SDR AT9900798Panel · disbondedFOUND RT WING TRAILING EDGE PANEL DISBONDED. REMOVED UPPER SKIN, DOUBLER, CORE AND INNER SKIN. FABRICATED REPLACEMENT UPPER SKIN, UPPER SKIN EXTERNAL DOUBLER AND INNER SKIN. CUT AND FIT HONEYCOMB REPLACEMENT CORE. ACCOMPLISHED COMPOSITE REPAIR ON PANEL IAWSDR AT9900794Support · corrodedFOUND CABIN FLOOR SUPPORT AT BS 197-256 CORRODED OUT OF LIMITS ON SUPPORT AND 2 CRACKS ON SUBFLOOR. REMOVED AND REPLACED FLOOR SUPPORT AT BS 197. FABRICATED AND INSTALLED REPAIR DOUBLER ON SUBFLOOR IAW DC9 SRM 53-20-1 AND 51-10-2.SDR AT9900781Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOORBOARD SUPPORT HAT CHANNELS BETWEEN BS 200 AND BS 218 TO BE CORRODED. REMOVED AND REPLACED HAT CHANNELS IAW DC9 SRM 51-30-02.SDR AT9900779Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORTS FROM LEFT TO RIGHT SIDE AT BS 200 AND FORWARD ENDS OF SEAT TRACKS TO HAVE CORROSION. REPLACED FLOOR SUPPORTS AND TREATED SEAT TRACKS IAW DC9 SRM 51-30-02 AND 51-10-03.SDR TWAA9914506Longeron · crackedDURING CHECK-C, MAINT FOUND A 1 INCH CRACK AT STA 1076, LONGERON 2R. SPLICED SECTION PER SRM 53-02, FIG 18.SDR TWAA9914505Longeron · crackedDURING CHECK-C, MAINT FOUND LONGERON 2L AT STA 1076 HAD A 1 INCH CRACK. SPLICED SECTION PER SRM 53-02, PAGE 18.SDR MWEA99713Pan · crackedFORWARD CARGO DOOR IS CRACKED AT FWD LOCKING CAM OUTER BEARING AREA. MTC FABRICATED AND INSTALLED DOUBLER ON CARGO DOOR INNER PAN.SDR MWEA99712Pan · chafedFORWARD CARGO DOOR OUTER PAN IS CHAFED AT TOP AFT CORNER AROUND DOOR STOP PLATE. MTC FABRICATED AND INSTALLED CARGO DOOR OUTER PAN DOUBLER.SDR MWEA99711Longeron · crackedAFT CARGO COMP STATION 800 LONGERON 30 SPLICE IS CRACKED. MTC FABRICATED AND INSTALLED NEW SPLICE AT STATION 800, LONGERON 30.SDR MWEA99710Fitting · crackedFITTING IS CRACKED AT THE AFT END BEAM NR 5 FORWARD CARGO DOOR. MTC LOCATED AND DRILLED NEW FITTINGS. NEW FITTINGS WERE INSTALLED ON BEAM NR 5.SDR MWEA99709Fairing · chafedLEFT HAND HORIZONTAL VERTICAL STAB FAIRING CHAFING AT AFT VERTICAL SKIN. MTC FABRICATED AND INSTALLED NEW DOUBLER ON VERTICAL STAB.SDR MWEA99707Skin · damagedRIGHT HAND FLAP OUTBOARD REMOVABLE TRAILING EDGE PANEL LOWER SKIN DAMAGED. MTC REMOVED AND REPLACED SKIN.SDR MWEA99706Rib · damagedRIGHT HAND TRAILING EDGE PANEL, AND RIB CAP DAMAGED ON OUTBOARD FLAP. MTC REMOVED AND REINSTALLED RIB.SDR MWEA99705Rib · damagedFIRST AND SECOND RIB OF THE RIGHT HAND WING TRAILING EDGE, INBOARD OF THE END CAP AND CHANNEL, DAMAGED. MTC REMOVED AND REPLACED