Gulfstream Aerospace G-IV
Service difficulty reports · 842
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'GIV' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'GIV' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2001FA0000035Rib · crackedWHILE DOING A SCHEDULE VISUAL INSPECTION OF THE WING IT WAS NOTED A CRACK WAS IN RIB WEB. THE RIB IS LOCATED NEXT TO THE LAST OUTBOARD LEFT WING. CRACK IS 7 INCH LONG ALONG THE THE BOTTOM SIDE THEN TURNS UP AT BOTH ENDS FOR 1 INCH. REMOVED AND REPLACED WITHSDR UG8AD01016Battery · failedNUMBER 2 BATTERY FAILED (DEAD). APPARENT CAUSE: GROUND SERVICE BUS WAS LEFT ENERGIZED. REPLACE NR 2 BATTERY. AIRCRAFT WAS RETURNED TO SERVICE.SDR 20010427CW006O-Ring · splitAFTER DEPLANING PASSENGERS , CREW NOTICED A FUEL LEAK AT THE RIGHT HAND ENGINE. IT WAS REPORTED AS DRAINING FROM THE COWLING. AN INSPECTOR AND MECHANIC WERE DISPATCHED AND FOUND A FAULTY ORING AT THE LOW PRESSURE FUEL FILTER BOWL. THE ORING WAS REPLACED ANDSDR 20010427CW009Pump · unserviceableHYDRAULIC PUMP CASE DRAIN FILTER SAMPLES FOR LEFT ENGINE DID NOT PASS THE PATCH TEST. REPLACED PUMP WITH SERVICEABLE UNIT, BLED AIRCRAFT SYSTEMS AND RETURNED AIRCRAFT TO SERVICE. WE WILL CONTINUE SAMPLE SYSTEM FLUID AS REQUIRED.SDR 20010503CW007Actuator · inoperativePILOT SELECTED 10 DEGREES FLAPS, FLAPS MOVED TO THE SETTING BUT HORIZONTAL STABILIZER DID NOT AGREEE WITH FLAP SETTING. PILOT SELECTED FULL FLAPS DOWN SETTING BUT FLAPS WOULD NOT MOVE. MAINTENANCE CREW FOUND THAT A/C HORZ STAB ACTUATOR WAS INOPERATIVE. ON RSDR AU001186Actuator · faulty(AUS) LT OUTBOARD FLAP JACK SCREW ACTUATOR CLUTCH WEAK PREVENTING CORRECT FLAP OPERATION.SDR 20000814SH007Valve · malfunctioned****PART DEFECT/LOCAL: TAIL EQUIP BAY-VALVE STUCK CLOSED****PILOT REPORTED UNABLE TO START LT ENGINE. NO BLEED AIR PRESSURE AVAILABLE. TROUBLESHOT SYSTEM, FOUND POWER TO ISOLATION VALVE, BUT NO MOVEMENT OF VALVE. FOUND VALVE TO BE STUCK IN CLOSED POSITION.SDR 20000721SH030Connector · shortedHYA - FLT 13236 - PON TURNING ON AUXILIARY HYDRAULIC PUMP, SEVERAL OF THE LEFT ESSENTIAL BUS CIRCUIT BREAKERS TRIPPED. TROUBLESHOOTING IS STILL IN PROGRESS, HOWEVER, A FAULT/SHORTED CANNON CONNECTOR APPPEARS, AT THIS TIME, TO BE THE PROBLEM. (X)SDR 20000620SH026Fuel Line · shearedPILOTS REPORTED RT REMOTE FUELING SHUTOFF AND FLOAT PRE-CHECK INOPERABLE. INVESTIGATION REVEALED THE PRESSURE LINE FROM THE HIGH-LEVEL PILOT VALVES TO THE TANK PRESSURE SENSING VALVE INSIDE THE WING AT RBL 90.00 SHEARED OFF AT THE FORWARD ATTACH FITTING. (X)SDR 20000609SH024Gear · wornENGINE PROBLEM FIRST ENCOUNTERED DURING RUNWAY PREPARATIONS