N447WN
Service difficulty reports · 396
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N447WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N447WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021091500100Sidewall Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 490 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BS 490SDR SWAA2021091500099Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500 +14 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSSDR SWAA2021091500080Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 480 +14 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSSDR SWAA2021091500073Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500A +6 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSSDR SWAA2021091500072Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500C +10 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500109Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 498 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 498 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500108Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 494.5 RBL 23 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 494.5 RBL23 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] SDR SWAA2021091500096Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500A +14 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500088Shield · corrodedCORROSION ON FWD SHIELD FWD CARGO BAY BS 431 RBL 23 WL 156 ; / [01] CORROSION FOUND ON FWD SHIELD FWD CARGO BAY BS 431 RBL23 WL156; P/N 143A8126-21; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500087Shield · corrodedCORROSION ON FWD SHIELD FWD CARGO BAY BS 425 RBL 24 WL 156 ; / [01] CORROSION FOUND ON FWD SHIELD FWD CARGO BAY BS 425 RBL24 WL156; P/N 143A8126-21; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500086Shield · corrodedCORROSION ON FWD SHIELD FWD CARGO BAY BS 422 RBL 23 WL 156 ; / [01] CORROSION FOUND ON FWD SHIELD FWD CARGO BAY BS 422 RBL23 WL156; P/N 143A8126-21; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500085Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 514 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 514 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500084Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 502 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 502 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500090Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT AFT CARGO BAY BS812 - BS831 RBL26 WL160. ; / [01] REMOVED CORROSION ON SUBTHRESHOLD WEB AT ACB BS812 - BS831 RBL26 WL160. REWORKED AREA L:6.3' W: 1' D: 0.010'; ORIGINAL THICKNESS: 0.045'; MAT REMOVED: 0.010'; REMAINING MAT: 0.0SDR SWAA2021091500094Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500A +14 RBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSDR SWAA2021091500077Support · corrodedCORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 500 +10 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BSSDR SWAA2021091500114Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 518 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 518 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500112Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 510 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 510 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500110Shield · corrodedCORROSION ON AFT SHIELD FWD CARGO BAY BS 506 RBL 24 WL 156 ; / [01] CORROSION FOUND ON AFT SHIELD FWD CARGO BAY BS 506 RBL24 WL156; P/N 143A8126-19; FOUND TO BE OUT OF LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9.C.; [02] VERISDR SWAA2021091500061Shield · corrodedCORROSION ON FWD SHIELD AT AFT CARGO BAY BS779 RBL21 WL156. ; / [01] EVALUATED ON FWD SHIELD AT AFT CARGO BAY BS779 RBL21 WL156;AND NOT FOUND ALLOWABLE DAMAGE LIMITS ON SRM; MUST BE REPLACED IAW SRM 51-10-02 PARA#9.; [02] VERIFIED NO SRM LIMITS; [03] REMOVED OSDR SWAA2021091500069Floor Panel · delaminatedFLOOR PANEL 242VF HAS SEVERAL AREAS OF DELAMINATION ON UPPER AND LOWER SKINS ; / [08] VERIFIED SANDED POTTING COMPOUND AND CORE PLUG FLUSH AND CLEANED. FABRICATED REPAIR PLIES FROM BMS 9-3 TYH2 LOT# 1458851-1 IAW