Douglas DC-9-32

Service difficulty reports · 12,755

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC932'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR MWEA98017Blower · failedDURING APU CONDITION CHECK GOT SMOKE IN CABIN. MTC REMOVED AND REPLACED GROUND BLOWER AND WATER SEP TEMP VALVE.Jan 12, 1998 · N205ME · Doug DC932 · Air Distribution SystemSDR 9800679607Power Supply · dischargedEMERGENCY LIGHTS AT GALLEY DOOR AND ON SIDES OF FORWARD CABIN SEATS ILLUMINATED DURING FLIGHT. REPLACED POWER SUPPLY AT GALLEY DOOR, OPERATIONAL CHECK NORMAL.Jan 12, 1998 · N607NW · Doug DC932 · Emergency LightingSDR VJ9800005Slide · low pressureGALLEY DOOR EMERGENCY SLIDE PRESSURE INDICATES LOW. REPLACED R1 DOOR SLIDE IAW MM 25-60 AND PERFORMED REQUIRED INSPECTIONS.Jan 11, 1998 · N907VJ · Doug DC932 · Escape SlideSDR MWEA98336Skin · crackedFOUND CRACK IN FUSELAGE SKIN UNDER RT UPPER PYLON TO FUSELAGE ATTACH ANGLE AT STA 1066 BELOW LONG 15R. MTC REPAIRED WITH DOUBLER.Jan 11, 1998 · N502ME · Doug DC932 · Fuselage Main, Plate/SkinSDR 9800579615Power Supply · inoperativeNR 2 FUEL FLOW INDICATION BECAME ERRATIC DURING TAKEOFF ROLL. THE TAKEOFF WAS ABORTED AND THE FLIGHT RETURNED TO THE GATE. MAINTENANCE PLACED THE NR 2 FUEL FLOW INDICATOR ON MEL. THE AIRCRAFT WAS RELEASED AND CONTINUED AS SCHEDULED. THE FUEL FLOW INDICATORJan 11, 1998 · N615NW · Doug DC932 · Fuel Flow IndicatingSDR MWEA98014Slide Cover · fell offGALLEY SLIDE COVER FELL OFF. MTC REINSTALLED.Jan 10, 1998 · N501ME · Doug DC932 · Emergency EquipmentSDR VJ9800004Fuel Pump · failedON DESCENT AT FL80, AIRSPEED AT 250 KTS, THROTTLES AT IDLE AND N2 AT 20 PERCENT, RT ENGINE FLAMED OUT. REPLACED NR 2 ENGINE FUEL PUMP IAW MM 73-10-1; RAN ENGINE, OPS AND LEAK CHECKED GOOD. OBSERVATIONS ARE A SHEARED SHAFT IN FUEL PUMP.Jan 9, 1998 · N916VV · Doug DC932 · Engine Fuel PumpSDR GTIA9800008Wire · brokenACY - FLT 119 - CABIN FLOOR LIGHTING REAR EMERGENCY EXIT ROW NEEDS FIXING. REPAIRED WIRING AT SEAT TRACK SEAT 11 IAW W/D 33-51-03. GROUND OPS CHECK OK. (M)Jan 9, 1998 · N12505 · Doug DC932 · Light System WiringSDR 9800689611Power Supply · dischargedFLOOR PROXIMITY EMERGENCY LIGHTS AT OVERWING EXITS ILLUMINATED DURING FLIGHT. REPLACED POWER SUPPLY AT FS 657 AND BATTERIES, OPERATIONAL CHECK NORMAL.Jan 9, 1998 · N611NA · Doug DC932 · Emergency LightingSDR VJ9800003Slide Cover · looseON ARRIVAL AT GATE, EMERGENCY SLIDE COVER CAME AJAR WHEN MAIN PASSSENGER DOOR WAS OPENED. REINSTALLED SLIDE COVER IAW MM 25-00 AND PERFORMED REQUIRED INSPECTIONS.Jan 8, 1998 · N924VV · Doug DC932 · Emergency EquipmentSDR MWEA98896Slide Cover · fell offGALLEY DOOR SLIDE FELL OFF. MAINTENANCE RESECURED SLIDE ASSEMBLY TO DOOR.Jan 8, 1998 · N501ME · Doug DC932 · Emergency EquipmentSDR MWEA98013Oven · dirtyFLIGHT ATTEND TURNED OFF LT OVEN, PLASTIC MELTING ON ONE ELEMENT CAUSING SMOKE. MTC CLEANED PLASTIC FROM OVEN.Jan 8, 1998 · N602ME · Doug DC932 · Buffet/GalleysSDR 9800459921Bypass Actuator · brokenDURING CLIMBOUT, A LOUD THUMP WAS EMITTED FROM NOSE WHEEL AREA FOLLOWED BY A CONTINUOUS