FOR TAKEOFF WHEN THE HP ROTOR SPOOLED DOWN OF ITS OWN ACCORD. NO SERVICE PROBLEMS OF ANY DESCRIPTION HAD BEEN ENCOUNTERED. SUBSEQUENT CHECKS ON THE ENGINE REVEALED THE HP ROTOR WOULD NOT ROTATE WHENSDR 20000609SH023Shaft · wornENGINE PROBLEM FIRST ENCOUNTERED DURING RUNWAY PREPARATIONS FOR TAKEOFF WHEN THE HP ROTOR SPOOLED DOWN OF ITS OWN ACCORD. NO SERVICE PROBLEMS OF ANY DESCRIPTION HAD BEEN ENCOUNTERED. SUBSEQUENT CHECKS ON THE ENGINE REVEALED THE HP ROTOR WOULD NOT ROTATE WHENSDR AU000396Skin · damaged(AUS) AIRCRAFT EXTERNAL SKIN DAMAGED DUE TO POOR TRIMMING PROCEDURE DURING MANUFACTURE.SDR K4HA99108Warning Light · illuminatedFLT 16162 - ON FINAL APPROACH, NR 2R CABIN SMOKE DETECTOR ILLUMINATED. ON TOUCHDOWN, NR 5R ILLUMINATED. ON TAXIWAY NR 8R ILLUMINATED. EVACUATED A/C IAW COMPANY PROCEDURES, EXIT THROUGH L-1 DOOR. RAN ENGINES OPS AND LEAK CHECKED PNEUAMATIC A/C PRESSURIZATIOSDR AU000531Seal · leaking(AUS) REAR BAGGAGE DOOR SEAL LEAKING. INVESTIGATION COULD FIND NO FAULT ALTHOUGH MOISTURE WAS FOUND IN THE SEAL INFLATION SYSTEM. SUSPECT MOISTURE IN DOOR SEAL AIR SUPPLY LINES FROZE AT ALTITUDE. (X)SDR 20000501SH018Switch · failedDURING APPROACH TO KTEB, FLAPS WERE SELECTED FROM 10 DEGREES TO 20 DEGREES. UPON THIS SELECTION, THE FLAP ASSEMETRY WARNING LIGHT ILLUMINATED, AND THE FLAP''''S MOTION WAS STOPPED THROUGH THE ASSEMETRY PROTECTION CIRCUIT. LEFT KTEB - FLT 44495 - ASSEMETRY SWSDR 20000412SH005Valve · looseFLAP ACTUATION SLUGGISH WITH ENGINE RUNNING. WOULD NOT OPERATE USING AUXILIARY SYSTEM. FOUND FLAP SELECTOR VALVE INTERNAL SPOOL ACCESS CAP HAD NEVER BEEN SAFETIED (NO SAFETY WIRE MARKS ON UNIT) AND HAD BACKED OUT 3 TURNS. REPLACED SELECTOR VALVE (REPLACEMENSDR 20000328SH005Valve · looseFLAP ACTUATION SLUGGISH WITH ENGINE RUNNING. WOULD NOT OPERATE USING AUXILIARY SYSTEM. FOUND FLAP SELECTOR VALVE INTERNAL SPOOL ACCESS CAP HAD NEVER BEEN SAFETIED (NO SAFETY WIRE MARKS ON UNIT) AND HAD BACKED OUT 3 TURNS. REPLACED SELECTOR VALVE (REPLACEMENSDR 20000601SH003Battery · dischargedCREWS LEFT GROUND SERVICE BUSS ON RESULTING IN DEPLETING NR 2 MAIN ACFT BATTERY. WHEN CREWS TRIED MOVING ACFT FLAPS TO FULL UP POSITION, ACFT AUX HYD PUMP WOULD NOT OPERATE ON NR 1 MAIN BATTERY. FOUND AUX HYD PUMP MISWIRED FROM FACTORY ORIG INSTALL. REF: SDR 20000413SH049Regulator · faultyON DESCENT FROM HIGH ALTITUDE WITH AUTO-THROTTLES DISCONNECTED, THE RT ENGINE WOULD NOT DECREASE TO AN IDLE SETTING WITH THE THROTTLES PHYSICALLY IN THE HARD IDLE POSITION. ENGINE FINALLY RETARDED TO IDLE WHEN DESCENDING BELOW 10,000 FEET, SLOWING BELOW 260 KSDR 2000ZZZX410Clamp · crackedAEROQUIP