1/0 2/0 3/0 4/0 LENGTH (LI) IS BASED ON CONDUCTOR TEMPERATURES OF 20 °C TO DETERMINE LENGTH (L2) AT HIGHER CONDUCTOR TEMPERATURE USE FORMULA WHERE T2 = ESTIMATED 12 = 25455 + 12) AMPERES NOTE CONDUCTOR TEMPERATURE °c 18 16 WIRE SIZE VOLTAGE DROP CHART CONTINUOUS FLOW AT 20° TIN-PLATED MIL-W-27759 CONDUCTOR EXAMPLE # 1 EXAMPLE # 2 NO. 8 WIRE AT 20 AMPS NO. 12 WIRE AT 20 AMPS NO. 14 WIRE AT 20 AMPS CONTINUOUS CIRCUTI VOLTAGE 150 20 - 0.5 VOLTAGE DROP 200 115 24 20 FIGURE 11-2. Conductor chart, continuous flow.
Page 11-30 Par 11-69
AMPERES = 2 1 1/0 2/0 3/0 4/0 NOTE LENGTH (LI) IS BASED ON CONDUCTOR TEMPERATURES OF 20° C TO DETERMINE LENGTH (L2) AT HIGHER CONDUCTOR TEMPERATURE USE FORMULA WHERE T2 = ESTIMATED CONDUCTOR TEMPERATURE °C (254.5) (L1) (234.5) + (T2) WIRE SIZE VOLTAGE DROP CHART INTERMITTENT FLOW AT 20° TIN-PLATED MIL-W-27759 CONDUCTOR CIRCUIT VOLTAGE 115 28 10 ~ VOLTAGE DROP 320 240 200 00 420 350
WIRE LENGTH IN FEET FIGURE 11-3. Conductor chart, intermittent flow.
Par 11-69 Page 11-31
90100 20 CURRENT AMPERES
WIRE SIZE A NOT TO BE USED AS SINGLE WIRE 300 (WIRE RATING MINUS THE AMBIENT = T IN C)
TEMPERATURE DIFFERENCE FIGURE 11-4a. Single copper wire in free air.
Page 11-32 Par 11-69
300 CURRENT AMPERES
• WIRE SIZE 8 70 80 90 100 (WIRE RATING MINUS THE AMBIENT = T IN C)
TEMPERATURE DIFFERENCE FIGURE 11-4b. Single copper wire in free air.
Par 11-69 Page 11-33
BUNDLE LOADING PERCENT 11 13 15 17 19 21 23 25 27 NUMBER OF WIRES IN BUNDLE
CURRENT DERATING FACTOR FIGURE 11-5. Bundle derating curves.
Page 11-34 Par 11-69
50 30 ALTITUDE (x 1,000 feet)
• • 0.70 FIGURE 11-6. Altitude derating curve.
11-70. - 11-75. [RESERVED.] Par 11-69 Page 11-34a (and 11-34b)
SECTION 6. AIRCRAFT ELECTRICAL WIRE SELECTION
11-76. GENERAL. Aircraft service im poses severe environmental condition on elec trical wire. To ensure satisfactory service, in spect wire annually for abrasions, defective in sulation, condition of terminations, and poten tial corrosion. Grounding connections for power, distribution equipment, and electro magnetic shielding must be given particular attention to ensure that electrical bonding re sistance has not been significantly increased by the loosening of connections or corrosion.
a. Wire Size. Wires must have sufficient mechanical strength to allow for service con ditions. Do not exceed allowable voltage drop levels. Ensure that the wires are protected by system circuit protection devices, and that they meet circuit current carrying requirements. If it is desirable to use wire sizes smaller than #20, particular attention should be given to the mechanical strength and installation handling of these wires, e.g. vibration, flexing, and termination. When used in interconnect ing airframe application, #24 gauge wire must be made of high strength alloy.
b. Installation Precautions for Small Wires. As a general practice, wires smaller than size #20 must be provided with additional clamps, grouped with at least three other wires, and have additional support at terminations, such as connector grommets, strain-relief clamps, shrinkable sleeving, or telescoping bushings. They should not be used in applica tions where they will be subjected to excessive vibration, repeated bending, or frequent dis connection from screw terminations.
c. Identification. All wire used on air craft must have its type identification im printed along its length. It is common practice to follow this part number with the five digit/letter Commercial and Government En tity (C.A.G .E). code identifying the wire manufacturer. Existing installed wire that needs replacement can thereby be identified as to its performance capabilities, and the inad vertent use of a lower performance and unsuit able replacement wire avoided.
