N651UA
Service difficulty reports · 345
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N651UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N651UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013011400220Stringer · damagedSTRINGER 37R BS 500 DAMAGED. REPAIRED IAW ECRA 5331-01676.SDR UALA2013011400210Skin · damagedSCRATCH AND DENT FOUND BETWEEN BS 478- 522 S36-38R BELOW FWD CARGO DOOR. DENT DAMAGE EXCEEDS SRM 53-00-01 FIG 101 LIMITS. ECRA 5330-04380 FOLLOWED FOR INTERIM REPAIR. GOUGE BLENDED PER SRM 53-00-01 FIG 101 DETAIL II. HFEC INSPECTION PER NTM PART 6-51-00-SDR UALA2013011400206Frame · corrodedBS 977 FRAME CORRODED ON OUTER ANGLE AT S22R. CORROSION REMOVED PER SRM 53-00-01. BLEND OUT EXCEEDED MAX LIMITS, AND REPAIRED IAW ECRA 5352-01075. MAJOR REPAIRSDR UALA2013010900126Actuator · no testLEFT OVERWING ESCAPE SLIDE FAILED DEPLOYMENT CHECK, SPOILER ACTUATOR FIRED BUT DOOR DID NOT OPEN AND SLIDE DID NOT DEPLOY. REMOVED AND REPLACED FWD DOOR OPENING ACTUATOR CABLE. FOUR DOOR LATCHES REPLACED. SLIDE DEPLOYMENT BOTTLE REPLACED. REPLACED NR 6 SPSDR CALA2013121393678Chiller · faultyCHILLER C31 POPS CB WITH MEL 2520NB. PULLED & COLLARED CB. CHILLER IS MID GALLEY FWD SECTION. REPLACED MID GALLEY CHILLER POS C31 IAW AMM, OPERATIONS CHECKED NORMAL.SDR UALA2012120407012Wire · unsecureTHE 24A WIRE HANGING OUT. CAPPED & STOWED EMERGENCY SEAT EXIT LIGHT FOR SEAT 23AB, STOWED WIRES UNDER SEAT IN THE OUTBOARD LEG SEAT BOX PANEL. REPINNED CAPPED WIRES AND INSTALLED CONNECTOR REF SWPM 20-64-17, SEAT 23AB EMERGENCY PATH LIGHT CHECK'S GOOD.SDR UALA2012120306932Structure · dentedSCRATCH AND DENT FOUND BETWEEN STA 478- 522 S38-36R BELOW FWD CARGO DOOR SCRATCH 34.5" WAVE. WAVE FORM 6".DENT IS 10" LONG 3.5" WIDE DEPTH .147. FOUND ON ARRIVAL TO LHR. DENT DAMAGE EXCEEDS SRM 53-00-01 FIG 101 LIMITS. EC-RA 5330-04380 FOLLOWED FOR INTERIMSDR UALA2012102606158Hydraulic System · lowRIGHT HYD LOW NEEDS FLUID READS .66. SERVICING PERFORMED AS AMM TASK 12-12-01-703-062 OK. ADDED 5 QTS HYD OIL TO CTR AND 7 QUARTS IN THE RIGHT RESERVOIR.SDR UALA2012102506133Hose · leakingLEFT GEAR BREAK LINE LEAKING. WORKING WITH LOCAL MECH TO ID WHICH LINES AND BRAKE, WORKING WITH ORDLE FOR AN ECRA TO DEF THE BRAKE. LOOKING FOR CAPS TO CAP LINES. FOUND NR 1 BRAKE FLEX HYD LINE ABOVE THE GEAR LEAKING HYD, REF IPC 32-41-62-005, ITEM 172(160-SDR UALA2012091905303Clamp · unsecureUNUSUAL HEAT BLOWING FROM FLOOR LEVEL SIDEWALL VENTS AT LEFT SIDE ROW 38. INSPECTED REAR AND BULK CARGO HEAT VALVES. FOUND ON BULK CARGO HEAT VALVE UPPER PIPING CLAMP CONNECTION SLIGHT HOT AIR ESCAPING. CHECK TIGHTENED CLAMP CONNECTION AND SUBSEQUENT LEAK CSDR UALA2012091305173Unknown · malfunctionedMID CABIN AUTO CONTROL INOPERATIVE.SDR UALA2012080604226Knob · looseFIRST OFFICER'S RADAR AND HSI DIMMING KNOB LOOSE AND CAN BE LIFTED VERTICALLY OUT OF DETENT. REPLACED THE UNIT.SDR UALA2012072504036Stator · brokenON WALKAROUND, FOUND PARTS OF NR 7 BRAKE UNIT STATOR BROKEN. NR 7 MAIN WHEEL BRAKE ASSY REPLACED AS PER AMM. INSPECTED MAIN AXLE ASSY NO DAMAGE OR FAULTS FOUND MAIN WHEEL ASSY REMOVED AND REFITTED AS PER AMM. WHEEL INSPECTED, NO DAMAGE FOUND.SDR UALA2012070303570Actuator · crackedHYD QTY DECREASED TO ZERO AND SYSTEM PRESS AND QTY LIGHT ILLUM EICAS MSG DISPLAYED (L,R) HYD SYS PRESSURE, (L,R) HYD QTY POS 1 (01=L,02=R). FRM CODE 29 11 12 --. ON INSPECTION FOUND LEFT WING INBOARD SPOILER ACTUATOR NR 6 HAS CRACKED CASE. REPLACED ACTUATOR SDR UALA2012061403274Latch · unsecureTHIRD FASTENER ABOVE RIGHT ENG OUTBOARD SIDE UNLATCHED. SECURED LATCH.SDR UALA2012060803139Power Cable · damagedAFT GALLEY, PIGTAIL P51 P52 P53 HAS EXPOSED WIRES. REPLACED P52 AND P53 PIGTAIL POWER CORDS. REPLACED P51 PIGTAIL. ALL PIGTAILS OPERATE NORMAL.SDR UALA2012041502280Switch · no testLEFT ENG BLEED LIGHT INOP AND WILL NOT TEST. RELAMPED LIGHT SW.SDR UALA2012041202207Audio Panel · malfunctionedSEAT AUDIO STATIC ROWS 19AB THROUGH 39AB.SDR UALA2012040902192Duct · blownROW 19 AB BLOWN DUCT, SECURED WITH TYPE 44 ADHESIVE REF BAC DWG 214T4020.SDR UALA2012031201622Valve · faultyHAD TO X FEED TWICE DUE TO 1500LBS IMBALANCE. FMC SHOWED EVEN BURN ON BOTH ENGINES. DUE TO HISTORY OF UNWANTED FUEL TRANSFER, REPLACE THE FWD AND AFT FUEL CROSSFEED VALVES & ACTUATORS. REPLACED BOTH XFEED VLVS AND ACTUATORS, AND ALL TESTED NORMAL.SDR UALA2012031401664Structure · damagedRAMP REPORTS SMALL HOLE IN AFT PIT FLOOR. RPR MADE PER GNMM 1- 0-1-102. HOLE LOCATED NEAR CARGO NET ATTACH IN MIDDLE OF BULK PIT. REPAIRED SMALL HOLE PER SRM 53-60-53.SDR UALA2012030201317Display · faultyUPPER EICAS SCREEN SHOWING INCORRECT COLORS AND STATUS WON'T DIM AFTER SHUTDOWN. REPLACED UPPER EICAS DISPLAY PER AMM. OP CHECK OKAY.SDR UALA2012021700963Engine · vibrationDUE TO REPEAT VIB IND HIGHER THAN NORMAL TO PREVENT IRREG OPS, ACCOMPLISH FAN BLADE ROOT LUBE. `WILL REQUIRE VIBRATION SURVEY (HIGH POWER RUN), TEST NR 8 PER AMM. ACP'D TEST NR 8 VIBRATION SURVEY. TEST FAILED, (N1 VIB) INDICATES 4.2 AT 78% N1 AND (BB VIB) WSDR UALA2012012600554Fitting · wornLT MLG TRUNNION DOOR AFT HINGE HAS EXCESSIVE PLAY. FOUND AFT DOOR FITTING HAT BUSHINGS WORN AND PULLED OUT OF FITTING. NEW FITTING ASSY ON ORDER. WILL NEED FITTING 113T8313-6 AOG S5293. WORKING OUTSIDE. WILL REQUIRE GEAR SWING AFTER FITTING REPLACEMENT. SDR UALA2012011300285Seat · unsecureROW 37 MIDDLE SECTION OF SEATS