Mcdonnell Douglas DC-9-51

Service difficulty reports · 4,581

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC951'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DALA1106439864Cusp Web · crackedMAIN PAX CABIN RT SIDE CUSP WEB HAS 1 EA CRACK AND ELONGATED HOLES UNDERNEATH OF OTBD SEAT TRACK AT STA 229, RBL 46. REMOVED DAMAGED CUSP WEB. FABRICATED NEW CUSP WEB IAW DWG09530019 IAW SRM 53-13-2. CUT OUT ADDITIONAL DAMAGE AT STA 237. FABRICATED AND INSJan 26, 2011 · N773NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1106419857Longeron · crackedAFT ACCESSORY COMPARTMENT AFTER REMOVAL OF FRAME AT STA 1245 FOUND 1" CRACK ON L5R AT FASTENER ATTACHMENT. CUTOUT DAMAGED SECTION OF LONGERON 18" IAW SRM 53-02, FIG18. TRIMMED TO FIT LOCATED, DRILLED, & INSTALLED NEW LONGERON SECTION & 2 EA SPLICES IAW SRM Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Main, Longeron/StringerSDR DALA1106399857Gusset · crackedMAIN PASSENGER CABIN STA 832, LBL 16 GUSSET IS CRACKED. REMOVED GUSSET IAW SRM 51-30-2. FABRICATED NEW GUSSET IAW SRM 51-10-2 & DWG 4915719 LOCATED & DRILLED GUSSET IAW SRM 51-10-4. INSTALLED GUSSET IAW SRM 51-30-5.Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1106369857Support Angle · crackedMAIN PASSENGER CABIN STA 681 TO 718, RBL 55 Z-ANGLE SUPPORT CRACKED 2EA PLACES. LOCATED AND DRILLED NEW SUPPORT IAW SRM 51-10-4 PRIMED SUPPORT IAW SRM 51-10-3.Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1106349857Floor Panel · crackedMAIN CABIN METAL SKIN FLOOR PANEL, NR32, CRACKED APPROX 1 INCH. FOUND CRACK TO BE OUT OF LIMITS IAW SRM 53-01, FIG.1. R & R FLOOR PANEL NR32 IAW SRM 51-30-3. CORRECTED.Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106329857Floor Panel · corrodedMAIN PASSENGER CABIN FLOOR PANEL NR32 FWD END OTB FLANGE HAS CORROSION FROM BS 313-389. REMOVED CORROSION .020 ORIG MAT.006, REMOVED .014, REMAINING FOUND TO BE OUT OF LIMITS. REPLACED FLOOR PANEL IAW SRM 51-30-5. CORRECTED.Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106319857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR38 HAS CORROSION ON OTBD EDGE. R & R FLOOR PANEL NR 38 IAW SRM 51-30-3. REMOVED CORROSION .020 ORIGINAL .008 REMOVED .012. REMAINING FOUND TO BE OUT OF LIMITS IAW SRM 53-01. CORRECTED.Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106309857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR46 HAS CORROSION ON OTBD EDGE. REMOVED CORROSION .020 ORIG MAT, .007 REMOVED, .013 REMAINING FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1. R & R FLOOR PANEL NR46 IAW SRM 51-30-3. CORRECTED.Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106299857Skin · crackedFUSELAGE SKIN CRACKED 2EA PLACES JUST AFT OF STA 1258 BETWEEN L3L AND L4L NDT VERIFIED AND MARKED STOP DRILLED 2EA CRACKS, FABRICATED AND INSTALLED REPAIR DOUBLER FROM .063 7075T6. ALL WORK ACCOMPLISHED IAW SRM 53-01, FIG 2, 51-60-0, FIG 1. CORRECTED.Jan 26, 2011 · N766NC · Doug DC951 · Fuselage Main, Plate/SkinSDR DALA1106289857Skin · crackedFUSELAGE SKIN CRACKED APPROX 1 INCH AT FASTENER STA 1258 AT L2R NDT VERIFIED AND MARKED STOP DRILLED CRACK, FABRICATED AND INSTALLED REPAIR DOUBLER ALL WORK ACCOMPLISHED IAW SRM 53-01, FIG 2, 51-60-0 FIG 1 AND TOPPS 30-10-70. P214. REQUIRED INSPECTION COMJan 26, 2011 · N766NC · Doug DC951 · Fuselage Main, Plate/SkinSDR DALA1106279857Skin · chafedLT WING L/E SKIN AFT OF NR 2 SLAT INBD AND OTBD OF CTR TRACK CUTOUT EXISTING REPAIR IS CHAFED. REMOVED OLD REPAIR NR 2 SLAT BROKE CABLE TENSION, REMOVED NR2 SLAT PULLEY AND BRACKET FAB NEW REPAIR DOUBLER INSTALLED NR2 SLAT EXTENSION CABLE PULLEY AND BRACKET Jan 26, 2011 · N766NC · Doug DC951 · Wing, Plate/SkinSDR DALA1106269857Support Angle · crackedLT WING FLAP OTBD SIDE OF NR 4 FLAP HINGE INSIDE ACCESS PANEL 1545A SUPPORT ANGLE IS CRACKED. REMOVED CRACKED HINGE BRACKET, OBTAIN NEW BRACKET, DRILLED AND DEBURRED AND INSTALLED IAW SRM 51-30-5 & 51-30-2.Jan 26, 2011 · N766NC · Doug DC951 · Trailing Edge FlapsSDR DALA1106139857Frame · crackedAFT ACCY FRAME 1209 CRACKED AT LIGHTNING HOLE, APPROX 4 INCHES AT L12R. STOP DRILLED VERIFIED CRACK NO LONGER EXIST IAW NDT SPM 06-10-01. FABRICATED REPAIR DOUBLER, HEAT TREATED TO T6, DRILLED AND DEBURRED DOUBLER, ALODINE, PRIMED AND INSTALLED IAW SRM 53-01Jan 25, 2011 · N766NC · Doug DC951 · Fuselage Main, FrameSDR DALA1106129864Floor Panel · corrodedMAIN PASSENGER CABIN STA 148-160, FLOOR PANEL 14B HAS CORROSION. MFG FLOOR PNL NR14 IAW DWG 9957826, REV ORIGINAL AND ER/A 488341-14 REV ORIGINAL. STENCILED AND IDENTIFIED PANEL IAW PS 900-5-1, NR 04 P-117 25 JAN 11. REQUIRED INSP COMPLETED.Jan 25, 2011 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106119864Floor Panel · corrodedMAIN PASSENGER CABIN STA 148-160, FLOOR PANEL NR15 HAS CORROSION. MFG FLOOR PANEL NR15 IAW DWG 9957825, REV ORIGINAL AND ER/A 488340-14 REV ORIGINAL. STENCILED AND IDENTIFIED PANEL IAW PS900-5-1, NR 04, P-117. CORRECTED. REQUIRED INSPECTION COMPLETED.Jan 25, 2011 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106109864Floor Panel · crackedMAIN CABIN FLOOR PANEL NR105 CRACKED TOP SIDE IN FLOOR PANEL RACK. MFG FLOOR PNL NR105 IAW DWG 9915532, REV ORIGINAL AND ER/A 488724-14 REV ORIGINAL. CORRECTED. REQUIRED INSPECTION COMPLETED.Jan 25, 2011 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106099864Floor Panel · damagedMAIN CABIN FLOOR PANEL, 30 HOLES BROKE OUT AND ELONGATED IN FLOOR PANEL RACK. FABRICATED NEW NR 30 FLOOR PANEL IAW DWG 9957915. INSTALLED 5 EA HAT CHANNELS IAW SRM 51-30-7. TAGGED