SDR DHL9780150CSkin · bentAT C-CHECK, RIGHT WING AT STA 178 TO 217 WING T/E UPPER SKIN FWD OF FLAT SPOILER AREA IS BENT AND WRAPPED. CUT OUT DAMAGED AREA PER DRAWING DHL D857307051 AND INSTALLED REPAIR PARTS PER SRM 51-1-8.SDR DHL9780130CSeat Track · corrodedAT C-CHECK, EXFOLIATED CORROSION ON CABIN FLOOR PANEL STA 240 C/L. REMOVED DAMAGED SECTION OF SEAT TRACK FROM STA 230 TO 290. INSTALLED REPAIR AND SEAT TRACK PER SRM 53-2-3.SDR DHL9780118CSeat Track · wornAT C-CHECK, AT FS 280 NR 1 SEAT TRACK WORN. CUT OUT SEAT TRACK AND REINSTALLED PER SRM 53-2-0.SDR DHL9780149CFloor · corrodedAT C-CHECK, MAIN CARGO COMPT SUBFLOOR HAS CRACK BETWEEN FS 220 AND 240 AT NR 1 SEAT TRACK. CUT OUT DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-2-0.SDR UPS97823078Fitting · crackedINSPECTION TYPE:D, F/S 1140 LONG 33R END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D AND 53-1-0.SDR UPS97823053Longeron · corrodedINSPECTION TYPE:D, CORROSION FOUND AT CHORD F/S 980 LONGERON 35L AND 35R. REMOVED CORROSION, REPAIRED IAW DHC SK-894-844 (REF UPS ENRG FILE NR DC8-53-1805).SDR RRXA97094Hyd Pump · leakingABOUT 600 MILES OUT OF TOKYO, HYDRAULIC FLUID STARTED GOING DOWN, PERFORMED QRH CHECKLIST AT ABOUT HALF QUANTITY. FOUND TO BE LEAKING FROM STANDBY RUDDER PUMP. REPLACED STANDBY RUDDER PUMP, SERVICED HYDRAULIC SYSTEM, ALL CONTROLS AND HYDRAULIC SYSTEM CHECK GSDR DHL9780148CSub Floor · corrodedAT C-CHECK, UPPER CARGO COMPT SUB FLOOR HAS CORROSION BETWEEN FS 300 TO 320 AT NR 1 SEAT TRACK. CUT OUT DAMAGED SECTION OF SUBFLOOR AND FABRICATED AND INSTALLLED REPAIR DOUBLER PER SRM 53-2-0.SDR DHL9780104CBulkhead · crackedAT C-CHECK, AFT PRESSURE BULKHEAD FWD SIDE AT FS 1760 LEFT AT LONGERON 11 BETWEEN STIFFENER 5772638-53 AND -51, THERE IS A 2.00 CRACK. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER AND INSTALLED PER SRM 53-2-5.SDR UPS97823099Seat Track · corrodedINSPECTION TYPE:D, SEAT TRACK CORRODED FROM F/S 1548 TO 1560 BL 0. REMOVED, FABRICATED AND INSTALLED REPAIR PARTS FROM F/S 1530 TO 1610 IAW SRM 51-1-20D, 51-3-0, AND DC8-5320-5167C.SDR UPS97823113Floorbeam · corrodedINSPECTION TYPE:D, F/S 1580 RBL 52-0 FLOORBEAM FWD TAB WAS CORRODED BEYOND LIMITS (REF N/R 535310). REPAIRED IAW DHC SK-894-310A (REF UPS ENRG FILE NR DC8-53-1814).SDR UPS97823096Stringer · corrodedINSPECTION TYPE:D, F/S 320 TO 340 STR 35L IS CORRODED BEYOND LIMITS (REF NR 534887). REMOVED AND REPLACED LONG 35L IAW SRM 53-2-0 FIG 1 AND 51-1-29D.SDR UPS97822997Doubler · crackedINSPECTION TYPE:D, NR 3 PYLON TO LWR WING