UPPER INTERCOSTAL FLANGE AT LONGERON 33 RT. REMOVED CORRODED INTERCOSTAL, FABRICATE NEW INTERCOSTAL, LOCATED & DRILLED EXISTING FASTENERS HOLES. ALODINED & PRIMED INTERCOSTAL & ISDR UPS00832135Fitting · crackedINSPECTION TYPE: C123, AFT CARGO BAY FS 1160 RT FLOORBEAM END FITTING CRACKED. REMOVED FLOORBOARD STA 1000 - 1300 RT IAW DC8 SRM 51-3-0, REMOVED CRACKED FITTING IAW DC8 SRM 51-1-20D & 51-1-21. LOCATED & DRILLED NEW FITTING PN 3754946-501N. INSTALLED FITTSDR UPS00832097Seat Track · wornINSPECTION TYPE: C 123 SEAT TRACK HAS SEVERAL BARE METAL AREAS, STA 680 TO 980. CLEAN BARE METAL, FOUND OUT OF LIMITS IAW DC8 SRM 53-2-3. REPLACED & INSTALLED SEAT TRACK & CHANNEL SPLICE IAW DC8 SRM 51-3-0.SDR RRXA000706Plate · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE AT THE FWD ENTRY DOOR LOWER FWD DOOR JAMB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED, PRIMED AND ALODINED AREA IAW DC-8 SRM 51-1-8. REBLENDED GOUGE AND FOUND TO BE WITHIN LIMITS IAW DC-8 SRM 53SDR RRXA003734Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT UPPER WHEEL WELL SURFACE HAT CHANNEL ANGLE BRACKET AT STA 880-860 AND -Z 9 INCH, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PARSDR RRXA003733Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT MAIN SUPPORT FRAME 69 INCHES FROM C/L ANGLE AT STA 900, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21SDR UPS00832003Frame · corrodedINSPECTION TYPE:C123, AFT ASSY COMPT STA 1560-1580 LHBL 58 UNDER FLOOR CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8. REMOVED AND REPLACED SEAT TRACK STA 1470-1580 IAW DC8 SRM 53-2-3. ALODINED AND PRIMED IAW DC8 SRM 51 -1-8.SDR RRXA002164Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT WING LEADING EDGE SKIN AT THE INBD PRESSURE FUELING RECEPTICAL CUT OUT AT XRS 261, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IASDR RRXA002163Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN 2 PLACES TO THE MAIN CABIN FLOOR PANEL AT FWD ENTRY DOOR AT FS 25-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 51-1-21, 51-1-20DSDR RRXA002162Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE DRAIN PLUG HOLE ON THE MAIN CABIN FLOOR PLANK AT BS 1200 AND RBL 10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 51-1-21, 51-1-SDR RRXA002153Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOOR PLANK AT FS 850-879 AND LBL 26-27, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 53-2-3.SDR RRXA002152Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOOR PLANK AT FS 987-990 AND LBL 16-19, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW 53-2-3.SDR RRXA000705Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON LT TOP SIDE OF NOSE RADOME AREA CANTED WEB ABOVE GLIDESLOPE ANTENNA, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRED DOUBLER AND FILLER.SDR RRXA000704Tip Cap · crackedDURING A MAINTENANCE VISIT FOUND A BARE STATIC WICK AND A DOUBLER MISSING AT THE T/E AT STA XW 773, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED, FABRICATED AND INSTALLED DOUBLER AND REPLACED STATIC WICSDR RRXA001745Skin · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE RT WING LEADING EDGE SKIN AT THE INBD PRESSURE FUELING RECEPTICAL AT XRS 261, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW SDR RRXA001744Floorboard · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK IN TWO PLACES TO THE MAIN CABIN FLOOR PANEL AT FWD ENTRY DOOR AT FS 25 TO 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL ISDR RRXA001730Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOORBOARD, FS 850 TO 879 AND LBL 26 TO 27, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER AND FILLER IAW DSDR RXAA000588Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN SEAT TRACK BETWEEN STA 1260 TO 1370 AND LONGERON BL-R 60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED MAIN CABIN SEAT TRSDR RRXA000580Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN FLOORBOARD AT STA 280 TO 415 AND LONGERON RBL 58 TO 63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED MAIN CABIN FLOORBOARD AND INSTALLESDR RRXA000579Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN CABIN FLOORBOARD AT STA 200 AND LONGERON RBL 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED, REPAIRED DOUBLER AND FILLER AND INSTALLED IAW SDR RRXA003368Support · corrodedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE GILINGER SUPPORT BRACKET AT BOTTOM OF FLOOR FRAME AT STA 520-640 X-48 AND +48, DAMAGE EXCEEDED LIMITATIONS IAW DC-8S RM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PASDR RRXA002165Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK APPROX. 