REPAIR IAW DPS 900-5-1 AND IAW ERA 488746-14. REQUIRED INSPECTION COMPLETED.Jan 25, 2011 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106089857Cusp Web · damagedMAIN CABIN STA 541 RT CUSP WEB HAS HOLE. REMOVED .5" DAMAGE, FABRICATED REPAIR PART. HFEC AREA FOUND CRACK FREE CONDITION IAW NDT SPM 06-10-01 INSTALLED AND PRIMED, WORK ACCOMPLISHED IAW SRM 51-13-2, FIG 4, 51-10-4, 51-10-3, DWG SG09530019. REQUIRED INSPECTJan 25, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1106079857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 37 HAS CORROSION ON OTBD EDGE. R & R FLOOR PANEL NR37 IAW SRM 51-30-1. ORIGINAL PANEL THICKNESS .020. REMOVED .005 MATERIAL, REMAINING .015 WHICH IS OUT OF LIMITS IAW SRM 53-01, FIG 1, P245. CORRECTED.Jan 25, 2011 · N766NC · Doug DC951 · Fuselage Floor PanelSDR DALA1106069864Longeron · damagedFWD CARGO COMPT STA 674, L29L BOTTOM SIDE OF TOP LEG DAMAGE. REMOVED DAMAGE FROM STA 674, L29L, ORIG MAT .080, LOSS MAT .050, REMAINING .030. FOUND TO BE OUT OF LIMITS IAW SRM 53-01. REMOVED L29 FROM STA 647 TO 698 IAW SRM 51-30-5, 51-30-2,51-30-1. INSTALLEJan 25, 2011 · N773NC · Doug DC951 · Fuselage Main, Longeron/StringerSDR DALA1106059857Frame · crackedAFT ACCY COMPARTMENT ABOVE Y-DUCT WHERE VERT STABILIZER LT ATTACH BOLT FITTING IS LOCATED, FRAME HAS 2 EACH CRACKS. REMOVED CRACKED FRAME IAW SRM 51-30-5. LOCATED, DRILLED AND INSTALLED NEW FRAME, CUSTOMER FURNISHED PART IAW SRM 51-10-4 & 51-30-5.Jan 25, 2011 · N766NC · Doug DC951 · Vertical Stabilizer, Spar/RibSDR DALA1106049857Floorbeam · crackedMAIN PASSENGER CABIN, STA 636 BETWEEN BL-0 AND LBL-22 FLOOR PANEL SUPPORT IS CRACKED. REMOVED FLOOR SUPPORT IAW SRM 51-30-2. FABRICATED NEW FROM IAW SRM 53-13-12 DRILLED, LOCATED, DEBURRED IAW SRM 51-10-4. TREATED & PRIMED IAW SRM 51-10-3, TABLE 1. INSTALLJan 25, 2011 · N766NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA1106029857Floorbeam · crackedMAIN PASSENGER CABIN STA 598 BL-0 TO LBL-22 FLOOR SUPPORT PANEL. SUPPORT IS CRACKED. REMOVED CRACKED FLOOR SUPPORT IAW SRM 51-30-2. RECEIVED METAL FOR FABRICATION OF NEW FLOORSUPPORT INSTALLED NEW FABRICATED FLOOR SUPPORT IAW SRM 51-30-2.Jan 25, 2011 · N766NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA1106019857Angle · crackedAFT ACCESSORY BETWEEN CANTED FRAME 1326 RBL-24 UPPER INTERCOSTAL SUPPORT ANGLE CRACKED APPROX 2 INCHES. REMOVED CRACKED STIFFENER IAW SRM 51-30-2 & 51-30-5. RECEIVED NEW STIFFENER LOCATED & DRILLED & DEBURRED IAW SRM 51-10-4. INSTALLED STIFFENER IAW SRM 5Jan 25, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1108789864Web · corrodedDURING M-CK, CORROSION WAS FOUND ON THE WEB AT STA 1108 BETWEEN L24R & L26R. ONCE BLENDED OUT, THE PART DAMAGE WAS OUT OF SRM LIMITS. WORK IAW ER/A 488329-14 