SDR RRXA99487Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LONGERON AT STA 460 BL 21R TO 22R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FRAME REPAIR SPLICES IAW DC8 SRM 53-2-0 FIG 2, 51-1-8 ANSDR RRXA99480Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO SEAT TRACK A RIGHT TUNNEL AT STA 1100, X+59 TO +62, Z+1.1 TO +1.3. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SPLICE AND DOUBLER IAW DSDR RRXA99479Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GILLINER ATTACH ANGLE AT STA 1220 BL 27R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ATTACH ANGLE IAW DAC DWG 5750725, DC8 SRM 51-1-3 SDR RRXA99478Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LONGERON 26R AT STA 1240 TO 1260 BL 26R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR SPLICES IAW DC8 SRM 53-2-2 FIG 10. (CORROSSDR RRXA99477Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FITTING IN AFT PIT AT STA 1450 BL 25R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. DRILLED AND INSTALLED NEW FITTING IAW DC8 SRM 51-3-2, 53-4-1 FIG 44C, AND 51-SDR RRXA99475Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO CUSP IN RIGHT TUNNEL DOOR FRAME IN AFT PIT AT STA 1220 BL 21R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).SDR RRXA99463Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO RIGHT END FITTING ON LONG 14R AT STA 70 TO 80. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 51-1-21, 51-1-20D, 51-3-SDR RRXA99461Fitting · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO RIGHT END FITTING AT STA 70 TO 80 BL 3R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).SDR RRXA99460Intercostal · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AND GUSSETS AND CARGO NET ATTACH FITTING AT STA 80 TO 100 BL17L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR INTERCOSDR RRXA99436Gusset · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GUSSET AT STA 1200, BL 14L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR GUSSET IAW DAC DWG 5887374DC-8 SRM 51-1-21. (CORROSION SDR RRXA99486Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO WALL ATTACH ANGLES FOR GILL LINER AT STA 980 BL 27L TO 27R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ATTACH ANGLES IAW DAC DWG 57047SDR RRXA98080Retract Mech · lack of lubeON GEAR UPLATCH CHECK, GEAR FAILED CHECK IN COMPLIANCE WITH GEAR UPLATCH FAILURE CHECK LIST GEAR CONTINUED TO FAIL UPLATCH CHECK AND SOUNDED AS THOUGH NOSE GEAR DOORS WERE OPEN AND/OR NOSE GEAR EXTENDED WHILE IN THE GEAR UP POSITION. IN COMPLIANCE WITH THE QRSDR RRXA99484Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO T-BOX FITTING IN AFT PIT AT STA 1445 BL 30R TO 31R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 51-1-20D. (CORROSISDR RRXA99443Gusset · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GUSSET AT STA 918 TO 922 BL 12L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR GUSSET IAW DAC FWG 9753292-30-8 DC8 SRM 51-1-24 ANDSDR RRXA99441Gusset · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND DRILL MARKS TO GUSSET AND INTERCOSTAL AT STA 940 TO 960 BL 13L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR GUSSET IAW DAC DWG SSDR RRXA99440Gusset · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GUSSET AND INTERCOSTAL AT STA 1000 BL 19L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR GUSSET IAW DC8 SRM 51-1-24 AND 51-1-20D. SDR RRXA99439Gusset · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GUSSET AT STA 1040 BL 17L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR GUSSET IAW DAC DWG 5779948 AND 51-1-21. (CORROSION DAMAGESDR RRXA99438Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 1040 TO 1060, BL 17L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLES IAW DC-8 SRM 53-2-0 FIG 1B AND 51-1-SDR UPS98826524Angle · corrodedINSPECTION TYPE-C, STA 1320 LWR FWD FLANGE OF FLOORBEAM HAS EXFOLIATION CORROSION BL 0 TO RBL 36. REMOVED, FABRICATED AND INSTALLED REPLACEMENT ANGLE IAW DWG 9887940 AND SRM 51-9-0.SDR RRXA98258Frame · crackedDURING A MAINTENANCE VISIT, FOUND FRAME CRACKED AT STA 80 AND LONGERON 21 RIGHT. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLERS, BONDED IAW DC-8 SRM 53-2-0 AND 51-1-21. TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA99492Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO CROSS SLIDE DOOR WEB AT STA 302 TO 306 BL 33R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER AND FILLER IAW DC8 SRM 53-2-0, 51-1-SDR RRXA99491Intercostal · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 340 TO 348 BL 35L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW INTERCOSTAL IAW DC8 SRM 51-1-20D. (CORROSION DAMAGE RECORDED INSDR UPS98826503Skin · corrodedINSPECTION TYPE:D, FUSELAGE SKIN EXFOLIATED BELOW EXISTING CUTOUT AT LG 27R BETWEEN F/S 25-35. REPAIRED IAW DHC SK-803-047.SDR UPS98826504Former · crackedINSPECTION TYPE:D F/S 55 FRAME FORMER CRACKED BETWEEN LONGERON 27-28 RT. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FORMER IAW SRM 53-2-0.SDR UPS98826505Longeron · corrodedINSPECTION TYPE:D, CORROSION REMOVAL BEYOND LIMITS LONGERON 31R F/S 8-70. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT LONGERON IAW SRM 51-1-21 AND DWG 5613861.SDR UPS98826484Fitting · crackedINSPECTION TYPE:C, INBD LONGERON TO BULKHEAD FITTING IS CRACKED F/S 70 L-31R. REMOVED AND REPLACED FITTING IAW SRM 51-1-21.SDR UPS98826469Longeron · corrodedINSPECTION TYPE-D, LONGERON 27R EXFOLIATED FS 35 TO 70. REMOVED AND REPLACED LONGERON IAW SRM 51-1-21.SDR UPS98826522Doubler · crackedINSPECTION TYPE-C, FINGER DOUBLER IS SPLIT IN HALF FROM STA 8 TO STA 70 AT STR 31R. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FINGER DOUBLER IAW DWG 5644931 AND SRM 53-3-3 FIG 1.SDR UPS98826506Doubler · corrodedINSPECTION TYPE:D, F/S 35-55 A/C DOUBLER HAS HEAVY CORROSION UNDER NUTPLATES UNDER O/B FLANGE OF LONGERON 30R. REMOVED, FABRICATED, AND REPLACED DOUBLER IAW SRM 51-1-20D AND DWG 5649028.SDR RRXA98137Skin · dentedDURING A MAINTENANCE VISIT, FOUND DENT 8 INCHES FROM STATIC PORT CENTER, AT STA 257 BETWEEN LONGERONS 27 LEFT AND 28 LEFT. REMOVED DAMAGED SKIN, FABRICATED AND INSTALLED DOUBLER REPAIR IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-04584.SDR RRXA99437Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO L ANGLE AT STA 1040, BL 14L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE IAW DC-8 SRM 53-4-1, FIG 35, AND 51-1-20D. (CORRSDR RRXA99434Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FLOOR PANEL AT STA 1260 TO 1250, X+21, Z+1. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-0 AND 53-3-0. SDR RRXA98257Support · crackedDURING A MAINTENANCE VISIT, FOUND C-2 CARGO DOOR, UPPER ROLLER SUPPORT FLANGE CRACKED. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 52-4-1, FIGURE 3. TREATED AERA IAW DC-8 SRM 51-1-8.SDR UPS98826525Skin · corrodedINSPECTION TYPE-C, THE FUSELAGE SKIN AT STA 850 AND STR 24L JUST ABOVE THE WING HAS HEAVY CORROSION. REPAIRED AREA IAW 8110-3 APPROVED DHC SK803-975.SDR UPS98826391Angle · crackedINSPECTION TYPE-C, WEB SUPPORT ANGLE IS CRACKED IN 2 PLCS AT STA 310 AND 330 STR 26L. REMOVED, FABRICATED AND INSTALLED REPLACEMENT ANGLES IAW DWG 9751879 AND SRM 51-1-21.SDR RRXA99435Floor · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO CABIN AREA FLOOR BOARD AT STA 1220 TO 1232, X+51.5 TO +57.5, Z+0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SSDR UPS98826498Angle · crackedINSPECTION TYPE:D, RIB SUPPORT ANGLE CRACKED AT RT STUB WING XFS 252.00. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT ANGLE IAW SRM 51-1-20 D AND 9753294.SDR RRXA99483Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LEFT AFT PIT TUNNEL AT STA 1050, Z-1, BL 45L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SEAT TRACK AND SPLICES IAW DC8 SRM 53-2-3 FIGSDR RRXA99474Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BOTTOM OF FLOOR TRACK IN LEFT AFT PIT TUNNEL AT STA 1003, X+62, Z-1. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SEAT TRACK AND SPLSDR RRXA99464Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO END FITTING ON LONG 6L AT STA 70. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW FITTING IAW DC8 SRM 51-1-21 AND 51-1-20D. (CORROSION DAMAGE RECORDESDR RRXA99455Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO SPLICE AT STA 310 BL 7L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. LOCATED SPLICE AND INSTALLED IAW DC8 SRM 51-1-24 AND 51-1-20D. (CORROSION DAMAGE RECORDED SDR RRXA99446Intercostal · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 780 TO 795 BL 12L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR INTERCOSTAL IAW DAC DWG 9753291 AND DC8 SRM 51SDR RRXA99445Intercostal · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 780 TO 795 BL 11L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR INTERCOSTAL IAW DAC DWG 9753291 AND DC8 SRM 51SDR UPS98826500Fitting · corrodedINSPECTION TYPE:D, RT AFT SERVICE DOOR F/S 1600 AT CUSP AREA THE FRAME TO CUSP ATTACH ANGLE IS HEAVILY CORRODED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR RRXA99459Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BARRIER SUPPORT FITTING AT STA 80 TO 100 BL 17R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW FITTING IAW DC8 SRM 51-1-24 AND 51-3-0. (CORROSION DSDR RRXA99458Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BARRIER NET FITTING AT STA 80 TO 100 BL 14R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW FITTING IAW DC8 SRM 51-1-21H AND 51-3-0. (CORROSION DAMASDR RRXA99457Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BARRIER NET FITTING AT STA 80 TO 100 BL 12R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW FITTING IAW DC8 SRM 51-1-21H AND 51-3-0. (CORROSION DAMASDR RRXA99456Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BARRIER NET FITTING AT STA 80 TO 100 BL 10R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW FITTING IAW DC8 SRM 51-1-21H AND 51-3-0. (CORROSION DAMASDR UPS98826415Rib · crackedINSPECTION TYPE-C, RT WING L/E O/B SECTION AT STA XFS858.00, THE UPPER L/E RIB IS CRACKED AT THE AFT END. STOP DRILLED CRACK AND REPAIRED IAW SRM 57-2-0.SDR UPS98826468Shear Tie · crackedINSPECTION TYPE-D, SHEAR TIE FITTING AT FS 300 BETWEEN L36 AND L-35L IS CRACKED AND CORRODED. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FITTING IAW SRM 53-2- 0.
Back to Douglas DC-8-73F