COMING UNATTACHED FROM FLOOR ON RIGHT SIDE. SECURED SEAT ASSEMBLY IN TRACK.SDR UALA2011121406839Hose · crackedONE HOSE TO THE ANTI SKID SHUT OFF VALVE MODULE IS CRACKED. BRAKE POS 6 HAS BEEN DEACTIVATED. REPAIRED, PRESSURIZED LINE TO 6K PSI, NO LEAKS NOTED. FOUND BAD UNION PACKING. REPLACED PACKING, OPS NORMAL.SDR UALA2011102405762Module · malfunctionedALTITUDE ALERT CHIME GOES OFF RANDOMLY THROUGHOUT FLIGHT IN CRUISE. REPLACED LEFT SIREN-OWL MODULE M999, REF MM.SDR UALA2011081904427Filter · dirtyAPU FAILED. APU FAILED AT DEP TIME. TROUBLE SHOT PER FAULT DISPLAY. ACCOMPLISHED BITE CHECK. FAULT DISPLAY SHOWED "GEN FILTER" FAULT. REPLACED GENERATOR SCAVENGE FILTER AND LUBE FILTER ASSY'S IAW MM. APU STARTS AND RUNS NORMAL.SDR UALA2011081804398Modulating Valve · faultyAFT CABIN TEMP EICAS. PERFORMED BITE ZONE TEMP CONTROLLER, FOUND AFT TRIM AIR VALVE FAULT, DEFERRED AFT TRIM AIR VALVE PER MEL 2161BB, VALVE SHOWED CLOSED ON EICAS, SECURED CLOSE PER CB'S PULL OUT IAW MEL PROCEDURE 1. REPLACED AFT TRIM AIR VALVE, NO HELP. SSDR UALA2011080103977B-Nut · leakingFLAP SLAT HYDRAULIC SHUTOFF VALVE IN RT MAIN GEAR WHEEL WELL LEAKING 20 DROPS PER MINUTE FROM PRESSURE PORT B-NUT. ACCOMPLISHED RINGLOCK REPAIR TO PRESSURE PORT END OF TUBE PER GNMM. LEAK CHECK OKAY.SDR UALA2011071303537Skin · dentedDURING ACFT LOADING HAD IMPACT AT DOOR 2L. STATION IS 46 BETWEEN 1540 TO 1562 AND STRINGER LOC IS APPROX S22 TO S23. DIMENSIONS OF THE DENT ARE (INCHES): LENGTH 3.5 WIDTH 2.75 AND DEPTH 0.0858. THE DENT IS SMOOTH WITH NO SHARP EDGES CUTS OR CREASE, ADJACENTSDR UALA2011070703363Connector · unsecureEEL EXIT SIGNS AND OVERHEAD AISLE LIGHTS INOP AFT RT SECTION. SECURED CONNECTOR ON PWR SUPPLY ASSY M734, CHECKS OKAY.SDR UALA2011070703362Light · inoperativeAFT SEAT MOUNTED EEL INOP AT SEAT 8AB. RELAMPED, OP NORMAL.SDR UALA2011061502946Pump · malfunctionedCENTER R FUEL PUMP DISPLAYED, CB GRIB ON P6-4 F21 R FUEL OVERRIDE PUMP. REPLACED CENTER RT FUEL OVERRIDE PUMP PER MM, OPS CHECKS GOOD.SDR UALA2011061502950Cdu · faultyR CDU (F-O) BLANKED OUT, RTFL. REPLACED R CDU PER MM, OPS CHECKS OKAY.SDR UALA2011061002857Start Valve · failedRIGHT ENGINE START VALVE LIGHT DID NOT EXTINGUISH WHEN START VALVE CLOSED. CYCLED CIRCUIT BREAKER D20. DURING NEXT START ATTEMPT, VALVE LIGHT CAME ON BUT NO DUCT PRESSURE DROP. OBSERVED & N2 ROTATION. REPLACED NR 2 ENG STARTER AND START VALVE. OPERATIONSDR UALA2011060702783Seal · leakingDOOR PRESSURE LEAK, RTFL CAN SEE DAYLIGHT UNDER DOOR. FOUND LOOSE AND THRESHOLD FOUND INTACT AND IN GOOD CONDITION. LEAKED CHECKED DOOR PER MM, NO LEAKS FOUND.SDR UALA2011060602775Handset · inoperativePURSER UNABLE TO CALL COCKPIT FROM DOOR 1L. REPLACED