(1) In addition to the type identification imprinted by the original wire manufacturer, aircraft wire also contains its unique circuit identification coding that is put on at the time of harness assembly. The traditional “Hot Stamp” method has not been totally satisfac tory in recent years when used on modern, ul tra-thin-walled installations. Fracture of the insulation wall and penetration to the conduc tor of these materials by the stamping dies have occurred. Later in service, when these openings have been wetted by various fluids, serious arcing and surface tracking have dam aged wire bundles.
(2) Extreme care must be taken during circuit identification by a hot stamp machine on wire with a 10 mil wall or thinner. Alter native identification methods, such as “Laser Printing” and “Ink Jet,” are coming into in creasing use by the industry. When such mod ern equipment is not available, the use of stamped identification sleeving should be con sidered on thin-walled wire, especially when insulation wall thickness falls below 10 mils.
11-77. AIRCRAFT WIRE MATERIALS.
Only wire, specifically designed for airborne use, must be installed in aircraft.
a. Authentic Aircraft Wire. Most air craft wire designs are to specifications that re quire manufacturers to pass rigorous testing of wires before being added to a Qualified Prod ucts List (QPL) and being permitted to produce the wire. Aircraft manufacturers who maintain their own wire specifications invariably exer cise close control on their approved Par 11-78 Page 11-35
sources. Such military or original equipment manufacturer (OEM) wire used on aircraft should only have originated from these defined wire mills. Aircraft wire from other unau thorized firms, and fraudulently marked with the specified identification, must be regarded as “unapproved wire,” and usually will be of inferior quality with little or no process control testing. Efforts must be taken to ensure ob taining authentic, fully tested aircraft wire.
b. Plating . Bare copper develops a sur face oxide coating at a rate dependent on tem perature. This oxide film is a poor conductor of electricity and inhibits determination of wire. Therefore, all aircraft wiring has a coat ing of tin, silver, or nickel, that have far slower oxidation rates.
(1) Tin coated copper is a very common plating material. Its ability to be successfully soldered without highly active fluxes dimin ishes rapidly with time after manufacture. It can be used up to the limiting temperature of 150 °C.
(2) Silver-coated wire is used where temperatures do not exceed 200 °C (392 °F).
(3) Nickel coated wire retains its prop erties beyond 260 °C, but most aircraft wire using such coated strands have insulation sys tems that cannot exceed that temperature on long-term exposure. Soldered terminations of nickel-plated conductor require the use of dif ferent solder sleeves or flux than those used with tin or silver-plated conductor.
c. Conductor Stranding. Because of flight vibration and flexing, conductor round wire should be stranded to minimize fatigue breakage.
d. Wire Construction Versus Application. The most important consideration in the selection of aircraft wire is properly matching the wire’s construction to the application envi ronment. Wire construction that is suitable for the most severe environmental condition to be encountered should be selected. Wires are typically categorized as being suitable for ei ther “open wiring” or “protected wiring” ap plications. MIL-W-5088L, replaced by AS50881A, wiring aerospace vehicle, Appen dix A table A-I lists wires considered to have sufficient abrasion and cut-through resistance to be suitable for open-harness construction.
MIL-W-5088L, replaced by AS50881A, wiring aerospace vehicle, Appendix A table A-II lists wires for protected applications. These wires are not recommended for aircraft interconnec tion wiring unless the subject harness is cov ered throughout its length by a protective jacket. The wire temperature rating is typically a measure of the insulation’s ability to with stand the combination of ambient temperature and current related conductor temperature rise.
e. Insulation. There are many insulation materials and combinations used on aircraft electrical wire. Characteristics should be cho sen based on environment; such as abrasion re sistance, arc resistance, corrosion resistance, cut-through strength, dielectric strength, flame resistant, mechanical strength, smoke emis sion, fluid resistance, and heat distortion. An explanation of many of the abbreviations is identified in the glossary.
11-78. SUBSTITUTIONS. In the repair and modification of existing aircraft, when a replacement wire is required, the maintenance manual for that aircraft must first be reviewed to determine if the original aircraft manufac turer (OAM) has approved any substitution. If not, then the OAM must be contacted for an acceptable replacement.
a. MIL-W-5088L, replaced by AS50881A, wiring aerospace vehicle, Appendix A lists wire types that have been approved for military Page 11-36 Par 11-77
aerospace applications in open and protected wiring applications. These wires could poten tially be used for substitution when approved by the OAM.
b. Areas designated as severe wind and moisture problem (SWAMP) areas differ from aircraft to aircraft but generally are con sidered to be areas such as wheel wells, near wing flaps, wing folds, pylons, and other exte rior areas that may have a harsh environment.
