SDR MWEA99266Beam · crackedTHE MAIN CABIN DOOR NUMBER 1 BEAM IS CRACKED AT FORWARD END UNDER FITTING. MTC FABRICATED AND INSTALLED NEW FITTING.SDR MWEA99265Fitting · crackedTHE MAIN CABIN DOOR BEAM NUMBER 1 AFT END FITTING IS CRACKED IN HALF. MTC FABRICATED AND INSTALLED NEW END FITTING.SDR CA990603021Plate · loose(CAN) ON WALK-AROUND, FOUND SEVERAL SLICES ON SIDEWALL NR 4 TIRE. FOUND LOOSE SCREWS ON RIGHT MLG DOOR PLATE, SCREW RECOUNTERSUNK AND INSTALLED USING LOCKTIGHT.SDR AT9900479Panel · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE LEFT PYLON PANEL NR 8103 CORRODED AROUND CAMLOCKS AND BACK SIDE OF THE PANEL. MECHANICALLY REMOVED CORROSION FROM PANEL, FOUND PANEL BEYOND REPAIR. ORDERED NEW PANEL IAW DC9 SRM 51-10-3, AND 54-02 FIG 3SDR AT9900392Panel · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE RIGHT PYLON PANEL NR 8204 CORRODED AROUND CAMLOCKS AND ON THE BACK SIDE. FABRICATED, LOCATED, DRILLED, DEBURRED THREE EACH REPAIRS, PRIMED, AND INSTALLED IAW DC9 SRM 51-10-3, 51-30-2, 54-01 FIG 1, 54-30-0SDR AT9900368Fire Light · illuminatedFORWARD CARGO DETECTION LIGHT ILLUMINATED DURING CRUISE. CHECKED PER CHECKLIST, AFTER TEST MAINTENANCE CONTROL AGREED WITH CREW, VALID CARGO FIRE. FIRE TRUCKS MET AIRCRAFT, DETERMINED NO EVIDENCE OF FIRE. MAINTENANCE INSPECTED FORWARD CARGO BIN RELAY, RADARSDR AT9900440Support · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE CABIN ENTRY FLOOR SUPPORT UPPER FLANGE AT BS 196 BL 0-10L CORRODED. REMOVED, FORMED, DRILLED AND INSTALLED SUPPORT IAW DC9 SRM 51-10-4, 51-30-5, 53-11-1 FIG 13, 51-10-2 AND 51-30-2.SDR 99ZZZX2466Panel · crackedDURING POST-FLIGHT WALKAROUND, FOUND THE RT UPPER WING-TO-FUSELAGE FAIRING (SECOND FROM FORWARD) BENT BACK AT THE LEADING EDGE, AND CRACKED IN THE AFT CENTER AREA. THE FAIRING ATTACHING HARDWARE WAS STILL INSTALLED. PART REPLACED. INSPECTION OF THE AIRCRAFTSDR MWEA99272Splice · damagedTHE FORWARD CARGO COMPARTMENT AT FS 503 REQUIRES A SPLICE TO REMOVED LONGERON 30. MTC FABRICATED AND INSTALLED FRAME SPLICE.SDR MWEA99270Battery Pack · dischargedTHE LEFT COWL EMERGENCY LIGHT DID NOT STAY ILLUMINATED FOR THE 10 MINUTE TEST. MTC REMOVED AND REPLACED EMERGENCY BATTERY PACK.SDR MWEA99255Fitting · crackedTHE RIGHT WHEEL WELL FITTING IS CRACKED INBOARD OF AFT END OF THE BRAKE VALVE BRACKET. MAINTENANCE FABRICATED AND INSTALLED NEW FITTING.SDR AT9900473Subfloor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CABIN ENTRY SUBFLOOR AT BS 160 TO 200 RBL 55 CORRODED. FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 53-21-0, 51-10-3, 51-10-4 AND 51-30-1.SDR AT9900385Intercostal · crackedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND A CRACK IN INTERCOSTAL RIGHT HAND FUSELAGE AT BS 148 TO 160 (L10R) FIFTY FOUR INCHES ABOVE CUSP. ROUTED OUT CRACK AND INSTALLED GUSSET AND L ANGLE REPAIR IAW TIMCO EO NR 99-1140.SDR MWEA99268Frame · splicedTHE FORWARD CARGO COMPARTMENT AT FS 503 REQUIRES A SPLICE TO REMOVE LONGERON 30 SECTION. MTC FABRICATED AND INSTALLED FRAME SPLICE AND ANGLE.SDR AT9900369Fuel Control · defectiveNR 1 ENGINE EPR FLUCTUATES, N1 AND FUEL FLOW FOLLOW. REMOVED AND REPLACED NR 1 ENGINE FUEL CONTROL IAW MM73-20-1. OPS CHECK AND LEAK CHECK GOOD.SDR AT9900364Battery Charger · defectiveFOUND THE AFT SECTION OF THE EMERGENCY FLOOR PATH LIGHTING INOPERATIVE. REPACED BATTERY CHARGER IAW MM 