SRM 53-00-50-2R-6 PARA 3.G AND 3.J. AND SRM 53-SDR SWAA2021091500035Support Angle · crackedCRACKED SUPPORT ANGLE AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS914 RBL12 WL171. ; / [01] DAMAGE FOUND ON SUPPORT ANGLE AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS914 RBL12 WL171; P/N 147A7221-32; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ON SRM PART WSDR SWAA2021091500041Support Angle · crackedCRACKED SUPPORT ANGLE AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS918 RBL12 WL171. ; / [01] DAMAGE FOUND ON SUPPORT ANGLE AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS918 RBL12 WL171; P/N 147A7221-32; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ON SRM PART WSDR SWAA2021091500044Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727D+10 RBL21 WL156. ; / REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS727D+10' RBL21 WL156 ;DIMENSION. L=2'X W=1.2' DEPTH:.010 IAW SRM 51-10-02.PARA#15;EVALUATED FLOOR TO SIDEWALL SUPPOSDR SWAA2021091500055Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS924 RBL22 WL175. ; / [01] VERIFIED APPLICABILITY OF SRM 53-70-53-0I-2FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.; [02] REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT BS924 RBL22SDR SWAA2021091500028Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS869 RBL19 WL165. ; / [01] VERIFIED APPLICABILITY OF SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM TO SIDEWALL SUPPORT AT AFT CARGO BAY BS86SDR SWAA2021091500036Cargo Track · corrodedCORROSION ON RAIL AT AFT CARGO BAY BS889 RBL2 WL168. ; / [01] REMOVED CORROSION ON RAIL AT AFT CARGO BAY BS889 RBL2 WL168; DIMENSION L=1' W=0.8' D=0.012'; WAS FOUND OUT OF LIMIT IAW SRM 53-00-53-1A-2; [02] REMOVED RAIL AT AFT CARGO BAY BTW. BS.887-BS947;RBL3;WSDR SWAA2021091500064Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS758 RBL21 WL156. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 758 RBL21 WL156 ;DIMENSIONS L=2.5' W=2.' DEPTH .009' IAW SRM 51-10-02 PARA#15;EVALUATED TO SIDEWALL SUPPORT;ORIGISDR SWAA2021091500063Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS754 RBL21 WL156. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 754RBL21 WL156;DIMENSIONS L=1.3' W=1.' DEPTH .011 IAW SRM 51-10-02 PARA#15 .EVALUATED TO SIDEWALL SUPPORT ;ORIGINSDR SWAA2021091500054Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS929 RBL22 WL175. ; / [01] VERIFIED APPLICABILITY OF SRM 53-70-53-0I-2FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.; [02] REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT BS929 RBL22SDR SWAA2021091500045Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727E+10 RBL21 WL156. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS727E+10 RBL21.DIMENSIONS L=2.' W=1.3'.IAW SRM 51-10-02 PARA#15 EVALUATED TO SIDEWALL SUPPORT;ORIGINAL THICKNESSDR SWAA2021091500043Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727E+3 RBL21 WL156 ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 727E+3 RBL21 WL;156;DIMENSIONS L=1.8' W=1.5'DEPTH .008 IAW SRM 51-10-02 PARA#15 ;EVALUATED TO SIDEWALL SUPPORT;SDR SWAA2021091500033Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727E+18 RBL21 WL156. ; / [01] REMOVED CORROSION ON TO SIDEWALL SUPPORT AT AFT CARGO BS 727E+18 RBL21 WL 156 .DIMENSIONS L=1.2' W=1.' DEPTH .009 IAW SRM 51-10-02 PARA#15;EVALUATED TO SIDEWALL SUPPORT ORISDR SWAA2021091500032Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS758 RBL21 WL156 ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 758 RBL21 WL156;DIMENSIONS L=2.' W=1.4' DEPTH .009' IAW SRM 51-10-02 PARA#15;EVALUATED TO SIDEWALL SUPPORT ;ORIGINSDR SWAA2021091500056Shield · corrodedCORROSION ON AFT SHIELD AT AFT CARGO BAY BS852 RBL23 WL164. ; / [01] DAMAGE FOUND ON AFT SHIELD AT AFT CARGO BAY BS 852 RBL23 WL164; P/N: 146A8127-10; FOUND TO BE OUT OF LIMITS ON SRM PARTS WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR.9.C.; [02] VSDR SWAA2021091500070Panel · chafedPANEL 192F HAS CHAFING DAMAGE ON FWD AND AFT EDGE MATING SURFACES ; / [01] IDENTIFIED PANEL 192F MATERIAL IAW SRM 53-40-70-0I-1 FIG 2 TABLE 2 ITEM [15]. <BR>REMOVED FINISH IAW AMM 51-21-11-150-815 PARA. 17. C. AND D.