Wires for these applications often have design features incorporated into their construction that may make the wire unique; therefore an acceptable substitution may be difficult, if not impossible, to find. It is very important to use the wire type recommended in the aircraft manufacturer’s maintenance handbook.
c. The use of current military specification, multi-conductor cables in place of OEM installed constructions may create problems such as color sequence. Some civil ian aircraft are wired with the older color se quence employing “Red-Blue-Yellow” as the first three colors. Current military specifica tion, multi-conductor cables, in accordance with MIL-C-27500, use “White-Blue-Orange” for the initial three colors. Use of an alterna tive color code during modification without adequate notation on wiring diagrams could severely complicate subsequent servicing of the aircraft. At the time of this writing, MIL-C-27500 is being revised to include the older color sequence and could eliminate this problem in the future.
11-79. 11-84. [RESERVED.] Table 11-2b. Comparable properties of wire insulation systems.
Most desirable �� �� Least Relative Ranking 1 2 3 4 Weight PI ETFE COMP PTFE Temperature PTFE COMP PI ETFE Abrasion resistance PI ETFE COMP PTFE Cut-through resistance PI COMP ETFE PTFE Chemical resistance PTFE ETFE COMP PI Flammability PTFE COMP PI ETFE Smoke generation PI COMP PTFE ETFE Flexibility PTFE ETFE COMP PI Creep (at temperature) PI COMP PTFE ETFE Arc propagation resistance PTFE ETFE COMP PI Par 11-78 Page 11-37 (and 11-38)
SECTION 7. TABLE OF ACCEPTABLE WIRES
11-85. AIRCRAFT WIRE TABLE. Tables 11-11 and 11-12 list wires used for the transmission of signal and power currents in aircraft. It does not include special purpose wires such as thermocouple, engine vibration monitor wire, fiber optics, data bus, and other such wire designs. Fire resistant wire is included because it is experiencing a wider application in aircraft circuits beyond that of the fire detection systems.
a. All wires in tables 11-11 and 11-12 have been determined to meet the flammability requirements of Title 14 of the Code of Federal Regulation (14 CFR) part 25, section
25.869(a)(4) and the applicable portion of part 1 of Appendix F of part 25.
b. The absence of any wire from ta - bles 11-11 and 11-12 are not to be construed as being unacceptable for use in aircraft. However, the listed wires have all been reviewed for such use and have been found suitable, or have a successful history of such usage.
c. Explanations of the various insulation materials mentioned in table 11-11, by abbreviations, can be found in the glossary.
11-86. OPEN AIRFRAME INTERCON- NECTING WIRE. Interconnecting wire is used in point to point open harnesses, normally in the interior or pressurized fuselage, with each wire providing enough insulation to resist damage from handling and service exposure.
(See table 11-11.) Electrical wiring is often installed in aircraft without special enclosing means. This practice is known as open wiring and offers the advantages of ease of maintenance and reduced weight.
11-87. PROTECTED WIRE. Airborne wire that is used within equipment boxes, or has additional protection, such as an exterior jacket, conduit, tray, or other covering is known as protected wire. (See table 11-12.)
11-88. SEVERE WIND AND MOISTURE PROBLEMS (SWAMP). Areas such as wheel wells, wing fold and pylons, flap areas, and those areas exposed to extended weather shall dictate selection and will require special consideration. Insulation or jacketing will vary according to the environment. Suitable wire types selected from MIL-W-22759 shall be used in these applications. (See table 11-11.)
Suitable wire types selected from MIL-W-22759 are preferred for areas that require repeated bending and flexing of the wire.
Consideration should be made to areas that require frequent component removal or repair.
(See table 11-11.)
11-89. SHIELDED WIRE. With the increase in number of highly sensitive electronic devices found on modern aircraft, it has become very important to ensure proper shielding for many electric circuits. Shielding is the process of applying a metallic covering to wiring and equipment to eliminate interference caused by stray electromagnetic energy.
Shielded wire or cable is typically connected to the aircraft’s ground at both ends of the wire, or at connectors in the cable. Electromagnetic Interference (EMI) is caused when electromagnetic fields (radio waves) induce highfrequency (HF) voltages in a wire or component. The induced voltage can cause system inaccuracies or even failure, therefore putting the aircraft and passengers at risk. Shielding helps to eliminate EMI by protecting the primary conductor with an outer conductor. Refer to MIL-DTL-27500, Cable, Power, Electrical and Cable Special Purpose, Electrical Shielded and Unshielded General Specifica - tions.
Par 11-85 Pages 11-39
TABLE 11-11. Open Wiring.