DOUBLER HAS A .75 INCH CRACK AT WING FRONT SPAR LWR CAP 18 INBD OF PYLON. STOP DRILLED CRACK, FABRICATED AND INSTALLED REPAIR PARTS IAW DHC SK-894-812 (REF UPS ENRG FILE NR DC8-57-0781).SDR UPS97822975Frame · miss drilledINSPECTION TYPE:D, FUSELAGE FRAME F/S 130 HAS NUMEROUS DOUBLE DRILLED, ENLONGATED, AND HOLES WITH SHORT E.D. (CARGO LINER ATTACH HOLES). REMOVED, FABRICATED AND INSTALLED FRAME IAW SRM 51-1-20 AND DHC SK- 894-514 (REF UPS ENRG FILE NR DC8-53-1790).SDR UPS97822970Longeron · crackedINSPECTION TYPE:D, LONG 36 BETWEEB F/S 240-260 CRACKED. REMOVED AND REPLACED LONG 36 RT SIDE HALF IAW SRM 53-2-0 FIG1F, AND 51-1-29D.SDR UPS97822846Fitting · crackedINSPECTION TYPE-D, FS 1210 RT SIDE FRAME TO CUSP FITTING IS CRACKED. REMOVED AND REPLACED FITTING PER DWG 3754918 AND SRM 51-1-20.SDR UPS97823116Doubler · corrodedINSPECTION TYPE:D, FINGER DOUBLER AT F/S 190 TO 350 LONG 31L HAS LIGHT TO HEAVY CORROSION. REMOVED, FABRICATED AND INSTALLED REPLACEMENT DOUBLER IAW SRM 51-1-21, 51-1-8, 51-1-20D.SDR UPS97823114Doubler · corrodedINSPECTION TYPE:D, FINGER DOUBLER AT F/S 350 TO 450 LONGERON 31L HAS LIGHT TO HEAVY CORROSION. REMOVED, FABRICATED AND INSTALLED REPLACEMENT DOUBLER IAW SRM 51-1-21, 53-4-1, 51-1-20, AND 51-10-2.SDR UPS97822973Door Frame · miss drilledINSPECTION TYPE:D, MAIN CARGO DOOR FRAME WEB F/S 120-130 FWD OF MCD, HAS NUMEROUS DOUBLE DRILLED HOLES ( CARGO LINER ATTACH HOLES ). REMOVED, FABRICATED AND INSTALLED WEB AT STA 120 TO 130 LT BETWEEN STR 8 TO 17 LT IAW SRM 53-4-1, AND 51-1-21.SDR UPS97822908Doubler · corrodedINSPECTION TYPE-D, INTERNAL TITANIUM DOUBLER AT FS 220 TO 260 LONG 31R TO 35L HAS HEAVY CORROSION. FABRICATED, REPLACEMENT DOUBLER PER DOUGLAS DWG 9754011.SDR UPS97822903Fitting · crackedINSPECTION TYPE-D, INTERCOSTAL END FITTING CRACKED STA 860 LONG 18L. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FITTING IAW SRM 51-1-20D AND DWG 4750420.SDR UPS97822898Doubler · crackedINSPECTION TYPE-D, RT INBD HORIZONTAL L/E INBD SECTION DOUBLER CRACKED. REMOVED FABRICATED AND INSTALLED REPLACEMENT DOUBLER IAW SRM 51-1-21 AND 55-3-1.SDR DHL9780154CSeat Track · corrodedAT C-CHECK, NR 2 SEAT TRACK CORRODED AT FS 200. REMOVED DAMAGED SECTION OF SEAT TRACK FROM STA 200 TO 310 (110.5). REMOVED DAMAGED SECTION OF SEAT TRACK PER SRM 53-2-3. INSTALLED NEW SECTION PER SRM 53-2-3.SDR DHL9780147DFloor · corrodedAT C-CHECK, SUB FLOOR IS CORRODED AT FS 160 TO 200 BETWEEN NR 1 AND NR 2 SEAT TRACK. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR DOUBLER AND INSTALLED PER SRM 53-2-0SDR UPS97822869Fitting · corrodedINSPECTION TYPE-D, FUSELAGE FRAME FITTING FS 879.375 SEVERLY CORRODED AT LONGERON 24L IN LT MLG W/W. REMOVED AND REPLACED FITTING PER SRM 53-2-0 FIG 8.SDR UPS97822823Doubler · corrodedINSPECTION TYPE-D, FINGER DOUBLER CORRODED FS 1050 TO 1115 LONGERON 21R. REMOVED, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-4-1 AND 51-1-8.SDR UPS97822900Support · corrodedINSPECTION TYPE-D, AFTER REMOVAL OF STA 140 STR 27R FLOOR SUPPORT TIE FITTING, THE FLOOR SUPPORT BEAM (P/N 3773077-510) WAS FOUND TO BE CORRODED BEYOND LIMITS PER SRM 53-2-0. FABRICATED, AND INSTALLED NEW STRUT IAW SRM 51-1-20D AND DWG 3773077.SDR DHL9780153CBrackets · wornAT C-CHECK, NR 1 CROSS SLIDE DOOR LOWER TWO AFT 'T' BOLT BRACKETS HAVE HEAVY WORN METAL NEAR PIVOT PINS NR 5 AND NR 6 'T' BOLT BRACKETS. REMOVED AND REPLACED FITTING PER SRM 51-01.SDR DHL9780146CFitting · crackedAT C-CHECK, FLAP HINGE SUPPORT FITTING RT STA 97 NR 2 BOLT HOLE O/B CRACK INDICATION. OVER SIZED BOLT HOLE .03125 PER JOB CARD 8-51-12-001.SDR DHL9780145CFitting · crackedAT C-CHECK, FLAP HINGE SUPPORT FITTING LEFT STA 219 O/B BOLT HOLE CRACK INDICATION. REMOVED FITTING, REAMED HOLES AND INSTALLED NEW FITTING PER SRM 51-3-0.SDR DHL9780158CAngle · crackedAT C-CHECK, ANGLE CRACKED AT C-2 DOORS FWD TRACK SUPPORT AT CEILING OF CARGO COMPT. REMOVED, FABRICATED AND INSTALLED NEW ANGLE PER SRM 51-1-0.SDR DHL9780156CSkin · damagedAT C-CHECK, C4 DOOR OUTER SKIN DAMAGED, HAS WORKING RIVETS. REPLACED RIVETS AND DRESSED AREA PER SRM 51-8-1.SDR DHL9780143CSupprot · crackedAT C-CHECK, ANGLE CRACKED AT C2 DOORS FWD TRACK SUPPORT AT CEILING OF CARGO COMPT FS 520. FABRICATED NEW ANGLE, REMOVED AND REPLACED PER SRM 51-1-0.SDR DHL9780137CBulkhead · crackedAT C-CHECK, IN ACCESSORY COMP SUSPECT CRACK ON PRESSURE BULKHEAD BETWEEN STR 29 AND 30. CONFIRMED CRACK BY DYE PEN. STOP DRILLED CRACK. FABRICATED REPAIR ANGLES PER EO 97042501, TREATED AND PAINTED. INSTALLED ANGLES PER EO AND SRM 51-121 AND 51-1-20D.SDR DHL9780136CStringer · crackedAT C-CHECK, FUSELAGE STA 1770 AT STR 30R DOUBLER CRACKED. REMOVED AND FABRICATED AND INSTALLED ANGLE PER SRM 51-1-1.SDR DHL9780135CPanel · delaminatedAT C-CHECK, LEFT WING UPPER SURFACE ATA XW 19. PANEL DELAMINATED. REMOVED PANEL, REPAIRED AND INSTALLED PANEL AND SEALED. INSTALLED PER SRM 51-3-0.SDR UPS97823005Floorbeam · crackedINSPECTION TYPE:D, FLOORBEAM F/S 920 CRACKED ON LOWER FLANGE IN RADIUS AT LBL 68. REF UPS N/R 534617. REPAIRED IAW DHC SK-894-617 (REF UPS ENRG FILE NR