HANDSET AT 1L, OPS CHECK. GOOD.SDR UALA2011050902294Bottle · unserviceableLEFT OFF WING EMERGENCY SLIDE BOTTLE NEEDS REPLACEMENT. REPLACED LT OVERWING SLIDE EMERGENCY BOTTLE. ACCOMPLISHED RII INSPECTION AS REQUIRED REF MM. ALL PINS REMOVED AND SYSTEM RE-ARMED.SDR UALA2011031501247Battery Pack · inoperativeEMERGENCY EXIT LIGHTS ON AFT OF CABIN. REPLACED AFT RT SIDE BATTERY PACKS PER MM.SDR UALA2011030201034Slide · unsecureDOOR 1R SLIDE HAS COVER LACING UNRAVELED ON THE AFT SIDE. REMOVED AND REPLACED DOOR 1 RIGHT SLIDE RAFT ASSY PER MM.SDR UALA2011022100866Feeder Cable · burnedAPU GEN WILL NOT STAY ON LINE. APU RUNS AIR. APU ELECTRICAL INOP. APU PNEUMATIC FUNCTION IS OK. DEFERRED APU GENERATOR PER MEL. HMG TEST OK. GROUND CREW REPORTS THE 2ND AND 3RD FEEDER WIRES ARE BURNED AT THE GENERATOR TERMINAL BLOCK . THE FEEDER WIRES ARE SECSDR UALA2011021400778Light · inoperativeEMERGENCY FLOOR PATH LIGHT RT AISLE FWD GALLEY (L901) AND EMERGENCY EXIT IDENTIFIER AT DOOR 1 RT (L972) ARE INOP. REPLACED LIGHT ASSY, TESTED OK.SDR UALA2011020400616Stand Off · brokenFOUND P33 PANEL EQUIPMENT SHELF STANDOFFS BROKEN. OPENED P33 PANEL REMOVED INSIDE RELAY BRACKET, REMOVED 2 UPPER BROKEN STAND OFFS STARTED TO FABRICATE LOWER CORNER STRAP REPAIR. NO ELECTRICAL COMPONENTS WERE DISTURBED INSIDE P-33 PANEL. ALSO REPLACED BROKEN SDR UALA2010121504585Wire Harness · damagedWINDSHIELD HEAT MESSAGE, RTFL. WINDOW L1 FOUND J5 WIRE HARNESS TERMINAL PROTECTOR CAP MELTED. DISCONNECTED TERMINAL BLOCK FROM WINDOW. REPLACED TERMINAL AND WIRE ASSY. OPS NORMAL.SDR UALA2010120804487Control Unit · faultyRIGHT AND LEFT UTILITY BUSSES WILL NOT COME ON LINE AND A-C WILL NOT TAKE GROUND POWER. REPLACED BUSS POWER CONTROL UNIT IAW MM. OPS CKS NORMAL. BOTH UTILITY BUSSES ON LINE AND A-C WILL ACCEPT GROUND POWER.SDR UALA2010110104049Diplexer · malfunctionedSATCOM FAILED TWICE DURING CALLS. INITIALLY COMMS ESTABLISHED BRIEFLY AND THEN DROPPED. REPLACED M1791, DUE TO A LGA HPA VSWR FAULT. OPS CK OK.SDR UALA2010102804000Engine · cokedNR1 ENGINE HAS COAKING ON VSV AND COMPRESSOR CASE. REPLACED ENGINE.SDR UALA2010102503955Idg · faultyLOAD SHED ISSUES. DUE TO REPORT OF RT HYD QTY INDICATION DROP TWO TIMES AND FWD AND RT AFT GALLEY POWER WENT OFF NEED TO PERFORM A VISUAL INSPECTION OF RT GEN BREAKER TERMINALS (3 PHASE) C903. REPLACED RELAY & REPLACED NR 2 ENG IDG PER MM.SDR UALA2010102103895Actuator · leakingAFTER ARRIVAL FOUND LT ENGINE FUEL LEAK FROM DRAIN TUBE NR5, VARIABLE STATOR VANE ACTUATOR. PERFORMED ENG RUN UP IAW AMM. LEAK WITHIN LIMIT IAW AMM. REPLACE THE VSV ACTUATOR NOT MORE THEN 50 F HOURS. INSPECT THE LEAK BEFORE EACH DEPARTURE. TO PREVENT IRREG
Back to N651UA