AS FOLLOWS: SECT I, SECT II - ON OR BEFORE 3,000 CYCLES AFTER SECTION I, SECT III - WITHIN EVERY 3,0Jan 24, 2011 · N773NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105889886Structure · damagedNR3 RT WING L/E SLAT DAMAGE. REPLACED NR 3 RT WING SLAT IAW AMM 27-80-01.Jan 24, 2011 · N600TR · Doug DC951 · Leading Edge DevicesSDR DALA1105879886Structure · damagedNR 2 RT WING L/E SLAT DAMAGE. REPLACED NR 2 RT SLAT IAW 27-80-01-401 SLAT, NR 2 RT, OFF 09-2780-9-0012 00007, ON 09-2780-9-0012 00027. CORRECTED.Jan 24, 2011 · N600TR · Doug DC951 · Leading Edge DevicesSDR DALA1105849857Stiffener · crackedRT ENGINE PYLON ELECTRICAL COMPARTMENT UPPER FWD STIFFENER CRACKED ON INBD END APPROX .5 INCH. REMOVED CRACKED STIFFENER IAW SRM 51-30-2. RECEIVED MATERIAL TO FABRICATE NEW STIFFENER IAW SRM 54-10-0, SHT 1, 51-10-2. LOCATED, DRILLED, D-BURRED IAW SRM 51-10-Jan 24, 2011 · N766NC · Doug DC951 · Nacelle/Pylon Miscellaneous StructureSDR DALA1105819857Support Fitting · damagedAFT CARGO COMPT RT SIDE CARGO TIEDOWN TRACK FITTING IS BROKEN AT AFT SIDE OF FRAME STA 1136. REMOVED TIEDOWN TRACK FITTING AT STA 1136 IAW SRM 51-30-5 RECEIVED PN 5956034-503N DRILLED, DEBURRED, TREATED, & PRIMED ATTACH HOLES IAW SRM 51-10-3 & 51-10-4. INSTAJan 24, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105809857Support Fitting · crackedAFT CARGO COMPT STA 1060 RT TIE DOWN TRACK SUPPORT FITTING IS CRACKED. REMOVED ORIGINAL FITTING AND FOUND WITH 100 PERCENT MATERIAL LOSS. FABRICATED NEW FITTING LOCATED, DRILLED, DEBURRED THEN TREATED AND PRIMED INSTALLED NUTPLATE THEN FITTING WET IAW DWG 59Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105799857Structure · chafedMAIN PASSENGER CABIN STA 190, RBL 4 PREVIOUS REPAIR CHAFED. R & R REPAIR DOUBLER AT STA 190, RBL-4. ORIGINAL MATERIAL .020, 7075T6 IAW SRM 53-01, FIG 4 SHY.4 & DC9-A-53-20-03-801-66 3A-A, P106.Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105789864Floor Panel · chafedMAIN CABIN FLOOR PNL 62 FASTENER HOLES ELONGATED, CHAFED AND BROKE OUT. ORIG MATERIAL THICKNESS .025 IAW SRM 53-23-0. MATERIAL LOSS MAXIMUM .009 MATERIAL REMAINING .016 IAW SRM 53-01, FIG 1. RECEIVED MATERIAL FOR WEB AND HAT CHANNEL IAW DWG 9957919. DRILLEJan 24, 2011 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1105779857Floor Support · corrodedMAIN PASSENGER CABIN BETWEEN STA 1167-1176, RBL 18 FLOOR SUPPORT CORRODED. REMOVED FLOOR SUPPORT IAW SRM 51-30-1. REMOVED CORROSION. FROM FLOOR SUPPORT FOUND TO BE OUT OF LIMITS, FABRICATED NEW FLOOR SUPPORT IAW SRM 51-10-2. HEAT TREATED AND PRIMED IAW SRM Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105769857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR21 HAS CORROSION ON SKIN AND ON COVER PLATE. FLOOR PANEL EXFOILIATED LOSS OUT OF LIMITS IAW SRM 53-01, FIG 1. RECEIVED NEW PANEL AND DRILLUP IAW SRM 51-10-4 AND 51-10-2.Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Floor PanelSDR DALA1105759857Floorbeam · crackedMAIN PASSENGER CABIN STA 237, BL0-LBL 22 FLOOR PANEL SUPPORT IS CRACKED. REMOVED CRACKED FLOOR SUPPORT IAW SRM 51-30-2. FABRICATED NEW SUPPORT IAW SRM 51-10-2. LOCATED AND DRILLED IAW SRM 51-10-4. TREAT & PRIME IAW SRM 51-10-3. INSTALLED IAW SRM 51-30-2 & Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA1105749857Floor Support · damagedMAIN PASSENGER CABIN FWD OF STA 1100, LBL 55 FIBERGLASS FLOOR SUPPORT BROKEN OUT AT FASTENER HOLE. REMOVED FLOOR SUPPORT STA 1100, LBL 55 IAW SRM 51-30-2. RECEIVED & FABRICATED NEW FLOOR SUPPORT IAW SRM 51-10-2. RECIEVED & FABRICATED NEW BRACKET. FABRICATEDJan 24, 2011 · N766NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105739864Door Frame · corrodedFWD CARGO DOOR JAMB WEB STA 370-427 HAS CORROSION AT CORENUTS. REMOVED CORROSION ORG MAT .040. REMOVED .013, REMAINING .027 FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1. R & R WEB IAW SRM 51-30-2 AND 51-30-5. REQUIRED INSP COMPLETED.Jan 24, 2011 · N773NC · Doug DC951 · Fuselage Main, StructureSDR DALA1105709855Support · chafedAFT ACCESSORY.9910087-5 SUPPORT CHAFED. RECEIVED -5 SUPPORT. LOCATED AND DRILLED HOLES, INSTALLED -5 SUPPORT IAW SRM 51-30-5, 51-30-2 S.Jan 24, 2011 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105699855Intercostal · damagedAFT ACCESSORY INTERCOSTAL AT -27 ATTACH POINT ELONGATED HOLES, 3 EA. REMOVED DAMAGED .75"X2.5". FABBED DOUBLER FOR -3 AT -27 INTERCOSTAL IAW SRM 53-01, FIG 4 AND INSTALLED REPAIR DOUBLER SRM 51-30-2. REQUIRED INSPECTION COMPLETED.Jan 24, 2011 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1105679857Floorbeam · crackedMAIN PASSENGER CABIN, STA 1108, BETWEEN RBL 23-38 FLOOR SUPPORT CRACKED. REMOVED CRACKED FLOOR SUPPORT, STA 1108, RBL 23-38 IAW SRM 51-30-2. FABRICATED, DRILLED, DEBURRED IAW SRM 51-10-4 AND DWG 5914617. INSTALLED IAW 51-30-2 .040 7075T6 PO 1023415.Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA1105669857Window Frame · crackedMAIN PASSENGER CABIN, RT SIDE, STA 693 LOWER FWD WINDOW FRAME IS CRACKED. REMOVED DAMAGE, FABRICATED REPAIR PARTS IAW DC9-A-56-20-02-801-663A-A. HFEC AREA FOUND CRACK FREE CONDITION IAW NDT SPM 06-10-01. TREATED, PRIMED, INSTALLED & TOPCOATED IAW SRM 51-10-Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Main, StructureSDR DALA1105659857Doubler · crackedMAIN PASSENGER CABIN STA 694 LT LOWER FWD WINDOW FRAME DOUBLER IS CRACKED. REMOVED DAMAGE, FABRICATED REPAIR PARTS IAW DC9-A-56-20-02-801-663A-A. HFEC AREA FOUND CRACK FREE CONDITION IAW NDT SPM 06-10-01. TREATED, PRIMED, INSTALLED & TOPCOATED IAW