N342NB
Service difficulty reports · 220
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N342NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N342NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13056603142Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 161NF HAS MULTIPLE DENTS & PUNCTURED. FLOOR PANEL FABRICATED IAW AMM 25-50-00-340-007-A AND DWG 3D25-4032.SDR DALA13056203142Floor Support · corrodedDURING CLEANING, FOUND FWD CABIN FLOOR SUPPORT Y503.2 AT FRAME 16 CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 53-11-14, FIG 106. R & R FLOOR SUPPORT IAW TRM 53-21-01.SDR DALA13056193142Floor Support · corrodedFORWARD UTILITY AREA FLOOR SUPPORT Y-765 BETWEEN FRAMES 16-20 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-15, FIG 101. REMOVED & INSTALLED FLOOR SUPPORT IAW TRM 53-21-01. CUT OUT DAMAGED AREA IAW 53-11SDR DALA13056183142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y765 BETWEEN FRAMES 64-66 UPPER FLANGE & HARDPOINT HOLES CORRODED. BLENDED AREA IAW SRM 51-74-00. FOUND OUT OF LIMIT IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & DWG D53472815.SDR DALA13056173142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y1292 BETWEEN FRAMES 64-66 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13056163142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y1292 BETWEEN FRAMES 68-69 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13056153142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y1292 BETWEEN FRAMES 66 - 68 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13056143142Floor Support · corrodedFORWARD UTILITY AREA FLOOR SUPPORT Y-254, BETWEEN FRAMES 16 - 20 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 105. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13056133142Hinge Pin · corrodedRIGHT WING AILERON HINGE PIN CORRODED. NEW HINGE PIN INSTALLED ON JIC 5760-1010S-RT.SDR DALA13056093142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y765 BETWEEN FRAMES 66-69 UPPER FLANGE CORRODED.BLENDED AREA IAW SRM 51-74-00 AND FOUND OUT OF LIMIT IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & DWG D53472815.SDR DALA13056083142Floor Panel · corrodedAFT UTILITY AREA FLOOR PANEL 261FF CORRODED. INSTALLED NEW FLOOR PANEL.SDR DALA13056113142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241MF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056103142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 261HG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102.SDR DALA13056073142Floor Panel · corrodedMAIN CABIN FLOOR PANEL 231CF HAS CORRODED INSERTS. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056063142Sill · corrodedLT AFT PASSENGER/CREW DOOR SILL BEAM AT AFT INBD FRAME 66 NUTPLATE HOLES CORRODED. REPAIRED IAW SRM 53-41-14, FIG 201.SDR DALA13056053142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221DF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056043142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222EF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056033142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221EF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW 3SRM 53-02-00, FIG 209.SDR DALA13056023142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231XG UPPER SURFACE DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056013142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232YG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056003142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232FF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055993142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231LF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055983142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232YG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055973142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241KF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055963142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241CF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055953142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241JF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG.102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055943142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241HF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055933142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241AF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055923142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 242KF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055913142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 252GF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055903142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251JF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055893142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 252MF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055883142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251LF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG.102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055863142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251TF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055853142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 261HG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055383142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y-1292, BETWEEN FRAMES 68 - 69 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13055373142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y-1292, BETWEEN FRAMES 65-66 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13055363142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y-1292 BETWEEN FRAMES 66 - 68 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13055353142Structure · corrodedLEFT WING MANUAL REFUEL OPENING INTERFACE CORRODED. REMOVED CORROSION IAW SRM 57-21-11, PAR 5E. FOUND TO BE IN LIMITS IAW SRM 57-21-11, FIG 205. PERFORMED FPI IAW NTM 51-80-00, NO DEFECTS NOTED. APPLIED CHEMICAL CONVERSION COATING IAW SRM 57-21-11, PAR 5-SDR DALA13055053142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251WF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055043142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241BF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055033142Floor Panel · damagedAFT UTILITY FLOOR PANEL 261PF DELAMINATED AND HAS SEVERAL PUNCTURES. FOUND OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055023142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 261HG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055013142Shear Plate · corrodedAFT UTILITY AREA STRINGER 23R BETWEEN FRAMES 69-70, SHEAR PLATE UPPER SURFACE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. NO ESTABLISH LIMITS FOUND IN SRM 53-41-14, TABLE 101. R & R SHEAR PLATE IAW SRM 51-42-11 & DWG D53474180.SDR DALA13055003142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT Y-765 BETWEEN FRAMES 64-66 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13054993142Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT, Y-765, BETWEEN FRAMES 66-69 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13054983142Floor Support · corrodedFORWARD UTILITY AREA FLOOR SUPPORT Y254 BETWEEN FRAMES 16-21 UPPER FLANGE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 105. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13054973142Sill · corrodedRIGHT AFT PASSENGER/CREW DOOR SILL BEAM AT INBD FRAME 68 UPPER SURFACE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14. R & R SILL IAW SRM 51-42-11 & DWG D53480020.SDR DALA13054793142Floor Support · corrodedFORWARD UTILITY AREA FLOOR SUPPORT, Y-1292 BETWEEN FRAMES 16-20 UPPER FLANGE HAS CORROSION. BLENDED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-15, FIG 101. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. LOCATED & DRILLED NEW FLOOR SUPPORT SDR DALA13054783142Web · corrodedFORWARD UTILITY AREA STRINGER 23R BETWEEN FRAMES 20-21, UPPER SURFACE WEB & ANGLE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. NO ESTABLISH LIMITS IAW SRM 53-11-14. R & R WEB & ANGLE IAW SRM 51-42-11 AND DWG D53004332.