FIRST AND SECOND RIB AS REQUIRED.SDR MWEA99704Bracket · crackedLEFT AND RIGHT MAIN WHEEL WELL, OUTBOARD FORWARD AREA, THE ANGLE JUST OUTBOARD F/O SKI FITTING (BOZIKICHY BRACKET) IS CRACKED. MTC FABRICATED AND INSTALLED NEW ANGLES FOR LEFT AND RIGHT WHEEL WELLS.SDR 9904409951Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND TAIL COMPARTMENT ESCAPE PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK NORMAL.SDR 2000ZZZM73Battery · dirtyDURING THE ACCOMPLISHMENT OF B-CHECK CARD 0617, REQUIRING THE OPERATIONAL TEST OF THE EMERGENCY LIGHT SYSTEM THE EMERGENCY LIGHTS IN THE FORWARD OVERHEAD CEILING PANEL FAILED TO ILLUMINATE. THIS DISCREPANCY WAS TROUBLE SHOT TO A BAD BATTERY PACK CHARGER ASSEMSDR 2000ZZZM72Lamp · failedDURING THE ACCOMPLISHMENT OF B-CHECK CARD 0617, REQUIRING THE OPERATIONAL TEST OF THE EMERGENCY FLOOR PATH LIGHTING SYSTEM THE EMERGENCY LIGHT AT SEAT POSITION 16 CDE FAILED TO ILLUMINATE. THIS DISCREPANCY WAS TROUBLE SHOT TO A BURNED OUT LAMP. THE LAMP WAS SDR 2000ZZZM71Lamp · failedDURING ACCOMPLISHMENT OF B-CHECK CARD 0617, REQUIRING THE OPERATIONAL TEST OF THE EMEREGNCY LIGHTING SYSTEM THE EMERGENCY LIGHT AT THE L1 DOOR FAILED TO ILLUMINATE. THIS DISCREPANCY WAS TROUBLE SHOT TO A BURNED OUT LAMP. THE LAMP WAS REPLACED AND OPERATIONALSDR 2000ZZZM70Lens · missingDURING THE ACCOMPLISHMENT OF B-CHECK CARD 0617, REQUIRING THE OPERATIONAL TEST AND INSPECTION OF THE EMERGENCY LIGHTS SYSTEM, THE EMERGENCY LIGHT IN THE TAIL COMPARTMENT WAS WRITTEN UP AS HAVING A MISSING LENS. THE LENS COVER WAS REPLACED. THE LIGHT ASSEMBLYSDR TWAA9917412Floorbeam · wornDURING OP 16 MAINT CHECK, FOUND AT STA 427, THE FLOORBEAM TOP CHORD WAS WORN AT LBL 0-10 IN. BLENDED OUT WEAR MARKS PER SRM 53-05, FIG 20. INSTALLED 0.025 S.S WEAR STRIP PER SRM 5305.SDR TWAA9917411Floorbeam · wornDURING OP 16 MAINT CHECK, FOUND AT STA 408, FLOORBEAM TOP CHORD WORN AT LBL 0-10 IN. BLENDED OUT WEAR MARKS PER SRM 53-05, FIG 20. INSTALLED 0.025 S/S WEAR STRIP PER SRM 53-05.SDR MWEA99717Wire · crimpedFLOOR PATH EMERGENCY LIGHTING SYSTEM INOPERATIVE LAST SECTION OF LIGHTS, ROWS 16 TO 20. MAINTENANCE FOUND WIRING CRIMPED AND SHORTING. REPAIRED WIRING.SDR AT9900790Support · corrodedFOUND CABIN FLOOR SUPPORT AT BS 229 AND LBL 14 CORRODED BEYOND LIMITS AND SUB-FLOOR SKIN CRACKED. REMOVED AND REPLACED FLOOR SUPPORT AT BS 229. FABRICATED AND INSTALLED REPAIR DOUBLER ON SUB-FLOOR IAW DC9 SRM 53-11-1, 53-01 FIG 2, 51-10-3, 51-30-2, AND 51-10SDR AT9900772Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON FLOOR SUPPORT AT BS 160 TO BS 200. REMOVED AND REPLACED FLOOR SUPPORT AT BS 160 TO BS 200 IAW DC9 SRM 53-11-01, 51-10-02, 51-10-03, 51-10-04, AND 51-30-02.SDR TWAA0000105Bulkhead · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON THE AFT PRESSURE BULKHEAD, STA 1019 LT SIDE JUST BELOW APU POWER LINE FEED THROUGH. REMOVED CORROSION PER SPM 6-80-01.SDR MWEA99703Fitting · crackedFORWARD UPPER STOP FITTING ON FORWARD CARGO DOOR IS CRACKED. MAINTENANCE INSTALLED NEW STOP FITTING.SDR MWEA99702Longeron · crackedLONGERON 3 RIGHT AT STATION 756 WAS CRACKED. MAINTENANCE FABRICATED AND INSTALLED LONGERON REPAIR SECTION.SDR MWEA99701Longeron · crackedLONGERON 4 RIGHT IS CRACKED AT STATION 756. MAINTENANCE FABRICATED AND INSTALLED LONGERON REPAIR SECTION.SDR MWEA99700Doubler · crackedVENTRAL DOOR JAMB LOWER LEFT DOOR CORNER DOUBLER HAS CRACK. MAINTENANCE FABRICATED AND INSTALLED DOUBLER.SDR MWEA99698Vane · dentedRIGHT FLAP AFT MOVEABLE VANE HAD DENT ON TOP SURFACE. MTC FABRICATED AND INSTALLED DOUBLER ON RIGHT FLAP MOVEABLE VANE.SDR MWEA99697Vane · dentedLEFT INBOARD FIXED VANE HAS A SMALL DENT APPROX 24 INCHES FROM INBOARD END. MTC FABRICATED AND INSTALLED DOUBLER ON LEFT FIXED VANE.SDR MWEA99696Vane · debondingINBOARD FIXED VANE DEBONDING UNDER OUTBOARD RUB STRIP LEFT WING. MTC FABRICATED AND INSTALLED FILLER AND DOUBLER ON LEFT FIXED VANE RUB STRIP.SDR CA991103090Indicator · failed(CAN) SHORTLY AFTER TAKEOFF, RIGHT WING FUEL GAUGE INDICATED 6200, WAS 9100 AT TAKEOFF. RIGHT FUEL QUANTITY INDICATOR REPLACED.SDR AT9900757Jamb · crackedFOUND SERVICE DOOR JAMB, LOWER AFT CORNER CRACKED .700 ALONG OUTER SKIN. FABRICATED AND INSTALLED 2 DOUBLER AND FILLERS IAW EO 09-5310-29-E1472.SDR ABXA9900745Battery · dischargedDURING PREDEPARTURE CHECK AT BNA, FOUND EMERGENCY LIGHTS INOPERATIVE. REPLACED EMERGENCY LIGHT POWER SUPPLY BATTERIES.SDR TWAA9917407Angle · crackedDURING OP 16 MAINT CHECK, FOUND FUSELAGE TO WING ATTACH ANGLE CRACKED INBD OF LE OF LT WING, STA 610. REPLACED ANGLE WITH MFG PN 5910006-43. REINSTALLED HI-LOCKS PER SRM 51-30-5. INSTALLED BOLTS, NUTS AND WASHERS PER TWA SPM 6-30-07.SDR AT9900787Hat Channel · corrodedFOUND HAT CHANNELS ON FLOOR PANEL NR 36 CORRODED AND CRACKED. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 53-21 FIG 3.SDR AT9900785Support · corrodedFOUND FORWARD FLOOR SUPPORT AT BS 200 AND RBL 24 TO RBL 42 CORRODED. REMOVED CORRODED FLOOR SUPPORT. FABRICATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 53-01 FIG 1, 51-30-3, 51-10-2 AND 53-11-1 FIG 13.SDR AT9900754Floorbeam · corrodedFOUND FLOORBEAM AT BS 996 RBL 35-RBL49 WAS CORRODED. FABRICATED FLOORBEAM AND INSTALLED IAW DC9 SRM 53-05 FIGURE 108, MM 27-20-0, 20-17-0.SDR AT9900786Angle · corrodedFOUND SUPPORT ANGLE AT BS 1039 CORRODED FROM RBL 4 TO RBL 15. REMOVED CORROSION, FABRICATED STACKED ANGLE REPAIR, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-2, 53-01 FIG 2, 51-30-2 AND 51-10-3.SDR AT9900782Panel · corrodedFOUND RT FORWARD CARGO SLANT PANEL AT BS 332-370 CORRODED OUT OF LIMITS ON UPPER SIDE AROUND FASTENER HOLES AND EDGE. REMOVED CORROSION AROUND FASTENERS AND EDGES. FABRICATED NEW SLANT PANEL. TREATED, PRIMED AND REINSTALLED IAW DC9 SRM 53-01 FIG 1, 51-10-3 SDR MWEA99714Longeron · corrodedAFT CARGO COMPARTMENT AT STATION 935, LONGERON 22, LEFT HAND HAS CORROSION AROUND FASTENERS. MTC DRILLED AND REPLACED NEW LONGERON AT STATION 935.SDR AT9900784Angle · corrodedFOUND FLOOR SUPPORT ANGLE AT BS 160 CORRODED. REMOVED CORROSION FROM FLOOR SUPPORT ANGLE. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR SUPPORT ANGLE IAW DC9 SRM 51-10-3, 51-10-2 AND 51-30-5.SDR AT9900744Floorbeam · corrodedFOUND FLOORBEAM UPPER ATTACH ANGLE HAD EXFOLIATION CORROSION AT BS 980 RBL 35-RBL 49. CUT OUT CORROSION, FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 53-05 FIGURE 20A.SDR AT9900741Skin · crackedFOUND FORWARD SERVICE DOOR JAMB LOWER AFT CORNER OF SKIN CRACKED OUT OF LIMITS. FABRICATED 2 DOUBLERS, FILLERS, TRIMMED FILLER TO FIT, BACK DRILLED AND PRIMED REPAIR AND INSTALLED IAW DC9 SRM 51-10-3, 51-10-4, AND EO 09-5310-29-E1472.SDR TWAA0000106Bulkhead · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION AROUND THE AFT PRESSURE BULKHEAD. CORROSION WAS ON THE FINGER DOUBLER ON BULKHEAD AT STA 1017, LBL 25 INCHES. REMOVED CORROSION PER SPM 6-80-01.SDR TWAA0000104Skin · gougedDURING OP 16 MAINT CHECK, FOUND A 2 INCH BY 2 1/2 INCH GOUGE AND TEAR IN THE FUSELAGE SKIN AT STA 503, LONGERON 20R. CUT OUT DAMAGED SKIN AND REPAIRED PER SRM 53-04, FIG 12B, SHEET 5.SDR GTIA9901159Wire · brokenMLB - DURING DAILY, FOUND EMERGENCY FLOOR LIGHTS INOPERATIVE. REPAIRED BROKEN WIRE AND REPLACED BULB AND LENSE AND ROW 4. OPERATION CHECK NORMAL IAW 33-53-0. (M)SDR AT9900788Support · corrodedFOUND FORWARD FLOOR SUPPORT AT BS 165-200 AND LBL 44 CORRODED. REMOVED CORRODED FLOOR SUPPORT, FABRICATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-2, 51-10-3 AND 51-30-5.
Back to Douglas DC-9-32