DC8-53-1806).SDR UPS97822852Fitting · corrodedINSPECTION TYPE-D, FS 1690 LONG 32L IS CORRODED, FITTING. REMOVED AND REPLACED FITTING IAW SRM 51-1-21 AND 51-1-29D.SDR DHL9780141CSupport · bentAT C-CHECK, FLOOR TRACK SUPPORT WEBBING TWISTED AND BENT BL 24R. REMOVED DAMAGED WEB FABRICATED NEW WEB AND INSTALLED PER SRM 51-1-21.SDR DHL9780140CSupport · bentAT C-CHECK, MAIN CARGO COMPT AT STA 1680 TO 1700 FLOOR TRACK SUPPORT WEBBING PREVIOUS REPAIR TWISTED AND BENT. REMOVED DAMAGED WEB, FABRICATED NEW WEB AND INSTALLED PER SRM 51-1-21.SDR DHL9780139CSkin · crackedAT C-CHECK, LOWER FUSELAGE STATION AT 879.375 FORWARD RIGHT ADF LOOP ANTENNA MOUNTING AREA WEB HAS CRACK. REPAIRED CRACK WITH FABRICATED DOUBLER PER SRM 53-2-0.SDR DHL9780138CSkin · crackedAT C-CHECK, LOWER FORWARD LEFT ADF LOOP ANTENNA MOUNTING AREA WEB HAS CRACK AT FS 879.375. STOP DRILLED CRACK, INSTALLED REPAIR DOUBLER PER SRM 53-2-0.SDR DHL9780134CFloor Panel · crackedAT C-CHECK, CRACK IN FLOOR PANEL IN MAIN ENTRY AREA AT FS 55.0 AT BL 121 HAS 3.5 CRACK. STOP DRILLED CRACK AND INSTALLED REPAIR PER SRM 53-2-0.SDR DHL9780133CFairing · crackedAT C-CHECK, LOWER FUSELAGE FAIRING RIGHT SIDE HAS TWO CRACKS. STOP DRILLED CRACKS, FABRICATED REPAIR DOUBLERS, INSTALLED DOUBLERS PER SRM 53-2-0.SDR DHL9780132CFloor · corrosionAT C-CHECK, FOUND CORROSIOIN AT CABIN SUBFLOOR ATA 200 LEFT SIDE. CUT OUT DAMAGED SECTION OF SUBFLOOR MEMBRANE AND FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-2-0.SDR DHL9780131CFloor · corrodedAT C-CHECK, FWD CARGO COMPT CABIN FLOOR AT STA 240 LT SIDE COMPLETELY BROKEN OUT. CUT OUT DAMAGED SECTION OF FLOOR AND INSTALLED REPAIR DOUBLER PER SRM 53-2-0.SDR DHL9780129CSub Floor · corrodedAT C-CHECK, FWD CARGO COMPT SUBFLOOR EXFOLIATED AT STA 280 LEFT SIDE. CUT OUT DAMAGED AREA , FABRICATED REPAIR AND INSTALLED PER SRM 53-2-0.SDR DHL9780128CSpar · crackedAT C-CHECK, FOUND .1875 HOLE AT RT X69.5 SHOWED CRACK INDICATION AT BOLT HOLE NR 1. CONFIRMED CRACK BY NDT, CUT OUT DAMAGED AREA OF SKIN TO REWORK DAMAGED SECTION, FABRICATED FILLER, TREATED AND CLEANED SPAR CAP. INSTALLED FILLER PER SRM 51-3-1 AND DOUGLAS DSDR DHL9780127CSkin · damagedAT C-CHECK, RIGHT EXHAUST GATE TRAILING EDGE HAS DAMAGE. REMOVED DAMAGED SECTION OF TRAILING EDGE AND FABRICATED AND INSTALLED PER SRM 51-1-21.SDR UPS97823070Doubler · crackedINSPECTION TYPE:D, RT L/E STUB WING AT NR 3 PYLON INTERIOR DOUBLER AND ANGLE CRACKED BETWEEN STA XS 246.5 AND 250. REMOVED AND REPLACED ANGLE SUPPORT AND DOUBLER IAW SRM 51-1-20.
Back to Douglas DC-8-73F