VEE BAND CLAMP CRACKED STRAP BENEATH 'TEE' BOLT. CLAMP SECURED 12TH STAGE DUCT BLANKING PLATE. CRACK ALLOWED CLAMP TO FLEX THEN FAIL. CLAMP AND PLATE EXITED EXHAUST THROUGH BYPASS SECTION. DAMAGE TO BYPASS CASE OUTBOARD OF 12TH STAGE.SDR 99ZZZX4431Food Warmer · shortON CLIMB-OUT, SMOKE NOTICED COMING FROM THE FOOD WARMER. THE PROBLEM WAS DETERMINED TO BE FLUID LEAKING FROM ONE OF THE HOT PLATES ON TO THE OVEN RAILS CAUSING THE BOTTOM RAIL TO SHORT TO GROUND. SUBMITTER STATED IF THE BOTTOM OF THE OVEN WAS MADE OF A NON-CSDR 99ZZZX4326Blade · damagedSUBJECT ENGINE REMOVED FROM AIRCRAFT, NR 2 POSITION, IN APRIL, 1997, FOR A MID-LIFE AND CALENDAR REWORK IAW NMSB70-1050 REV 3 APPENDICES I & II. THE ENGINE WAS REPAIRED AT ROLLS ROYCE CANADA, MONTREAL. THE ENGINE WAS RE-INSTALLED AND COMPLETED A FURTHER 1,68SDR 99ZZZM709Channel · crackedDURING FIRST ROUTINE 72 MONTH INSPECTION ON THIS AIRCRAFT, WHEN RIGHT WING WEDGE WAS REMOVED, INSPECTION FOUND THE INBOARD SUPPORT CHANNEL, P/N 1159W20194-1XD, S/N 860100 WAS CRACKED. THIS WAS CAUSED BY IMPROPER INSTALLATION DURING AIRCRAFT PRODUCTION. THE WSDR 99ZZZX3734Selector · malfunctionedCABIN PRESSURIZATION SELECTOR. LANDING ALTITUDE TAPE FAILED. TAPE/RHEOSTAT SLIPPED INTERNALLY. TAPE DISPLAYED A DIFFERENT ALTITUDE THAN WAS BEING CONTROLLED; THERE WAS APPROX 1,000 FOOT ERROR. THIS ERROR CAUSED CABIN ALTITUDE AT LANDING TO BE APPROX 1,400 SDR 99ZZZX3714Sensor · failedINTERMITTENT IN-FLIGHT 'RUDDER KICK' AND BLEED AIR MANIFOLD TEMP SPLITS REPORTED. TROUBLESHOOTING DID NOT REVEAL ANY PROBLEMS, A PHYSICAL INSPECTION OF FAN AIR SYS TEMP PROBES REVEALED A DEFECTIVE RT SIDE ANTICIPATOR 'LAGGED' ELEMENT HOUSING.SDR 99ZZZX3642Line · chafedTHE STANDBY POWER RECTIFIER/HEAT SINK ASSY PN 1159F40669-11, LOCATED UNDER FLOORBOARD NR 19, WAS CHAFING AGAINST TOTAL TEMP PROBE LINE PN 1159AC40071-025P6. THIS WORE A HOLE IN THE LINE. THERE IS EVIDENCE OF AN AIR BLAST ON THE BLACK PAINT OF THE HEAT SINK.SDR AU990856Windshield · contaminated(AUS) MOISTURE INGRESS INTO LOWER INBOARD CORNER OF LT CAPTAIN'S WINDSHIELD.SDR 99ZZZX3735Connector · failedINTERMITTENT VHF COMMUNCATION RECEPTION DURING TAXI, TAKEOFF, AND LANDING. TROUBLESHOOTING REVEALED A 'COLD SOLDER JOINT' BETWEEN CENTER CONNECTION AND ANTENNA COAX CABLE CENTER CONDUCTOR.SDR AU990857Pipe · cracked(AUS) ACCESSORY GEARBOX DRIVE PAD DRAIN PIPE CRACKED. PIPE IS MANUFACTURED FROM STAINLESS STEEL.SDR 99ZZZX4191Selector · failedCABIN PRESSURIZATION SELECTOR. LANDING ALTITUDE TAPE FAILED. TAPE/RHEOSTAT SLIPPED INTERNALLY. TAPE DISPLAYED DIFFERENT ALT THAN WAS ACTUALLY BEING CONTROLLED; THERE