<BR>FOUND CHAFING DAMAGE ON INNER FWD AND AFSDR SWAA2021091500059Shield · corrodedCORROSION ON FWD SHIELD AT AFT CARGO BAY BS771 RBL21 WL156. ; / [01] EVALUATED FWD SHIELD AT AFT CARGO BAY BS771 RBL21 WL156 AND NOT FOUND ALLOWABLE DAMAGE LIMITS ON SRM ; MUST BE REPLACED IAW SRM 51-10-02 PARAGRAPH 9; [02] VERIFIED NO SRM LIMITS; [03] THIS DISDR SWAA2021091500060Shield · corrodedCORROSION ON FWD SHIELD AT AFT CARGO BAY BS775 RBL21 WL156. ; / [01] EVALUATED DAMAGE ON FWD SHIELD AT AFT CARGO BAY BS775 RBL21 WL156;AND NOT FOUND ALLOWABLE DAMAGE LIMITS ON SRM;MUST BE REPLACED IAW SRM 51-10-02 PARA#9.; [02] VERIFIED NO SRM LIMITS; [03] THISDR SWAA2021091599385Intercostal · crackedCRACKED INTERCOSTAL AT B.S. 312-328; RBL 30.5; WL 208.1. ; / [01] REMOVED INTERCOSTAL LOCATED BTW BS312-328 RBL 30.5 WL 208.1 IAW SRM 53-00-04-1A-1 ALLOWABLE DAMAGE 1 THE LOCATION OF THE DAMAGED IS NOT CONTEMPLATED IN THE SRM. INTERCOSTAL MUST BE REPAIRED BY RSDR SWAA2021091599387Intercostal · crackedCRACKED INTERCOSTAL AT B.S. 277-294.5; RBL 1; WL 208.1. ; / [01] REMOVED INTERCOSTAL LOCATED BTW BS.277-294.5 RBL 1 WL 208.1 IAW SRM 53-00-04-1A-1 ALLOWABLE DAMAGE 1 THE LOCATION OF THE DAMAGED IS NOT CONTEMPLATED IN THE SRM. INTERCOSTAL MUST BE REPAIRED BY RESDR SWAA2021091599388Intercostal · crackedCRACKED INTERCOSTAL AT B.S. 328-344; LBL 45; WL 208.1. ; / [01] REMOVED INTERCOSTAL LOCATED BTW BS328-344 LBL 45 WL 208.1 IAW SRM 53-00-04-1A-1 ALLOWABLE DAMAGE 1 THE LOCATION OF THE DAMAGED IS NOT CONTEMPLATED IN THE SRM. INTERCOSTAL MUST BE REPAIRED BY REPLASDR SWAA2021091599414Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT WET AREA BS986.5 RBL43 WL208. ; / [01] REMOVED CORROSION ON FLOOR BEAM AFT WET AREA BS 986.5 RBL 43 WL208 IAW SRM 51-10-02-0G-0 AND EVALUATED AREA AND FOUND TO BE OUT OF LIMITS IAW 53-70-51-1A-1 PART 4H MEASURES L=1.1'' X W=0.878SDR SWAA2021091599411Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT WET AREA BS986.5 RBL36 WL208. ; / [01] REMOVED CORROSION ON FLOOR BEAM AFT WET AREA BS 986.5 RBL 36 WL208 IAW SRM 51-10-02-0G-0 AND EVALUATED AREA AND FOUND TO BE OUT OF LIMITS IAW 53-70-51-1A-1 PART 4H MEASURES L=1'' X W=0.8 X DSDR SWAA2021091599392Floor Panel · delaminatedFLOOR PANEL 242UF HAS DELAMINATIONS TO UPPER AND LOWER SKINS. ; / [10] REMOVED (2EA) DRAIN FITTING ASSEMBLIES DUE TO BEING LOOSE AND FALLING OFF PANEL IAW SRM 53-00-50-2R-1 PARA 3.B AND DRAWING 140A1005. WILL REQUIRE REINSTALL UPON REPAIR COMPLETION.; [11] CURSDR SWAA2021091599384Intercostal · crackedCRACKED INTERCOSTAL AT B.S. 321-328; LBL 45; WL 208.1. ; / [01] REMOVED INTERCOSTAL LOCATED BTW BS.312-328 LBL 45 WL 208.1 IAW SRM 53-00-04-1A-1 ALLOWABLE DAMAGE 1 THE LOCATION OF THE DAMAGED IS NOT CONTEMPLATED IN THE SRM. INTERCOSTAL MUST BE REPAIRED BY REPLSDR SWAA2021091598745Floor Panel · cracked242XF CABIN FLOOR PANEL CRACKED THROUGH BOTH UPPER AND LOWER PLIES. ; / [11] REPAIRED CRACK ON FLOOR PANEL 242XF IAW SRM 53-00-50-2R-4; [12] VERIFIED COMPLETION OF REPAIR ON CORRECTIVE ACTION 11 PER SRM 53-00-50-2R-4; [13] VERIFIED COMPLETION OF REPAIR ON CORRSDR SWAA2021091599399Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT WET AREA BS986.5 RBL40 WL208. ; / ACCOMPLISHED PERMANENT REPAIR ON FLOOR BEAM AFT WET AREA BS986.5 RBL20-RBL51 WL208 IAW SRM 53-70-51-2R-4 REPAIR#4SDR SWAA2021091599394Channel · corrodedCORROSION ON MOP SILL AT AFT WET AREA BS 952 TO BS 987 LBL 49 WL 208 ; / [01] REMOVED AND EVALUATED CORROSION AT DISCREPANCY AREA. L=1' W=1.5. ORIGINAL THICKNESS 0.080' REMAINING 0.067' LOSS= 0.013' BLEND LOCATION FOUND TO BE OUT OF LIMITS PER SRM 53-70-15-1A-SDR SWAA2021091599417Tee Fitting · corrodedCORROSION ON WATER LINE T-FITTING AT AFT WET AREA BS930 RBL43 WL204. ; / [01] EVALUATED CORROSION AT T-FITTING AREA L=0.400' W=0.400' AT WET AREA BS930 RBL43 WL204 NO ALLOWABLE DAMAGE AT SRM . PART TO BE REPAIR BY REPLACEMENT PER SRM 51-10 02.; [02] VERIFIED; SDR SWAA2021091599401Web · corrodedCORROSION ON 1016 WEB AT AFT WET AREA BS 1029 BL 0 WL 208 ; / [01] REMOVED AND EVALUATED CORROSION REMOVAL AT DISCREPANCY AREA L= 0.4' W=0.2'. NO ALLOWABLE DAMAGE FOUND ON SRM. PART TO BE REPAIR BY REPLACEMENT PER SRM 51-10-02; [03] REMOVED DAMAGE AREA L= 0.4'
Back to N447WN