VIBRATION. NOSE AND VIBRATION REDUCED UPON LANDING GEAR EXTENSION. AIRCRAFT RETURNED TO ORIGINATION AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE BYPASS HANDLE AJan 8, 1998 · N943N · Doug DC932 · Landing Gear Retraction/Extension SystemSDR 9800449941Battery · dischargedDURING LINE CHECK, FOUND LEFT AND RIGHT SIDE EMERGENCY EXIT LIGHTS DIM. MAINTENANCE REPLACED BATTERIES, OPERATIONAL CHECK OK.Jan 8, 1998 · N3324L · Doug DC932 · Emergency LightingSDR VJ9800021Plate · damagedDURING C CHECK, FOUND NR 2 SLAT REQUIRED REPLACEMENT. FABRICATED AND INSTALLED IAW DC9 SRM 57-09 FIG 10A AND AEROCORP EO 98-795.Jan 7, 1998 · N906VJ · Doug DC932 · Leading Edge DevicesSDR MWEA98037Intercostal · corrodedDURING D-CHECK, THE INTERCOSTAL AT LONGERON 29R FS 851 TO 889 WAS FOUND CORRODED. REMOVED AND FABRICATED INTERCOSTAL IAW SRM 53-11-3, INSTALLED INTERCOSTAL IAW SRM 51-30-2.Jan 7, 1998 · N215ME · Doug DC932 · Fuselage Miscellaneous StructureSDR MWEA98036Fitting · corrodedDURING D-CHECK, CORROSION WAS FOUND ON END CAP AT FS 996 LONGERON 28L. REMOVED, ORDERED AND INSTALLED NEW END CAP IAW SRM 51-30.Jan 7, 1998 · N215ME · Doug DC932 · Fuselage Miscellaneous StructureSDR 9800519921Press Panel · crackedDURING L-CHECK, FOUND CRACK IN NOSE LANDING GEAR WHEEL WELL HORIZONTAL PRESSURE PANEL AT LEFT OUTBOARD VERTICAL SUPPORT FS 105. REPAIRED EA 99-153448.Jan 7, 1998 · N943N · Doug DC932 · Fuselage Miscellaneous StructureSDR 9800509921Press Panel · crackedDURING L-CHECK, FOUND A CRACK IN THE NOSE LANDING GEAR WHEEL WELL HORIZONTAL PRESSURE PANEL ON RIGHT SIDE AT FS 83. REPAIRED PER EA 99-153449.Jan 7, 1998 · N943N · Doug DC932 · Fuselage Miscellaneous StructureSDR 9800249920Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND ROW 18DEF EMERGENCY LIGHTS INOPERATIVE. REPAIRED WIRING, OPERATIONAL CHECK NORMAL.Jan 7, 1998 · N942N · Doug DC932 · Light System WiringSDR VJ9800158Panel · chafedDURING C-CHECK, FOUND LT WING STA 50 ABOVE HYD GROUND SERVICE ACCESS PANEL, LOWER SKIN PANEL CHAFED THROUGH AND MISSING FASTENER. REMOVED PANEL AND REPAIRED PANEL IAW EO 98-759 AERO NR 2024 TREATED AND PRIMED IAW DC-9 SRM 51-10-3. REINSTALLED PANEL IAW DC-9 Jan 6, 1998 · N915VV · Doug DC932 · Wing, Plate/SkinSDR MWEA98012Slide Cover · fell offGALLEY SLIDE COVER FELL OFF. MTC REPLACED.Jan 6, 1998 · N302ME · Doug DC932 · Emergency EquipmentSDR CALA9800008Batteries · dischargedINSPECTION FOUND OVERHEAD EMERGENCY LIGHTS BETWEEN ROWS 18-22 INOPERATIVE. THE BATTERIES IN CHARGER WERE REPLACED AND OPERATION OF THE LIGHTS WAS RESTORED.Jan 6, 1998 · N12514 · Doug DC932 · Emergency LightingSDR CA990203013Stator · cracked(CAN) ENGINE IN SHOP AS TIME EXPIRED. INSPECTION FOUND THE FRONT COMPRESSOR ROTOR THIRD (TO FOURTH) STAGE SPACER CRACKED. THERE WERE EIGHT CRACKS EXTENDING FROM TIE ROD SLEEVE HOLES TO INSIDE AND ONE SMALL CRACK STARTING FROM THE TIE ROD SLEEVE HOLE TO OUTSIJan 6, 1998 · Doug DC932 · Turbine Engine Compressor SectionSDR MWEA98895Battery Pack · dischargedDURING C-CHECK, FOUND THE PAX ENTRY WAY AND GALLEY CEILING EMERGENCY