WAS APPROX 1,000 FOOT ERROR. ERROR CAUSED CABIN ALT AT LANDING TO BE APPROX 1,400 FEET BELSDR 20000713SH004Engine · vibrationDURING CLIMB-OUT FROM KUGN AT 10,000 MSL, THE CREW NOTICED SUDDEN, HIGH VIBRATIONS FROM THE RIGHT ENGINE. REDUCING POWER PUT VIBRATIONS AT AN ACCEPTABLE LEVEL. ALL TROUBLESHOOTING PER THE TAY MM PROVED NEGATIVE AS TO A DEFINITIVE CAUSE OF THE VIBRATIONS. THSDR 99ZZZX3713Relay · separatedRELAY 339A1K6 (AUX AC POWER) HAD A LOOSE C1 TERMINAL POST THAT RESULTED IN THE LOSS OF THE C-PHASE DURING EXTERNAL AC POWER OPERATION. SYMPTOMS WERE LOW TRU OUTPUT VOLTAGE AND POOR BATTERY CHARGING. WHEN REMOVING THE RELAY, TEMRINAL POST B1 SEPARATED FROM THSDR 99ZZZX2417Receptacle · crackedDURING A 12-MONTH INSPECTION REQUIREMENT ON THE BRUCE LIGHTING SYSTEM, TWO LAMP ASSEMBLIES WERE FOUND TO HAVE CRACKED RECEPTACLES. P/N BB 10020-03-94 CAGE 17023. SUBMITTER BELIEVED THIS WAS CAUSED BY THE SPRING TENSION ON THE LAMP. RE: CUSTOMER BULLETIN NR SDR 99ZZZX1591Iru Shelf · damagedTHE IRU RACK IS INSTALLED WITH 3 ADJUSTABLE SCREWS/BOLTS FOR ALIGNING THE RACK. THERE ARE 2 OUTBOARD SCREWS AND ONLY 1 INBOARD. THIS INBOARD FASTENER HAS BEEN OVER-STRESSED EITHER BY MAINTENANCE CREWS ADJUSTING (OVER-TIGHTENING THIS FASTENER FOR ADJUSTMENTS),SDR CA990521053Line · leaking(CAN) DURING FLIGHT, CREW NOTICED THE GENERATOR CAME OFF-LINE TWICE, ALSO, AUTO THROTTLE KEPT DISCONNECTING UNTIL FINALLY THEY WOULD NOT RE-ENGAGE. ENGINE POWER THEN ROLLED BACK WITH HP RPM REMAINING CONSTANT. SECONDS LATER, CREW HAD AN ENGINE FIRE WARNING. SDR 99ZZZX1471Drain Mast · failedPILOT REPORTED AFT SINKS (GALLEY AND LAV) WOULD NOT DRAIN. T/S SYSTEM, FOUND DRAIN MAST NOT HEATING UP. REMOVED MAST AND INSTALLED NEW MAST OF SAME P/N, S/N 396. PERFORMED OPERATIONAL CHECK OF DRAIN MAST HEATING ELEMENT, NO DEFECTS NOTED. SINKS WERE NOT DRAISDR 99ZZZX1466Nut · looseDURING STRIP OF THIS SUB-ASSEMBLY, NOTED THERE WAS LITTLE OR NO TORQUE ON THE RETAINING NUT, ALLOWING SHAFT TO SPIN IN RELATION TO THE THRUST BEARING.SDR 2000ZZZX416Ffr · failedIN-FLIGHT, ENGINE ACCELERATION/DECELERATION FL 45,000. RIGHT ENGINE COMPRESSOR STALLED AND FLAMED OUT DURING ACCELERATION. REMOVED AND REPLACED FFR PER GULFSTREAM CMP 732032.SDR 99ZZZX813Light · inoperativeLAMP WAS INOPERATIVE. AFTER GAINING ACCESS TO LAMP, FOUND THE BRUCE LIGHT BULB 'FLUORESCENT' WAS PUSHED OUT OF ITS SOCKET DUE TO THE MELTING OF THE PLASTIC RETAINING CAP. THE P/N OF THE LAMP IS BR9800-009 DATED '96'. THIS IS A GULFSTREAM FLEET PROBLEM PER CSDR AU981494Pin · corroded(AUS) NOSE LANDING GEAR STEERING SYSTEM TORQUE LINK ATTACHMENT PIN CORRODED. PART