33-54-0, OPS CHECKED GOOD.SDR 99ZZZX2122Fairing · crackedDURING POST FLIGHT WALK-AROUND, THE RT UPPER WING-TO-FUSELAGE FAIRING (SECOND FROM FORWARD) WAS FOUND BENT BACK AT THE LEADING EDGE, AND CRACKED IN THE AFT CENTER AREA. THE FAIRING ATTACHING HARDWARE WAS STILL INSTALLED. PART REPLACED. INSPECTION OF THE AIRCSDR MWEA99269Longeron · out of limitsLONGERON 30 AT STATION 506 IS BLENDED OUT OF LIMITS. MTC FABRICATED AND INSTALLED NEW LONGERON.SDR MWEA99261Doubler · crackedTHE RIGHT AFT NOSE GEAR DOOR HINGE CUT OUT DOUBLER PLATE IS CRACKED. MAINTENANCE FABRICATED AND INSTALLED DOUBLER REPAIR.SDR MWEA99260Doubler · crackedTHE LEFT AFT NOSE GEAR DOOR HINGE CUT OUT DOUBLER PLATE IS CRACKED. MAINTENANCE FABRICATED AND INSTALLED DOUBLER REPAIR.SDR MWEA99257Pan · crackedTHE MAIN CABIN DOOR PAN IS CRACKED AT AFT SIDE OF NR 1 BEAM. MAINTENANCE FABRICATED AND INSTALLED NEW PAN.SDR MWEA99249Slide · disengagedTHE GALLEY DOOR SLIDE FELL OFF. MTC REINSTALLED GALLEY DOOR SLIDE.SDR CALA9900472Fuse · failedL1 AND L2 DOOR EMERGENCY EXIT LIGHTS INOP. REPLACED FUSES IN BATTERY PACK IN FORWARD O/H CEILING.SDR CALA9900471Light · inoperativeTWO RED FLOOR PROX LIGHTS AT FORWARD END INOP. RELAMPED FORWARD RED EMERGENCY PROX LIGHT. SPLICED IN NEW SOCKET FOR OTHER LIGHT. OPS CHECK NORMAL.SDR MWEA99259Skin · crackedTHE RIGHT SIDE OF FUSELAGE AT STATION 110 HAS A SMALL CRACK THROUGH A FASTENER. MAINTENANCE FABRICATED AND INSTALLED DOUBLER REPAIR.SDR AT9900406Mechanism · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE LEFT NOSE STEERING FOLLOW UP DIFFERENTIAL MECHANISM ARM CORRODED. REMOVED AND REPLACED THE NOSE WHEEL STEERING FOLLOW UP DIFFERENTIAL ARM IAW DC9 MM 32-51-2 AND RIGGED CHECK GOOD IAW MM 32-50-0.SDR AT9900382Angle · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CUSP ANGLE AT R-1 DOOR JAMB CORRODED AT BS 170 TO 200. FABRICATED REPAIR PARTS, DRILLED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-3, 53-05 FIG 55, 51-30-2 AND 51-30-5.SDR AT9900365Bracket · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND SIX FLOORBOARD SUPPORT BRACKETS AT BS 160-218 BL 0-53R CORRODED ON TOP AND BOTTOM. FABRICATED SIX FLOORBOARD SUPPORT BRACKETS, TREATED, PRIMED, AND INSTALLED IAW DC9 SRM 53-01 FIG 1, 51-10-4, 51-10-2, 51-10-3, 51-SDR AT9900360Longeron · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND A LONGERON CORRODED ON THE LOWER FLANGE AT BS 757 L29R. REMOVED AND REPLACED LONGERON WITH REPAIR FITTING IAW DC9 SRM 51-10-4, 51-30-2, 53-03 FIG.24, AND 51-30-1.SDR TWAA9906404Battery Pack · dischargedTHE RT ENGINE EMERGENCY NACELLE LIGHT, OVERWING EXIT LIGHTS, AND THE AFT CABIN EXIT LIGHTS WERE INOPERATIVE. REPLACED THE NACELLE LIGHT BATTERY PACK PN B030CF00101, THE OVERWING LIGHT BATTERY PACK PN 41B004AD07G3, AND BOTH AFT CABIN EXIT BULBS PN 1315. CHECKSDR MWEA99253Blkhd Former · crackedTHE VENTRAL DOOR RIGHT CORNER IS CRACKED ON FORMER. MTC FABRICATED AND INSTALLED DOUBLERS.SDR MWEA99245Slide · low pressureTHE GALLEY DOOR SLIDE PRESSURE GAUGE IS LOW AT 2500 PSI. MAINTENANCE REMOVED AND REPLACED GALLEY DOOR SLIDE.SDR AT9900384Intercostal · crackedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND A CRACK RIGHT HAND FUSELAGE AT BS 148 TO 160 FORTY FIVE INCHES ABOVE CUSP (L13R) IN INTERCOSTAL. ROUTED OUT CRACK AND INSTALLED GUSSET AND L ANGLE REPAIR IAW TIMCO EO NR 99-1139.SDR MWEA99258Doubler · crackedTHE PASSENGER DOOR HOLD OPEN HOOK POCKET EXTERNAL DOUBLER IS CRACKED. MAINTENANCE FABRICATED AND INSTALLED DOUBLER REPAIR.SDR AT9900367Skin · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND CORROSION BULGE ON LOWER BELLY SKIN AT BS 761.5 LBL 3 AND BS 763 RBL 6. FABRICATED EXTERNAL DOUBLER AND INTERNAL FINGER DOUBLER AND INSTALLED IAW TIMCO LAKE CITY EO 99-1134.SDR AT9900361Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND CORROSION ON THE SUB FLOOR AT BS 170-200 RBL 55. CUT OUT CORRODED PORTION OF SUB FLOOR. FORMED NEW DOUBLERS, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED DOUBLER IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2, AND 53-2SDR MWEA99254Intercostal · bentTHE INTERCOSTAL IS BENT AND DAMAGED AT STATION 446 IN FORWARD CARGO COMPARTMENT. MAINTENANCE FABRICATED AND INSTALLED NEW INTERCOSTAL.SDR MWEA99252Beam · crackedTHE MAIN CABIN DOOR NUMBER ONE BEAM CRACKED AT AFT END. MTC FABRICATED AND INSTALLED DOUBLER.SDR CALA9900461Light · brokenATL - FLT 715 - EMERGENCY AISLE PATH LIGHTING STRIP IN FIRST CLASS BROKEN, WIRES EXPOSED. INSTALLED NEW SECTIO NOF TRACK AND COVER. LIGHTING OPS CHECK GOOD. (M)SDR MWEA99248Doublers · double drilledWINDOW DOUBLERS AT FS 465 503 HAVE SEVERAL DOUBLE DRILLED HOLES. MAINTENANCE FABRICATED AND INSTALLED DOUBLERS.SDR MWEA99247Longeron · dentedLONGERON 17L AT STATION 433 IS DENTED. MAINTENANCE FABRICATED AND INSTALLED FILLER AND SPLICES.SDR AT9900438Doubler · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE INTERNAL DOUBLER AT BS 580 STRINGER 30. REMOVED LEADING EDGE WING TO FUSELAGE FILLET PANELS, BLEED AIR DUCTS, END CAPS AND FRAMES FOR ACCESS. REMOVED CORRODED DOUBLER, FABRICATED DOUBLER, DRILLED, DEBURSDR AT9900333Support · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE CABIN FLOOR SUPPORT AT STA 200 TO 218 BL-0 CORRODED. REMOVED CORRODED FLOOR SUPPORT, FABRICATED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 53-11-01, 51-30-2, 51-10-4 AND 51-10-3.SDR MWEA99256Pan · crackedTHE AFT CARGO DOOR OUTER PAN IS CRACKED AT THE FORWARD LOWER STOP AREA. MAINTENANCE FABRICATED AND INSTALLED DOUBLER REPAIR.SDR MWEA99240Slide · looseTHE FORWARD ENTRANCE DOOR SLIDE PACK IS LOOSE. MTC REINSTALLED LANYARD TO FORWARD ENTRANCE DOOR SLIDE.SDR MWEA99239Girt Bar · disconnectedTHE FORWARD ENTRANCE DOOR GIRT BAR DISCONNECTED FROM SLIDE. MTC REINSTALLED LANYARD TO GIRT BAR.SDR MWEA99237Skin · dentedDENT IN FUSELAGE SKIN AT STATION 83 FORWARD OF RAT PROBE. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.SDR CALA9900462Switch · failedIAH - FLT 612 - IMMEDIATELY AFTER TAKEOFF NOTICED ELECTRICAL SMELL IN COCKPIT. SMELL WENT AWAY IN A FEW MINUTES. DURING CLIMB-OUT NOTICED LEFT IGNITION C/B TRIPPED. RESET C/B PER QRH, WOULD NOT RESET. GOT A BEEP NOISE AND SPARKS CAME OUT OF OVERHEAD PANEL SDR AT9900381Support · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND FLOORBOARD SUPPORT BRACKET AT BS 160 RBL 0 TO 52 CORRODED. FABRICATED FLOOR SUPPORT ANGLE, DEBURRED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2 AND 51-30-1.SDR AT9900366Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND CABIN FLOOR PANEL NR 5857 CORRODED UNDER FASTENERS. FABRICATED, TREATED, PRIMED, AND INSTALLED CABIN FLOOR PANEL IAW DC9 SRM 51-01 FIG 1, 53-05 FIG 1, 51-10-2, 51-10-3, 51-30-2, AND 51-30-1.
Back to Douglas DC-9-32