Document Voltage rating (maximum) Rated wire temperature (°C) Insulation Type Conductor type MIL-W-22759/1 600 200 Fluoropolymer insulated TFE and TFE coated glass Silver coated copper MIL-W-22759/2 600 260 Fluoropolymer insulated TFE and TFE coated glass Nickel coated copper MIL-W-22759/3 600 260 Fluoropolymer insulated TFE -glass- TFE Nickel coated copper MIL-W-22759/4 600 200 Fluoropolymer insulated TFE -glass- FEP Silver coated copper MIL-W-22759/5 600 200 Fluoropolymer insulated extruded TFE Silver coated copper MIL-W-22759/6 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper MIL-W-22759/7 600 200 Fluoropolymer insulated extruded TFE Silver coated copper MIL-W-22759/8 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper MIL-W-22759/9 1000 200 Fluoropolymer insulated extruded TFE Silver coated copper MIL-W-22759/10 1000 260 Fluoropolymer insulated extruded TFE Nickel coated copper MIL-W-22759/13 600 135 Fluoropolymer insulated FEP PVF2 Tin coated copper, MIL-W-22759/16 600 150 Fluoropolymer insulated extruded ETFE Tin coated copper, MIL-W-22759/17 600 150 Fluoropolymer insulated extruded ETFE Silver coated high strength copper alloy MIL-W-22759/20 1000 200 Fluoropolymer insulated extruded TFE Silver coated high strength copper alloy MIL-W-22759/21 1000 260 Fluoropolymer insulated extruded TFE Nickel coated high strength copper alloy MIL-W-22759/34 600 150 Fluoropolymer insulated crosslinked modified ETFE Tin coated copper MIL-W-22759/35 600 200 Fluoropolymer insulated crosslinked modified ETFE Silver coated high strength copper alloy MIL-W-22759/41 600 200 Fluoropolymer insulated crosslinked modified ETFE Nickel coated copper MIL-W-22759/42 600 200 Fluoropolymer insulated crosslinked modified ETFE Nickel coated high strength copper alloy MIL-W-22759/43 600 200 Fluoropolymer insulated crosslinked modified ETFE Silver coated copper MIL-W-25038/3/2/ 600 260 See specification sheet * See specification sheet MIL-W-81044/6 600 150 Crosslinked polyalkene Tin coated copper MIL-W-81044/7 600 150 Crosslinked polyalkene Silver coated high strength copper alloy MIL-W-81044/9 600 150 Crosslinked polyalkene Tin coated copper MIL-W-81044/10 600 150 Crosslinked polyalkene Silver coated high strength copper alloy * Inorganic Fibers - Glass - TFE Page 11-40 Par 11-89
TABLE 11-12. Protected wiring.
Document Voltage rating (maximum) Rated wire temperature (°C) Insulation Type Conductor type MIL-W-22759/11 600 200 Fluoropolymer insulated extruded TFE Silver coated copper MIL-W-22759/12 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper MIL-W-22759/14 600 135 Fluoropolymer insulated FEP-PVF2 Tin coated copper MIL-W-22759/15 600 135 Fluoropolymer insulated FEP-PVF2 Silver plated high strength copper alloy MIL-W-22759/18 600 150 Fluoropolymer insulated extruded ETFE Tin coated copper MIL-W-22759/19 600 150 Fluoropolymer insulated extruded ETFE Silver coated high strength copper alloy MIL-W-22759/22 600 200 Fluoropolymer insulated extruded TFE Silver coated high strength copper alloy MIL-W-22759/23 600 260 Fluoropolymer insulated extruded TFE Nickel coated high strength copper alloy MIL-W-22759/32 600 150 Fluoropolymer insulated crosslinked modified ETFE Tin coated copper MIL-W-22759/33 600 200 Fluoropolymer insulated crosslinked modified ETFE Silver coated high strength copper alloy MIL-W-22759/44 600 200 Fluoropolymer insulated crosslinked modified ETFE Silver coated copper MIL-W-22759/45 600 200 Fluoropolymer insulated crosslinked modified ETFE Nickel coated copper MIL-W-22759/46 600 200 Fluoropolymer insulated crosslinked modified ETFE Nickel coated high strength copper alloy MIL-W-81044/12 600 150 Crosslinked polyalkene - PVF2 Tin coated copper MIL-W-81044/13 600 150 Crosslinked polyalkene - PVF2 Silver coated high strength copper alloy MIL-W-81381/17 600 200 Fluorocarbon polyimide Silver coated copper MIL-W-81381/18 600 200 Fluorocarbon polyimide Nickel coated copper MIL-W-81381/19 600 200 Fluorocarbon polyimide Silver coated high strength copper alloy MIL-W-81381/20 600 200 Fluorocarbon polyimide Nickel coated high strength copper alloy MIL-W-81381/21 600 150 Fluorocarbon polyimide Tin coated copper