SDR MWEA98017Blower · failedDURING APU CONDITION CHECK GOT SMOKE IN CABIN. MTC REMOVED AND REPLACED GROUND BLOWER AND WATER SEP TEMP VALVE.SDR 9800679607Power Supply · dischargedEMERGENCY LIGHTS AT GALLEY DOOR AND ON SIDES OF FORWARD CABIN SEATS ILLUMINATED DURING FLIGHT. REPLACED POWER SUPPLY AT GALLEY DOOR, OPERATIONAL CHECK NORMAL.SDR VJ9800005Slide · low pressureGALLEY DOOR EMERGENCY SLIDE PRESSURE INDICATES LOW. REPLACED R1 DOOR SLIDE IAW MM 25-60 AND PERFORMED REQUIRED INSPECTIONS.SDR MWEA98336Skin · crackedFOUND CRACK IN FUSELAGE SKIN UNDER RT UPPER PYLON TO FUSELAGE ATTACH ANGLE AT STA 1066 BELOW LONG 15R. MTC REPAIRED WITH DOUBLER.SDR 9800579615Power Supply · inoperativeNR 2 FUEL FLOW INDICATION BECAME ERRATIC DURING TAKEOFF ROLL. THE TAKEOFF WAS ABORTED AND THE FLIGHT RETURNED TO THE GATE. MAINTENANCE PLACED THE NR 2 FUEL FLOW INDICATOR ON MEL. THE AIRCRAFT WAS RELEASED AND CONTINUED AS SCHEDULED. THE FUEL FLOW INDICATORSDR MWEA98014Slide Cover · fell offGALLEY SLIDE COVER FELL OFF. MTC REINSTALLED.SDR VJ9800004Fuel Pump · failedON DESCENT AT FL80, AIRSPEED AT 250 KTS, THROTTLES AT IDLE AND N2 AT 20 PERCENT, RT ENGINE FLAMED OUT. REPLACED NR 2 ENGINE FUEL PUMP IAW MM 73-10-1; RAN ENGINE, OPS AND LEAK CHECKED GOOD. OBSERVATIONS ARE A SHEARED SHAFT IN FUEL PUMP.SDR GTIA9800008Wire · brokenACY - FLT 119 - CABIN FLOOR LIGHTING REAR EMERGENCY EXIT ROW NEEDS FIXING. REPAIRED WIRING AT SEAT TRACK SEAT 11 IAW W/D 33-51-03. GROUND OPS CHECK OK. (M)SDR 9800689611Power Supply · dischargedFLOOR PROXIMITY EMERGENCY LIGHTS AT OVERWING EXITS ILLUMINATED DURING FLIGHT. REPLACED POWER SUPPLY AT FS 657 AND BATTERIES, OPERATIONAL CHECK NORMAL.SDR VJ9800003Slide Cover · looseON ARRIVAL AT GATE, EMERGENCY SLIDE COVER CAME AJAR WHEN MAIN PASSSENGER DOOR WAS OPENED. REINSTALLED SLIDE COVER IAW MM 25-00 AND PERFORMED REQUIRED INSPECTIONS.SDR MWEA98896Slide Cover · fell offGALLEY DOOR SLIDE FELL OFF. MAINTENANCE RESECURED SLIDE ASSEMBLY TO DOOR.SDR MWEA98013Oven · dirtyFLIGHT ATTEND TURNED OFF LT OVEN, PLASTIC MELTING ON ONE ELEMENT CAUSING SMOKE. MTC CLEANED PLASTIC FROM OVEN.SDR 9800459921Bypass Actuator · brokenDURING CLIMBOUT, A LOUD THUMP WAS EMITTED FROM NOSE WHEEL AREA FOLLOWED BY A CONTINUOUS VIBRATION. NOSE AND VIBRATION REDUCED UPON LANDING GEAR EXTENSION. AIRCRAFT RETURNED TO ORIGINATION AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE BYPASS HANDLE ASDR 9800449941Battery · dischargedDURING LINE CHECK, FOUND LEFT AND RIGHT SIDE EMERGENCY EXIT LIGHTS DIM. MAINTENANCE REPLACED BATTERIES, OPERATIONAL CHECK OK.SDR VJ9800021Plate · damagedDURING C CHECK, FOUND NR 2 SLAT REQUIRED REPLACEMENT. FABRICATED AND INSTALLED IAW DC9 SRM 57-09 FIG 10A AND AEROCORP EO 98-795.SDR MWEA98037Intercostal · corrodedDURING D-CHECK, THE INTERCOSTAL AT LONGERON 29R FS 851 TO 889 WAS FOUND CORRODED. REMOVED AND FABRICATED INTERCOSTAL IAW SRM 53-11-3, INSTALLED INTERCOSTAL IAW SRM 51-30-2.SDR MWEA98036Fitting · corrodedDURING D-CHECK, CORROSION WAS FOUND ON END CAP AT FS 996 LONGERON 28L. REMOVED, ORDERED AND INSTALLED NEW