2 IN. LONG ON THE FWD WEB OF THE RT MAIN LANDING GEAR DOOR UPLOCK TORQUE BOX IN RADIUS OF THE ATTACH FLANGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATESDR RRXA000708Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON THE LT WING L/E INTERNALLY 28 1/2 INCHES FWD OF WING SPAR UPPER CORD AT XILD .7095, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DSDR RRXA000702Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE WEB ANGLE AT STA 357, AND XFS -60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ANGLE IAW DC-8 SRM 53-3-3 FIG 1, 51-1-8 AND 51SDR RRXA000701Channel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SUPPORT CHANNEL IN 'B' PIT AT STA 620 AND LONGERON 27L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATED AND INSTALLED DOUBLER IAW DC-8 SDR RRXA000700Bracket · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN BRACKET FOR WINE CLAMP AT STA 70 AND LONGERON 31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW BRACKET AND INSTALLED IAW DC-8 SRM 51-1-8.SDR RRXA003732Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT FLOOR PANEL LT AT STA 1688 X TO +26, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4 AND 53-2-0. (CORRSDR RRXA000587Shear Tie · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE SHEAR TIE AT STA 280 AND BETWEEN LONGERONS 33 RIGHT TO 34 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW SHEAR TIE PER DWSDR RRXA000586Shear Tie · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO SHEAR TIE AT STA 300 AND BETWEEN LONGERONS 33 RIGHT TO 34 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED SHEAR TIE PER DWG 3755824. (CORROSIONSDR RRXA000582Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FITTING AT STA 320 AND BETWEEN LONGERONS 34 RIGHT AND 33 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM SDR RRXA000581Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 280 AND LONGERON 32 RIGHT TO 33 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW BATH TUB FITTING AND INSTALLED IAW DSDR RRXA000573Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO END FITTING JUST FWD OF STA 70 AND LONGERON 35 RIGHT AND 35 LEFT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTINGS AND INSTALLED IAW DC-8 SSDR UPS00832002Web · crackedINSPECTION TYPE:C123, CUSP WEB STA 1580 RBL 60 HAS A CRACK. REPAIRED AREA IAW DC8 SRM 53-2-0. ALODINED AND PRIMED IAW DC8 SRM 51-1-8.SDR RRXA000190Relay · failedON T/O DURING ROTATION, STICK SHAKER WENT OFF AT 5-8 DEG OF ROTATION. ON APPROACH AND LANDING STICK SHAKER WENT OFF CONTINUOUSLY BELOW 180 KIAS AND STOPPED RINGING/SHAKING AT GROUND SHIFT. REMOVED AND REPLACED STALL WARN MODE TRANSFER RELAY R2-351, OPS CKS GSDR RRXA000189Transducer · malfunctionedON T/O DURING ROTATION, STICK SHAKER WENT OFF AT 5 DEG - 8 DEG OF ROTATION. ON LANDING AND APPROACH STICK SHAKER WENT OFF CONTINUOUSLY BELOW 160 KIAS. REMOVED AND REPLACED LIFT TRANSDUCER AND STALL WARNING COMPUTER. SYSTEM OPS CHECK NORMAL IAW DC-8 MM CHAPTSDR RRXA002166Skin · crackedDURING A MAINTENANCE VISIT FOUND A 5 INCH CRACK TO THE LWR SURFACE OF THE RT WING LEADING EDGE SKIN APPROX. 16 INCHES FWD OF THE WING FRONT SPAR AT XRS 255, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATEDSDR RRXA000697Intercostal · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN INTERCOSTAL IN THE RADIUS OF TOP FLANGE STA 89 AND LBL 18, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 53-2-0 FIG 1B, 51-SDR RRXA003736Intercostal · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LEFT INTERCOSTAL ON THE AFT LOWER CARGO BILGE AT STA 1240 TO 1260 L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALSDR RRXA003731Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT LOWER SURFACE I/B AUX TANK AT STA XFS 107.5 TO 116.5 AND SCREWS PULLING THROUGH SKIN AT STA XFS 88 TO XFS 132, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DCSDR RRXA001746Skin · crackedDURING A MAINTENANCE VISIT, FOUND A 5 INCH CRACK ON THE LWR SURFACE OF THE RT WING LE SKIN APPROX. 16 INCHES FWD OF THE WING FRONT SPAR AT XRS 255, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANSDR RRXA000615Doubler · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LEFT WING DOUBLER AT STA XRS 74 BETWEEN STRINGER 58 AND REAR SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED AND INSTALLED DOUBLER IAW DC-8 SSDR RRXA000583Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO RT CUSP AT STA 1010 TO 990. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED RT CUSP SECTION IAW DC-8 SRM 53-2-5 FIG 15. (CORROSION DAMASDR RRXA000572Floorbeam · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR SUPPORT BEAM ON AFT SIDE AROUND FASTENERS AT STA 1746 FROM LONGERON BL-L 1 TO BL-R 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTSDR UPS00832092Seat Track · corrodedINSPECTION TYPE: C 123 SEAT TRACK AT STA 1575 HAS CORROSION AROUND SEAT TRACK PLUG, FOUND OUT OF LIMITS IAW DC8 SRM 53-2-3. CUT SEAT TRACK AT FS 1550 & AT PRODUCTION SPLICE AT 1590. FABBED FWD SPLICE PER DC8 SRM 53-2-3. LOCATED, DRILLED & INSTALLED NEW SDR UPS00832088Seat Track · corrodedINSPECTION TYPE: C 123 CORROSION GROUND NUT PLATES FROM STA 1580 TO 1620 BL 0 AFT ACCESSORY BAY CORRODED BEYOND LIMITS. REMOVED CORROSION, FOUND OUT OF LIMITS IAW DC8 SRM 53-2-3. REMOVED & REPLACED SEAT TRACK.
Back to Douglas DC-8-73F