SRM 51-10-Jan 24, 2011 · N766NC · Doug DC951 · Fuselage Main, Plate/SkinSDR DALA1105729857Floorbeam · damagedMAIN PASSENGER CABIN STA 813, RBL 52, FLOORBEAM ATTACH CLIP AFT SIDE HAS DRILL MARK DAMAGE. REMOVED ATTACH CLIP AFT SIDE OF STA 813, RBL 52 IAW SRM 51-30-2, 51-30-1. FABRICATED, LOCATED, DRILLED AND DEBURRED ATTACH CLIP IAW SRM 51-10-4. INSTALLED ATTACH CLIPJan 23, 2011 · N766NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA1105719857Floorbeam · damagedMAIN PASSENGER CABIN STA 813, RBL 52, FLOORBEAM ATTACH CLIP FWD SIDE HAS DRILL MARK DAMAGE. REMOVED ATTACH CLIP FORWARD SIDE OF STA 813, RBL 52 IAW SRM 51-30-2, 51-30-1. FABRICATED, DRILLED, LOCATED AND DEBURRED ATTACH CLIP IAW SRM 51-10-4. INSTALLED ATTACH Jan 23, 2011 · N766NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA1105479864Attach Angle · crackedNR 2 ENG PYLON FWD LOWER ATTACH ANGLE FOR PANEL 8220NW HAS APPROX 1 IN CRACK AT FWD END. REMOVED & FABRICATED NEW ANGLE IAW SRM 54-04, FIG 10 PRIMED IAW SRM 51-10-3 INSTALLED IAW SRM 51-30-5 & 54-04 FIG 10 & 51-30-2. REQUIRED INSP COMPLETED.Jan 23, 2011 · N773NC · Doug DC951 · Nacelle/Pylon, Attach FittingsSDR DALA1105469864Skin · damagedFWD CARGO BS 522-541, L24R, FUSELAGE SKIN HAS 3EA FASTENER HOLES KNIFE EDGED. CUT SECTION OUT FOR SKIN REPAIR STA 516-550. RT STATIC PORT IAW SRM 53-04, FIG 12C FABRICATED NEW SECTION, TREATED & PRIMED IAW SRM 53-04 FIG.12C, 51-10-3 FABRICATED FINGER DOUBLER Jan 23, 2011 · N773NC · Doug DC951 · Fuselage Main, Plate/SkinSDR DALA1105309862Slide · dislodgedTHE SLIDE PACK AT DOOR 1L FELL OUT OF BUSTLE DURING TAKEOFF. MX IN MSP REINSTALLED AND SECURED THE SLIDE.Jan 23, 2011 · N771NC · Doug DC951 · Escape SlideSDR DALA1105049864Web · corrodedAFT CARGO STA 1106 TO 1116 BETWEEN L24R AND L26R WEB HAS CORROSION. REPAIRED WEB IAW ERA 488337-14 WEIGHT OF DOUBLER IAW 30-10-7 IS 63 GRAMS TOOL NR 9513 INSTALLED & EDGE SEALED, ID TAG IAW DPS 900-5-1. CUTOUT DAMAGE 7." X 15.5 CORRECTED BY LOVE 490448.Jan 23, 2011 · N773NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1106039857Floorbeam · crackedMAIN PASSENGER CABIN STA 617, BL-0 TO LBL-22 FLOOR PANEL SUPPORT IS CRACKED. REMOVED FLOOR SUPPORT & ANGLE ATTACHED. FOUND ANGLE OUT OF LIMITS IAW SRM 51-30-2 & 53-01, FIG 1. RECEIVED NEW ANGLE AND MAT FOR NEW FLOOR SUPPORT. FABRICATED, DRILLED, DEBURRED ANJan 22, 2011 · N766NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA1105489855Wedge · crackedINCOMING RUDDER HAS A 2" CRACK UPPERMOST T/E WEDGE. CUTOUT DAMAGED SECTION 10" FABRICATED LOCATED DRILLED & INSTALLED T/E SECTION. CUSTOMER FURNISHED & SPLICE IAW SRM 53-03, FIG 6, P205. REQUIRED INSPECTION COMPLETED.Jan 22, 2011 · N764NC · Doug DC951 · Fuselage Main, Attach Fittings
Back to Mcdonnell Douglas DC-9-51