END CAP IAW SRM 51-30.SDR 9800519921Press Panel · crackedDURING L-CHECK, FOUND CRACK IN NOSE LANDING GEAR WHEEL WELL HORIZONTAL PRESSURE PANEL AT LEFT OUTBOARD VERTICAL SUPPORT FS 105. REPAIRED EA 99-153448.SDR 9800509921Press Panel · crackedDURING L-CHECK, FOUND A CRACK IN THE NOSE LANDING GEAR WHEEL WELL HORIZONTAL PRESSURE PANEL ON RIGHT SIDE AT FS 83. REPAIRED PER EA 99-153449.SDR 9800249920Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND ROW 18DEF EMERGENCY LIGHTS INOPERATIVE. REPAIRED WIRING, OPERATIONAL CHECK NORMAL.SDR VJ9800158Panel · chafedDURING C-CHECK, FOUND LT WING STA 50 ABOVE HYD GROUND SERVICE ACCESS PANEL, LOWER SKIN PANEL CHAFED THROUGH AND MISSING FASTENER. REMOVED PANEL AND REPAIRED PANEL IAW EO 98-759 AERO NR 2024 TREATED AND PRIMED IAW DC-9 SRM 51-10-3. REINSTALLED PANEL IAW DC-9 SDR MWEA98012Slide Cover · fell offGALLEY SLIDE COVER FELL OFF. MTC REPLACED.SDR CALA9800008Batteries · dischargedINSPECTION FOUND OVERHEAD EMERGENCY LIGHTS BETWEEN ROWS 18-22 INOPERATIVE. THE BATTERIES IN CHARGER WERE REPLACED AND OPERATION OF THE LIGHTS WAS RESTORED.SDR CA990203013Stator · cracked(CAN) ENGINE IN SHOP AS TIME EXPIRED. INSPECTION FOUND THE FRONT COMPRESSOR ROTOR THIRD (TO FOURTH) STAGE SPACER CRACKED. THERE WERE EIGHT CRACKS EXTENDING FROM TIE ROD SLEEVE HOLES TO INSIDE AND ONE SMALL CRACK STARTING FROM THE TIE ROD SLEEVE HOLE TO OUTSISDR MWEA98895Battery Pack · dischargedDURING C-CHECK, FOUND THE PAX ENTRY WAY AND GALLEY CEILING EMERGENCY LIGHTING DIM. MTC REPLACED THE BATTERY PACK AND BATTERIES IAW SRM 33-53-0.SDR MWEA98894Power Supply · inoperativeDURING C-CHECK, FOUND AFT ACCESSORY COMPARTMENT EMERGENCY LIGHTS ON STAIR HAND RAILS DIM. MTC REPLACED BATTERIES AND BATTERY POWER SUPPLY IAW SRM 33-53-0.SDR MWEA98893Battery Pack · dischargedDURING C-CHECK, FOUND THE RIGHT HAND NACELLE EMERGENCY LIGHT REMAINS ILLUMINATED WITH SWITCH IN OFF POSITION. MTC REPLACED EMERGENCY LIGHT BATTERY PACK ASSEMBLY.SDR TWAA9800302Tire · puncturedRDU - FLT 639 - DURING PUSHBACK, THE TOW BAR PIN BROKEN AND PUNCTURED THE RIGHT NOSE GEAR TIRE. REPAIRED TOW BAR PIN. REPLACED RIGHT NOSE TIRE AND WHEEL ASSY MFG P/N 9550267. OPS CHECK NORMAL. (M)SDR MWEA98891Skin · corrosionTHE FUSELAGE INTERNAL SKIN DOUBLER SHOWED SIGNS OF CORROSION AT STATION 945 TO 965. MTC REPAIRED IAW SRM 53-04 FIG 12B SHEET 1 PAGE 33.SDR MWEA98890Doubler · crackedDURING C-CHECK, FOUND FUSELAGE NOSE SKIN ON LEFT SIDE AT STATION 64 CRACKED. MTC REPAIRED IAW SRM 53-01 FIG 2 SHEET 3.SDR CALA9900004Control · inopTHE LT MLG UNSAFE LIGHT ILLUMINATED ON UPLATCH CHECK AFTER TAKEOFF. WHEN THE SLATS AND FLAPS WERE EXTENDED TO FIVE DEGREES AND THE AIRCRAFT WAS SLOWED TO 210 KNOTS FOR A RETURN TO IAH, THE UNSAFE LIGHT EXTINGUISHED. THE AIRCRAFT LANDED WITHOUT INCIDENT. THESDR 9800339918Power Supply · inoperativeDURING LINE CHECK, FOUND RIGHT EXTERIOR EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY, OPERATIONAL CHECK OK.SDR TWAA9800202Battery Pack · dischargedSTL - FLT 693 - DURING SCHEDULED INSPECTION, FOUND