NTSB investigations
118 cases where the defining event was Electrical system malf/failure.
Cases, newest first
Query with SQL
duckdb -csv -c "SELECT c.\"ntsbNumber\", c.\"eventDate\", c.\"eventType\", c.\"eventCity\", c.\"eventStateOrRegion\", a.n_number, a.\"aircraftMake\", a.\"aircraftModel\", c.\"highestInjuryLevel\", c.\"totalFatal\", c.\"completionStatus\", c.report_url FROM 'https://openairdocs.org/data/latest/ntsb_case_detail.parquet' c LEFT JOIN 'https://openairdocs.org/data/latest/ntsb_aircrafts.parquet' a ON a.case_mkey = c.\"mKey\" AND a.position = 1 WHERE c.\"mKey\" IN (SELECT e.case_mkey FROM 'https://openairdocs.org/data/latest/ntsb_events.parquet' e WHERE e.\"isDefiningEvent\" AND e.\"tier2Number\" = '332') ORDER BY c.\"eventDate\" DESC, c.\"ntsbNumber\" DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT c."ntsbNumber", c."eventDate", c."eventType", c."eventCity", c."eventStateOrRegion", a.n_number, a."aircraftMake", a."aircraftModel", c."highestInjuryLevel", c."totalFatal", c."completionStatus", c.report_url FROM 'https://openairdocs.org/data/latest/ntsb_case_detail.parquet' c LEFT JOIN 'https://openairdocs.org/data/latest/ntsb_aircrafts.parquet' a ON a.case_mkey = c."mKey" AND a.position = 1 WHERE c."mKey" IN (SELECT e.case_mkey FROM 'https://openairdocs.org/data/latest/ntsb_events.parquet' e WHERE e."isDefiningEvent" AND e."tier2Number" = '332') ORDER BY c."eventDate" DESC, c."ntsbNumber" DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
NTSB WPR11LA378Accident · No injuriesLimited investigationFinal reportCessna 210L · Seattle, WAA loss of electrical power while on final approach due to a depleted battery, which resulted in an intentional gear-up emergency landing.NTSB DCA11IA040Incident · No injuriesIncident investigationFinal reportAirbus A320 · New Orleans, LAthe captain's failure to properly recognize and manage the abnormal condition, resulting in it escalating to an in-flight emergency.NTSB CEN11WA159Incident · Minor injuriesForeign investigationBeech B200 · Montpellier, FranceThe accident investigation is under the jurisdiction and control of the French government. This report is for informational purposes only and contains only information released by or obtained from the French government or Bureau d’Enquêtes et d’Analyses.…NTSB WPR10LA432Accident · Minor injuriesLimited investigationFinal reportStinson JR. S · Lake Stevens, WAA total loss of engine power during cruise flight, which resulted from a magneto switch failure.NTSB WPR10CA215Accident · No injuriesData collectionFinal reportPZL-Swidnik PW-5 · Marana, AZThe pilot's inability to find thermal lift. Contributing to the accident was the failure of a computer that provided glide information and vertical speed instrumentation as a result of an improperly routed electrical cable that caused a short in the…NTSB DCA10WA095Incident · No injuriesForeign investigationBoeing 757 · Las Palmas, SpainOn February 17, 2010, at 1555 UTC, a Thompson Airways Boeing 757 experienced pilot and first officer airspeed indicator anomalies during climbout from Gran Canaria Airport (LPA), Las Palmas, Canary Islands, Spain. The event occurred during a period of…NTSB WPR10LA091Accident · No injuriesLimited investigationFinal reportBeech A23-24 · Camas, WAThe left magneto's broken p-lead, which led to the engine inadvertently starting while the pilot was turning the propeller by hand.NTSB ENG09IA016Incident · No injuriesIncident investigationFinal reportBoeing 767 432ER · St. Johns, CanadaIncorrect installation of a wire bundle, which contained wires for oxygen system, passenger address system and lavatory power, led to chafing of the wires on structure. The chafing eventually exposed the wire conductors and resulted in electrical arcing,…NTSB WPR09LA423Accident · Minor injuriesLimited investigationFinal reportCessna TU206G · Ballard, WAThe pilot's precautionary water landing with partially extended landing gear. Contributing to the accident was the unidentified anomaly with the airplane's electrical system, which rendered the gear position indicator system inoperative.NTSB CEN09IA057Incident · No injuriesIncident investigationFinal reportCessna T210N · Lubbock, TXAn unidentified anomaly within the airplane's electrical system. Contributing to the incident was the pilot's failure to manually extend the landing gear.NTSB CHI08IA292Incident · No injuriesIncident investigationFinal reportBoeing 757-223 · Chicago, ILThe failure of an electrical relay due to eroded contacts and the flight crew's decision to continue a flight that was operating on battery power.NTSB NYC08FA292Accident · No injuriesField investigationFinal reportSteven A. Jones Lancair IV P · Stafford, VAThe pilot's decision to install voltage regulators in the engine compartment where they were susceptible to water intrusion, which resulted in a malfunction of the standby electrical system's voltage regulator and a subsequent in-flight fire.NTSB LAX08GA239Accident · No injuriesFinal reportBeech A200 · Salt Lake CIty, UTThe failure of the landing gear motor (worn components) resulting in the partial collapse of the landing gear during landing. Contributing to the accident was the flight crew not following emergency checklist procedures to attempt a manual gear extension.NTSB DCA08MA076Accident · No injuriesClass 1 · MajorFinal reportBoeing 767 · San Francisco, CAThe design of the supplemental oxygen system hoses and the lack of positive separation between electrical wiring and electrically conductive oxygen system components. The lack of positive separation allowed a short circuit to breach a combustible oxygen hose,…NTSB CHI08CA092Accident · No injuriesData collectionFinal reportCessna 210N · Cincinnati, OHThe pilot's decision to operate the airplane with a "dead" battery contrary to guidance provided by the Pilot's Operating Handbook. An additional cause was the pilot's failure to verify that the landing gear was fully down and locked prior to landing.…NTSB DFW08CA079Accident · No injuriesData collectionFinal reportWilley Rotorway Exec 90 · Westport, OKAn unsuccessful precautionary landing due to an electrical system malfunction.NTSB DEN08LA057Accident · No injuriesLimited investigationFinal reportBeech A45 · Englewood, COThe pilot's improper decision to fly the airplane with a discharged battery, which resulted in a total electrical failure during takeoff climb. Contributing factors were the pilot's inability to verify the landing gear position, and the impact with the runway…NTSB DCA08IA033Incident · No injuriesIncident investigationFinal reportAirbus A320 · Newark, NJa fault in the airplane's AC 1 electrical bus that caused a number of other electrical busses on the aircraft to lose power.