LIGHTING DIM. MTC REPLACED THE BATTERY PACK AND BATTERIES IAW SRM 33-53-0.Jan 5, 1998 · N501ME · Doug DC932 · Emergency LightingSDR MWEA98894Power Supply · inoperativeDURING C-CHECK, FOUND AFT ACCESSORY COMPARTMENT EMERGENCY LIGHTS ON STAIR HAND RAILS DIM. MTC REPLACED BATTERIES AND BATTERY POWER SUPPLY IAW SRM 33-53-0.Jan 5, 1998 · N501ME · Doug DC932 · Emergency LightingSDR MWEA98893Battery Pack · dischargedDURING C-CHECK, FOUND THE RIGHT HAND NACELLE EMERGENCY LIGHT REMAINS ILLUMINATED WITH SWITCH IN OFF POSITION. MTC REPLACED EMERGENCY LIGHT BATTERY PACK ASSEMBLY.Jan 5, 1998 · N501ME · Doug DC932 · Emergency LightingSDR TWAA9800302Tire · puncturedRDU - FLT 639 - DURING PUSHBACK, THE TOW BAR PIN BROKEN AND PUNCTURED THE RIGHT NOSE GEAR TIRE. REPAIRED TOW BAR PIN. REPLACED RIGHT NOSE TIRE AND WHEEL ASSY MFG P/N 9550267. OPS CHECK NORMAL. (M)Jan 3, 1998 · N996Z · Doug DC932 · TireSDR MWEA98891Skin · corrosionTHE FUSELAGE INTERNAL SKIN DOUBLER SHOWED SIGNS OF CORROSION AT STATION 945 TO 965. MTC REPAIRED IAW SRM 53-04 FIG 12B SHEET 1 PAGE 33.Jan 3, 1998 · N501ME · Doug DC932 · Fuselage Main, Plate/SkinSDR MWEA98890Doubler · crackedDURING C-CHECK, FOUND FUSELAGE NOSE SKIN ON LEFT SIDE AT STATION 64 CRACKED. MTC REPAIRED IAW SRM 53-01 FIG 2 SHEET 3.Jan 3, 1998 · N501ME · Doug DC932 · Fuselage Miscellaneous StructureSDR CALA9900004Control · inopTHE LT MLG UNSAFE LIGHT ILLUMINATED ON UPLATCH CHECK AFTER TAKEOFF. WHEN THE SLATS AND FLAPS WERE EXTENDED TO FIVE DEGREES AND THE AIRCRAFT WAS SLOWED TO 210 KNOTS FOR A RETURN TO IAH, THE UNSAFE LIGHT EXTINGUISHED. THE AIRCRAFT LANDED WITHOUT INCIDENT. THEJan 3, 1998 · N14524 · Doug DC932 · Landing Gear Position and WarningSDR 9800339918Power Supply · inoperativeDURING LINE CHECK, FOUND RIGHT EXTERIOR EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY, OPERATIONAL CHECK OK.Jan 3, 1998 · N940N · Doug DC932 · Emergency LightingSDR TWAA9800202Battery Pack · dischargedSTL - FLT 693 - DURING SCHEDULED INSPECTION, FOUND LEFT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AND POWER SUPPLY. (M)Jan 2, 1998 · N998R · Doug DC932 · Emergency LightingSDR 98ZZZM83Power Supply · inoperativeSTL - FLT 693 - DURING SCHEDULED INSPECTION, FOUND LEFT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AND POWER SUPPLY. (M)Jan 2, 1998 · N998R · Doug DC932 · Emergency LightingSDR 9800319607Power Supply · inoperativeDURING LINE CHECK, FOUND FORWARD GALLEY DOOR EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY, OPERATIONAL CHECK OK.Jan 2, 1998 · N607NW · Doug DC932 · Emergency LightingSDR VJ9800001Power Pack · inoperativeEMERGENCY CEILING LIGHTS AT SEAT ROWS 14, 15 AND 16 ARE OUT. REPLACED BATTERY POWER SUPPLY PACK; OPS CHECKS NORMAL IAW MM 33-53-0.Jan 1, 1998 · N937VV · Doug DC932 · Emergency LightingSDR VJ970369Link · failedDURING CLIMB-OUT FROM ATL, EXPERIENCED VIBRATION NOISE FROM WHEEL WELL AREA AFTER GEAR RETRACTION. UPON LANDING FOUND NOSE GEAR DOOR DID NOT FULLY RETRACT. INSTALLED RT DOOR LINK ASSY ON NLG DOOR IAW MM 32-22-1; OPS CHECKED NORMAL.Dec 31, 1997 · N936VV · Doug DC932 · Landing Gear DoorsSDR GTIA9800004Bulb · failedDTW - ONE RED FLOOR PATH LIGHT INOPERATIVE AT FORWARD EMERGENCY EXIT ROW 14. REPLACED ONE FLOOR PATH BULB ASSEMBLY. OPS CHECK GOOD IAW MM 33-50. (M)Dec 30, 1997 · N12505 · Doug DC932 · Emergency LightingSDR VJ970368Slide · fell offPASSENGER ENTRY DOOR EMERENCY SLIDE CAME OFF. REINSTALLED PASSENGER ENTRY DOOR EMERENCY SLIDE IAW MM 25-62-0.Dec 29, 1997 · N924VV · Doug DC932 · Emergency EquipmentSDR MWEA97884Fitting · crackedDURING INSPECTION, FOUND CRACK ON GALLEY DOOR BOTTOM BEAM AFT FITTING. MTC REMOVED AND REPLACED BEAM END FITTING IAW SRM 51-30-5 AND SRM 51-30-2.Dec 28, 1997 · N302ME · Doug DC932 · Galley DoorsSDR MWEA97883Frame · crackedDURING INSPECTION, FOUND CRACK AT STATION 718 ON RT SIDE FRAME FROM AFT INBOARD TENSION BOLT HOLE. MTC REPAIRED IAW SRM 51-10-4, SRM 51-30-1, SRM 51-30-2 AND SRM 51-30-5.Dec 28, 1997 · N302ME · Doug DC932 · Fuselage Main, FrameSDR 9724389951Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD LEFT AND RIGHT OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.Dec 28, 1997 · N9347 · Doug DC932 · Emergency LightingSDR 9724369984Power Supply · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND TAIL CONE ESCAPE PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY, OPERATIONAL CHECK NORMAL.Dec 27, 1997 · N984US · Doug DC932 · Emergency LightingSDR VJ970367Circuit Breaker · failedAT CRUISE NUMEROUS CIRCUIT BREAKERS TRIPPED WITHIN SECONDS OF EACH OTHER. REMOVED AND REPLACED LEFT PHASE 0 C 50 AMP CIRCUIT BREAKER IAW MM 24-20.Dec 26, 1997 · N935VV · Doug DC932 · AC Power Distribution SystemSDR 9724379921Batteries · dischargedDURING PERIODIC CHECK, FOUND FORWARD OVERWING EMERGENCY EXIT SIGN LIGHTS DIM. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.Dec 26, 1997 · N943N · Doug DC932 · Emergency LightingSDR VJ970366Slide · fell offPASSENGER ENTRY DOOR EMERENCY SLIDE CAME OFF. REINSTALLED PASSENGER ENTRY DOOR EMERGENCY SLIDE IAW MM 25-62-0.Dec 25, 1997 · N946VV · Doug DC932 · Emergency EquipmentSDR 9724269621Control Unit · failedDURING CLIMBOUT, THE LEFT ICE PROTECTION TEMPERATURE HIGH LIGHT ILLUMINATED ONCE THE ANTI-ICE SWITCH WAS TURNED TO THE OFF POSITION. FLIGHT CREW CONSULTED WITH MAINTENEANCE CONTROL, RETURNED TO ORIGINATION AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THDec 25, 1997 · N621NW · Doug DC932 · Airfoil Anti/De-ice SystemSDR VJ970365Cover · fell offFORWARD GALLEY DOOR EMERGENCY SLIDE COVER CAME OFF. REINSTALLED FORWARD GALLEY DOOR EMERGENCY SLIDE COVER IAW MM 25-61.Dec 24, 1997 · N930VV · Doug DC932 · Emergency EquipmentSDR 9724279603Connector · looseDURING LINE CHECK, FOUND SEAT 13 EMERGENCY PATHWAY LIGHT INOPERATIVE. MAINTENANCE RESEATED CONNECTOR UNDER SEAT LEG, OPERATIONAL CHECK OK.Dec 24, 1997 · N603NW · Doug DC932 · Emergency LightingSDR GTIA9800002Power Unit · inoperativeDTW - THE UPPER EMERGENCY FLASHLIGHT IS OUT IN AFT CABIN. REPLACED POWER UNIT IN FLASHLIGHT IN AFT CABIN. (M)Dec 23, 1997 · N942ML · Doug DC932 · Emergency Lighting
Back to Douglas DC-9-32