LEFT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AND POWER SUPPLY. (M)SDR 98ZZZM83Power Supply · inoperativeSTL - FLT 693 - DURING SCHEDULED INSPECTION, FOUND LEFT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AND POWER SUPPLY. (M)SDR 9800319607Power Supply · inoperativeDURING LINE CHECK, FOUND FORWARD GALLEY DOOR EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY, OPERATIONAL CHECK OK.SDR VJ9800001Power Pack · inoperativeEMERGENCY CEILING LIGHTS AT SEAT ROWS 14, 15 AND 16 ARE OUT. REPLACED BATTERY POWER SUPPLY PACK; OPS CHECKS NORMAL IAW MM 33-53-0.SDR VJ970369Link · failedDURING CLIMB-OUT FROM ATL, EXPERIENCED VIBRATION NOISE FROM WHEEL WELL AREA AFTER GEAR RETRACTION. UPON LANDING FOUND NOSE GEAR DOOR DID NOT FULLY RETRACT. INSTALLED RT DOOR LINK ASSY ON NLG DOOR IAW MM 32-22-1; OPS CHECKED NORMAL.SDR GTIA9800004Bulb · failedDTW - ONE RED FLOOR PATH LIGHT INOPERATIVE AT FORWARD EMERGENCY EXIT ROW 14. REPLACED ONE FLOOR PATH BULB ASSEMBLY. OPS CHECK GOOD IAW MM 33-50. (M)SDR VJ970368Slide · fell offPASSENGER ENTRY DOOR EMERENCY SLIDE CAME OFF. REINSTALLED PASSENGER ENTRY DOOR EMERENCY SLIDE IAW MM 25-62-0.SDR MWEA97884Fitting · crackedDURING INSPECTION, FOUND CRACK ON GALLEY DOOR BOTTOM BEAM AFT FITTING. MTC REMOVED AND REPLACED BEAM END FITTING IAW SRM 51-30-5 AND SRM 51-30-2.SDR MWEA97883Frame · crackedDURING INSPECTION, FOUND CRACK AT STATION 718 ON RT SIDE FRAME FROM AFT INBOARD TENSION BOLT HOLE. MTC REPAIRED IAW SRM 51-10-4, SRM 51-30-1, SRM 51-30-2 AND SRM 51-30-5.SDR 9724389951Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD LEFT AND RIGHT OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.SDR 9724369984Power Supply · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND TAIL CONE ESCAPE PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR VJ970367Circuit Breaker · failedAT CRUISE NUMEROUS CIRCUIT BREAKERS TRIPPED WITHIN SECONDS OF EACH OTHER. REMOVED AND REPLACED LEFT PHASE 0 C 50 AMP CIRCUIT BREAKER IAW MM 24-20.SDR 9724379921Batteries · dischargedDURING PERIODIC CHECK, FOUND FORWARD OVERWING EMERGENCY EXIT SIGN LIGHTS DIM. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.SDR VJ970366Slide · fell offPASSENGER ENTRY DOOR EMERENCY SLIDE CAME OFF. REINSTALLED PASSENGER ENTRY DOOR EMERGENCY SLIDE IAW MM 25-62-0.SDR 9724269621Control Unit · failedDURING CLIMBOUT, THE LEFT ICE PROTECTION TEMPERATURE HIGH LIGHT ILLUMINATED ONCE THE ANTI-ICE SWITCH WAS TURNED TO THE OFF POSITION. FLIGHT CREW CONSULTED WITH MAINTENEANCE CONTROL, RETURNED TO ORIGINATION AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THSDR VJ970365Cover · fell offFORWARD GALLEY DOOR EMERGENCY SLIDE COVER CAME OFF. REINSTALLED FORWARD GALLEY DOOR EMERGENCY SLIDE COVER IAW MM 25-61.SDR 9724279603Connector · looseDURING LINE CHECK, FOUND SEAT 13 EMERGENCY PATHWAY LIGHT INOPERATIVE. MAINTENANCE RESEATED CONNECTOR UNDER SEAT LEG, OPERATIONAL CHECK OK.SDR GTIA9800002Power Unit · inoperativeDTW - THE UPPER EMERGENCY FLASHLIGHT IS OUT IN AFT CABIN. REPLACED POWER UNIT IN FLASHLIGHT IN AFT CABIN. (M)
Back to Douglas DC-9-32