TC: 4,550.SDR 98ZZZX4038Light · inoperativeDURING FLIGHT, NOTICED SLIGHT SMOKE AND PUNGUNT ODOR AT FORWARD RT CABIN COMING FROM LIGHT ASSY. CREW MADE UNSCHEDULED LANDING WITH PASSENGERS ONBOARD AND UNEVENTFUL LANDING. MAINTENANCE FOUND SHORTED POWER SUPPLY AND SURROUNDING WIRES ON PC BOARD. REPLACEDSDR 98ZZZX4035Lamp Holder · damagedDURING COMPLIANCE OF A GULFSTREAM CUSTOMER BULLETIN NR 98 ON BRUCE INDUSTRIES LIGHTING, FOUND THE FLUORESCENT LIGHT LAMP HOLDER BURNED AT SOCKET END DUE TO ARCING.SDR 98ZZZX3575Muffler · crackedACOUSTICAL MUFFLER DEVELOPED A CRACK DUE TO POSSIBLE EXCESSIVE VIBRATION. RECOMMENDATION TO PREVENT RECURRENCE IS TO SHOCK MOUNT THE COMPONENT.SDR 99ZZZX2630Lamp · brokenLAMP POPPED OUT OF FIXTURE. COULD CAUSE ARCING. SUBMITTER STATED SEVERAL OF THESE ASSEMBLIES HAVE BEEN REPLACED RECENTLY FOR THE SAME REASON. RETAINING CAP BREAKS DUE TO EXCESSIVE SPRING TENSION ON LAMP.SDR 98ZZZX1900Switch · damagedGULFSTREAM ISSUED CUSTOMER BULLETIN 92 WHICH ADJUSTED THE THRUST REVERSER UNLOCK SWITCHES. NO DEFECTS WERE NOTED ON S/N 1034. LATER, GAC RE-ISSUED CB 92 AMI WHICH CANCELLED CB 92. NEXT, CB 92A WAS ISSUED WHICH DID NOT FUNCTION ON S/N 1034. IT DESTROYED THSDR 98ZZZX1867Valve · failedDURING LINE OP CHECK JUST PRIOR TO DEPARTURE, CREW OBSERVED 'STEER-BY-WIRE FAIL' MESSAGE ON CASDU AND ALSO FOUND NR 1 AND NR 2 STEERING CONTROL CIRCUIT BREAKERS TRIPPED. BREAKERS WOULD NOT RESET. AIRCRAFT TAXIED BACK TO RAMP WITH DIFFERENTIAL BRAKING. MAINTSDR 98ZZZM456Fairing · crackedDURING AIRCRAFT CLEANING, THE LEFT PYLON AFT METAL FAIRING WAS FOUND TORN. THIS ITEM IS NOT IDENTIFIED IN THE GIV IPC OR THE GIV SRM. GAC IS AWARE OF THIS PROBLEM AND DOES HAVE A HAND DRAWING OF THE FAIRING. GULFSTREAM NEEDS TO ADDRESS THE PROBLEM WHEN THISSDR 98ZZZX2253Control Valve · misoverhauledPILOT REPORTED WHEN GEAR EXTENDED, ALL 3 GEARS WENT DOWN AND LOCKED THEN LOST ALL COMBINED HYDRAULIC SYSTEM FLUID. MAINTENANCE FOUND LMG DOOR CONTROL VALVE MISSING LEVER AND INTERNAL PARTS, ONLY HOUSING LEFT AND WHEEL WELL. VALVE HOUSING SENT BACK TO MANUFACSDR 98ZZZX791Hose · burnedOUTFITTER - INSTALLED WATER FILL/DRAIN LINES INCORPORATE 120 VAC HEAT ELEMENT. THREE OCCURRENCES OF THE ELEMENT BURNING HOLE IN HOSE. ONE OF THE OCCURRENCES SINGED THE INSULATION AND SOUNDPROOFING.SDR 98ZZZX731Brake Line · crackedLEFT MAIN LANDING GEAR BRAKE LINE CRACKED AT THE UPPER FITTING AT THE END OF THE PERMASWAGE CRIMP. THE LINE WAS CRACKED APPROXIMATELY ONE-HALF THE CIRCUMFERENCE. SUSPECT FROM VIBRATION. SUBMITTER STATED THE LINE NEEDS ADDITIONAL SECURING CLAMPS. CYCLES, 99
Back to Gulfstream Aerospace G-IV